Results from R&D of Cherenkov detectors at Novosibirsk

Similar documents
Development of aerogel Cherenkov counters at Novosibirsk

Tests of the Burle anode MCP PMT as a detector of Cherenkov photons

Four-layer aerogel Cherenkov counter

Lecture 16 Light transmission and optical detectors

The HERMES Dual-Radiator Ring Imaging Cerenkov Detector N.Akopov et al., Nucl. Instrum. Meth. A479 (2002) 511

Author s Accepted Manuscript

Aerogel counter with a Fresnel lens. Guy Paic Instituto de Ciencias Nucleares UNAM Mexico

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

THE LHCb experiment [1] is equipped with two Ring

RICH detectors for LHCb

Refractive index inhomogeneity within an aerogel block

Physics sources of noise in ring imaging Cherenkov detectors

A pattern recognition method for the RICH-based HMPID detector in ALICE

Recent results at the -meson region from the CMD-3 detector at the VEPP-2000 collider

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

Status of the LHCb RICH detector and the HPD

Status of the LHCb RICH and hadron particle identification

7 Particle Identification. Detectors for Particle Physics Manfred Krammer Institute of High Energy Physics, Vienna, Austria

A progress report on the development of the CsI-RICH detector for the ALICE experiment at LHC

Study of highly transparent silica aerogel as a RICH radiator

Particle Identification at a super B Factory. FRASCATI WORKSHOP DISCUSSION ON PID

The Aerogel Forward RICH detector for PANDA

AEROGEL AND ITS APPLICATIONS TO RICH DETECTORS

Particle Energy Loss in Matter

An Overview of RICH Detectors From PID to Velocity Spectrometers

Refractive index dispersion law of silica aerogel

The TORCH project. a proposed detector for precision time-of-flight over large areas. Roger Forty (CERN)

Module of Silicon Photomultipliers as a single photon detector of Cherenkov photons

A RICH Photon Detector Module with G-APDs

Measurement of the e + e - π 0 γ cross section at SND

σx=2.5cm, slpx =33mrd

Cherenkov light imaging in particle and nuclear physics experiments

The TRD of the CBM experiment

Hybrid Avalanche Photo Detector for Belle II ARICH detector

CCD readout of GEM-based neutron detectors

arxiv: v1 [physics.ins-det] 20 Jan 2019

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

A study of the angular resolution of the ALICE HMPID CsI-RICH detector

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

Time of Flight Technique

The HERA-B ring imaging Cherenkov system } design and performance

Cherenkov Detector Simulation

arxiv: v2 [physics.ins-det] 17 Jun 2014

Particle Energy Loss in Matter

Aerogel RICH counter for the Belle II forward PID

THE CERN NA62 experiment [1] aims to measure the

Recent results from SND detector

a) National Laboratory for High Energy Physics (KEK), b) Saga University, c) National Kaohsiung Normal University, d) National Taiwan University,

On the reconstruction of Cherenkov rings from aerogel radiators

The Ring Imaging Cherenkov detector of the AMS experiment: test beam results with a prototype

Last Lecture 1) Silicon tracking detectors 2) Reconstructing track momenta

PoS(PhotoDet 2012)008

Kaon Identification at NA62. Institute of Physics Particle, Astroparticle, and Nuclear Physics groups Conference 2015

Information about the T9 beam line and experimental facilities

Determination of parameters of cascade showers in the water calorimeter using 3D-distribution of Cherenkov light

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

Timing and cross-talk properties of BURLE multi-channel MCP-PMTs

Advances in the Micro-Hole & Strip Plate gaseous detector

Status of the PAMELA silicon tracker

Geant4 simulations of the lead fluoride calorimeter

Picosecond Time-of-Flight Measurement for Colliders Using Cherenkov Light

Concepts of Event Reconstruction

Particle Identification of the LHCb detector

Big, Fast, and Cheap: Precision Timing in the Next Generation of Cherenkov Detectors LAPPD Collaboration Meeting 2010

Particle Detectors A brief introduction with emphasis on high energy physics applications

GEM: A new concept for electron amplification in gas detectors

Cherenkov Detectors in Particle Physics. Brad Wogsland University of Tennessee

Study of GEM-like detectors with resistive electrodes for RICH applications

PoS(HIGH-pTLHC)022. The VHMPID detector in the ALICE experiment at LHC. Giacomo Volpe. INFN Bari, Italy

Particle Identification with Disc DIRC at PANDA

A gas-filled calorimeter for high intensity beam environments

The Barrel DIRC Detector for the PANDA Experiment at FAIR

Reconstruction algorithms in the Super-Kamiokande large water Cherenkov detector

GEM-based photon detector for RICH applications

MEIC Central Detector Zhiwen Zhao for JLab MEIC Study Group

arxiv: v1 [physics.ins-det] 3 Dec 2018 Fast Interaction Trigger for the upgrade of the ALICE experiment at CERN: design and performance

Detectors in Nuclear and High Energy Physics. RHIG summer student meeting June 2014

A measurement of the air fluorescence yield

7. Particle identification

The Factors That Limit Time Resolution for Photon Detection in Large Cherenkov Detectors

Novel sensors for Cherenkov counters

Performance of the MCP-PMT for the Belle II TOP counter

Compton Camera. Compton Camera

THE AMS RICH COUNTER

Multi-PMT Optical Module Designs for IceCube-Gen2

PoS(PD07)020. Timing Properties of MCP-PMT. Kenji Inami. Nagoya university, Nagoya, Japan

PoS(HCP2009)042. Status of the ALICE Experiment. Werner Riegler. For the ALICE Collaboration. CERN

Guest Lecture PHY 7361: Harnessing Cherenkov Radiation SteveSekula, 13 April 2010 (created 9 April 2010)

Erratum to: Measurement of φ meson parameters in K 0 LK 0 S decay mode with CMD-2 [Phys. Lett. B 466 (1999) ]

Pion, Kaon, and (Anti-) Proton Production in Au+Au Collisions at s = 62.4 GeV

Electron transparency, ion transparency and ion feedback of a 3M GEM

NA62: Ultra-Rare Kaon Decays

Detector. Matthew Strugari, Dr. Garth Huber 1, Wenliang Li. University of Regina, Regina, SK, S4S 0A2, Canada. August 15, 2016.

Particle production vs. energy: how do simulation results match experimental measurements?

High Momentum Particle IDentification (HMPID) in ALICE. Pusan National University In-Kwon Yoo For ALICE / HMPID Collaboration

TORCH: A large-area detector for precision time-of-flight measurements at LHCb

Measurement of the transverse diffusion coefficient of charge in liquid xenon

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

The R&D study for the KLOD experiment. at IHEP (Protvino) U-70 proton

Transcription:

Nuclear Instruments and Methods in Physics Research A 8 (7) 4 44 www.elsevier.com/locate/nima Results from R&D of Cherenkov detectors at Novosibirsk A.Yu. Barnyakov a, M.Yu. Barnyakov a, K.I. Beloborodov a, V.S. Bobrovnikov a, A.R. Buzykaev a, A.F. Danilyuk b, V.B. Golubev a, V.V. Gulevich a, V.L. Kirillov b, S.A. Kononov a,, E.A. Kravchenko a, A.P. Onuchin a, S.I. Serednyakov a a Budker Institute of Nuclear Physics, Novosibirsk, Russia b Boreskov Institute of Catalysis, Novosibirsk, Russia Available online 6 August 7 Abstract Our group produces silica aerogels with refractive indices of.6. with good optical transparency. The particle identification systems for the KEDR and the SND detectors based on threshold aerogel counters are described. Cosmic test results for the SND counters are presented. The possibility of employing a RICH with a sodium fluoride crystal radiator for p=k separation up to GeV=c momentum is explored. The combined NaF-aerogel radiator is proposed to decrease the minimum working momentum of the RICH below the Cherenkov threshold in aerogel. r 7 Elsevier B.V. All rights reserved. PACS: 9.4.Ka Keywords: Aerogel; Sodium fluoride; Particle identification; Ring imaging; Cherenkov counter. Introduction Cherenkov counters provide a powerful technique for particle identification in the high momentum region where ionization and time-of-flight measurements often cease to work. Silica aerogel has a uniquely low refractive index among solids (less than.). Its use in threshold Cherenkov counters was suggested by Cantin et al. [] in 974. The aerogel was used and is used now in a number of Cherenkov detectors of different types [ 7]. The work on aerogel Cherenkov detectors developed by the Novosibirsk group is presented below. Also we studied the use of a sodium fluoride radiator in a Ring Imaging Cherenkov (RICH) detector to possibly cover momenta below the Cherenkov threshold in aerogel.. Aerogel production The work on the silica aerogel production in Novosibirsk was started in 986 by a collaboration of the Corresponding author. Tel.: +7 8 9 494; fax: +7 8 76. E-mail address: S.A.Kononov@inp.nsk.su (S.A. Kononov). Boreskov Institute of Catalysis and the Budker Institute of Nuclear Physics as a part of the KEDR detector project. The first samples of aerogel were produced in 988 [8]. Since that time significant progress has been made in improving the optical quality of aerogel [9 ]. The following typical values were achieved for hygroscopic aerogel: the light absorption length is 7 m at 4 nm wavelength, the Rayleigh scattering length is 4 cm at 4 nm (Clarity ¼ : :64 mm 4 =cm). Presently, we can synthesize aerogel with a refractive index in the range of.6.7. Aerogel with n4:7 can be produced by a sintering technique. The maximum block dimensions achieved for n ¼ : are mm.. Threshold aerogel counters The ASHIPH method (Aerogel, SHIfter, PHototubes) of Cherenkov light collection was suggested to be used in Cherenkov counters of the KEDR detector in 99 []. The idea is to collect the Cherenkov light on a wavelength shifting bar and transport the re-emitted light to a phototube. This allows one to make longer counters and to use phototubes with smaller photocathodes. Having 68-9/$ - see front matter r 7 Elsevier B.V. All rights reserved. doi:.6/j.nima.7.8.6

A.Y. Barnyakov et al. / Nuclear Instruments and Methods in Physics Research A 8 (7) 4 44 4 done R&D for the KEDR aerogel counters, we chose the combination of PMMA (Polymethylmethacrylat) with BBQ dye (Benzimidazo-Benzisochinolin-7-on) as wavelength shifter and micro-channel plate photomultipliers (MCP PMTs) with multialkali photocathodes [ 6]. The use of the ASHIPH method allowed us to reduce the total area of the PMT photocathodes in the KEDR aerogel system by a factor of... KEDR ASHIPH counters The ASHIPH system of the KEDR detector [9] consists of 6 counters [6]. They are arranged in two layers to reduce losses in geometric acceptance resulting from hits in the shifters. This allows us also to increase essentially the separation power for 8% of the full acceptance, where particles cross both aerogel layers without hitting a shifter. The highly transparent SAN-96 aerogel [9] with a refractive index of. was chosen to enable p=k separation from.6 to : GeV=c momentum. About l of aerogel are used in the system. The test beam results were described in Refs. [7,8]. The p=k separation level obtained in the test for a momentum of : GeV=c amounts to 4:s. The first layer comprising 8 counters was built and installed in the detector in. The installation of the remaining counters is planned for 8... Project of ASHIPH counters for SND For the upgrade of the SND detector for experiments at the VEPP- e þ e collider, a particle identification system based on ASHIPH Cherenkov counters will be installed [,4]. The system must provide p=k separation in the momentum range 87 MeV=c. The aerogel refractive index of. was chosen for this objective. This aerogel is produced by sintering aerogel of a lower refractive index. The absorption length of sintered aerogel amounts to m at 4 nm. The design of the counters is similar to that of the KEDR counters. The whole system consists of 9 counters surrounding the drift chamber. The general layout of a counter is shown in Fig.. A number of tests using cosmic muons with a momentum above GeV=c were carried out with one full-size counter. The measured signal magnitude ranges from 8. to.7 photoelectrons for different points of the counter. 4. Focusing aerogel RICH In a proximity focusing RICH one of the main contributions to the Cherenkov angle resolution comes from the uncertainty in the emission point, which is proportional to the radiator thickness. Recently groups from KEK [] and from Novosibirsk [] started studies of multi-layer aerogel radiators aimed at the reduction of this effect. We have considered two options: Single ring: Cherenkov rings from different layers are focused to a single ring in the detection plane. Multi-ring: There are a few separate Cherenkov rings from different layers. We succeeded in producing a 4-layer aerogel block whose layers had refraction indices matching the projected ones with a good precision []. A Monte Carlo simulation program based on Geant4 has been developed to describe these Focusing Aerogel RICH detectors (FARICH) [,]. The following aerogel radiators were simulated []: single layer with a thickness of mm and n ¼ :7 (SLA), 6-layer single ring () and -layer rings (FAMR- ). A photomultiplier tube with bialkali photocathode and borosilicate window was chosen ðqe max ¼ 4%Þ. The photoelectron collection efficiency and the packing density of the phototubes were taken into account by an overall efficiency of %. The distance between the radiator input face and the photodetector plane was set to mm. The 6- layer focusing aerogel option was demonstrated to identify p and K mesons up to 8 GeV=c momentum [].. Proximity focusing RICH with NaF radiator The possibility of employing a sodium fluoride radiator in a RICH with a gaseous photon detector was discussed [] and tested [6] many years ago. These studies reported 7 A A-A R= 4 48 A d=8 Fig.. The SND ASHIPH counter: () Micro-Channel Plate PMT, () Aerogel, () WLS bar.

4 ARTICLE IN PRESS A.Y. Barnyakov et al. / Nuclear Instruments and Methods in Physics Research A 8 (7) 4 44 a p=k separation with a mm NaF radiator up to. GeV=c. A NaF RICH was used in the CAPRICE balloon-borne experiment in 994 [7]. NaF is also considered for the AMS space-borne experiment as a part of the dual radiator RICH [8]. NaF has the lowest refractive index (n ¼ : at 4 nm) among solids (except aerogels). It allows the Cherenkov light (down to 7 nm wavelength) to refract out for b particles of normal incidence. It is commercially available as monocrystals of cm transverse size with superb transparency for visible and near-uv light. We have studied the feasibility of using the combination of a NaF radiator and photomultiplier tubes with bialkali photocathodes in the same conditions as the aerogel radiators studied earlier. To optimize the thickness of the radiator we plotted the Cherenkov angle uncertainty per track as a function of thickness, obtained for : GeV=c kaons (Fig. ). Though the minimum is located around mm, we chose the mm thickness to keep the amount of material below % of radiation length. Fig. shows the particle velocity resolution at normal incidence for the NaF RICH and the aerogel options as a function of bg. The NaF RICH has a somewhat better resolution for high bg than the single layer aerogel option and about. times worse than the option. The corresponding bg-dependences of the number of photoelectrons are shown in Fig. 4. One can see that the NaF RICH gives twice as many photoelectrons than the RICH. For a angle of incidence the velocity resolution for NaF deteriorates (Fig. ), what can be partially attributed to the decrease in the number of photoelectrons (Fig. 6) when a part of Cherenkov photons is trapped by total internal reflection in the radiator. σ β per track, - 4. 4. NaF mm....9 4 6 7 Fig.. Particle velocity resolution at normal incidence.. NaF mm.8.6 8 σ θ, mrad.4..8.6.4. thickness, mm Fig.. NaF RICH: Cherenkov angle resolution (points) and mean number of photoelectrons (line) versus NaF thickness. 6 4.9 4 6 7 Fig. 4. Number of photoelectrons at normal incidence. The momentum dependence of the p=k separation is shown for normal particle incidence in Fig. 7, and for a incidence angle in Fig. 8. Normally incident p- and K-mesons can be separated at the level of better than s up to GeV=c. At incidence angle this limit drops to : GeV=c. The minimum working momentum is estimated to be about :6 GeV=c.

A.Y. Barnyakov et al. / Nuclear Instruments and Methods in Physics Research A 8 (7) 4 44 4 σ β per track, - 6 4 NaF mm Separation power, σ K threshold in aerogel K threshold in NaF NaF mm σ.9 4 6 7 Fig.. Particle velocity resolution at angle of incidence. 4 6 8 Momentum, GeV/c Fig. 7. p=k separation versus momentum, normal incidence. NaF mm Separation power, σ K threshold in NaF 4 σ K threshold in aerogel 4 6 7 8 9 4 6 7 8 Momentum, GeV/c Fig. 6. NaF ( mm): Number of photoelectrons for different angles of incidence. Fig. 8. p=k separation versus momentum, angle of incidence. The photodetector s spatial resolution is considered to be of secondary importance for these studies. Though, to choose the proper pixelization one should compare the pixel size with the width of the Cherenkov ring in the detector plane. The single photon radius error at b is presented in Table. It shows that the pixel size for the NaF option can be several times larger than for the aerogel options. This greatly reduces the required number of readout channels. We consider NaF to be a good alternative material as compared to aerogels for the p=k separation up to : GeV=c. To get particle identification over the largest

44 ARTICLE IN PRESS A.Y. Barnyakov et al. / Nuclear Instruments and Methods in Physics Research A 8 (7) 4 44 Table Ring radius error for a single photon Radiator SLA mm..6 (-nd ring). NaF mm 7.4 possible momentum range we propose a multiple layer aerogel being combined with NaF. Though further investigations are needed for such a combined radiator. 6. Conclusion s r ðgþ (mm) Our group developed the technique to produce highly transparent aerogel. The system of Cherenkov ASHIPH counters for the KEDR detector, employing wavelength shifters for light collection, was developed. The first layer of the system was installed in the detector. The project of ASHIPH counters for the SND detector has been presented, the first counter was produced and tested with cosmic muons. The mean number of photoelectrons ranges from 8. to.7 for different points of the counter. The use of a sodium fluoride radiator in a proximity focusing RICH with bialkali photocathode PMTs has been investigated. The NaF RICH with a radiator thickness of mm and an expansion gap of mm has been shown to provide p=k separation of better than s up to GeV=c for normal particle incidence and : GeV=c for a angle of incidence. It has been concluded that this choice of radiator is preferable to aerogel below this momentum limit. The use of a combined NaF-aerogel radiator has been proposed to extend the particle identification capabilities to the momentum region below the Cherenkov threshold in aerogel. References [] M. Cantin, et al., Nucl. Instr. and Meth. 8 (974) 77. [] H. Burkhardt, et al., Nucl. Instr. and Meth. 84 (98) 9. [] S. Henning, et al., Phys. Scripta (98) 7. [4] T. Sumiyoshi, et al., Nucl. Instr. and Meth. A 4 (999) 8. [] Y. Miyachi, [HERMES Collaboration], Nucl. Instr. and Meth. A (). [6] T. Bellunato, M. Calvi, C. Matteuzzi, M. Musy, P. Negri, D.L. Perego, Nucl. Phys. Proc. Suppl. (6) 8. [7] A.Yu. Barnyakov, et al., Nucl. Instr. and Meth. A (). [8] V.A. Aksenov, et al., Proceedings of the International Symposium on Position Detectors in High Energy Physics, Dubna, 988, pp.. [9] A.R. Buzykaev, et al., Nucl. Instr. and Meth. A 79 (996) 46. [] A.F. Danilyuk, et al., Nucl. Instr. and Meth. A 4 (999) 46. [] A.F. Danilyuk, et al., Nucl. Instr. and Meth. A 494 () 49. [] A. Onuchin, et al., Nucl. Instr. and Meth. A (99) 7. [] A. Buzykaev, et al., Nucl. Instr. and Meth. A 79 (996) 4. [4] A.R. Buzykaev, et al., J. Non-Cryst. Solids (998) 8. [] M.Yu. Barnyakov, et al., Nucl. Instr. and Meth. A 49 (998) 84. [6] M.Yu. Barnyakov, et al., Nucl. Instr. and Meth. A 4 () 6. [7] A.Yu. Barnyakov, et al., Nucl. Instr. and Meth. A 478 (). [8] A.Yu. Barnyakov, et al., Nucl. Instr. and Meth. A 494 () 44. [9] V.V. Anashin, et al., Nucl. Instr. and Meth. A 478 () 4. [] K.I. Beloborodov, et al., Nucl. Instr. and Meth. A 494 () 487. [] S. Korpar, et al., Nucl. Instr. and Meth. A () 64. [] A.Yu. Barnyakov, et al., Nucl. Instr. and Meth. A () 7. [] A.Yu. Barnyakov, et al., Proceedings of SNIC 6, econf C64 (6) 4. [4] A.Y. Barnyakov, et al., Proceedings of SNIC 6, econf C64 (6) 9. [] R. Arnold, et al., Nucl. Instr. and Meth. A 7 (988) 466. [6] F. Piuz, et al., Development of a fast RICH detector using a MWPC at low gain with PAD readout and a NaF radiator, Presented at 4th Topical Seminar on Perspectives for Experimental Apparatus for High-energy Physics and Astrophysics, San Miniato, Italy, 8 May June 99. [7] G. Barbiellini, et al., Nucl. Instr. and Meth. A 7 (996) 69. [8] F. Barao, et al., The ring imaging Cherenkov detector (RICH) of the AMS experiment, Talk at the 9th International Cosmic Ray Conference, Pune, India, August, astro-ph/68.