DGCU165-5B 36 W. Five-Burner Cooktop

Similar documents
48 Dual Fuel Range with Grill

36 Dual Fuel Range with Griddle

48 Dual Fuel Range with Grill

GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace

Repair Parts List DUEL FUEL RANGE MODEL NUMBER SVD48600BC. When requesting service or ordering parts, always provide the following information:

PARTS MANUAL Gas Furnace F9MAC, G9MAC

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

INFRARED THERMOMETER Model : TM-959

Fo r u s e w i t h Br o i l m a s t e r Pr e m i u m Ga s Gr i l l s. B Page 1

FOREMAN ASSEMBLY / OWNER S MANUAL

SRP RESIDENTIAL GARAGE HEATERS

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008

FOR CAN-AM ATV s P/N ASSEMBLY / OWNERS MANUAL

Automatic and Manual Safety Pilot Kits

PARTS MANUAL Gas Furnace F8MXN, F8MXL, G8MXN, G8MXL

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL

PUSH TUBE STANDARD DUTY

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

Cookers. Always fresh. Always delicious.

Project. Project Location. Catalog #

ASSEMBLY / OWNER S MANUAL

HT600 Dat e Code: 2 - HT MW Purchase Date: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE. All Rights Reserved

PULVI-MULCHER/SEEDBED MAKER INDEX. Pulvi-Mulcher. M Models & 10 4

PLOW MOUNT KIT FOR YAMAHA VIKING P/N ASSEMBLY / OWNERS MANUAL. Application PLOW PUSH FRAME NO or

E-Invoice. Total. ibuild,inc. Subtotal. Sales Tax (0.0%) 3000 S Jamiaca Ct Suite 210 Aurora, CO Date 12/2/

ATV WP2 FRONT MOUNT PUSH TUBE

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

nufacturing Company, L.P San Felipe, Suite

USER MANUAL REFLEX SIGHT. Ultra Shot Z Series. English / Francais / Español / Deutsch

www. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION

Commercial Generator Parts Catalog. PROTEC Series

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

THE MASTER 2 SET UP AND OPERATION MANUAL TABLE OF CONTENTS

zehnder stratos CS CS CS CSW CSW Product Overview Model Code (example)

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

FOR POLARIS ATV s P/N ASSEMBLY / OWNERS MANUAL

CPI SNOW PLOW KIT ASSEMBLY INSTRUCTIONS

s s t L e 46 APACHE TRACK SYSTEM ALUMINUM FRAME LINK LARGER FOOTPRINT 14.4 CM INTERMEDIATE WHEELS OVERSIZE 25.4 CM CORNER WHEELS

Introducing Our Newest Inspiration!

DRIFTER PLOW-IN-A-BOX ASSEMBLY / OWNER S MANUAL

PARTS LIST GAS BOILERS MODELS:

Service Parts. AMV9*XA Upflow/Horizontal/Two- Stage/Variable Speed 90% AFUE Gas Furnace. Models and manufacturing numbers in this manual

Type M4 - SON - SO - MS

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Hudevad P100. Technical datasheet

10-year industry best core warranty. 2-year warranty on balance of unit.

SSi Super Systems Inc.

Parts List with Exploded Views

Training Guide. Coastal Environmental Systems, Inc.

ENVIRONMENTALLY SOUND R 410A REFRIGERANT

DRIFTER PLOW-IN-A-BOX

A.R.M. 52 PLOW With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER BLACK MODEL NUMBER GRAY. Owner s Manual

GB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min

REPAIR PARTS. GMVC 96% ECM Up Flow Furnace. This manual is to be used by qualified technicians only.

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

INF195 Infrared Thermometer

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

FFHT1831QE2 FFHT1831QM2 FFHT1831QP2 FFHT1831QQ2 FFHT1831QS2

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

REPAIR PARTS. GMEC 96% ECM Up Flow Furnace

Operating Instructions for Digital Manometer. Model: MAN-SD

Jumbo Cross Beam Ionizer

Field Pro Operation and Installation Manual

Quantum. Quantum light body. Quantum masks

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

Installation instructions, accessories. Snow chains

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

Clausing Industrial, Inc. Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses

3000 Residential 4000 Commercial Aluminum Fence Systems Lifetime Limited Warranty

Coflore Agitated Cell Reactor

GMVC 80% Variable Speed Communicating Furnace

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details)

Spare parts list UC-S

Must Read Before Installation TadPoleTM Safety and Warnings

WE RE HERE TO HELP: 1 (844) LIGHTCLOUD

Main Catalogue. Edition 23, chapter minirack: Phase-out product!

Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses

Report No 247/ This Report consists of 41 pages

AME Model. (1) Rated flow (l/min (ANR)) Port size (Nominal size B) Weight (kg)

Dual Red or Green Electronic Dot Sight Instruction Manual

REPAIR PARTS. *MVC95 Variable Speed Furnace

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature

Eppendorf SmartBlock. Instructions for use

1073 Series One Way Snowplow owner s manual. Read before operating. Important safety and operation instructions inside.


Melton Series. Owners Manual. Lab Centrifuge. Model # s A C, A C, B C, B C, C C, C C, D C, D C

Altazimuth Mount. Altazimuth Mount

13 PRAIRIE 1A A LOW E R B LOW E R C UPPER D UPPER E UPPER UNIT B UNIT A

REPAIR PARTS. GMEC 96% EEM Up Flow Furnace. This manual is to be used by qualified technicians only.

MASTER PARTS LIST CONVECTION OVENS

confront fury

Cabinets NOVASTAR. Overview Cabinets Wall mounted cases Accessories for cabinets and wall mounted cases 3.

Materials Available Yellow Brass Antiqued Yellow Brass Bronze Antiqued Bronze Aluminum

PARTS LIST GAS BOILERS MODELS: CG320 (E) CG325 (E) CG330 (E)

High Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters

REPAIR PARTS. *CVC95 C'Flow Variable Speed Furnace ACVC950714CXBA ACVC950915DXBA GCVC950714CXBA GCVC950915DXBA

Transcription:

Standard Features & Accessories All models include Dimensioned fit the majority of similarly sized cookp cuuts Sealed burners with brass flame ports and porcelain/cast iron burner caps Burners mounted in durable, easy clean ceramic glass Heavy-duty stainless steel control knobs with childproof, push--turn safety feature 4B model includes Four burners o Left front 14,000 BTU high/2,000 o Left rear 12,000 BTU high/1,700 o Right rear 8,000 BTU high/1,200 o Right front 6,000 BTU high/950 30 /36 /45 W. Ceramic 5B model includes Five burners o Left front 12,000 BTU high/1,700 o Left rear 10,000 BTU high/1,500 o Center 14,000 BTU high/2,000 o Right rear 8,000 BTU high/1200 o Right front 6,000 BTU high/950 6B model includes Six burners o Left front 12,000 BTU high/1,700 o Left rear 8,000 BTU high/1200 BTU low o Left center 10,000 BTU high/1,500 o Right center 14,000 BTU high/2,000 o Right front 8,000 BTU high/1200 BTU low o Right rear 6,000 BTU high/950 Model Options 30 W. Four-Burner 36 W. Five-Burner 45 W. Six-Burner FINISH DETAILS FOR ALL MODELS Stainless Steel/Black (SB) o Stainless steel trim, control panel, and knobs. o Black glass, grates, and knob grips. Stainless Steel/White (SW) o Stainless steel trim, control panel, and knobs. o White glass. o Gray grates and knob grips. Brass Trim Option (BR) knobs. Brass components have a durable protective coating for maintenance-free normal use. ORDERING INSTRUCTIONS First specify model number, and then color code (SS). If ordering optional brass trim, specify code at end (SSBR). If ordering optional LP conversion, specify code at end (SSBRLP).

Please see Installation Notes & Accessories for important installation information, including conversion kits. Dimensions & Specifications PRODUCT DIMENSIONS 30 /36 /45 W. Ceramic 30 W. Four-Burner 36 W. Five-Burner 45 W. Six-Burner 30-3/4 (78.1) 36-3/4 (93.3 cm) 30-3/4 (78.1) 36-3/4 (93.3 cm) 30 W. Models 36 W. Models 45 (114.3 cm) 45 (114.3 cm) 45 W. Models SIDE VIEW Overall width 30-3/4 (78.1 cm) 36-3/4 (93.3 cm) 45 (114.3 cm) Overall height (from botm) Overall height (from p of grate botm) Overall depth (from rear)

Dimensions & Specifications 30 /36 /45 W. Ceramic CLEARANCE DIMENSIONS 13 max. (33.0 cm) 18 min. (45.7 cm) 8 min. (20.3 cm) 36 min. (91.4 cm) 36 min. (91.4 cm) 3-1/8 (7.9 cm) 2-1/2 (6.4 cm) Minimum clearances from adjacent combustible construction Sides 8 (20.3 cm) Rear 2-1/2 (6.4 cm) min. Within 8 (20.3 cm) side clearance; wall cabinets no deeper than 13 (33.0 cm) Must be minimum 18 (45.7 cm) above counterp Wall cabinets directly above cookp must be minimum 36 (91.4cm) above the counterp. 1. The cookp may be installed directly existing base cabinets. 2. The cookp cannot be installed directly adjacent sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36 (91.4 cm) high. There must be a minimum of 8 (20.3 cm) side clearance from the cookp such combustible surfaces above the 36 (91.4 cm) counter height. 3.Within the 8 (20.3 cm) side clearance combustible vertical surfaces above 36 (91.4 cm), the maximum wall cabinet depth must be 13 (33.0 cm) and wall cabinets within this 8 (20.3 cm) side clearance must be 18 (45.7 cm) above the 36 (91.4 cm) high counterp. 4. Wall cabinet above the cookp must be a minimum of 36 (91.4 cm) above the counterp for a full width of the cookp. This minimum height requirement does not apply if a hood is installed over the cooking surface. 5. A 120-volt wall receptacle should be located approximately 6 (15.2 cm) below the counterp cuut and 12 (30.5 cm) from the right side of the cuut. The botm of the hood should be 30" (76.2 cm) min. 36 (91.4 cm) above the counterp. This would typically result in the botm of the hood being 66 (167.6 cm) 72 (182.9 cm) above the floor. Refer the hood installation instructions for further information. Warning The use of cabinets for srage above the appliance may result in a potential burn hazard. If a cabinet srage is be provided the risk can be reduced by installing a hood that projects horizontally a minimum of 5 (12.7 cm) beyond the botm of the cabinets.

UTILITY REQUIREMENTS Installation Requirements ACCESS REQUIREMENTS 30 /36 /45 W. Ceramic GAS Must be ordered from the facry either natural gas or LP/propane (DGCU models are not field convertible). Specify LP after model number and color code, for example, SSLP Accepts standard residential 1/2 (1.3 cm) ID gas service line Gas manifold pressure Natural gas 5.0 W.C.P. LP/propane 10.0 W.C.P. 30 W. Four-Burner Cuut opening 36 W. Five-Burner Cuut opening 45 W. Six-Burner Cuut opening ELECTRICAL 4-foot (121.9 cm) cord included with cookp 3-wire with ground/ 3-prong plug 120 V/60 Hz Max. amp usage 2.0 *If electrical power is not supplied or is interrupted, the open p burners can be lit manually with a match. 1-1/16 (2.7 cm) 28-3/4 (73.0 cm) min. 29-7/8 (75.9 cm) max. 30 W. Cuut 27 (68.6 cm) 1-1/16 (2.7 cm) 2-1/4 36 W. Cuut 15/16 (2.4 cm) 34-1/2 (87.6 cm) min. 35-7/8 (91.1 cm) max. 33 (83.8 cm) 15/16 (2.4 cm) 2-1/4 45 W. Cuut 7/16 (1.1 cm) 42-7/8 (108.9 cm) min. 44-1/8 (112.1 cm) max. 42 (106.7 cm) 7/16 2-1/4 (1.1 cm) PLUMBING Not applicable 29-1/8 (73.9 cm) 34-7/8 (88.6 cm) 42-7/8 (108.9 cm) 30 W. Cuut 36 W. Cuut 45 W. Cuut Cuut width 28-3/4 (73.0 cm) min. 34-1/2 (87.6 cm) min. 42-7/8 (108.9 cm) min. 29-7/8 (75.9 cm) max. 35-7/8 (91.1 cm) max. 44-1/8 (112.1 cm) max. Cuut height 2-3/4 (7.0 cm)* Cuut depth (52.1cm) max. Surface burner rating Left front 14,000 BTU Nat. (4.1 kw)/ 12,000 BTU Nat. (3.5 kw)/ 12,000 BTU Nat. (3.5 kw)/ 13,500 BTU LP (4.0 kw) 11,500 BTU LP (2.8 kw) 11,500 BTU LP (2.8 kw) Left rear 12,000 BTU Nat. (3.5 kw)/ 10,000 BTU Nat./LP (2.9 kw) 8,000 BTU Nat./LP (2.1 kw) 11,500 BTU LP (2.8 kw) Right front 6,000 BTU Nat./LP (1.8 kw) 6,000 BTU Nat./LP (1.8 kw) 8,000 BTU Nat./LP (2.1 kw) Right rear 8,000 BTU Nat./LP (2.1 kw) 8,000 BTU Nat./LP (2.1 kw) 6,000 BTU Nat./LP (1.8 kw) Center 14,000 BTU Nat. (4.1 kw)/ 10,000 BTU Nat./LP (2.9 kw) 13,500 BTU LP (4.0 kw) Right center 14,000 BTU Nat. (4.1 kw)/ 13,500 BTU LP (4.0 kw) *Top of grate support should be 1-1/8 (2.8 cm) above counterp. There must be a 1 (2.5 cm) clearance undercounter on all sides of the cookps.

30 /36 /45 W. Ceramic Compliance Information WARRANTY INFORMATION* One-year full warranty complete product Five-year limited warranty surface burners Ninety-day limited warranty cosmetic parts such as glass, painted, and decorative items * For complete warranty see Use & Care Guide. Warranty valid on Viking products shipped within the United States and Canada.