DEVELOPMENT OF AN AIR BASED SORPTION COLLECTOR

Similar documents
Basic Principles of an Adsorption Heat Storage System

NEGST. New generation of solar thermal systems. Advanced applications ENEA. Comparison of solar cooling technologies. Vincenzo Sabatelli

Impact of degradation on system performance

FORSCHUNGS- UND TESTZENTRUM FÜR SOLARANLAGEN. Institut für Thermodynamik und Wärmetechnik Universität Stuttgart

Simplified Collector Performance Model

First tests on a solid sorption prototype for seasonal solar thermal storage.

DELIVERABLE 5.3 Report on Predictive control system development and performance tests 1

INVESTIGATIONS ON SOLAR THERMAL PROCESS HEAT INTEGRATION WITH PARABOLIC TROUGH COLLECTORS

FIELD TEST OF WATER-STEAM SEPARATORS FOR THE DSG PROCESS

SIMULATION OF THERMO-MECHANICAL STRAIN IN EXTRUDED POLYMER ABSORBERS FOR SOLAR THERMAL COLLECTORS

HEAT LOSS SENSITIVITY ANALYSIS OF DIFFERENT LINEAR FRESNEL COLLECTOR RECEIVER GEOMETRIES

Test Procedures for Sorption Chillers Based on the Working Mode

PERFORMANCE OF THE ABSORPTION PROCESS IN A SEASONAL SORPTION HEAT STORAGE PROTOTYPE

Project 2. Introduction: 10/23/2016. Josh Rodriguez and Becca Behrens

Pilot applications for Egypt related end-users

COMBINED MEASUREMENT OF THERMAL AND OPTICAL PROPERTIES OF RECEIVERS FOR PARABOLIC TROUGH COLLECTORS

UNIT FOUR SOLAR COLLECTORS

Assessing energy performance of buildings using modeling based on existing administrative and topographical data

1 / 17. TÜV Rheinland (Shanghai) Co., Ltd Solar/ Fuelcell Technologies. Test Report

About peer review missions related to data management

Thermal Analysis of Solar Collectors

Building energy controlled by the reflective facades

HiLumi LHC FP7 High Luminosity Large Hadron Collider Design Study. Milestone Report. Cryogenic Scenarios for the Cold Powering System

Δ q = ( ψ L) HDH (1) here, Δq is the additional heat transfer caused by the thermal bridge, Ψ and L are the linear thermal transmittance and length of

Collector test according to EN ,2 : 2006

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Collector test according to EN ,2:2006

The INSPIRE Building Model for Energy Applications

Design of Standing Wave Type Thermoacoustic Prime Mover for 300 Hz Operating Frequency

INSTITUTE FOR TECHNICAL PHYSICS (ITEP) CRYOGENICS

Available online at ScienceDirect. Energy Procedia 57 (2014 ) ISES Solar World Congress

WP4.D2 DRAFT PROCEDURES AND RESOURCE DOCUMENTS Subtask 1: Advanced Collectors Dissemination level: Public

Daylight and Sun Study

V 12: Miniature photoelectric switches in M 12 housings

Description of ScenoCalc (Solar Collector Energy Output Calculator), a program for calculation of annual solar collector energy output

Executive Council Meeting 118, Hotel Villa Madruzzo, Trento, Italy

Product documentation

Collector test according to EN ,2:2006

Collector test according to EN ,2:2002

Cooling of Electronics Lecture 2

Performance Evaluation of Air-Based Heat Rejection Systems

Stationary Booster Reflectors for Solar Thermal Process Heat Generation

Experimental investigation of the performance of a Parabolic Trough Collector (PTC) installed in Cyprus

SIZZLING SHOWCASE: TEMPERATURE STUDY OF THE ADELL McMILLAN GALLERY AT THE UNIVERSITY OF OREGON ERB MEMORIAL UNION

Pipex px SUSTAINABLE SYSTEMS

CEA Saclay Seminar. Cryogenic Research for HTS Transmission Cables in Korea

TÜV Rheinland PTL, LLC 2210 South Roosevelt Street Tempe, AZ Test Report

Principles of Solar Thermal Conversion

TREES Training for Renovated Energy Efficient Social housing

COVENANT UNIVERSITY NIGERIA TUTORIAL KIT OMEGA SEMESTER PROGRAMME: MECHANICAL ENGINEERING

Introduction. CNS Prototype was made under the frame of the ANSTO CNS project.

1/54 Circulation pump, safety valve, expansion vessel

New web-site tools for mapping of air quality on different scales in Europe illustrative examples of near real time applications: UK & US

How to Determine the Long-Term Performance of Vacuum Insulation Panels

MEMORANDUM OF UNDERSTANDING FOR THE ESTABLISHMENT OF A CARPATHIAN INTEGRATED BIODIVERSITY INFORMATION SYSTEM

HEAT LOSS CHARACTERISTICS OF A ROOF INTEGRATED SOLAR MICRO-CONCENTRATING COLLECTOR

It is easiest to create a table of values and calculate the energy consumption piece by piece.

Resolutions from the Tenth United Nations Conference on the Standardization of Geographical Names, 2012, New York*

New European Accelerator Project EuCARD: Work Package on High Field Magnets

3D-SDI contribution to energy-efficient cities 3D CityModels for Energy Demand Simulation

CALCULATIONS OF SEMI-SPHERICAL SOLAR COLLECTOR WITH REFLECTOR

CHAPTER 3 PROBLEM DEFINITION AND OBJECTIVE

PART A Project summary

Geographical Information Systems Energy Database Report. WP1 T1.3- Deliverable 1.9

ElectroSpray Deposition system as sample preparation for NP analysis by EM & HRMA as on line analysis technique for the smallest NP range

VALIDATION OF A TRNSYS SIMULATION MODEL FOR PCM ENERGY STORAGES AND PCM WALL CONSTRUCTION ELEMENTS

Experimentally Identify the Effective Plume Chimney over a Natural Draft Chimney Model

COUNCIL OF THE EUROPEAN UNION. Brussels, 2 May /14 CULT 68

Solar Control in Traditional Architecture, Potentials for Passive Design in Hot and Arid Climate

PoS(FNDA2006)033. Radiography Using Fission Neutrons. Thomas Bücherl. Christoph Lierse von Gostomski

Plasma-Sprayed Coatings for Solar Receivers

A Comparison Between Experimental and Statistical Data of the Solar Potential at an Optimal Angle of an Inclined Surface for the City of Varna

NATIONAL ELECTRICITY FORECASTING REPORT UPDATE FOR THE NATIONAL ELECTRICITY MARKET

COMBINATION OF TAGUCHI METHOD AND ARTIFICIAL INTELLIGENCE TECHNIQUES FOR THE OPTIMAL DESIGN OF FLAT-PLATE COLLECTORS

Coolant. Circuits Chip

Development of high-efficiency Stirling cryocoolers for high temperature superconducting motors

Mercury Stack Monitor SM-4

On-line demonstrator experiment implemented CODE: DEL-040 VERSION: 01

MODELLING AND SIMULATION OF FAÇADE INTEGRATED ACTIVE COMPONENTS WITH MATLAB/SIMULINK. Passive House Institute, Darmstadt, Germany

PREDICTION OF OUT-OF-PLANE FAILURE MODES IN CFRP

Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions

SWEDISH SDI DEVELOPMENT & IMPLEMENTATION OF INSPIRE

Thermal conversion of solar radiation. c =

ANALYSIS OF THERMAL STRESSES OF SOLAR PARABOLIC TROUGH COLLECTOR FOR SOLAR POWER PLANT BY FEM

The Swedish National Geodata Strategy and the Geodata Project

Development of a prototype system for seasonal solar heat storage using an open sorption process

Collector test according to EN ,2:2006

econtentplus GS Soil

A PRELIMINARY MODEL OF USER BEHAVIOUR REGARDING THE MANUAL CONTROL OF WINDOWS IN OFFICE BUILDINGS

Utilization of Egyptian Research Reactor and modes of collaboration

EUROPEAN COMMISSION SEVENTH FRAMEWORK PROGRAMME THEME SME Research for benefits of SME Association

Simulation Report System : Monosorp

MPC-D403 MPC-D404. Ultra-small Peltier Coolers. High impedance Low control current High power efficiency

Trends in development of advanced porous materials for thermal adsorption storage of heat. Jochen Jänchen

OPPA European Social Fund Prague & EU: We invest in your future.

equator COMBINATION OVENS

Performance Assessment of PV/T Air Collector by Using CFD

In situ Geothermal Lab Groß Schönebeck

Building Envelope Requirements Overview Page 3-4

DEVELOPMENT OF COOLING LOAD TEMPERATURE DIFFERENTIAL VALUES FOR BUILDING ENVELOPES IN THAILAND

Transcription:

DEVELOPMENT OF AN AIR BASED SORPTION COLLECTOR within the EU project INSPIRE Björn Nienborg, Gerrit Füldner Fraunhofer Institute for Solar Energy Systems ISE Task 53, 2 nd Expert Workshop Västeras, 7 th /8 th October 2014 www.ise.fraunhofer.de

AGENDA The inspire project Sorption collectors Design of an air-based sorption collector for façade application Measurements of a prototype Simulation results 2

Inspire project Development of renovation packages to reduce energy consumption of existing buildings to <50kWh/m²/yr building envelope: 4 façade kits, 2 roof kits energy distribution: chilled/heated ceilings Normative measures, dissemination, 24 project partners (coordinated by EURAC) 4 years 3

Sorption collector why that? Why integrate sorption tubes into solar collectors Simplified installation No high temperature circuit required Resulting peculiarities Regeneration during times of insolation, ad/bsorption during times without insolation daily cycle!!! Cold production during non-insolation hours!!! Heat rejection partly shifted non-insolation times ( low ambient temperature) 4

Basic design options water based flat plate collector Sorption tube Integration with heat exchangers 5 Hydraulic connection Collector integration Source: CCT

Basic design options air based vacuum tube collector Sorption tube Integration with heat exchangers 6 Air flow and integration Source: CCT

Air based vaccuum tube collector design details Reflector 7 Reactor HX Evaporator/Condenser HX Source: Fraunhofer ISE

Collector measurements - temperatures 8 1 collector consists of 4 reactor tubes, 0.89m² aperture area Source: Fraunhofer ISE

Collector measurements - Power -120 W > 5h 9 Source: Fraunhofer ISE

Simulation results 20m² office room, 2.7 m² aperture area in the facade SFcool [%] Stockholm Stuttgart Rome East 40 South 32 West 31 East 33 South 23 West 28 East 27 South 21 West 27 SS cccc = Q SS_cccc Q ccccccc 10

Simulation results 20m² office room, 2.7 m² aperture area in the facade SFcool SEERcool Stockholm Stuttgart Rome [%] [-] East 40 6.9 South 32 5.6 West 31 6.4 East 33 6.4 South 23 5.1 West 28 6.9 East 27 6.8 South 21 6.0 West 27 7.9 SS cccc = Q SS_cccc Q ccccccc EEE cccc = Q SS_cccc Q SS_eeeeeeee 11

Simulation results 20m² office room, 2.7 m² aperture area in the facade SFcool SEERcool η cccc [%] [-] [%] Stockholm Stuttgart Rome East 40 6.9 19 South 32 5.6 11 West 31 6.4 14 East 33 6.4 20 South 23 5.1 11 West 28 6.9 16 East 27 6.8 18 South 21 6.0 12 West 27 7.9 20 SS cccc = Q SS_cccc Q EEE cccc = Q Q η cccc = Q ccccccc SS_cccc SS_eeeeeeee SS_cccc Q SS_sssss 12

Conclusions Systems with vacuum tubes are advantageous over flat plate collector Air based system reduces number of components (no drainback system, no dry cooler) Improvement of electric efficiency required reduction of pressure drop in condensor/evaporator part Orientation of sorption collector needs to fit load Promising results in terms of thermal performance 13

Acknowledgements The research leading to these results has received funding from the European Union s Seventh Programme for research, technological development and demonstration under grant agreement No. 314461 inspire. The European Union is not liable for any use that may be made of the information contained in this document which is merely representing the authors view. The authors wish to express their gratitude to Swedish Research Council Formas for the financial support to the research leading to the results presented. In addition the authors would like to thank the employees of ClimateWell for building the prototype according to the presented design, and Parker for supplying the aluminum lamella heat exchangers free of cost. www.inspirefp7.eu 14

Thank you for your attention! Fraunhofer Institute for Solar Energy Systems ISE Björn Nienborg www.ise.fraunhofer.de bjoern.nienborg@ise.fraunhofer.de 15