ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL

Similar documents
ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL

A L I O N Technical Center. Test Report

RIVERBANK ACOUSTICAL LABORATORIES

A L I O N Technical Center. Test Report. Port Coquitlam, British Columbia, Canada

RIVERBANK ACOUSTICAL LABORATORIES

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION OF CLASSICTONE 700 ASTM C Type E Mounting. Test Number 2

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

Testing Procedure: AS ISO

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 7MM TESTED WITH A 20MM AIR GAP IN A REVERBERATION ROOM.

Sound Absorption Test Intertek. kraft paper softwall + softblock modular system. m o l o d e s i g n, l t d

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 24MM TESTED WITH NO AIR GAP MEASURED IN A REVERBERATION ROOM.

stylegreen Iceland Moss / Reindeer Moss of the company FlowerArt

LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS

Fabric Dazzle 6086 Manufacturer Carnegie Fabrics

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION COEFFICIENTS OF OSCAR EVO-PANELS

Renolit stretch ceilings

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time

Measurement of Acoustic Properties of light weight concrete SL-Deck

Test Report. RI Acoustic Lab. Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier. 20 Feb. 07

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm

TFI Report Sound Absorption Impact Sound Insulation

Fabric REFLECTACOUSTIC

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation

Fabric ALEX. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/09

Fabric Sport. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/02

Fabric STREAMER pro. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/04

Consultancy Report Ref: 9383-R01

Fabric VELOS STRATO. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/10

Curtain fabric type Ace Manufacturer Kvadrat A/S

Fabric Zetacoustic. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/07

Fabric UDINE. Measurement of sound absorption according to EN ISO 354. Test Report No. M102794/32

TFI Report Sound Absorption Impact Sound Insulation

Fabric TWIST MELANGE Manufacturer Gabriel A/S

Fabric Medley Manufacturer Gabriel A/S

Fabric Corsica. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/16

Fabric Umbria III R. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/13

DELTA Test Report. Measurement of Sound Absorption for AqFlex ON, one Sample as a discrete Object. Performed for Flex Acoustics

Measurement of sound absorption coefficient for Fraster felt SpaceCover

Fabric XPRESS + PU-foam Manufacturer Gabriel A/S

Roller blind fabric PRIMACOUSTIC R

INVESTIGATIONS INTO THE PERFORMANCE OF THE REVERBERATION CHAMBER OF THE INTEGRATED ACOUSTICS LABORATORY. A Thesis Presented to The Academic Faculty

Laboratory for Acoustics

MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE

REPORT N CR

Calcul des coefficients d'absorption alpha sabine

The information included in the following report presents the results of sound pressure and sound power testing.

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method

REPORT. Client. Test object. Date of testt. Results. Rönnåsgatan 5B Ulricehamn. (7 appendices) content of the

Part 2: Methods for special reverberation test rooms

Laboratory for Acoustics. Determination of the sound absorption (reverberation room method) of curtains, manufacturer Vescom BV

Laboratory for Acoustics. Determination of the sound absorption (reverberation room method) of Airpanel, manufacturer Texdecor

Study of Wenger Audience Seating Chair Absorption. Ron Freiheit

Evaluation of standards for transmission loss tests

ISO INTERNATIONAL STANDARD

ISO 354 INTERNATIONAL STANDARD. Acoustics Measurement of sound absorption in a reverberation room

Development of a small-scale reverberation room

Page 1 of 10 pages Appendix, 5 pages Report no.: P Glostrup, October 12th 2012 Project: Claimant:

LABORATORY MEASUREMENTS OF THE REDUCTION OF TRANSMITTED IMPACT NOISE PANETTI OVERLAID BY CONCRETE FLOORING

Technical Report. Project. The Laboratory Determination of The Random Incidence sound Absorption Coefficient of VertiQ Panels.

Report. Laboratory for Acoustics

ISO 3741 INTERNATIONAL STANDARD

Laboratory for Acoustics

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063

Report. P.O. Box 70 NL 5700 AB Deurne The Netherlands Report number: A E-RA Date: 12 februari 2014 TS/TS/JW/A E-RA

Laboratory and In Situ Sound Absorption Measurement under a Synthetized Diffuse Acoustic Field: a Case Study on Five Materials

Technical Note. Measurement of Sound Absorption for Flex Acoustics AqTube. Performed for Flex Acoustics. TC Project no.: T Page 1 of 7

Yalıtım Kontrol Koruma. Insulation Control Protection

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Paseo Recoletos, nº Madrid TEST REPORT

R & D AKUSTIKA * SIA. Test Report of laboratory Sound Insulation measurements Nr. 569 / 2011 AL 8.4. CUSTOMER: AEROC AS (Estonia)

Report. Laboratory for Acoustics

Laboratory for Acoustics. Determination of the sound insulation of sliding door constructions, manufactured by Metaflex

Cat# LED Linear High Bay 100W

CERTIFICATE OF CALIBRATION

Report. Laboratory for Acoustics Determination of the sound absorption (reverberation room method) of different wired mats, manufacturer Rockwool

Standard ECMA-108 3rd Edition - December Measurement of High-frequency Noise emitted by Information Technology and Telecommunications Equipment

THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES

ISO INTERNATIONAL STANDARD

Test Results: Results of the test period on 06/19/16 using the Equivalent CTS Method: Thermal transmittance at test conditions (U s ):

TFI Report Impact Sound Insulation

CERTIFICATE OF CALIBRATION

TFI Report Impact Sound Insulation

Investigations on real-scale experiments for the measurement of the ISO scattering coefficient in the reverberation room

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA. EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562

Standard Test Method for Thermal Conductivity of Refractories 1

Electrical Parameter. Measurement and Test Report for. MaxGreen LED Ltd.

Determination of sound absorption coefficient in impedance tubes according to ISO (2 appendices)

Addendum to ARI Standard , Air Terminals September 2002

CERTIFICATE OF CALIBRATION

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Standard Practices for Air Speed Calibration Testing

Review of Anemometer Calibration Standards

Reflectec Thermal Fabric & Reflectec Fiberboard

EXPERIMENTAL VERIFICATION OF THE EUROPEAN METHODOLOGY FOR TESTING NOISE BARRIERS IN SITU: SOUND REFLECTION

Report No: NCTL NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 12/14/15

Micro-perforated sound absorbers in stretched materials

An examination of some aspects of the use of ISO 140 Part 4 and 7 in field measurements.

Transcription:

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT -SA6712/-SA6713 Revision 0 Subject: Sound Absorption Test Date: 17 May 2016 Contents: on Sound Absorption Data, One-third Octave bands Sound Absorption Coefficients, One-third Octave bands Sound Absorption Average (SAA) Noise Reduction Coefficient (NRC) 4666 MINGLE, Unbacked Type A Mounting, Specimen Plan Area 72 ft 2 for Carnegie ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY is NVLAP-Accredited for this test procedure under Lab Code 100286-0 National Institute of Standards and Technology National Voluntary Laboratory Accreditation Program Reports may be reproduced freely if in full and without alteration. Results apply only to the unit tested and do not extend to other same or similar items. The term NVLAP or the NVLAP logo does not denote product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. 1301 Arrow Point Drive Cedar Park, TX 78613 Phone: 512-531-6400 Fax: 512-531-6500 www.ets-lindgren.com email: acousticlab@ets-lindgren.com

-SA6712/-SA6713 Revision 0 Page 2 of 7 INTRODUCTION The sound absorption coefficient is a property of the material composing the surface. It is ideally defined as the fraction of the randomly incident sound power absorbed by the surface. [ASTM C 423] APPLICABLE STANDARDS ASTM C 423 09a Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method ASTM E 795-05(2012) Standard Practices for Mounting Test Specimens during Sound Absorption Tests ANSI/ASA S1.11-2014/Part 1 / IEC 61260-1:2014 Electroacoustics Octave-band and Fractional-octave-band Filters Part 1: Specifications TEST SPECIMEN The test specimen consisted of a 2743 mm in length by 2438 mm in width [108 by 96 inches] fabric application that was manufactured, submitted for test, and designated "4666 MINGLE, Unbacked, Type A Mounting by Carnegie of Rockville Center, NY. Quoted test specimen weight on a 1473 mm [58 inches] wide roll was xx kg/m [YY ounces per linear yard]. In order to test the acoustic characteristics of the fabric for a specific application, two (2) separate absorption tests were conducted. As a basis, one (1) layer of Johns Manville Spin-Glas Board, density 48 kg/m 3 [3.0 pounds per cubic foot] was placed on the Reverberation Room floor in a Type A Mount. The dimensions of this specimen s component were 2743 mm in length by 2438 mm in width by 52 mm in depth [108 by 96 by 2 inches]. This component served as the underlayment for the fabric application. This underlayment was tested with (Test Number -SA6713) and without (Test Number -SA6712) the fabric application installed. The plan area for both tests was 6.7 m 2 [72 ft 2 ]. The weight of the fabric tested was 1.5 kg [3.3 pounds]. The overall weight of the fabric application plus underlayment was 17.8 kg [39.3 pounds]. TEST SPECIMEN MOUNTING The test specimen was tested in a Type A Mounting in accordance with ASTM 795-05(2012) requirements. Edges of the test specimen were flashed with sheet metal and taped to the Reverberation room floor. Metal tape sealed the top of the flashing to the top of the specimen. Interior joints of the underlayment specimen were not sealed. DESCRIPTION OF TEST The decay rate of sound [which is directly related to sound absorption] is measured upon terminating a steady-state broadband pink noise signal in the 408-m 3 reverberation chamber. Ten (10) ensemble averages containing twenty (20) decays each are measured with both the test specimen inside of and removed from the chamber. These decays were averaged using a linear averaging algorithm and analyzed using ASTM C423-09a required methods to determine sound absorption present in the reverberation chamber. The difference between these two (2) sound absorption tests (with and without the test specimen) at a given frequency is defined as the sound absorption of the specimen. The Sound Absorption Coefficient is the sound absorption per unit area of the test specimen. Sound Absorption Average (SAA) is the average of sound absorption coefficients for twelve (12) one-third-octaves with mid-band frequencies from 200 Hz through 2500 Hz inclusive. Noise Reduction Coefficient (NRC) is a fourfrequency average of the Sound Absorption Coefficient. A rotating microphone boom and a Norsonic 840 Dual Channel Real Time Analyzer, computer controlled using custom software, are used for all measurements. Measurements are made in one-third octaves with mid-band frequencies from 100 Hz to 5000 Hz. The test was conducted in strict accordance with ASTM C423 09a. A reverberation room qualification report for testing to this

-SA6712/-SA6713 Revision 0 Page 3 of 7 standard is available on request. These tests took place at ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY, Cedar Park, TX, on 16 May 2016. SOUND ABSORPTION DATA Measured Sound Absorption [in units of area] and Sound Absorption Coefficients of the test specimens at the preferred one-third octave mid-band frequencies are provided in the tables below and then presented graphically. -SA6712 Carnegie Johns Manville Spin-Glas Board WITHOUT 4666 MINGLE Unbacked, Thickness - 2, Specimen Plan Area 72 ft 2 Type A Mounting One-third Octave Sound Absorption Sound Absorption Repeatability* Reproducibility** Mid-band Frequency (Hz) (m 2 ) Notes Coefficient (+/-) (+/-) 100 1.37 [a] 0.21 0.15 0.27 125 1.67 0.25 0.11 0.22 160 3.07 0.46 0.11 0.23 200 4.00 0.09 0.17 250 4.97 0.74 0.07 0.15 315 6.53 0.98 0.09 0.22 400 7.30 1.09 0.14 0.16 500 7.69 1.15 0.09 0.14 630 7.98 1.19 0.06 0.14 800 7.63 1.14 0.07 0.14 1000 7.44 1.11 0.06 0.12 1250 7.13 1.07 0.05 0.13 1600 6.97 1.04 0.05 0.14 2000 6.75 1.01 0.05 0.13 2500 6.86 1.02 0.06 0.14 3150 6.52 0.97 0.08 0.15 4000 6.58 0.98 0.11 0.16 5000 6.69 0.15 0.21 Sound Absorption Average (SAA) 1.01 0.03 0.08 Noise Reduction Coefficient (NRC) NA NA Notes: [a] due to the very low absorption of the specimen tested, actual absorption values cannot be determined within repeatability values given. The result for this band should be considered inconclusive. *Repeatability values are those values below which the absolute difference between two (2) single test results in the same laboratory that are obtained with the same method on identical test material under the same conditions in a Type A Mounting. Values are based on Round Robin testing between 16 laboratories. Repeatability values represent the probability of 95% that single tests lay within this absolute range. **Reproducibility values are those values below which the absolute difference between two (2) single test results from different laboratories that are obtained with the same method on identical test material in a Type A Mounting. Values are based on Round Robin testing between 16 laboratories. Reproducibility values represent the probability of 95% that single tests between laboratories lay within this absolute range. During the test -SA6712, environmental conditions in the reverberation chamber were 22.6C, 60.7% relative humidity, and 101.1 kpa barometric pressure. Temperature and relative humidity conditions remained within strict limits imposed by the laboratory.

-SA6712/-SA6713 Revision 0 Page 4 of 7 -SA6713 Carnegie Johns Manville Spin-Glas Board WITH 4666 MINGLE Unbacked, Specimen Thickness - 2, Specimen Plan Area 72 ft 2 Type A Mounting One-third Octave Sound Absorption Sound Absorption Repeatability* Reproducibility** Mid-band Frequency (Hz) (m 2 ) Notes Coefficient (+/-) (+/-) 100 1.64 0.25 0.15 0.27 125 1.81 0.27 0.11 0.22 160 3.88 0.58 0.11 0.23 200 4.94 0.74 0.09 0.17 250 6.00 0.90 0.07 0.15 315 7.53 1.13 0.09 0.22 400 8.01 0.14 0.16 500 8.15 1.22 0.09 0.14 630 8.09 1.21 0.06 0.14 800 7.72 1.15 0.07 0.14 1000 7.48 1.12 0.06 0.12 1250 7.09 1.06 0.05 0.13 1600 6.92 1.04 0.05 0.14 2000 6.72 0.05 0.13 2500 6.73 1.01 0.06 0.14 3150 6.52 0.97 0.08 0.15 4000 6.61 0.99 0.11 0.16 5000 6.65 0.99 0.15 0.21 Sound Absorption Average (SAA) 1.07 0.03 0.08 Noise Reduction Coefficient (NRC) 1.05 NA NA Notes: [a] due to the very low absorption of the specimen tested, actual absorption values cannot be determined within repeatability values given. The result for this band should be considered inconclusive. *Repeatability values are those values below which the absolute difference between two (2) single test results in the same laboratory that are obtained with the same method on identical test material under the same conditions in a Type A Mounting. Values are based on Round Robin testing between 16 laboratories. Repeatability values represent the probability of 95% that single tests lay within this absolute range. **Reproducibility values are those values below which the absolute difference between two (2) single test results from different laboratories that are obtained with the same method on identical test material in a Type A Mounting. Values are based on Round Robin testing between 16 laboratories. Reproducibility values represent the probability of 95% that single tests between laboratories lay within this absolute range. During the test -SA6713, environmental conditions in the reverberation chamber were 22.0C, 63.4% relative humidity, and 101.0 kpa barometric pressure. Temperature and relative humidity conditions remained within strict limits imposed by the laboratory. Respectfully Submitted, Michael C. Black Laboratory Technical Director

-SA6712/-SA6713 Revision 0 Page 5 of 7 1.60 Carnegie Johns Manville Spin-Glas Board; 3 pcf; Thickness 2"; 72 ft 2 ; Type A Mounting -SA6712; SAA 1.01 NRC 1.40 Sound Absorption Coefficient 0.80 0.40 0.20 0.00 0.21 100 0.25 125 0.46 160 200 0.74 250 0.98 315 1.09 400 1.15 500 1.19 1.14 1.11 630 800 1000 1250 1.07 1600 1.04 2000 1.01 2500 1.02 3150 0.97 0.98 4000 5000 One-Third Octave Mid-band Frequency (Hz)

-SA6712/-SA6713 Revision 0 Page 6 of 7 1.60 Carnegie Johns Manville Equipment Spin-Glas Board WITH 4666 MINGLE, Unbacked Thickness 2", Plan Area 72 ft 2, Type A Mounting -SA6713; SAA 1.07 NRC 1.05 1.40 Sound Absorption Coefficient 0.80 0.40 0.20 0.00 0.25 100 0.27 125 0.58 160 0.74 200 0.90 250 1.13 315 400 1.22 1.21 1.15 500 1.12 630 800 1000 1250 1.06 1600 1.04 2000 1.01 2500 3150 0.97 4000 0.99 0.99 5000 One-Third Octave Mid-band Frequency (Hz)

-SA6712/-SA6713 Revision 0 Page 7 of 7 1.60 Carnegie Johns Manville Equipment Spin-Glas Board WITH (-SA6713) and WITHOUT (-SA6712) 4666 MINGLE, Unbacked, Thickness 2" - Type A Mounting 1.40 Sound Absorption Coefficient 0.80 0.40 0.20 0.00 100 125 160 200 250 315 One-Third Octave Mid-band Frequency (Hz) 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 With Fabric Application w/o Fabric Application