GPC/SEC An essential tool for polymer analysis

Similar documents
An Introductions to Advanced GPC Solutions

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

Practical Steps in GPC Method Development

GPC/SEC standards. Product guide

GPC/SEC standards. Product guide

Gel Permeation Chromatography Basics and Beyond eseminar March 13, Jean Lane Technical and Applications Support LSCA, Columns and Supplies

Maximizing Performance Through GPC Column Selection

Polymer analysis by GPC-SEC. Technical Note. Introduction

GPC - Gel Permeation Chromatography. aka Size Exclusion Chromatography- SEC

Analysis of Star Polymers Using the Agilent 1260 Infinity Multi-Detector GPC/SEC System

Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How?

AGILENT AQUEOUS AND POLAR GPC/SEC COLUMNS

Characterization of polyphenylene sulphide using the Agilent PL-GPC 220 High Temperature GPC System with triple detection

Aqueous and polar GPC/SEC columns. Product guide

Optimizing GPC Separations

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

GPC/SEC Start-up Kit

Advanced GPC. GPC On Tour, Barcelona, 28 th February The use of Advanced Detectors in GPC

Analysis of polyolefins by GPC/SEC

Application compendium. Authors. Greg Saunders, Ben MacCreath Agilent Technologies, Inc. A guide to multi-detector gel permeation chromatography

GPC / SEC Theory and Understanding

Polymer Analysis by Gel Permeation Chromatography

CALIBRATING GPC COLUMNS

Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. H i

Macromolecular Chemistry

How to use GPC/SEC for compositional analysis

Comprehensive Polymer Analysis Strategies

food testing & agriculture

Organic GPC/SEC columns. Product guide

Tips & Tricks GPC/SEC: Inter-Detector Delay

Latest Developments in GPC Analysis of Adhesive and Sealant Polymers Mark Pothecary PhD Americas Product Manager Malvern Instruments

Tips & Tricks GPC/SEC: From a Chromatogram to the Molar Mass Distribution

Lecture 4 : Gel Permeation or Size Exclusion Chromatography

GFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series. Contents

EcoSEC - semi-micro GPC/SEC system for high throughput polymer analysis

PAPER No. 6: PHYSICAL CHEMISTRY-II (Statistical

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

Low molecular weight resins Analysis of low molecular weight. resins and prepolymers by GPC/SEC. Application compendium. Authors

LC and LC/MS Column Selection Flow Chart

Comparison of Polymer Separation by Size Exclusion Chromatography and Asymmetric Flow Field Flow Fractionation

Optimization of PLA/PLGA molecular weight and structure to suit final application requirements

GPC/SEC. VARIAN, INC. Engineering Polymers ANALYSIS OF ENGINEERING POLYMERS BY GPC/SEC.

GPC/SEC Column Selection & Method Development

Progress toward reliable NC molecular mass distribution by GPC

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Dr. Christoph Johann Wyatt Technology Europe GmbH Copyright Wyatt Technology Europe GmbH All Rights reserved 1

Gel Permeation Chromatography (GPC) or Size Exclusion Chromatography (SEC)

IR-LC Deposition and Detection System. Polymer Deformulation and Additive Analysis by a Single GPC-IR Run

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

GPC/MS. Analysis of PET

Waters GPC User Guide and Tutorial for Using the GPC in the Reynolds Research Group 2 nd Edition: April 2012

Differentiation of polymer branching and composition using the Mark Houwink plot

Gel Permeation Chromatography - GPC

Gel Permeation Chromatography

Gel Permeation Chromatography

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages

GFC Analysis of Water-Soluble Polymers with TSKgel PW-type Columns. Contents

How switching mobile phases can improve your OMNISEC results

Malvern Macromolecular Solutions. Innovative Solutions in Material Characterization

Determination of Polymer Modifier in Asphalt

HPLC Background Chem 250 F 2008 Page 1 of 24

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS

The power of multi-detector SEC in the analysis of antibodies

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Advantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis

Tips & Tricks GPC/SEC: Protein Analysis with Size-Exclusion Chromatography

Chromatography Outline

(3) A UNIVERSAL CALIBRATION FOR GEL PERMEATION CHROMATOGRAPHY. [TIM = 4 R3 gx POLYMER LETTERS VOL. 5, PP (1967)

COURSE MATERIAL: Unit 3 (Part 1) Polymer Science LT8501 (Click the link Detail to download)

Benefit of light scattering technologies (RALS/LALS/MALS) and multidetection characterization in life science research?

[VIM = 4 R3 gx ( 3)

Setting the Standard for GPC. Complete Guide for GPC / SEC / GFC Instrumentation and Detection Technologies. The Right Instrument for Your Application

Physical Polymer Science Lecture notes by Prof. E. M. Woo adapting from: Textbook of Physical Polymer Science (Ed: L. H.

GPC/SEC Analysis of Polymer Degradation

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Size Exclusion Chromatography

Instrumentation & Software

Phenogel. GPC/SEC Columns. Sample Elution. Technical Specifications 10 3 Å 10 6 Å

Chapter content. Reference

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Setting the Standard for Advanced GPC/SEC Systems

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Particle Characterization Laboratories, Inc.

The ph-responsive behaviour of aqueous solutions of poly(acrylic acid) is dependent on molar mass

Final Exam Introduction to Polymers (each part, a,b,c,, is worth 2.2 points)

Sem /2007. Fisika Polimer Ariadne L. Juwono

Relationship of Rheological Behavior and Molecular Architecture for LDPE Designed for Extrusion Coating. Bert Nijhof Technical Paper-7603

A Question of Molecular Weight

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Polymers Reactions and Polymers Production (3 rd cycle)

Polymers in Modified Asphalt Robert Q. Kluttz KRATON Polymers

Chap. 2. Molecular Weight and Polymer Solutions

Speeding up 2D chromatography (HPLCxSEC) at it s limits. ..fast, faster ups broken...

c) fitting of the NMR intensity in dependence of the recycle delays 4

High Performance Liquid Chromatography

Lecture No. (1) Introduction of Polymers

Using High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials with Light Scattering Detection

Advantages of polymerbased. an alternative for ODS

2. Amorphous or Crystalline Structurally, polymers in the solid state may be amorphous or crystalline. When polymers are cooled from the molten state

Transcription:

GPC/SEC An essential tool for polymer analysis Ben MacCreath, PhD Product Manager GPC/SEC Instrumentation 26 th March 2013

Introduction to Polymers Where are they found? Polyolefins Engineering Polymers Resins Biodegradable Polymers Excipients Elastomers Food

Molecular Weight The molecular weight of a polymer is a way of describing how long the polymer chains are Each monomer has a molecular weight (often called the formula weight) Adding the monomers together to make polymers increases the molecular weight The longer the chains, the higher the molecular weight

Effect of Molecular Weight For example, let s look at hydrocarbons Very short chain hydrocarbons are the predominant component of petrol liquid at room temperature Longer chain hydrocarbons are present in various waxes such as candle wax soft, pliable and easy to melt Polyethylene is a very long chain hydrocarbon tough, strong and very resistant to heat and solvents

Polymer Molecular Weight Distributions Samples of synthetic polymers always contain polymer chains with a range of chain lengths One way to describe the length of the polymer chains is in terms of an average molecular weight, i.e the average of all the chain lengths in the sample HOWEVER. Different samples of the same polymer can have the same average chain length but very different distributions of chain lengths depending on the method of production In polymer science it is the molecular weight distribution that is important

Molecular Weight Distribution 6% 12% 70% 10% 2% What is my Molecular Weight? Molecular Weight Averages NMR measures Mn Light scattering measures Mw Osmometry measures Mz GPC measures distribution

Shape of Distributions Even for the same type of polymer, each of these distributions will describe a polymer that behaves differently. The Mn or Mw might be identical for all plots. The red and green plots are for low and high polydispersity materials The blue plot shows a high polydispersity material with a additional high molecular weight component Describing these distributions is not easily, especially if they are complex

Effect of Polydispersity on a Polymer As the broadness of the distribution decreases the strength and toughness of the polymer increases However as the broadness of the distribution decreases the polymer becomes more difficult to process GPC provides key information to predict the processability and material properties of a polymer Strength Toughness Brittleness Melt viscosity Chemical resistance Solubility Increasing Mw + + + + + - Increasing + - - - - - distribution

Variations in Polymers There are a variety of ways to alter properties Chemical Structure of Monomer Unit 3D Structure Different Monomer Units Length of polymer chains Distribution of polymer chain lengths

Introduction to GPC/SEC GPC Separation Mechanism The established technique to measure the distribution of chain lengths is Gel Permeation Chromatography, GPC also known as Size Exclusion Chromatography, SEC Separation based on size of the polymer in solution (hydrodynamic volume) only.

Introduction to GPC/SEC GPC Separation Mechanism

Types of Chromatography Interactive adsorption, partition, ion exchange, etc Non-interactive GPC, SEC, GFC

GPC/SEC compared to HPLC Isocratic elution, often single solvent systems Typically uses organic eluents, not ACN, MeOH, IPA Typically lower sample concentrations (0.1 0.2%) Typically larger injection volumes (20 200 µl) Primary use is to measure molecular weight distribution Resolution provided by non-interactive mechanism Larger columns (300 x 7.5 mm industry standard) Use of multiple columns in series (2 4)

Conventional GPC Generating molecular weights Calibrate the column with a set of polymer standards Plot retention time (RT) versus peak log molecular weight (logm) Calibration is used to generate molecular weights of unknowns BUT Molecular Weights are only equivalent to the Standards used So a Polystyrene calibration will give Polystyrene equivalent molecular weights for all samples analysed.

Molecular Weight Averages by GPC Number average Mn = Ni Mi Ni Mn can be correlative with polymer colligative properties, e.g. freezing point depression Weight average Mw = Ni Mi 2 Ni Mi Mw may be correlated with properties such as melt viscosity Z average Mz = Ni Mi 3 Ni Mi 2 Mz may be correlated with properties such as toughness Polydispersity, d = Mw Mn Polydispersity characterises the shape of the distribution

Introduction to GPC/SEC GPC Separation Mechanism To learn more about Conventional GPC please ask your local Account Manager for the Introduction to GPC Primer

A Typical GPC/SEC System

Columns For polymer applications using organic solvents PLgel series Covers all molecular weight ranges high pore volume high efficiency maximize resolution Unequalled solvent compatibility easy transfer between polar and non polar eluents outstanding physical rigidity provides extended lifetimes that minimize downtime Available in a range of column dimensions, mini-bore to prep

Columns For polymer applications using aqueous solvents PL aquagel-oh series Available with mixed and individual pore sizes, and 5, 8 and 15 μm particle sizes, to cover a very wide range of molecular weights. chemically and physically stable neutral surface high performance analyses neutral, ionic & hydrophobic moieties Available in a range of column dimensions, mini-bore to prep

Polymer Standards Ideal reference materials generate accurate, reliable GPC/SEC column calibrations highest quality polymer standards extremely narrow polydispersity widest molecular weight range commercially available Comprehensive range EasiVial EasiCal Traditional calibration kits Covers all molecular weight ranges Organic & aqueous GPC/SEC applications.

Scope of GPC Application Range GPC can be applied to an extremely broad range of polymers Wide range of solvents employed Organic Polar Aqueous Wide range of operating temperatures Wide range of molecular weights

Scope of GPC Application Range GPC can be applied to an extremely broad range of polymers Wide range of solvents employed Organic Polar Aqueous Wide range of operating temperatures Wide range of molecular weights

Agilent GPC/SEC Software The fastest, easiest way to complete your GPC Workflow System Setup Workbook Setup Collect data Analyse Data Review Data Simplifies and facilitates your GPC/SEC process Everything required for GPC/SEC in a single package

Agilent GPC/SEC Software Single solution for all your GPC/SEC Requirements Control of Agilent GPC/SEC Systems Collection from Agilent GPC/SEC Systems All GPC/SEC Calculations

Agilent GPC/SEC Software Fast and Easy GPC/SEC Baselines / integration regions added with single click Narrow standard Column Calibrations easily created Instant report or overlay data

Testing of material batches Analysis of poly(styrene/butadiene) copolymers Background: A poly(styrene/butadiene) block copolymer mimics the properties of natural rubber. Characteristics provided by: hard polystyrene chains surrounded by a network of rubbery polybutadiene which provides strength and flexibility over a large temperature range. Problem: New batch of material is failing rheology testing Synthetic method to produce the copolymer has not changed End properties of the polymer significantly different to previous batches of the same material. Solution: Investigate molecular weight distribution using GPC

Testing of material batches Analysis of poly(styrene/butadiene) copolymers The GPC chromatogram shows evidence of low molecular weight material within the failed batch. System : 1260 Infinity GPC System Columns : 2 x PLgel 5µm MIXED-D Temperature : 40 C Eluent : THF Standard batch Failed batch Residual homopolymer This was attributed to residual homopolymer from the synthesis which was imparting different characteristics to that of the desired copolymer. With the problem identified the cause was discovered and rectified. RT

Increasing the information from GPC/SEC Most common detectors for GPC/SEC are concentration detectors: RID UV / DAD Evaporative LSD These provide information on the amount of polymer eluting from the column at any given time.

Increasing the information from GPC/SEC There are two common molecular weight sensitive detectors. Viscometer Static Light Scattering Detector These not only respond to the amount of polymer eluting but provide direct information on properties of the polymer relating to molecular weight.

Increasing the information from GPC/SEC GPC/SEC provides critical information for the polymer chemist: Distribution of chain lengths (Relative molecular weights) Further parameters can be determined by employing advanced detectors The molecular weight (accurate or absolute) The polymer s size The polymer s shape Can be used to investigate polymer branching

Polysaccharides Investigation into structure Complex polymers constructed from various sugar units. Wide range of polysaccharides with large structural difference depending on source. Pullulan, produced from starch by the action of a fungus, is composed of maltotriose units and has a linear structure. Dextran, manufactured from sucrose by bacterial action has a highly branched structure. Investigating their structure is of great interest for determining their properties and therefore end use application. Light Scattering & Viscometry are employed to highlight molecular weight and structural differences

Summary GPC/SEC is an indispensable analytical tool for the analysis of Polymers Polymer Additives Applicable in a wide range of solvents allowing almost all commercial polymers to be analysed The critical and often unique information attained is the population of polymer chain lengths in any given sample The GPC/SEC experiment can be expanded to further investigate polymer properties more on this later

Thanks for Listening Any Questions

GPC/SEC Resources Brochure Application Compendia Primers Product guides Selection guide Agilent GPC/SEC solutions - comprehensively better polymer analysis 5990-8844EN Engineering polymers 5990-6970EN Polyolefin analysis 5990-6971EN Analysis of elastomers by GPC/SEC 5990-6866EN Biodegradable polymers 5990-6920EN Low molecular weight resins and prepolymers 5990-6845EN Excipient analysis 5990-7771EN Analysis of food additives by GPC/SEC 5990-8634EN Introduction to GPC/SEC 5990-6969EN A guide to multi-detector GPC 5990-7196EN 1260 Infinity GPC/SEC System 5990-9920EN 1260 Infinity Multi-GPC/SEC System 5990-9921EN Agilent PL-GPC 50 5990-9937EN Agilent PL-GPC 220 5990-9926EN Agilent GPC/SEC Software 5991-0478EN Aqueous and polar GPC/SEC columns 5990-7995EN Organic GPC/SEC columns 5990-7994EN GPC/SEC standards 5990-7996EN Quick guide for selecting columns and standards for GPC/SEC 5990-6868EN Download at http://www.agilent.com/chem/gpc-solutions