Targeted protein quantification

Similar documents
HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Peptide Targeted Quantification By High Resolution Mass Spectrometry A Paradigm Shift? Zhiqi Hao Thermo Fisher Scientific San Jose, CA

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

High-Field Orbitrap Creating new possibilities

Introduction to Fourier Transform Infrared Spectroscopy

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

for XPS surface analysis

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

HR/AM Targeted Peptide Quantitation on a Q Exactive MS: A Unique Combination of High Selectivity, Sensitivity and Throughput

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

MetWorks Metabolite Identification Software

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

of mass spectrometry

Q Exactive TM : A True Qual-Quan HR/AM Mass Spectrometer for Routine Proteomics Applications. Yi Zhang, Ph.D. ThermoFisher Scientific

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Relative quantification using TMT11plex on a modified Q Exactive HF mass spectrometer

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Protein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University

A Platform to Identify Endogenous Metabolites Using a Novel High Performance Orbitrap MS and the mzcloud Library

Introduction to Fourier Transform Infrared Spectroscopy

Increasing the Multiplexing of Protein Quantitation from 6- to 10-Plex with Reporter Ion Isotopologues

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Key Words Q Exactive Focus, Orbitrap, veterinary drugs, small molecule HRAM quantitation, small molecule HRAM screening, UHPLC, vdia

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry

Direct Analysis using Paper-Spray Mass Spectrometry: Method Development for the Rapid Screening of Drugs of Abuse for Forensic Toxicology

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Charles Yang, Dipankar Ghosh, Jonathan Beck Thermo Fisher Scientific, San Jose, CA, USA

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Guide to Peptide Quantitation. Agilent clinical research

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Protein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University

Multi-residue analysis of pesticides by GC-HRMS

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Quantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Fast, Effective XPS Point Analysis of Metal Components

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Automated and accurate component detection using reference mass spectra

Improving Intact Antibody Characterization by Orbitrap Mass Spectrometry

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Chemical Labeling Strategy for Generation of Internal Standards for Targeted Quantitative Proteomics

Designed for Accuracy. Innovation with Integrity. High resolution quantitative proteomics LC-MS

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

High-Resolution Accurate-Mass (HRAM) Phthalate Screening using Direct Analysis in Real Time (DART) Ambient Ionization

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

Quantitation and Characterization of Copper Plating Bath Additives by Liquid Chromatography with Charged Aerosol Detection

HILIC Method Development in a Few Simple Steps

Detection of Mycotoxins in Corn Meal Extract Using Automated Online Sample Preparation with Liquid Chromatography-Tandem Mass Spectrometry

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

Screening Method for 30 Pesticides in Green Tea Extract Using Automated Online Sample Preparation with LC-MS/MS

An Evaluation of Various High-Resolution, Accurate-Mass Scan Modes for In Vitro Drug Discovery Screening

Powerful Scan Modes of QTRAP System Technology

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

A Quadrupole-Orbitrap Hybrid Mass Spectrometer Offers Highest Benchtop Performance for In-Depth Analysis of Complex Proteomes

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

NIH Public Access Author Manuscript Nat Methods. Author manuscript; available in PMC 2014 February 01.

Semi-Targeted Screening of Pharmaceutically- Related Contaminants in the Thames Tideway using LC-HRMS

Key Words Nanoparticles, spicp-ms, ICP-MS, Qtegra ISDS Software, AF4-ICP-MS

Impurity Profiling of Pharmaceutical Starting Materials Using Gas Chromatography Coupled with High- Resolution Accurate Mass Spectrometry

IN QUALITATIVE ANALYSIS,

6 x 5 Ways to Ensure Your LC-MS/MS is Healthy

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

Targeted Proteomics Environment

The key to your laboratory s success

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

WADA Technical Document TD2003IDCR

Thermo Finnigan LTQ. Specifications

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

DIA-Umpire: comprehensive computational framework for data independent acquisition proteomics

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

TOMAHAQ Method Construction

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

Monitoring Protein PEGylation with Ion Exchange Chromatography

Finnigan LCQ Advantage MAX

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Transcription:

Targeted Quantitative Proteomics Targeted protein quantification with high-resolution, accurate-mass MS Highly selective Very sensitive Complex samples

HR/AM A more complete quantitative proteomics picture Targeted protein quantification is frequently applied to large sample sets to verify large numbers of targets such as putative biomarkers identified from earlier discovery experiments. It is also used to analyze protein protein interaction networks in biological systems as part of signaling pathway studies. Selected-reaction monitoring (SRM) on triple quadrupole mass spectrometers has traditionally been considered the gold standard for targeted protein quantification. It can, however, present challenges when the goal is to quantify large numbers of targeted proteins in complex biological matricies. First, the lower mass resolution of quadrupoles limits the ability to distinguish targets from near-isobaric background ions. This can decrease the detection limit. Second, it is slow and costly to develop an SRM assay, which may require hundreds to thousands of transitions for quantification of large numbers of peptides. Finally, some peptides such as glycopeptides, peptides with higher charge states, or peptides with higher mass-to-charge ratios, are difficult to analyze with SRM. Their poor fragmentation efficiency results in relatively few transitions that can be used for quantification. Many of the limitations associated with traditional SRM assays for the verification stage of the proteomics workflow can be addressed using a high-resolution, accurate-mass (HR/AM) mass spectrometer. Thermo Scientific Orbitrap -based mass spectrometers provide high resolving power and mass accuracy in both MS and MS 2 to speed research. 1 8 6 4 2 SRM 24 25 26 27 28 29? RT: 26.62? RT: 26.91 24 25 26 27 28 29 Quantification of the heavy peptide GISNEGQNASIK spiked in an E. coli digest mixture at a 1 amol concentration level. 1 8 6 4 2 HR/AM RT: 26.61 Benefits of an HR/AM approach: High selectivity resolves peptides differing in mass by as little as tens of parts per million (ppm) High sensitivity detects low-abundance targets in complex samples High accuracy quantifies targets accurately over a broad dynamic range High confidence confirms sequences with HR/AM MS and MS/MS spectra High productivity eliminates time-consuming selection of transitions and optimization of parameters High flexibility targets any detectable peptide of interest The high resolving power of the Orbitrap mass analyzer enables selective and sensitive HR/AM quantitative assays for precise targeted protein quantification in complex matrices. 2 3

Q Exactive Mass Spectrometer The ideal choice for HR/AM protein quantification The Q Exactive MS enables a wide range of targeted quantification approaches with its unique design and features. While all Orbitrap-based instruments are capable of excellent targeted protein quantification, the Thermo Scientific Q Exactive hybrid quadrupole-orbitrap mass spectrometer (MS) is the most suitable Orbitrap platform for this application 1,2. With its unique spectrum, multiplexing capabilities and faster scan speed, the Q Exactive MS provides enough scan points for precise quantification even for narrow ultra-high-performance liquid chromatography (UHPLC) peaks. With resolving power up to 14,, the Q Exactive MS consistently provides confident targeted peptide sequence confirmation with HR/AM MS and MS/MS spectra. The Q Exactive MS also provides SRM-comparable sensitivity for quantifying low-abundance proteins in complex biological matrices. Key Features: 14k max resolution <1 ppm mass accuracy 12 Hz HCD at 17.5k resolution Parallel filling and detection Spectrum multiplexing up to 1 events Three targeted quantification methodologies using HR/AM 4 5

PRM SIM for high selectivity for flexibility How it works Benefits of PRM Parallel-reaction monitoring (PRM) provides high selectivity, high sensitivity, and high-throughput quantification with confident targeted peptide confirmation. It is most suitable for quantifying tens to hundreds of targeted proteins in complex matrices. Selected-ion monitoring (SIM) provides the simplest method set up and the most selective and sensitive quantification. It is most suitable for quantifying tens of proteins in samples of medium complexity. SIM also provides higher sensitivity for quantification of labile peptides which do not fragment efficiently. Eliminates most interferences, providing more accuracy and attomole-level limits of detection and quantification Enables the confident confirmation of the peptide identity with spectral library matching Reduces assay development time since no target transitions need to be preselected PRM methodology uses the quadrupole of the Q Exactive MS to isolate a target precursor ion, fragments the targeted precursor ion in the collision cell, and then detects the resulting product ions in the Orbitrap mass analyzer. Quantification is carried out after data acquisition by extracting one or more fragment ions with 5 1 ppm mass windows. PRM offers several advantages compared to traditional SRM quantification. Benefits of SIM Ensures UHPLC-compatible data acquisition speeds with spectrum multiplexing and advanced signal processing Increases sensitivity 5- to 5-fold compared to full-scan MS Enriches targeted precursor ions in the narrow mass range Provides higher selectivity and sensitivity with maximum resolving power of 14K Improves throughput using multiplexed SIM capability in combination with scheduled time windows The SIM methodology uses the quadrupole of the Q Exactive MS to isolate a target ion. Only the selected target ion is transferred to the Orbitrap mass analyzer for detection. There is no fragmentation. Confirmation of the targeted peptide is accomplished using accurate-mass measurements in combination with elution-time information. 1 1 msxsim of the three targets t hat were eluted at the same time 891.9886 z=2 1 9 8 Isolation with the Quadrupole Fragmentation with the HCD Cell Detection with the Orbitrap Analyzer Identification using MS/MS Spectrum Quantification of XIC 17.5445 111.5614 z=2 z=2 7 RT: 4.98 111.593 1 PRM with the Q Exactive mass spectrometer RT RT: 41.25 17.429 How it works RT: 41.56 891.9888 3 32 34 36 38 4 42 44 46 48 5 52 54 56 Multiplexed SIM (msxsim) can significantly increase throughput 6 5 4 3 2 6 y1 y8 4 y5 2 b3 y9 y3 y4 6 Quan XICs of three y ions with ± 5 ppm mass range 4 6 2 4 6 8 1 Increased sensitivity of HR/AM PRM eliminates interferences from background. 7 8 9 1 11 12 2 26 RT 27 28 4E+9 3E+9 1 Log 2 y6 6 Heavy peptide YF*QGYAR spiked in 25ng CSF digest 1 amol - 1 fmol 4 Peak Area 8 8 1 Peak area Qual 1 y7 26.61 Peak area 1 b2 4 8 Sample amount (amole) PRM provides precise quantification over a wide linear dynamic range. 12 Sensitivity and linear dynamic range using msxsim S/N: >4 SSAAPPPPPR* 1amole 1fmole 1fmole Sample amount (Log1) 2E+9 GISNEGQNASIK* 1E+9 DIPVPKPK* E+ 5 Sample amount (fmole) 1 7

DIA for high throughput How it works Data-independent acquisition (DIA) provides a highthroughput method for comprehensive quantification with qualitative confirmation. It is most suitable for quantifying large numbers of mid- to high-abundance proteins in samples of simple to medium complexity. In DIA experiments, a precursor mass range is selected, usually one that covers the masses of most enzymatic peptides. That range is then divided DIA into a series of relatively wide isolation windows: for example, 25 each. MS/MS data is acquired from all detected precursor ions in the first isolation window. That is repeated for each consecutive, adjacent isolation window until the entire precursor mass range is covered. 3 MS/MS spectral libraries are used to identify peptides of interest from the acquired data. Benefits of DIA Enables large-scale targeted proteomics studies with qualitative confirmation Allows simple and universal acquisition method development without detailed sample knowledge prior to data acquisition Increases coverage and reproducibility with a complete record of quantitative data Facilitates retrospective mining of additional analytes DIA significantly increases coverage and reproducibility by acquiring MS/MS data from all detected precursor ions. This also makes possible retrospective data analysis. Because no prior knowledge of expected precursors is required, DIA method development is very simple. Principles of DIA By increasing or decreasing the mass range, the user can balance mass range coverage with mass resolution. Due to the wide isolation windows used in DIA, MS/MS spectra of interfering background ions may be acquired along with the spectra from peptides of interest. Thus, the dynamic range, accuracy, and precision of targeted quantification by DIA may be limited in complex samples. DIA experiments do not provide the same sensitivities and low quantitative limits as PRM and SIM. The unique ability of the Q Exactive MS to reconstruct a precursor ion during DIA analysis is crucial. msxdia Multiplexed DIA (msxdia) is a variation of the DIA technique. It can reduce interference from background ions and improve selectivity while retaining the comprehensive coverage of DIA. In msxdia, the mass range is divided into much narrower precursor isolation windows, each typically about 4 wide. In each scan cycle, five of these windows are chosen at random and MS/MS data is acquired from the precursor ions in those windows. This is repeated until the list of isolation windows is empty. The MS/MS spectra are assembled and demultiplexed using a non-negative least squares technique that helps remove interferences from the spectrum and thus provides higher selectivity than standard DIA. 4 Skyline software 5 is required to manage the selection of isolation windows and process the data. MS MS 1 57.29 Multiplexed DIA process 1 8 6 4 2 175.12 577.38 1 MS/MS of 5 525 77.49 656.44 41.29 426.2 57.25 3.6 sec 32 consecutive MS/MS events cover 4 12 precursor range 57.25 57.25 57.25 57.26 57.26 57.27 57.27 57.27 57.28 57.26 57.25 57.26 57.27 57.28 1 299.6 MS/MS of 1 173.13 525 55 8 8 215.14 6 6 4 173.13 525.29 415.4 2 239.9 359.3 618.32 717.39 116.54 57.28 4 2 57.28 57.28 359.15 MS/MS of 55 575 651.31 746.4 1125.55 557.38 847.46 Scan 1 Scan 2 Scan 3... Scan N 4 divided by 4 per window = 1 windows 5 random windows per scan 5 9 8 2 4 6 8 1 2 4 6 8 1 2 4 6 8 1 9

Accelerating targeted quantification with software As a leader in serving science, we offer a full range of Thermo Scientific products from QC peptide mixtures and sample enrichment kits to UHPLC systems and nanoelectrospray sources to support the entire targeted protein quantification mass spectrometry workflow. Thermo Scientific Pinpoint software facilitates targeted protein quantification by providing rapid method development and automatic qualitative and quantitative data processing. Related products Leverages discovery data from local and global repositories Builds MS/MS spectral libraries using previously acquired discovery data Develops a targeted list of proteins of interest The Thermo Scientific Dionex UltiMate 3 RSLCnano system Analyzes qualitative and quantitative results simultaneously with HR/AM PRM, SIM, or DIA data delivers continuous flow from 2 nl/min to 5 µl/min at up to 8 bar. The system is designed with application flexibility in mind. The RSLCnano system can be operated at nano, capillary, and micro flow rates, configured for a large range of 1D and 2D workflows. Pinpoint software displays, in a single view, the results of a DIA experiment 1 2 3 4 5 Targeted list of proteins The Thermo Scientific EASY-nLC 1 system Quantification results for highlighted peptide is designed for maximum ease-of-use and provides a fully integrated, split-free, nano-lc system working at pressures up to 1 bar. The flow range is 5 nl/min to 1 µl/min for peptide separation. Integrated peak area for highlighted peptide in each sample Spectral library match results for highlighted peptide in each sample Calibration curve for highlighted peptide 1 The Thermo Scientific EASY-Spray source 2 provides an integrated, temperature-controlled, column-emitter design. It uses a single Thermo Scientific Dionex nanoviper connection between the LC and the EASY-spray source to reduce the opportunity for error. By offering plug-and-spray simplicity with state-of-the-art performance, the EASY-Spray source ensures excellent repeatability and reproducibility. The Thermo Scientific Pierce Peptide Retention Time Calibration Mixture enables reversed-phase LC and LC-MS users to optimize and confirm correct operation of their equipment. The Thermo Scientific HeavyPeptide Custom Synthesis Standards 3 5 are custom-made, isotopically labeled, AQUA-grade peptides for the relative and absolute quantification of proteins of interest. The Thermo Scientific HeavyPeptide IGNIS Prime Quantitation Kit enables absolute quantitation of target peptides in less time by using the properties of isotopologues to generate the calibration curve and perform quantification in a single LC-MS run. 1 4 11

References 1. Peterson, A.C.; Russell, J.D.; Bailey, D.J.; Westphall, M.S; Coon, J.J., Parallel Reaction Monitoring for High Resolution and High Mass Accuracy Quantitative, Targeted Proteomics. Mol Cell Proteomics, 212, as Manuscript O112.2131. 2. Gallien, S,; Duriez, E.; Crone, C.; Kellmann, M.; Moehring, T.; Domon, B., Targeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer. Mol Cell Proteomics, 212, as Manuscript O112.1982. 3. Gillet, L.C.; Navarro, P.; Tate, S.; Roest, H.; Selevsek, N.; Reiter, L.; Bonner, R.; Aebersold, R., Targeted data extraction of the MS/MS spectra generated by data independent acquisition: a new concept for consistent and accurate proteome analysis. Mol Cell Proteomics, 212, as Manuscript O111.16717. 4. Egertson,J.D.; Kuehn, A.; Merrihew, G.; Bateman, N.; MacLean, B.; Ting, Y. S.; Canterbury, J. D.; Kellmann, M.; Zabrouskov, V.; Wu, C.; MacCoss, M. J., Multiplexed Data Independent Acquisition for Comparative Proteomics. ASMS poster, 212. 5. MacLean, B.; Tomazela, D.M.; Matthew, N.; Chambers, M.; Finney, G.L.; Frewen, B.; Kern, R.; Tabb, D.L.; Liebler, D.C.; MacCoss, M.J, Skyline: an open source document editor for creating and analyzing targeted proteomics experiments. OXFORD JOUNALS, Bioinformatics, Volume 26, issue 7, p 966-968. www.thermoscientific.com 213 Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Africa-Other +27 11 57 184 Australia +61 3 9757 4486 Austria +43 1 333 5 34 Belgium +32 53 73 42 41 Canada +1 8 53 8447 China +86 1 8419 3588 Denmark +45 7 23 62 6 Europe-Other +43 1 333 5 34 Finland/Norway/Sweden +46 8 556 468 France +33 1 6 92 48 Germany +49 613 48 114 India +91 22 6742 9434 Italy +39 2 95 591 Japan +81 45 453 91 Latin America +1 561 688 87 Middle East +43 1 333 5 34 Netherlands +31 76 579 55 55 New Zealand +64 9 98 67 Russia/CIS +43 1 333 5 34 South Africa +27 11 57 184 Spain +34 914 845 965 Switzerland +41 61 716 77 UK +44 1442 233555 USA +1 8 532 4752 BR6374_E 4/13S