ASTM C STEADY-STATE HEAT FLUX MEASUREMENTS AND THERMAL TRANSMISSION PROPERTIES BY MEANS OF THE HEAT FLOW METER APPARATUS

Similar documents
REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA. EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT

Sound Absorption Test Intertek. kraft paper softwall + softblock modular system. m o l o d e s i g n, l t d

TEST REPORT. Test Method : See the attached sheets.

Standard Guide for Determination of the Thermal Resistance of Low-Density Blanket-Type Mineral Fiber Insulation 1

TEST REPORT. Page 1 of 11

Reflectec Thermal Fabric & Reflectec Fiberboard

MOLEKULE INC. TEST REPORT

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NORTH EAST WINDOWS USA, INC.

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Test Report For: FunderMax GmbH. MAX Resistance 2. SEFA , 2.1 Chemical/Stain Resistances

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

Test Results: Results of the test period on 06/19/16 using the Equivalent CTS Method: Thermal transmittance at test conditions (U s ):

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC.

REPORT NUMBER: GZU-001 ORIGINAL ISSUE DATE:

PERFORMANCE TEST REPORT. Rendered to: WORLDWIDE DOOR COMPONENTS, INC. PRODUCTS: PVC and Composite Door Jamb Material

Intertek Environmental VOC Emissions

Standard Test Method for Determination of the Thermal Conductivity of Anode Carbons by the Guarded Heat Flow Meter Technique 1

AGING OF THERMAL INSULATION MATERIALS BY ACCELERATED LABORATORY TEST METODS

Electrical Parameter. Measurement and Test Report for. MaxGreen LED Ltd.

ASTM C THERMAL PERFORMANCE TEST REPORT. Rendered to: UNIVERSAL PULTRUSIONS, LLC. PRODUCT: Fiberglass Door Slab

Standard Test Method for Thermal Conductivity of Refractories 1

Vincent Barraud SOPREMA BASICS OF THERMAL INSULATION

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NU VISTA WD, INC. SERIES/MODEL: Malibu 250 T TYPE: Fixed

The Characterization of Thermal Interface Materials using Thermal Conductivity for Within Sample and Batch to Batch Variation Analysis

Order No. G Date: September 8, 2010 REPORT NO CRT-001 TEST OF SMF/PAPI SYSTEM RENDERED TO

HFM 100 Series. Thermal Conductivity Meter for measurement of insulation and construction materials.

AIR-INS inc. 1320, boul. Lionel-Boulet, Varennes (Quebec) J3X 1P7 Tél. : (450) Fax : (450)

PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. PRODUCT: SUN TUNNEL Domes TYPES: Acrylic and Polycarbonate

Assessing The Thermal Performance of Building Enclosure Materials Using A Medium-Size Hot Box Chamber Summer Meeting Torkan Fazli

Calibration of Temperature Block Calibrators

Report No: NCTL NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 12/14/15

Use of Phase-Change Materials to Enhance the Thermal Performance of Building Insulations

CALIBRATION CERTIFICATE # 503

REPORT NUMBER: GZU -001 ORIGINAL ISSUE DATE:

Report No: NCTL S NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 07/14/15. Test Specimen

Standard Test Methods for Glass-Bonded Mica Used as Electrical Insulation 1

EA-10/13. EA Guidelines on the Calibration of Temperature Block Calibrators. Publication Reference PURPOSE

FUNDERMAX GMBH TEST REPORT

TEST METHOD FOR DETERMINING BREAKAWAY FORCE OF A MAGNET

Standard Test Method for Steady-State Heat Transfer Properties of Horizontal Pipe Insulation 1

THERMAL PERFORMANCE TEST REPORT

Standard Practice for Heat Aging of Plastics Without Load 1

Morehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web: sales:

TEST REPORT IEC Photobiological safety of lamps and lamp systems

Dubai Central Laboratory Engineering Materials Laboratory Section - Structural Unit TEST REPORT T DENSITY OF RIGID CELLULAR PLASTICS

NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 03/31/06

CALIBRATION REPORT FOR THERMOHYDROMETER

LaserComp, Inc., DESCRIPTION OF THE INSTRUMENT

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL

INFLUENCE OF SURFACE EMISSIVITY AND OF LOW EMISSIVITY SHIELDS ON THE THERMAL PROPERTIES OF LOW DENSITY INSULATING MATERIALS

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

Experimental Results for Thermal Conductivity of Paraffin Waxes

Chapter 17 Temperature and heat

Standard Practice for Calculating Thermal Transmission Properties Under Steady- State Conditions 1

Good practice guide containing experimental results and recommendations for the selection, preparation and calibration of the temperature sensors

CERTIFICATE OF CALIBRATION

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL

NFRC SOLAR HEAT GAIN COEFFICIENT TEST REPORT. Rendered to: CLEAR FOCUS IMAGING

ANSI/AHRI Standard (Formerly ARI Standard ) 2006 Standard for Performance Rating of Desuperheater/Water Heaters

WACEL AGGREGATE LABORATORY TESTING TECHNICIAN

CERTIFICATE OF CALIBRATION

Technical Procedure for Measurement Assurance

Uncertainty Propagation for Force Calibration Systems

NFRC THERMAL TEST SUMMARY REPORT January 27, 1999 Test Specimen

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL

INTERNATIONAL STANDARD

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL

- Laboratory Report - Full Particle Identification Project: CI0333/HP107

MEASUREMENT OF THE THERMAL DIFFUSIVITY OF BUILDING MATERIALS

Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate 1

Infrared Thermometer Calibration A Complete Guide

A L I O N Technical Center. Test Report

CORM Exploring optical radiation pressure as a convenient measure of high-power. laser emission

CERTIFICATE OF CALIBRATION

Thermal Properties Calculations Using Finite-Difference Method Akhan Tleoubaev and Andrzej Brzezinski

CERTIFICATE OF CALIBRATION

TEST METHOD FOR THERMAL TRANSMITTANCE AND AIR INFILTRATION OF GARAGE DOORS

Data sheet FIXED THICK FILM CHIP RESISTORS; RECTANGULAR TYPE ANDULTRAHIGH VOLTAGE. AEC-Q200 qualified. RoHS COMPLIANCE ITEM Halogen and Antimony Free

Data sheet FIXED THICK FILM CHIP RESISTORS; RECTANGULAR TYPE RMC1/32,1/20,1/16S,1/16,1/10,1/8,1/4,1/2,1. AEC-Q200 qualified (Without RMC1/32)

2.1. Accuracy, n- how close the indication of the thermometer is to the true value.

HR-Z SERIES Mild Radiation Resistance LVDT

IN-PLANE THERMAL CONDUCTIVITY OF FLAT PLATES UTILIZING THE FOURIER HEAT CONDUCTION LAW

Army Air Forces Specification 7 December 1945 EQUIPMENT: GENERAL SPECIFICATION FOR ENVIRONMENTAL TEST OF

fdfdfdfdfd Effects of Interface Resistance on Measurements of Thermal Conductivity of Composites and Polymers

Certificate of Analysis

Data sheet FIXED CHIP RESISTORS; RECTANGULAR TYPE & WIDE TERMINATION. AEC-Q200 qualified. RoHS COMPLIANCE ITEM Halogen and Antimony Free

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement

Standard Test Method for Measuring the Steady-State Thermal Transmittance of Fenestration Systems Using Hot Box Methods 1

Solar Flat Plate Thermal Collector

THERMAL PROPERTY MEASUREMENT TECHNIQUES. AND SOME RESULTS FOR CdTe. H. F. Poppendiek D. J. Connelly R. K. Livett

Heat and Mass Transfer Prof. S.P. Sukhatme Department of Mechanical Engineering Indian Institute of Technology, Bombay

Experiment 1. Measurement of Thermal Conductivity of a Metal (Brass) Bar

Certificate of Accreditation

THERMAL CONDUCTIVITY OF BUILDING MATERIALS: AN OVERVIEW OF ITS DETERMINATION

Fundamentals of Transport Processes Prof. Kumaran Indian Institute of Science, Bangalore Chemical Engineering

Standard Terminology Relating to Thermal Insulating Materials 1

HYGROTHERMAL CHARACTERISTICS OF PUMICE AGGREGATE CONCRETE USED FOR MASONRY WALL BLOCKS

We are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1%

Transcription:

Page 1 of 10 ASTM C 518 04 STEADY-STATE HEAT FLUX MEASUREMENTS AND THERMAL TRANSMISSION PROPERTIES BY MEANS OF THE HEAT FLO METER APPARATUS Rockwool Premium Plus Insulation Project No. 3194876SAT-001A December 11, 2009 Prepared for: Amerrock Products, LP PO Box C Nolanville, TX 76559 Intertek Testing Services NA, Inc. 16015 Shady Falls Road Elmendorf, Texas 78112 Telephone: 210-635-8100 Fax: 1-210-635-8101 e-mail: www.intertek-etlsemko.com

Amerrock Products, LP Page 2 of 10 ABSTRACT Specimens submitted for testing by Amerrock Products, LP identified as Rockwool Premium Plus Insulation were tested in triplicate in accordance with ASTM C 518 04. TEST NO. HOT & COLD SEPARATION (mm) HEAT FLO HOT ( m 2 ) TEMPERA- TURE ( C) COLD TEMPERA- TURE ( C) THERMAL TRANSMIS- SION ( m K ) COLD /HOT DELTA T ( F) 1 101.60 11.16 40.0 10.0 0.0378 54.0 2 101.60 10.36 39.4 10.0 0.0357 53.0 3 101.60 9.18 40.0 10.0 0.0311 54.0 Average 101.60 10.23 39.8 10.0 0.0349 53.7 NOTE: See Conclusions Section for expression of thermal transmission and thermal conductivity in English units and for various material thickness. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. This report contains a total of ten pages. Darrell R. Gonzales Technician December 11, 2009 Reviewed and approved: Servando Romo Project Manager December 11, 2009

Amerrock Products, LP Page 3 of 10 TABLE OF CONTENTS SECTION PAGE I. Introduction 4 II. Procedure 6 III. Test Results 7 IV. Conclusions 8 V. Accuracy of the Test Method 10

Amerrock Products, LP Page 4 of 10 I. INTRODUCTION 1 This test method covers the measurement of steady state thermal transmission through flat slab specimens using a heat flow meter apparatus. This is a comparative (or secondary) method of measurement since specimens of known thermal transmission properties must be used to calibrate the apparatus. Properties of the calibration specimens must be traceable to an absolute measurement method, and should be obtained from or traceable to a recognized national standards laboratory. The test method is applicable to the measurement of thermal transmission through a wide range of specimen properties and environmental conditions. The method has been used at ambient conditions of 10 to 40 C with thickness up to approximately 250 mm, and with plate temperatures from 195 C to 540 C at 25 mm thickness. This test method may be used to characterize material properties which may or may not be representative of actual conditions of use. Other test methods such as Test Methods C 236 or C 976 should be used if needed. To meet the requirements of this test method, the thermal resistance of the sample must be greater than 0.10 K m 2 / in all directions. It is not practical in a test method of this type to try to establish details of construction and procedures to cover all contingencies that might offer difficulties to a person without pertinent technical knowledge. Thus users of this test method shall have sufficient knowledge to satisfactorily fulfill their needs. For example, knowledge of heat transfer principles, low level electrical measurements, and general test procedures is required." 1 ASTM C518-04 Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus, Annual Book of ASTM Standards, 04.06, American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA.

Amerrock Products, LP Page 5 of 10 Summary of Test Method The heat flow meter apparatus establishes steady state unidirectional heat flux through a test specimen between two parallel plates at constant but different temperatures. By appropriate calibration of the heat flux transducer(s) with calibration standards and by measurement of the plate temperatures and plate separation, Fourier s law of heat conduction is used to calculate thermal conductivity, thermal resistance, or resistivity. The accurate use of the test method is limited by the capability of the apparatus to reproduce unidirectional constant heat flux density in the specimens, and by the precision in the measurement of temperature, thickness, EMF produced by the heat flux transducer, etc. The apparatus shall not be used at temperatures, thickness or resistances, other than those within the range of the calibration, unless it can be shown that there is no difference in accuracy. The apparatus must be capable of maintaining at least a 10 C temperature difference across the specimen for the duration of the test, unless a smaller LT is a requirement of a particular test. The specimens under test may also limit the use of the test method and these limitations are outlined in Practice C1045. This evaluation was accomplished using a Model Rapid-k Heat Flow Meter Thermal Conductivity Instrument, manufactured by Dynatech R/D Company. The Rapid-k determines thermal conductivity in accordance with ASTM C 518... Heat flow through a solid, results from having a temperature gradient in the material. Thermal conductivity is a material property, which determines how much heat flows through a given thickness of the material when there is a temperature difference. The Fourier linear heat flow equation defines thermal conductivity under steady state conditions as: where: l = ø DX DT l = thermal conductivity, m K ø = heat flux, m 2 DT = temperature difference across distance LX, K DX = distance between hot and cold plates, m

Amerrock Products, LP Page 6 of 10 II. PROCEDURE In practice, thermal conductivity determinations are made on thermal insulation by placing a sample of the material between two surfaces maintained at a known temperature. Because of the temperature difference, heat flows through the sample from the hot side to the cold side. The quantity of heat flowing through the sample is measured by a heat flow transducer, which is a device having an output proportional to the heat flow passing through it. This transducer is placed between the sample and the cold plate. Because some heat flows through the edges of the sample to or from the surroundings, the heat flow measurement is made in the central 4 inch square area of a 12 inch square sample only. The heat flow through the central area of the sample is one-directional between the hot and the cold face, as the effect of heat flow across the edges is absorbed entirely by the sample material that surrounds the central heat measuring area. The Rapid-k test apparatus is used for determining the thermal conductivity of fibrous, cellular, particulate, and other thermal insulation. Although the instrument can be used to test almost any solid insulating materials that can be produced in 12-inch square sections, its primary applications are the testing of coarse grain and non-homogeneous materials, where the large sample is necessary in order to obtain test results that are representative of the sample material in bulk form. Examples are foam plastics, fibrous insulation, sand, asbestos, wood, concrete, and other materials. Description of Test Specimens The test specimens were submitted by Amerrock Products, LP and identified as follows: Sample ID: Rockwool Premium Plus Insulation Description: 4-inch Mineral ool insulation Date Received: The samples were received in good condition on 11/13/09 and on 12/04/09. Date Tested: 11/13/09, 11/16/09, 12/10/09 This Test itnessed by: Not witnessed Environmental Conditions: 72 F and 53% r.h.-11/13/09, 73 F and 51% r.h.-11/16/09, and, 69 F and 50% r.h.-12/10/09.

Amerrock Products, LP Page 7 of 10 Three specimens were tested so that an average result could be reported. The specimens had dimensions of 12 inches by 12 inches by an average thickness of 4.00 inches and consisted of mineral wool insulation. All the specimens were conditioned under standard laboratory conditions (23 ± 3 C and 50% relative humidity) until they were at constant moisture content, as determined by their attaining constant weight. Prior to each series of three tests, the Rapid-k was calibrated using a sample whose thermal conductivity is known and traceable to national standards. To perform the test, the specimen was placed in the Rapid-k instrument, the bottom (cold) plate is brought upwards creating contact of both plates with the test specimen, and the instrument was sealed. The hot and cold plates were then allowed to equilibrate to the required temperatures and their exact temperatures were read from the instrument. In addition, a millivolt signal, which is proportional to the heat flow through the transducer, was recorded. III. TEST RESULTS The test results from this evaluation are given in the following table, which contains equilibrium data from each test. TEST NO. HOT & COLD SEPARATION (mm) HEAT FLO HOT ( m 2 ) TEMPERA- TURE ( C) COLD TEMPERA- TURE ( C) THERMAL TRANSMIS- SION ( m K ) COLD /HOT DELTA T ( F) 1 101.60 11.16 40.0 10.0 0.0378 54.0 2 101.60 10.36 39.4 10.0 0.0357 53.0 3 101.60 9.18 40.0 10.0 0.0311 54.0 Average 101.60 10.23 39.8 10.0 0.0349 53.7 TEST NO. DENSITY OF SPECIMEN (kg/m 3 ) DATE TESTED 1 78.81 11/13/09 2 85.54 11/16/09 3 119.66 12/10/09

Amerrock Products, LP Page 8 of 10 IV. CONCLUSIONS The Thermal Conductivity, l, and Thermal Resistance, R, of the specimens tested were: THERMAL CONDUCTIVITY SAMPLE NO. Btu-in / F-ft 2 -h) /(m*k) 1 0.262 0.0378 2 0.248 0.0357 3 0.216 0.0311 Average 0.242 0.0349 Thermal resistance (R, K m2 ) is a function of thickness, and is determined by dividing the thickness in meters by the thermal conductivity. The table below gives the average thermal resistance for a range of practical thicknesses, in both SI and English units: R-VALUE THICKNESS (in.) THICKNESS (mm) R (K M 2 /) R ( F ft 2 h/btu) 1.00 25.4 0.728 4.14 2.00 50.8 1.457 8.27 3.00 76.2 2.185 12.41 4.00* 101.6 2.913 16.54 5.00 127.0 3.642 20.68 6.00 152.4 4.370 24.81 Note: These results are based on the average thermal transmission of all three samples. * This is the average tested thickness of 3 samples. COLD & HOT MEAN TEMPERATURES SAMPLE NO. MEAN TEMP. F MEAN TEMP. C 1 77.0 25.0 2 76.5 24.7 3 77.0 25.0 Average 76.8 24.9

Amerrock Products, LP Page 9 of 10 The tables below illustrate the constants to convert from standard SI units to any of the other commonly used units. To convert from any set of units in the left-most column to any of the sets of units along the top row, multiply by the constant in the intersecting square: THERMAL CONDUCTIVITY, l (SI Units = m K ) m K cm K cal s cm K kg-cal h m K Btu h ft F Btu in h ft 2 F m K 1 1 x 10 2 2.388 x 10 3 0.8598 0.5778 6.933 cm K 100 1 0.2388 85.98 57.78 693.3 cal s cm K 418.7 4.187 1 360 241.9 2903 kg-cal h m K 1.163 1.163 x 10 2 2.778 x 10 3 1 0.672 8.064 Btu h ft F 1.731 1.731 x 10 2 4.134 x 10 3 1.488 1 12 Btu in h ft 2 F 0.1442 1.442 x 10 3 3.445 x 10 4 0.124 8.333 x 10 2 1

Amerrock Products, LP Page 10 of 10 THERMAL RESISTANCE, R (SI UNITS = K m2 ) K m 2 K cm 2 K cm 2 s cal K m 2 h kg-cal F ft 2 h Btu K m 2 1 1 x 10 4 4.187 x 10 4 1.163 5.678 K cm 2 1 x 10 4 1 4.187 1.163 x 10 4 5.678 x 10 4 K cm 2 s cal 2.388 x 10 5 0.2388 1 2.778 x 10 5 1.356 x 10 4 K m 2 h kg-cal 0.8598 8.598 x 10 3 3.6 x 10 4 1 4.882 F ft2 h Btu 0.1761 1.761 x 10 3 7.373 x 10 3 0.2048 1 V. UNCERTAINTY OF METHOD The uncertainty of the Rapid-k apparatus is estimated to be 4% at the two standard deviation level.