Results of the Validation Study for Determination of. Trace Metals at EPA Water Quality Criteria Levels

Similar documents
Results of the EPA Method 1631 Validation Study

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

TNI V1M Standard Update Guidance on Detection and Quantitation

EPA's Revision to the 40 CFR Part 136 Method Detection Limit (MDL) Procedure

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

ALLOWAY METHOD OUTLINE

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

ACZ Laboratories, Inc Downhill Drive Steamboat Springs, CO (800)

Ambient Air Sampling Program Second Quarter 2015 Report Sudbury, Ontario. Submitted to:

Method Update Rule of 2015: New Method Detection Limit MDL Determination. David Caldwell OK DEQ Laboratory Accreditation Program

IMPROVE DETECTION AND QUANTITATION. Richard Burrows

Appendix A. Glossary of Definitions, Acronyms, Abbreviations and Symbols. March 1997

VOTING DRAFT STANDARD

TNI Standard; EL-V1M4 Sections and (Detection and Quantitation) page1 of 8. TNI Standard VOLUME 1 MODULE 4

Table of Contents I. PURPOSE AND SCOPE:... 3 II. AUTHORITY:... 3 III. REFERENCE:... 3 IV. RESPONSIBILITY:... 3 V. POLICY:... 3 VI. PROCEDURE:...

QUALITY CONTROL CRITERIA FOR CHEMISTRY EXCEPT RADIOCHEMISTRY.

Qualification Code Reference Table Cont.

Method Update Rule (MUR) impact on Detection Limits

QA/QC in the Wastewater Laboratory. Steve Roberts Ohio EPA Division of Environmental Services 05/11/2016

Is the laboratory s pledge or declaration of the quality of the results produced. to produce data compliant with the Safe Drinking Water Act (SDWA)

OBJECTIVE DATA PACKAGE DELIVERABLES

Timberline Ammonia-001. Determination of Inorganic Ammonia by Continuous Flow Gas Diffusion and Conductivity Cell Analysis

EPAs New MDL Procedure What it Means, Why it Works, and How to Comply

Hach Company TNTplus TM Phosphorus Spectrophotometric Measurement of Phosphorus in Water and Wastewater

Method 0060 or Method 29. Method for Determining Metals and Mercury Emissions in Stack Gas

Ambient Air Sampling Program First Quarter 2016 Report Sudbury, Ontario. Submitted to:

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

Laboratory 101: A Guide to Understanding your Testing Laboratory

ESTIMATION OF ANALYTICAL METHOD DETECTION LIMITS (MDL)

The following procedures describe how application managers will review chemical additives during the permit application review phase.

Standard Operating Procedure for the Analysis of Dissolved Inorganic Carbon CCAL 21A.1

Review and Reporting of Chemical of Concern (COC) Concentration Data Under the TRRP Rule (30 TAC 350)

Alkalinity, USEPA by Flow Injection Analysis (FIA)

Examples of Method Validation Studies Conducted in Different Economies

Application of Detection and Quantification Concepts to Chlorine Residual Measurements

EPA Office of Water Method Update Rule Final August 28, 2017 William Lipps October 2017

Water Quality Reporting Limits, Method Detection Limits, and Censored Values: What Does It All Mean?

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction

How s that *new* LOD Coming? Rick Mealy WWOA Board of Directors DNR LabCert

Entry Guide for "DIC RAW MATERIAL SURVEY" for Form Version 4.1

ANALYSIS CERTIFICATE OF

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

ISO INTERNATIONAL STANDARD. Water quality Determination of trace elements using atomic absorption spectrometry with graphite furnace

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

LOW-RANGE TOTAL CHLORINE

Glossary of Common Laboratory Terms

Anand pointed out that the adjournment time in Section 6 should be EDT.

Enclosed is a copy of your laboratory report for test samples received by our laboratory on Thursday, February 25, 2010.

NUCLEAR REGULATORY COMMISSION [NRC ] Instructions for Recording and Reporting Occupational Radiation Dose Data

SeCtiOn 5 [STOCK AND CUSTOM] Assurance. Multi-Element CLP Standards

LAMBTON SCIENTIFIC (A Division of Technical Chemical Services Inc.)

METHOD TRACE ELEMENTS IN WATER, SOLIDS, AND BIOSOLIDS BY STABILIZED TEMPERATURE GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Utilizing Data Trend Evaluations in Method Audits and Regulations Development

ACCURACY is the nearness of a result or the mean of a set of results to the true or accepted value.

Method April 1995

ENVIRONMENTAL LABORATORY SECTOR VOLUME 1 MANAGEMENT AND TECHNICAL REQUIREMENTS FOR LABORATORIES PERFORMING ENVIRONMENTAL ANALYSIS

Proposed Procedures for Determining the Method Detection Limit and Minimum Level

Laboratory Quality Control Report: Why is it Important?

Seawater Extraction Procedure for Trace Metals

Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS

APPENDIX II QUALITY CONTROL SUMMARY TABLES

Laboratory ID. Laboratory Name. Analyst(s) Auditor. Date(s) of Audit. Type of Audit Initial Biennial Special ELCP TNI/NELAP.

Chlorine, Free and Total, High Range

METHOD 3600C CLEANUP

The New MDL Procedure How To s. Presented by: Marcy Bolek - Alloway

ANALYTICAL REPORT. Job Number: Job Description: Old Douglas Harbor. For: PND Engineers, Inc West 36th Ave. Anchorage, AK 99503

Standard Operating Procedure for: ph using Oakton ph 5+ Handheld ph Meter. Missouri State University. and

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

ANALYTICAL REPORT. Job Number: Job Description: Old Douglas Harbor. For: PND Engineers, Inc West 36th Ave. Anchorage, AK 99503

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

CCR RULE GROUNDWATER STATISTICAL METHOD SELECTION CERTIFICATION

CCR RULE GROUNDWATER STATISTICAL METHOD SELECTION CERTIFICATION

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

Appendix A - Test Methods Method 301--Field Validation of Pollutant Measurement Methods from Various Waste Media

Schedule. Draft Section of Lab Report Monday 6pm (Jan 27) Summary of Paper 2 Monday 2pm (Feb 3)

Hydra-C Application Note: 1076

Really, A Revised MDL Procedure

Water Quality MDLs, PQLs, and Censored Values What Does It All Mean?

LABORATORY ROUND ROBIN TEST PROJECT: ASSESSING PERFORMANCE IN MEASURING TOXICS IN PACKAGING

Standard Operating Procedure VUSP M

Test Method: CPSC-CH-E

Total Dissolved Residue (Total Dissolved Solids, TDS) in Aqueous Matrices

Standard Operating Procedure for the Analysis of Chloride, Bromide and Sulfate in Fresh Waters by Ion Chromatography CCAL 50B.2

Trace Analysis of Hexavalent Chromium using IC-ICP-DRC-MS

METHOD 6010A INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROSCOPY

Real World Analysis of Trace Metals in Drinking Water Using the Agilent 7500ce ICP-MS with Enhanced ORS Technology. Application. Authors.

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Chlorine, Total. USEPA DPD Method 1 Method to mg/l as Cl 2 Chemkey Reagents. Test preparation. Before starting.

Cyanide Methods for Lachat Automated Ion Analyzers. Flow Injection Analysis

Method Chemical Speciation of Arsenic in Water and Tissue by Hydride Generation Quartz Furnace Atomic Absorption Spectrometry.

Putting the Pieces of the Puzzle Together. By Kim Kirkland, Methods Team Leader EPA s Office of Resource Conservation and Recovery

CCR RULE GROUNDWATER STATISTICAL METHOD SELECTION CERTIFICATION

METHOD 3600B CLEANUP

Transcription:

Results of the Validation Study for Determination of Trace Metals at EPA Water Quality Criteria Levels U.S. EPA Office of Water Office of Science and Technology Engineering and Analysis Division Washington, DC 20460

Results of the Validation Study for the Determination of Trace Metals at EPA WQC Levels 2 Draft, April 1995

Results of the Validation Study for Determination of Trace Metals at EPA WQC Levels Acknowledgments This report was prepared under the direction of William A. Telliard of the Engineering and Analysis Division within the EPA Office of Water. This document was prepared by DynCorp EENSP under EPA Contract No. 68-C3-0337. Other contributors to this study included Interface, Inc., Battelle Marine Sciences Laboratory (Sequim, WA), Battelle Ocean Sciences (Duxbury, MA), Research Triangle Institute, Skidaway Institute of Oceanography, and Texas A&M University's Trace Element Research Laboratory. Disclaimer This report has been reviewed by the Engineering and Analysis Division, U.S. Environmental Protection Agency, and approved for publication. Mention of company names, trade names, or commercial products does not constitute endorsement or recommendation for use. Questions or comments regarding this report should be addressed to: W.A. Telliard USEPA Office of Water Analytical Methods Staff Mail Code 4303 401 M Street, SW Washington, D.C. 20460 202/260-7120 Requests for additional copies should be directed to: USEPA NCEPI 11029 Kenwood Road Cincinnati, OH 45242 513/489-8190

TABLE OF CONTENTS SECTION 1 INTRODUCTION... 1 SECTION 2 STUDY DESIGN... 3 2.1 - PHASE 1 STUDY DESIGN... 3 2.1.1 - Objectives... 3 Table 2-1: Metals to be Tested in Each EPA Method... 4 2.1.2 - Methodology/Approach... 4 2.2 - PHASE 2 STUDY DESIGN... 5 2.2.1 - Objectives... 5 2.2.2 - Methodology/Approach... 5 2.3 - LABORATORIES... 6 SECTION 3 RESULTS... 9 3.1 - Data Reporting, Verification and Validation... 9 3.2 - Phase 1: MDL Results... 9 Table 3-1: Method Detection Limit (MDL) Results from QC Supplement Validation Study... 10 3.3 - Phase 2: Verification of QC Acceptance Criteria... 11 Table 3-2: Verification of QC Acceptance Criteria for Method 200.8 (1638)... 12 Table 3-3: Verification of QC Acceptance Criteria for Method 200.9 (1639)... 13 Table 3-4: Verification of QC Acceptance Criteria for Method 200.10 (1640)... 14 Table 3-5: Verification of QC Acceptance Criteria for Method 200.13 (1637)... 15 Table 3-6: Verification of QC Acceptance Criteria for Method 218.6 (1636)... 16 SECTION 4 DISCUSSION... 17 4.1 - Selection of MDLs for EAD Methods... 17 4.2 - QC Acceptance Criteria... 17 4.3 - Mercury, Arsenic, and Trivalent Chromium (Cr 3+ )... 18 SECTION 5 CONCLUSIONS... 19 APPENDIX A 40 CFR Part 136, Appendix B... 21 4 Draft, April 1995

Results of the Validation Study for Determination of Trace Metals at EPA WQC Levels SECTION 1 INTRODUCTION The Clean Water Act (CWA) requires that ambient water quality criteria (WQC) published by EPA reflect the latest scientific knowledge concerning the physical fate (e.g., concentration and dispersal) of pollutants, the effect of pollutants on ecological and human health and welfare, and the effect of pollutants on biological community diversity, productivity, and stability. Although CWA does not require EPA to consider analytical capability when setting WQC levels, the identification of methods capable of measuring pollutants at WQC levels is an obvious goal. In 1992, EPA promulgated WQC for 14 States at 40 CFR Part 131. (1) This regulation, known as the National Toxics Rule, included numeric criteria for 13 metals. The criteria for some of these metals require measurement capabilities at levels as much as 280 times lower than those achievable using existing EPA methods and required to support technology-based regulations. In order to implement the use of these metals criteria in CWA permits and programs, the Engineering and Analysis Division (EAD), within EPA's Office of Water, was tasked with developing methods for measurement of metals at the lowest WQC levels specified in the National Toxics Rule. In developing such methods, EAD first sought to utilize existing instrumentation and technology to the maximum extent possible. EAD also sought to ensure that the methods would provide the quality control requirements necessary to demonstrate the reliability of data gathered at the low concentrations associated with water quality criteria. Finally, EAD sought to minimize method development costs by basing its approaches on techniques already in use by marine chemists familiar with measuring metals at ambient levels. As a first step towards achieving these objectives, EAD convened a workgroup of recognized trace metal experts from the academic research community, commercial laboratories, Environment Canada, and EPA. The workgroup initially met in November 1993 with the principal objective of identifying the least expensive sampling and analysis techniques that would be likely to yield reliable measurements at WQC levels. During this meeting, several EPA 200-series methods were identified as starting points for the analysis of most of the metals listed in the National Toxics Rule. Meeting participants also identified additional sample handling and quality control techniques that would be necessary to ensure reliable measurements at these levels. Following the November 1993 meeting, EAD drafted a Quality Control Supplement for Determination of Metals at Ambient Water Quality Criteria Levels (the "QC Supplement"). The QC Supplement added rigorous quality control to the procedures found in six EPA 200-series methods. It consisted primarily of (1) additional sampling handling procedures designed to preclude contamination at WQC levels, and (2) additional QC elements designed to define the quality of results at WQC levels and to harmonize the QC elements in the EPA 200-series methods with those found in EPA's 1600- and 600- series wastewater methods. Preliminary QC acceptance criteria for each of the QC elements were developed from performance data given at the end of each 200-series method; these preliminary acceptance criteria were given in Table 2 of the QC Supplement. In August 1994, EAD initiated several single laboratory studies designed to validate the procedures and 1 "Water Quality Standards; Establishment of Numeric Criteria for Priority Toxic Pollutants; States' Compliance" (also referred to as "The National Toxics Rule"), 40 CFR Part 131, (57 FR 60848, December 22, 1992). Draft, April 1995 1

Results of the Validation Study for the Determination of Trace Metals at EPA WQC Levels QC acceptance criteria detailed in the QC Supplement. Although the QC Supplement was initially drafted to supplement six EPA 200-series methods, EAD chose to validate only five of these methods because (1) it was believed that these five methods would yield detection limits necessary to provide reliable measurements at WQC levels and (2) the methods employed technologies that were both widely available and cost-effective for single element and for multi-element determinations. (2) The methods validated and the technologies that they employ are as follows: Method 200.8: Inductively coupled plasma/mass spectrometry (ICP/MS) Method 200.9: Stabilized temperature graphite furnace atomic absorption spectrophotometry (STGFAA) Method 200.10: Chelation preconcentration and ICP/MS Method 200.13: Chelation preconcentration and STGFAA Method 218.6: Hexavalent chromium by ion chromatography EAD's intent in conducting these validation studies was to verify that the procedures outlined in the supplemented methods were capable of yielding reliable data at WQC levels, and to use the study results to develop 1600-series methods that integrate the procedures in the QC Supplement with those contained in the 200-series methods. This report gives the results of EAD's validation studies. 2 The two methods that cover the most metals (Methods 200.8 and 200.9) had been promulgated for use in EPA's drinking water programs at 40 CFR 141.23(k)(1) on December 5, 1994 (59 FR 62456). These methods, and Method 218.6, are also scheduled for proposed use in EPA's wastewater program at 40 CFR Part 136 in late 1995. 2 Draft, April 1995

Results of the Validation Study for Determination of Trace Metals at EPA WQC Levels SECTION 2 STUDY DESIGN In order to minimize costs, the studies described in this report were designed as single laboratory studies aimed at providing EAD with some level of verification that the procedures and QC acceptance criteria specified in the draft QC Supplement could be met by environmental laboratories. To further minimize costs, each single laboratory study was conducted in two phases. In the first phase, each laboratory was to attempt to achieve the target method detection limit (MDL; 40 CFR 136, Appendix B) or to come as close as possible to the target MDL. Target MDLs were set at one-tenth the lowest water quality criterion for each metal. In the second phase, each laboratory was to validate the preliminary QC acceptance criteria given in Table 2 of the QC Supplement. Performance of the second phase was contingent upon successful completion of the first phase. Details of the two-phase design are given in Sections 2.1 and 2.2 of this report. To the extent that costs and schedules would allow, the single laboratory validations of each supplemented method were performed concurrently by more than one laboratory. More extensive interlaboratory method validation studies may be performed at some later date, if warranted. The original study design is fully described in a study plan dated June 1994. (3) This study plan was supplemented with a statement of work (SOW) to describe specific technical requirements to be followed by each contract laboratory performing these studies. (4) The final study design is summarized below. 2.1 - PHASE 1 STUDY DESIGN The first phase of the study focused on the use of spiked reagent water to demonstrate the ability of supplemented EPA methods to yield MDLs less than or as close as possible to one-tenth the lowest WQC levels published in the National Toxics Rule (target MDLs). Where appropriate, the WQC levels listed in the National Toxics Rule were adjusted for dissolved levels and a hardness of 25 mg/l CaCO 3. The technical approach for Phase 1 is as follows. 2.1.1 - Objectives The objectives of Phase 1 were to: (1) Confirm that the QC Supplement could be combined with EPA Methods 200.8, 200.9, 200.10, 200.13, and 218.6 to provide the sample handling and quality control procedures necessary to achieve the target MDLs for the metals listed in Table 2-1; (2) Attempt to achieve, or approach as closely as possible, the target MDL in a minimum of one and as many as three experienced and available laboratories; 3 Study Plan for Validating the Quality Control Supplement for Determination of Metals at Ambient Water Quality Criteria Levels, June 1994. Copies of this study plan are available from the Sample Control Center (operated by DynCorp EENSP), 300 N. Lee Street, Alexandria, VA 22314, (703) 519-1140. 4 Statements of Work for "Validation of the Quality Control Supplement for Determination of Metals at Ambient Water Quality Criteria Levels" and "Validation of the Quality Control Supplement for Determination of Metals at Ambient Water Quality Criteria Levels and Determination of Chromium VI by EPA Method 218.6," DynCorp EENSP (formerly Dyncorp Viar Inc.). Draft, April 1995 3

Results of the Validation Study for the Determination of Trace Metals at EPA WQC Levels (3) Identify method/analyte combinations that should be the target of further study in Phase 2; and (4) Identify further method development needs. Table 2-1: Metals to be Tested in Each EPA Method Method Number Metal(s) 200.8 antimony, arsenic, cadmium, copper, lead, nickel, silver, thallium, zinc 200.9 antimony, cadmium, nickel, selenium, zinc 200.10 cadmium, copper, lead, nickel 200.13 cadmium, lead 218.6 hexavalent chromium As can be seen from Table 2-1, MDL studies were conducted for some metals by more than one method. This approach was taken wherever schedule and resource constraints permitted in order to maximize the number of methods that could be demonstrated to provide the required detection levels. Maximizing the number of methods can provide increased flexibility for permit writers, permittees, or other groups seeking to determine metals concentrations at ambient criteria levels. 2.1.2 - Methodology/Approach Each laboratory was instructed to perform the MDL determination in accordance with the procedures given in 40 CFR 136, Appendix B - Definition and Procedure for the Determination of the Method Detection Limit - Revision 1.11. This procedure, which is provided in Appendix A of this report, involves the analysis of at least seven replicate samples that are spiked to contain the target analyte(s) at a concentration of one to five times the estimated MDL. Laboratories performing these studies were required to notify EPA's Sample Control Center (SCC) of their estimated MDLs and spike levels prior to commencing these studies. (5) Following SCC concurrence with these spike levels, each laboratory prepared a spike solution containing the target compound(s) at the designated concentrations. This solution was then spiked into a reagent water sample to produce seven spiked replicate aliquots. In order to verify that the spike level chosen was appropriate, laboratories were instructed to perform the two-aliquot test described in step 4b of the MDL procedure and report the results of that test to SCC. If the first two measurements indicated that the sample concentration was not in the correct range, the laboratory was required to repeat step 4b (analysis of two spiked aliquots) until the desired spike level was achieved. If the results of this test indicated that the spike levels chosen were in the desirable range for determination of the MDL, laboratories were instructed to proceed with analysis of the five remaining aliquots. All seven measurements were then used for calculation of the MDL. 5 The Sample Control Center (SCC) is operated by DynCorp EENSP under EPA Contract 68-01-0337. 4 Draft, April 1995

Results of the Validation Study for Determination of Trace Metals at EPA WQC Levels 2.2 - PHASE 2 STUDY DESIGN The second phase of the study focused on validating the QC acceptance criteria contained in the draft QC Supplement. This phase was pursued for only those method/metal combinations that yielded MDLs less than or close to the MDLs targeted in Phase 1. Specific objectives for this phase are summarized below and are followed by a brief summary of the design for this phase. 2.2.1 - Objectives The primary objectives of Phase 2 were to: (1) Determine if the QC acceptance criteria specified in Table 2 of the QC Supplement were reasonable for the metal and method combinations to be evaluated in this phase of the study. The Table 2 QC specifications included acceptance criteria for initial precision and recovery (IPR) analyses, calibration verification (VER), ongoing precision and recovery (OPR) analyses, and matrix spike (MS) and matrix spike duplicate (MSD) analyses. (2) Determine the minimum level (ML) of quantification for each of the metal/method combinations to be evaluated in this phase of the study. (3) Establish the lowest calibration point at a rounded value equal to or slightly less than the ML derived from the Phase 1 MDL data. (4) Identify further method development needs. (5) Identify and make further revisions needed to the QC Supplement. (6) Develop technical details and language for new 1600-series methods that integrate the 200-series methods with the revised QC Supplement. 2.2.2 - Methodology/Approach The Phase 2 study design was centered around the use of the QC Supplement and the referenced 200- series methods to analyze four spiked reagent water replicates and two spiked aqueous field sample replicates. The results of the reagent water analyses were used to assess the precision and accuracy that could be achieved using the QC Supplement and the referenced methods. The results of the spiked field sample replicates were used to assess the precision and accuracy of the method in a real world matrix. Laboratories were instructed to follow all QC requirements and analytical procedures stated in the QC Supplement and the referenced methods. The results of these associated QC analyses (e.g., blanks, calibration verification, etc.) were used to further assess the validity of the method and the performance of the laboratories. For the purpose of this study, an interim ML was calculated by multiplying the MDL determined in Phase 1 by 3.18. This 3.18 value is the ratio between the Student's t multiplier used to determine the MDL (3.143) and the 10 times multiplier used by the American Chemical Society (ACS) to establish the limit of quantitation (LOQ). For example, if the MDL found is 7.6, the interim ML would be equal to 7.6 times 3.18, which equals 24.4. To simplify calibration, the interim ML was rounded to the number nearest to (1, 2, or 5) x 10 n, where n is an integer. In the example above, the interim ML (24.4) would be rounded to Draft, April 1995 5

Results of the Validation Study for the Determination of Trace Metals at EPA WQC Levels 20. In cases where more than one laboratory conducted a Phase 1 MDL study for the same metal/method combination, the highest MDL was generally chosen for calculation of an ML that would be used by all laboratories in Phase 2. In accordance with Section 10.1 of the QC Supplement, the laboratories were instructed to initially calibrate each instrument with a minimum of three calibration points. One of these points was to be near the upper end of the linear range, and another was to be at or slightly below the ML. Each laboratory was also instructed to create IPR and OPR solutions containing the metal of interest at two times the rounded ML. This level was consistent with those specified in Sections 9.2 and 9.6 of the QC Supplement. Field samples used for the performance of MS/MSD analyses were collected from sources known to contain the metal(s) of interest at ambient concentrations at or below the levels of interest in this study. To ensure that the samples used for the performance of MS/MSD analyses were not contaminated during sample collection and transport, the samples were collected by marine research laboratory personnel who are highly experienced in the collection and analysis of samples at ambient WQC levels. After determining the background concentration, the laboratories prepared matrix spike and matrix spike duplicate samples at a concentration of 1-5 times the rounded ML or 1-5 times the background concentration, whichever was higher. Generally, the IPR, OPR, and MS/MSD analyses were performed in accordance with the procedures described in the QC Supplement, the applicable EPA analytical method, and the SOW. In a few cases, a laboratory either spiked the IPR or OPR at a level higher than 2 times the rounded ML or did not calibrate at the ML. In these instances, the other laboratories participating in the study performed the analyses correctly and were able to meet all QC acceptance criteria. Difficulties encountered during the course of analysis were conveyed to SCC and, if appropriate, instructions were given to modify the procedures written in the supplemented EPA method, and document any changes. As warranted by the analytical data, all such changes were used to revise the methods that resulted from this study. 2.3 - LABORATORIES Four laboratories performed the Phase 1 and Phase 2 studies. These laboratories were Battelle Ocean Sciences (Battelle), Skidaway Institute of Oceanography (Skidaway), Texas A&M University's College of Geosciences (Texas A&M), and Research Triangle Institute (RTI). Within Battelle, some tests were performed at the laboratory in Duxbury, Massachusetts, and others at the laboratory at Sequim, Washington. The four laboratories were chosen because of their expertise, their experience in the determination of trace metals, their availability, and the prices bid to perform the analyses required in the study plan and SOW. Based on discussions with the laboratories at the inception of the study it was recognized that, because some laboratories did not have all of the equipment necessary and some laboratories had old equipment, all laboratories would not be able to achieve all target MDLs for all analytes in all methods. Therefore, if the laboratory stated that it believed that it could achieve the MDL for a given metal in a given method, or was willing to make a good-faith attempt, that laboratory was contracted to proceed. Also, any laboratory was free to decline attempting to achieve the MDL for any given metal and was free to decline testing with any given method. Although use of alternative methods was prohibited, laboratories were authorized to utilize the flexibility given in Section 9.1.2 of the QC Supplement. For example, instead of using the Dionex column specified in Methods 200.10 and 200.13, Skidaway used 8-hydroxyquinoline immobilized 6 Draft, April 1995

Results of the Validation Study for Determination of Trace Metals at EPA WQC Levels on silica gel, and Battelle used a APDC/cobalt precipitation technique for preconcentration. Similarly, Texas A&M replaced the off-line preconcentration technique specified in Method 200.13 with a reductive precipitation technique developed by the National Research Council of Canada. In all cases, laboratories were required to inform SCC of any proposed changes to the methods (including those within the scope of flexibility allowed by Section 9.1.2) and document those changes in writing. Based on these conditions, a total of two laboratories (Battelle and Skidaway) attempted to validate the supplemented procedures in Methods 200.8 and 200.10, and three laboratories (Battelle, Skidaway, and Texas A&M) attempted to validate the supplemented procedures in Methods 200.9 and 200.13. Validation of Method 218.6 was performed in accordance with a separate study; therefore only one laboratory (RTI) validated the supplemented procedures in this method. If a given laboratory was unable to achieve or approach the MDL in Phase 1, that laboratory was not authorized to proceed with Phase 2. This occurred in only two instances. Due to uncontrollable contamination problems, Texas A&M did not perform the zinc analyses for Method 200.9. In addition, due to a high MDL, Texas A&M did not continue with Phase 2 for lead analyses by Method 200.13. Draft, April 1995 7

Results of the Validation Study for Determination of Trace Metals at EPA WQC Levels SECTION 3 RESULTS 3.1 - Data Reporting, Verification and Validation Laboratories were instructed to report results in accordance with requirements in the SOW. These requirements included submission of: C C C C C A written report detailing problems with, or deviations from, the referenced methods; problems associated with the analysis of specific samples; and comments on the performance of the method on each metal studied. A list of samples analyzed and a run chronology. Summary reports of all analytical results in a format specified by SCC. Copies of all raw data, including quantitation reports, strip charts, spectra, bench sheets and laboratory notebooks showing tare and sample weights, sample volumes, solvent volumes and other data allowing the final results reported to be traced back to the analytical steps performed. MDL values reported to three significant figures. Data received were checked against the requirements in the SOW and study plan. Completeness of the data submissions was verified by ensuring that all required data were present, including results of all required tests, sample lists, run chronologies, summaries of analytical results, raw data, and copies of laboratory notebooks. Validation of data was performed by comparing each required data element to the requirements of the SOW. This included verification that (1) reagent water and ambient water samples were utilized as appropriate, (2) proper spike levels were used in the MDL studies and QC analyses, (3) the instruments were properly calibrated and that other method procedures were followed, and (4) the MDL was calculated per the MDL procedure. In those instances in which the requirements in the SOW were not met, an explanation was provided in the narrative report or was resolved through subsequent discussions with the laboratory. 3.2 - Phase 1: MDL Results The MDLs and other data produced in these validation studies were ultimately used by EAD to prepare draft 1600-series methods that integrated the procedures given in the QC Supplement with those in the referenced 200-series methods on which the 1600-series methods were based. These draft 1600-series methods were released in April 1995. Table 3-1 lists the target MDL and the MDLs obtained from each laboratory in Phase 1, as well as the MDL actually used in the versions of the 1600-series methods resulting from this study. Each 1600-series method is denoted in parentheses next to the 200-series method on which it is based. As can be seen from Table 3-1, the MDLs in the EAD methods reflect the results obtained in this study, with two exceptions. The selenium MDL in Method 1638 was erroneously listed as 1.2 Fg/L; the MDL should be 0.45 Fg/L. The cadmium MDL in Method 1637 was incorrectly listed as 0.0074 µg/l; the correct MDL is 0.0075 µg/l. Draft, April 1995 9

Table 3-1: Method Detection Limit (MDL) Results from QC Supplement Validation Study units = µg/l Sb Cd Cr 6+ Cu Pb Ni Se Ag Tl Zn Target MDL (1) 1.4 0.032 1.05 0.25 0.014 0.71 0.5 0.031 0.17 2.8 Method 200.8 (1638) Battelle 0.00968 0.0127 --- 0.0868 0.0143 0.0742 0.390 0.0289 0.00785 0.138 Skidaway 0.007 0.025 --- 0.043 0.015 0.332 0.45 0.018 0.007 0.069 1638 MDL 0.0097 0.025 --- 0.087 0.015 0.33 0.45 (2) 0.029 0.0079 0.14 Method 200.9 (1639) Battelle 0.139 0.00509 --- --- --- 0.327 0.339 --- --- 0.143 Skidaway 0.337 0.023 --- --- --- 0.65 0.694 --- --- 0.101 Texas A&M 1.86 0.013 --- --- --- 0.547 0.826 --- --- 0.070 1639 MDL 1.9 0.023 --- --- --- 0.65 0.83 --- --- 0.14 Method 200.10 (1640) Battelle --- 0.00240 --- 0.0241 0.00814 0.0288 --- --- --- --- Skidaway --- 0.00094 --- 0.0083 0.00394 0.013 --- --- --- --- 1640 MDL --- 0.0024 --- 0.024 0.0081 0.029 --- --- --- --- Method 200.13 (1637) Battelle --- 0.00102 --- --- 0.0361 --- --- --- --- --- Skidaway --- 0.0029 --- --- 0.0117 --- --- --- --- --- Texas A&M --- 0.0075 --- --- --- --- --- --- --- --- 1637 MDL --- 0.0075 (2) --- --- 0.036 --- --- --- --- --- Method 218.6 (1636) RTI --- --- 0.23 --- --- --- --- --- --- --- 1636 MDL --- --- 0.23 --- --- --- --- --- --- --- 1 Target MDL is 1/10 WQC level. 2 The MDLs listed for Se in Method 1638 (April 1995) and Cd in Method 1637 (April 1995) are incorrect. The MDLs provided in this table are correct. 10

Results of the Validation Study for Determination of Trace Metals at EPA WQC Levels Table 3-1 also shows that, with one exception, at least one laboratory met the target MDL for each metal in each method. The only exception was for lead by supplemented Method 200.8; in this instance, however, both laboratories came very close to the target. For nearly all analyses, blanks were low enough to not impact significantly the MDL. However, in a few instances, the blank levels were sufficiently high that blank subtraction was performed. The MDL results for each method are summarized in the list below. In this list, the supplemented 200- series method number is followed in parentheses with the number of the integrated 1600-series method. Method No. MDL Results 200.8 (1638): With the exception of lead as described above, both laboratories were able to achieve the target MDLs for all metals listed in Table 2-1. 200.9 (1639): One laboratory met the target MDLs for all five metals; two laboratories met the target MDLs for four of the five metals; and all three laboratories met the target MDLs for three of the five metals. 200.10 (1640): Both laboratories easily met the target MDLs for all four metals. 200.13 (1637): The target MDL for cadmium was met easily by all three laboratories, but only Skidaway met the target MDL for lead. 218.6 (1636): The target MDL of 1.05 Fg/L for Cr 6+ was met easily by RTI. 3.3 - Phase 2: Verification of QC Acceptance Criteria Details of the acceptance criteria verifications are summarized in Tables 3-2 through 3-6 for the five methods. These tables list the target QC acceptance criteria and results for each metal in each method for the IPR, VER, OPR, and MS/MSD tests. In nearly all instances, the laboratories met the QC acceptance criteria for each metal/method combination listed in Table 2-1. Draft, April 1995 11

Table 3-2: Verification of QC Acceptance Criteria for Method 200.8 (1638) all specifications expressed as percent Initial Precision and Recovery (Section 9.2) Metal s X Calibration Verification (Section 10.2) Ongoing Precision and Recovery (Section 9.6) Spike Recovery (Section 9.3) Antimony Target 20 81-120 90-111 79-122 79-122 Skidaway 5.2 104.4 101 104 130/103 (RPD = 5.3) Battelle 5.7 102.5 102 103 118.6/111 (RPD = 4.1) Cadmium Target 13 85-112 91-105 84-113 84-113 Skidaway 1.4 95.3 96 97 106/100.5 (RPD = 5.4) Battelle 11 104.2 103 100 105.5/104 (RPD = 1.2) Copper Target 43 55-141 76-120 51-145 51-145 Skidaway 2.5 85.9 93 112 115/113 (RPD = 0.4) Battelle 4.8 98.5 101 95 112/102 (RPD = 4.5) Lead Target 30 75-140 91-120 72-143 72-143 Skidaway 5.9 99.0 99 107 108/89 (RPD = 8.6) Battelle 6.8 97.3 97 100 94.3/92.3 (RPD = 1.9) Nickel Target 30 71-131 86-116 68-134 68-134 Skidaway 1.1 90.9 91 93 110/90.8 (RPD = 17.3) Battelle 1.8 95 91 90 118/114 (RPD = 2.4) Selenium Target 41 63-145 83-125 59-149 59-149 Skidaway 4.0 111.1 108 118 129/132 (RPD = 1.8) Battelle 8.4 110 77 121 116/124 (RPD = 6.1) Silver Target 19 82-120 91-111 81-121 81-121 Skidaway 1.0 102.5 96 103 77/78 (RPD = 1.1) Battelle 3.1 101.5 87 93 82.3/85.9 (RPD = 4.4) Thallium Target 30 66-134 82-118 64-137 64-137 Skidaway 5.2 101.3 99 124 97.5/92.5 (RPD = 4.5) Battelle 4.2 99.8 102 103 93/93 (RPD = 0) Zinc Target 43 55-142 76-121 46-146 46-146 Skidaway 1.6 101.9 95 118 116/99.5 (RPD = 5.8) 12

Results of the Validation Study for Determination of Trace Metals at EPA WQC Levels Battelle 2.8 86 89 82 115.5/115 (RPD = 0.2) Draft, April 1995 13 13

Table 3-3: Verification of QC Acceptance Criteria for Method 200.9 (1639) all specifications expressed as percent Initial Precision and Recovery (Section 9.2) Calibration Verification (Section 10.2) Ongoing Precision and Recovery (Section 9.6) Spike Recovery (Section 9.3) Metal s X Antimony Target 60 24-144 54-114 18-150 18-150 Skidaway 0 107.0 97.2 101 99/93 (RPD = 5.0) Battelle 1.2 101.2 100.6 104 111.5/110.1 (RPD = 1.2) Texas A&M 3.7 101.0 106 111 96.6/109.1 (RPD = 12.1) Cadmium Target 11 67-142 86-123 64-145 64-145 Skidaway 3.9 96.8 100 100 89/92 (RPD = 3.3) Battelle 2.2 105.8 99.3 106 102/102.4 (RPD = 0.4) Texas A&M 10 94.8 101.8 98 88.1/88.4 (RPD = 0.2) Nickel Target 36 69-141 87-123 65-145 65-145 Skidaway 6.3 110.6 96 85 107.5/85 (RPD = 20.7) Battelle 3.5 103.6 99.8 105 98.9/101 (RPD = 2.1) Texas A&M 10.2 58.8 87.2 120 117.9/107.4 (RPD = 9.3) Selenium Target 31 60-128 77-111 56-131 56-131 Skidaway 6.1 101.1 95.8 96.3 89.5/103 (RPD = 13.8) Battelle 1.9 97.1 95.9 102 81.7/79 (RPD = 3.4) Texas A&M 12.4 100.0 107 132.5 106.3/100 (RPD = 6.1) 14

Results of the Validation Study for Determination of Trace Metals at EPA WQC Levels Zinc Target 19 67-142 86-123 67-142 67-142 Skidaway 14.9 101.3 65 105 80/95 (RPD = 6.7) Battelle 4.7 113.1 96.8 114 100/102 (RPD = 1.2) Draft, April 1995 15 15

Table 3-4: Verification of QC Acceptance Criteria for Method 200.10 (1640) all specifications expressed as percent Initial Precision and Recovery (Section 9.2) Calibration Verification (Section 10.2) Ongoing Precision and Recovery (Section 9.6) Spike Recovery (Section 9.3) Metal s X Cadmium Target 23 75-121 86-110 73-123 73-123 Skidaway 15.9 118 103.4 114 95/77.5 (RPD = 12.3) Battelle 19.6 96.8 97 88.7 85/97 (RPD = 11.7) Copper Target 41 56-139 77-119 53-142 53-142 Skidaway 6.2 118 90.5 110 104/147 (RPD = 7.7) Battelle 4.2 111 106 117.3 90/150 (RPD = 12) Nickel Target 27 74-128 87-115 71-130 71-130 Skidaway 17.2 91.3 99.2 92 79/81.8 (RPD = 1.3) Battelle 4.8 125.1 108 126.7 79.5/87.5 (RPD = 4.3) Lead Target 44 56-144 78-122 52-144 52-144 Skidaway 29.5 134 111.6 111 34.6/45.4 (RPD = 14) Battelle 9.6 106 104 103.7 89.2/93.4 (RPD = 3.7) 16

Table 3-5: Verification of QC Acceptance Criteria for Method 200.13 (1637) all specifications expressed as percent Initial Precision and Recovery (Section 9.2) Calibration Verification (Section 10.2) Ongoing Precision and Recovery (Section 9.6) Spike Recovery (Section 9.3) Metal s X Cadmium Target 23 70-116 81-105 70-116 70-116 Skidaway 5.2 104 101 105 75/87.5 (RPD = 15.4) Battelle 2.0 87.5 103 87.5 92.5/95 (RPD = 2.5) Texas A&M 0.2 134.5 98 147.6 92.4/87.7 (RPD = 5.2) Lead Target 27 63-117 77-103 60-120 60-120 Skidaway 6.5 87 92.4 95 52/36 (RPD = 20.3) Battelle 7.2 89.5 103.6 86 93.5/94.5 (RPD = 2.1) 17

Table 3-6: Verification of QC Acceptance Criteria for Method 218.6 (1636) all specifications expressed as percent Initial Precision and Recovery (Section 9.2) Calibration Verification (Section 10.2) Ongoing Precision and Recovery (Section 9.6) Spike Recovery (Section 9.3) Metal s X Hexavalent Chromium Target 20 80-120 90-110 79-122 79-122 RTI 2.6 101 107 97.5 112/107 (RPD = 4) 18

Results of the Validation Study for Determination of Trace Metals at EPA WQC Levels SECTION 4 DISCUSSION The validation studies described in this report demonstrated that the procedures given in the 200-series methods and the QC Supplement could yield reliable results at the lowest WQC specified in the National Toxics Rule. Based on these findings, EAD chose to proceed with development of five new 1600-series methods that integrated the procedures in the QC Supplement with those in the 200-series methods that were the subject of this study. In developing the 1600-series methods, EAD also integrated comments received from study participants and from Regions, States, and others who had reviewed the methods. 4.1 - Selection of MDLs for EAD Methods In nearly all instances, laboratories were able to achieve the MDLs targeted in Phase 1 of the study. In developing MDLs for use in Phase 2 of the study, and for subsequent publication of MDLs and MLs in the 1600-series methods, EAD chose to utilize the highest MDL obtained for a given metal with a given method. This decision was made to ensure that more than one laboratory would be available for measurement of metals at ambient criteria levels. The only exception to this rule was for Texas A&M's MDL for lead in Method 200.13 (EAD 1637). In this instance, the ML derived from the MDL would have been above the ambient criterion, so the MDL was not used, and Texas A&M was instructed to not perform Phase 2 for Method 200.13. Instead, Battelle's MDL, which was the next highest, was used. In a few instances, the MDL determined for a given metal by a given laboratory was less than five times the spike level used the in MDL procedure. In these instances, the MDL was always well below the target value. The laboratory was not required to repeat the MDL test at a lower spike level because lowering the spike level would have resulted in an even lower MDL and the target had already been met. 4.2 - QC Acceptance Criteria In nearly all instances, the laboratories verified the QC acceptance criteria specified in the QC Supplement for each metal/method combination tested. As was noted above in Section 3.3, at least one laboratory was able to achieve results that met the QC acceptance criteria in nearly all cases. In establishing QC acceptance criteria for each of the new methods, EAD utilized the acceptance criteria specified in the QC Supplement when these criteria were met by each of the participating laboratories. For instances in which one or more laboratories were unable to met the target acceptance criteria, each situation was examined on a case-by-case basis to determine if adjustment of the acceptance criteria was warranted. Acceptance criteria were not changed if (1) problems were related to a laboratory's instrument rather than the method, (2) problems were related to a specific matrix interference, or (3) the result from one or more laboratories met the criterion and the result from the laboratory that failed the criterion was associated with other data that indicated acceptable method performance. The acceptance criteria were adjusted if the data from one or more laboratories suggested difficulties with method performance. The final acceptance criteria can be found in Table 2 of each 1600-series method. 4.3 - Mercury, Arsenic, and Trivalent Chromium (Cr 3+ ) It was recognized at the outset of this study that mercury, arsenic, and trivalent chromium were special Draft, April 1995 19

Results of the Validation Study for the Determination of Trace Metals at EPA WQC Levels cases requiring analytical technologies beyond the scope of the methods employed in this study. Although arsenic was considered in the study plan, the laboratories involved in this study declined to attempt to measure this analyte using the techniques cited. As a result, mercury, arsenic, and trivalent chromium were not determined in this study. Development of methods for the determination of mercury and arsenic were performed separately and resulted in draft Methods 1631 and 1632, respectively. Procedures for the preparation of field samples for Cr 3+ determinations were included in Method 1669: Sampling Ambient Water for Trace Metals at EPA Water Quality Criteria Levels and analytical procedures were included in Method 1639. 20 Draft, April 1995

Results of the Validation Study for Determination of Trace Metals at EPA WQC Levels SECTION 5 CONCLUSIONS The analytical technologies employed in this study were ICP/MS and STGFAA, with and without chelation and preconcentration, for 10 metals and ion chromatography for hexavalent chromium. The results obtained in Phase 1 of the study demonstrate that at least one laboratory can achieve the MDLs published for each metal in the new 1600-series methods. The results also show that the target MDLs can be achieved by ICP/MS, without chelation and concentration, for eight of the nine metals to which ICP/MS and STGFAA are applicable. Study results also suggest that lead is also amenable to ICP/MS analysis at these levels, but chelation and concentration may be required. These findings are encouraging, in that a single analytical technology (ICP/MS) can be used to determine nine of 13 metals in the National Toxics Rule. Because ICP/MS instruments have become widespread over the past decade, the ability to determine metals at ambient criteria levels will be dependent primarily on the cleanliness of sampling techniques and laboratories, rather than on the availability and capability of analytical hardware. The results of the tests in Phase 2 demonstrate that the adjusted QC acceptance criteria in the 1600 series analytical methods are reasonable, and that it should be possible for laboratories performing trace metals determinations to meet these criteria on a routine basis. Draft, April 1995 21

Results of the Validation Study for Determination of Trace Metals at EPA WQC Levels APPENDIX A 40 CFR Part 136, Appendix B - Definition and Procedure for the Determination of the Method Detection Limit - Revision 1.11 (reproduced from the Federal Register, Vol. 49, No. 209, Friday, October 26, 1984) Draft, April 1995 23