arxiv: v1 [physics.ins-det] 3 Feb 2011

Similar documents
Time-Resolved Liquid Scintillation Counting

Measurements of photon scattering lengths in scintillator and a test of the linearity of light yield as a function of electron energy

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

Scintillation Detector

Measurements of Liquid Scintillator Light Yield for Future Neutrino Experiments

arxiv: v1 [physics.ins-det] 29 Jun 2011

MEASURING THE LIFETIME OF THE MUON

Rivelazione di neutrini solari - Borexino Lino Miramonti 6 Giugno 2006 Gran Sasso

XMASS: a large single-phase liquid-xenon detector

arxiv: v1 [physics.ins-det] 27 Feb 2014

Investigation of pulse shapes and time constants for NaI scintillation pulses produced by low energy electrons from beta decay

Survey of the performance of scintillation materials at low temperatures

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

XMASS 1.5, the next step of the XMASS experiment

TIME-RESOLVED LIQUID SCINTILLATION COUNTING

1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer

Cherenkov Detector. Cosmic Rays Cherenkov Detector. Lodovico Lappetito. CherenkovDetector_ENG - 28/04/2016 Pag. 1

Journal of Instrumentation. Related content OPEN ACCESS. To cite this article: M. Dawson et al 2016 JINST 11 P08013

Monte Carlo Simulations for Future Geoneutrino Detectors

Measurements of liquid xenon s response to low-energy particle interactions

Neutrino Oscillations

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

arxiv:astro-ph/ v1 15 Feb 2005

Neutrino Physics with SNO+ Freija Descamps for the SNO+ collaboration

Hands on Project: Large Photocathode PMT Characterization

arxiv: v1 [physics.ins-det] 23 Oct 2007

LAB 4: Gamma-ray coincidence spectrometry (2018)

Overview about the Work with Liquid Scintillators

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

PoS(EPS-HEP2017)074. Darkside Status and Prospects. Charles Jeff Martoff Temple University

DETECTORS. I. Charged Particle Detectors

Distillation purification and radon assay of liquid xenon

Search for Neutrino-less Double Beta Decay with CANDLES

Sensitivity of sodium iodide cryogenic scintillation-phonon detectors to WIMP signals

Gamma Spectroscopy. References: Objectives:

Researchers at the University of Missouri-Columbia have designed a triple crystal

Paolo Agnes Laboratoire APC, Université Paris 7 on behalf of the DarkSide Collaboration. Dark Matter 2016 UCLA 17th - 19th February 2016

Measurement of Mean μ-lifetime

Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber

Neutrino Physics. Neutron Detector in the Aberdeen Tunnel Underground Laboratory. The Daya Bay Experiment. Significance of θ 13

PoS(ICHEP2016)474. SoLid: Search for Oscillations with a Lithium-6 Detector at the SCK CEN BR2 reactor

arxiv:physics/ v1 3 Aug 2006

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

GAMMA RAY SPECTROSCOPY

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Results on geoneutrinos at Borexino experiment. Heavy Quarks and Leptons Yamagata Davide Basilico

arxiv: v1 [physics.ins-det] 27 Sep 2018

The interaction of radiation with matter

MESUREMENT OF MUON LIFETIME USING COSMIC MUON STOPPED IN PLASTIC SCINTILLATOR DETECTOR.

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Synthesis and Characterization of Organic Tellurium Compounds for SNO+ Liquid Scintillator

Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals

THE BEGINNING OF THE END OF AN ERA: Analysis After the Shutdown of the Sudbury Neutrino Observatory

Radiation Detection and Measurement

The 46g BGO bolometer

So, you want to build a neutrino detector?

Basics of a/b Discrimination for Liquid Scintillation Counting

Calibration of Single Phase Liquid Argon Detectors

Radiation (Particle) Detection and Measurement

SEARCH FOR NUCLEARITES WITH THE ANTARES DETECTOR *

Overview of Scintillation Systems

Detectors for astroparticle physics

Neutrinoless Double Beta Decay Search with SNO+

LAAPD Performance Measurements in Liquid Xenon

Background Characterization and Rejection in the LZ Detector. David Malling Brown University IDM 2012 July 25, 2012

1. Neutrino Oscillations

LOW ENERGY SOLAR NEUTRINOS WITH BOREXINO. Lea Di Noto on behalf of the Borexino collaboration

Rice University Physics 332 LIFETIME OF THE MUON I. INTRODUCTION...2! II. MEASUREMENT PROCEDURES...3! III. ANALYSIS PROCEDURES...7!

Science of Nuclear Energy and Radiation a Comprehensive Course for Science Teachers June 22-25, 1998 McMaster University

Synthesis of plastic scintillator. Ildefonso León Monzón Universidad Autónoma de Sinaloa

SCINTILLATION DETECTORS AND PM TUBES

Scintillator phase of the SNO+ experiment

DARK MATTER SEARCH AT BOULBY MINE

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Neutrinoless double beta decay with SNO+

Measuring Cosmic Ray Muon Decay Constant and Flux

Compton Imaging with Coincidence Measurements for Treaty Verification Purposes

Status Report: A Search for Sterile Neutrino at J-PARC MLF (E56, JSNS 2 )

Analysis of γ spectrum

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

Next Generation Scintillation Detectors: Development of Quantum Dot Doped Scintillator. Lindley Winslow University of California Los Angeles

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

Neutron flux measurement using fast-neutron activation of 12 B and 12 N isotopes in hydrocarbonate scintillators

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

The TDCR method in LSC. P. Cassette Laboratoire National Henri Becquerel CEA/LNE, France

Measurement of 39 Ar in Underground Argon for Dark Matter Experiments

Study of absorption and re-emission processes in a ternary liquid scintillation system *

The fast light of CsI(Na) crystals

Oddities of light production in the noble elements. James Nikkel

Search for Dark Matter with Liquid Argon and Pulse Shape Discrimination

THE qualities of liquid xenon (LXe) as an efficient

Measuring the Muon Lifetime

Pulse-shape discrimination and energy resolution of a liquid-argon scintillator with xenon doping

Louis Baum University of Michigan, REU Student Summer UM Nuclear Sciences Group

arxiv: v1 [physics.ins-det] 27 Jun 2017

Neutron Detection. n interactions with matter n detection High/low energy n detectors

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

Gamma Ray Spectroscopy

Background optimization for a new spherical gas detector for very light WIMP detection

EEE4106Z Radiation Interactions & Detection

Transcription:

Nuclear Instruments and Methods in Physics Research A 00 (2018) 1 5 Alogo.pdf Nuclear Instruments and Methods in Physics Research A Scintillation decay time and pulse shape discrimination in oxygenated and deoxygenated solutions of linear alkylbenzene for the SNO+ experiment arxiv:12.0797v1 [physics.ins-det] 3 Feb 2011 Abstract H. M. O Keeffe, E. O Sullivan, M. C. Chen Department of Physics, Engineering Physics and Astronomy, Queen s University, Kingston, Ontario, K7L 3N6, Canada The SNO+ liquid scintillator experiment is under construction in the SNOLAB facility in Canada. The success of this experiment relies upon accurate characterization of the liquid scintillator, linear alkylbenzene (LAB). In this paper, scintillation decay times for alpha and electron excitations in LAB with 2 g/l PPO are presented for both oxygenated and deoxygenated solutions. While deoxygenation is expected to improve pulse shape discrimination in liquid scintillators, it is not commonly demonstrated in the literature. This paper shows that for linear alkylbenzene, deoxygenation improves discrimination between electron and alpha excitations in the scintillator. Keywords: Linear alkylbenezene, liquid scintillator, scintillator timing, pulse shape discrimination, SNO+ 1. Introduction The SNO+ experiment is currently under construction in the SNOLAB facility, located approximately 2 km underground in Sudbury, Ontario, Canada. The detector will consist of 780 tonnes of linear alkylbenzene (LAB) liquid scintillator held in a 12 m diameter acrylic sphere and surrounded by 7000 tonnes of ultra pure light water shielding. An array of 9500 photomultiplier tubes will detect scintillation light produced by particle interactions. Both the acrylic vessel and PMT array were inherited from the Sudbury Neutrino Observatory (SNO) experiment [1]. The SNO+ physics programme will include measurements of low energy solar neutrino fluxes and a search for neutrinoless double beta decay using neodymium [2]. Sensitivity to both requires precise energy and position reconstruction, for which an accurate characterization of the scintillator timing is needed. The scintillator decay time can be used to discriminate between alpha and electron events which occur in the scintillator, helping to exclude backgrounds and further improve sensitivity. Corresponding author: okeeffe@owl.phy.queensu.ca The focus of this paper is the measurement of the timing profile of liquid scintillator that will be used in the SNO+ experiment, namely linear alkylbenzene with 2 g/l 2,5-diphenyloxazole (PPO). Linear alkylbenzene was chosen because of its high flash point, low toxicity and acrylic compatibility. PPO will be added to the LAB at a concentration of 2 g/l as the primary fluor, emitting scintillation light across a wavelength region in which the SNO+ photomultiplier tubes are most efficient. Measurements of scintillator decay times for electron and alpha excitations were made for oxygenated and deoxygenated samples of LAB with 2 g/l PPO. These measurements were made using the single photon sampling technique [3]. This method has been used to derive the decay times of many common liquid scintillators, including pseudocumene [4]. This paper will briefly discuss the theory of the single photon counting method and the experimental apparatus used in this work. Finally, results for each configuration of LAB will be presented and conclusions drawn.

/ Nuclear Instruments and Methods in Physics Research A 00 (2018) 1 5 2 2. Scintillator timing profile When an ionizing particle enters the scintillator, it can excite a linear alkylbenzene molecule which nonradiatively transfers this energy to a PPO molecule. Scintillation light is then emitted over a finite time period, via radiative de-excitation of the excited PPO molecule. The timing profile is a measure of the intensity of scintillation light as a function of time due to a single event. Timing profiles for organic scintillators usually consist of several exponential decay components. Radiative transitions to the ground state are permitted from singlet, but not triplet, excited states. The light produced by the singlet state de-excitation occurs quickly and is associated with the fastest component in the timing profile. When excitation to a triplet state occurs, a number of light producing de-excitation channels are available. For example, two triplet state molecules could collide, allowing simultaneous population of the singlet excited state and decay to the ground state. When compared with the singlet state de-excitation, such processes occur over a longer time period and are therefore associated with the longer timing profile components. The shape of the timing profile is related to the ionization density of the charged particle interacting with the scintillator. The relative contribution of singlet and triplet states to the timing profile depends on the ionization density of the particle. This results in differences in the shape of the scintillation light waveform which can be used to discriminate between particle types. Of particular importance for the SNO+ experiment is discrimination between alpha and electron events in the scintillator. Both solar neutrino and neutrinoless double beta decay events will produce electron-like signals in the detector. The ability to identify alpha events enables their rejection. Since alpha particles produce high ionization density, the proportion of the fast component relative to the slow component is reduced because of ionization quenching [5]. Conversely, due to their lower ionization denisty, the timing profile of electron events is dominated by the fast component. 3. Experimental measurement of the timing profile The timing profile can be measured using the single photon sampling discussed in [3]. In this method, the light produced by a sample of scintillator is observed by two photomultiplier tubes (PMTs) connected to fast timing discriminators. The first PMT observes all events and provides a trigger for the electronics chain. The second PMT is covered by a mask containing a small hole in the centre, which allows single photons to be detected. The unmasked PMT provides a reference (start) time for each event. A finite time later, a single photon is detected by the masked PMT which defines the end of an event. The time difference between the start and stop of each event is recorded. By producing a histogram of these delayed coincidence events, accounting for the background and timing resolution, the timing profile of the scintillator can be obtained. A schematic diagram of the apparatus used in this work is shown in Figure 1. A glass dish containing 50 ml of LAB with 2 g/l PPO scintillator was optically coupled to a 5 cm diameter PMT (Electron Tubes Ltd 9266KB). The second PMT (Electron Tubes Ltd 9266KB) was covered with a mask containing a 1 mm diameter hole. The signal from each PMT was connected to an independent channel of a fast timing discriminator (Phillips 715). The discriminator threshold for each PMT was set by using the discriminator signal to gate an MCA energy spectrum. For the masked PMT, the discriminator threshold was set such that the energy spectrum cut off just below the single photoelectron peak for all runs. For the unmasked PMT, the discriminator threshold was set such that a suitable energy threshold was selected, which was the same for alpha and electron runs. This ensured the zero offset of the timing spectrum was identical for all runs. The output from the unmasked PMT discriminator was connected to the start input of a time to amplitude converter (TAC) (ORTEC 566). The masked PMT discriminator channel was connected to the stop input of the TAC. A range of 500 ns was used for the TAC time window. The output of the TAC was connected to a PC running the Maestro multichannel analyzer (MCA) data acquisition software, which recorded the time difference for each event in terms of MCA channels. Cesium-137 was used to obtain a sample of electrons via Compton scattering of the 662 kev gamma. The discriminator threshold was set to accept the full Compton edge. An americium-241 source was used to produce a sample of alpha events. This source was immersed in the scintillator and the discriminator threshold was set to exclude the 59 kev gamma, but include the full 5.48 and 5.44 MeV (quenched) alpha peaks. Coincidences between the PMTs could be caused by non-scintillation events. To characterize this, complementary background runs were taken before and after each timing run. In a background run, the radioactive source remained in place and the hole in the mask was covered to prevent detection of photons from scintillation. The background spectrum was dominated by fast coincidences from cosmic ray interactions in

/ Nuclear Instruments and Methods in Physics Research A 00 (2018) 1 5 3 Unmasked PMT Masked PMT Scintillator Timing Discriminator Timing Discriminator 64 ns Delay TAC To TAC Stop To TAC Start To PC Figure 1: Schematic of the electronics set up for timing profile measurements. the PMT glass and random coincidences between dark noise events. Each background run was time normalized and subtracted from its corresponding timing run. 4. Timing calibration and resolution The timing resolution was measured by removing the PMT mask, which allowed scintillation light to be recorded by both PMTs simultaneously. This produced a Gaussian distribution of timings, with sigma equal to the timing resolution of the apparatus. Delays ranging from 5 ns to 0 ns were introduced between the discriminator and the stop channel of the TAC. This additional delay shifted the mean of the Gaussian by a given number of MCA channels and the timing calibration was obtained by applying a linear fit to this data. A timing resolution of 1.9 ± 0.2 ns was obtained by fitting a Gaussian distribution to this data along with a conversion factor of 16.98 ± 0.85 MCA bins per nanosecond. 5. Results Measurements of scintillator decay times for electron and alpha excitations were made for oxygenated and deoxygenated samples of LAB+2g/L PPO. Deoxygenated samples were prepared by bubbling dry nitrogen through the scintillator for 20 minutes. To ensure the sample remained free of oxygen for the duration of the experimental run, the PMTs, scintillator and source were enclosed in an acrylic housing through which a slow flow of nitrogen was maintained. Timing profiles for the deoxygenated and oxygenated mixtures are shown in Figure 2. The timing profiles shown in Figure 2 have been peak normalized to facilitate comparison between the two modes of excitation. The first portion of the curve is similar for all curves, but those for alpha excitations appear to fall off more slowly indicating, as expected, the presence of a long tail component. To extract the timing components, a function consisting of three decaying exponentials which were individually convolved with a Gaussian was fitted to the background subtracted data. Fits with fewer exponentials returned a poorer chi squared per degree of freedom and those with more resulted in duplication of timing components. Therefore, three exponential terms were used in each fit. Each convolved exponential was multiplied by a scaling factor which represented the weighting of that component in the fit. The function fitted to the data was 3 i=1 ( x A i exp + 0.25 ) [ ( ( π σ 1+Er f x t i σt 2 i 4σ ( )))] 0.5 t i σ (1) where A i is the scaling factor for each exponential component, t i is the timing component in MCA bins, x is the MCA bin and σ is the timing resolution (equivalent to 1.9 ns). The relative contributions of each component is given by R i = A i t i 3 i=1 A it i (2) where R i is the relative contribution for the ith component of the fit and A i, t i were derived from (1). The TF1 function fitting class, found in the ROOT analysis

/ Nuclear Instruments and Methods in Physics Research A 00 (2018) 1 5 4 Number of events per bin 4 3 Oxygenated alpha Oxygenated electron Deoxygenated alpha Deoxygenated electron 2 0 50 0 150 200 250 300 350 400 450 Time (ns) Figure 2: Alpha and electron timing profiles for oxygenated and deoxygenated samples of LAB + 2 g/l PPO. Oxygenated α Oxygenated e Deoxygenated α Deoxygenated e t 1 (ns) 4.4 ± 0.2 4.3 ± 0.3 3.2 ± 0.2 4.6 ± 0.3 t 2 (ns) 20 ± 1 16 ± 1 18 ± 1 18 ± 1 t 3 (ns) 178 ± 166 ± 11 190 ± 156 ± 9 A 1 520 ± 6 768 ± 12 794 ± 7 753 ± 14 A 2 59 ± 3 59 ± 4 53 ± 3 61 ± 3 A 3 3.3 ± 0.1 0.8 ± 0.1 12.6 ± 0.2 2.2 ± 0.1 R 1 (%) 55 75 44 71 R 2 (%) 28 22 16 22 R 3 (%) 17 3 41 7 Table 1: Summary of timing results for the alpha and electron timing profile fits. Total errors are given. framework was used to perform the fit to the data. A cross check was made using the ROOFIT software also found in ROOT. Results from the TF1 fit are shown in Table 1. Results for the timing components show significant differences between alpha and electron timing profiles for both the oxygenated and deoxygenated scintillators. Oxygen is responsible for quenching the longer lived decay processes. Deoxygenating the scintillator reduces the quenching and thus increases the relative amount of the longest timing component. It is clear that deoxygenation has a greater effect on the timing profile of alpha events. This enhances differences between the timing profiles of electron and alpha scintillation events, implying that pulse shape discrimination should be more effective in deoxygenated samples of linear alkylbenzene. By defining a peak region in the timing distribution and comparing the integral of this region to the total integral, a peak to total ratio could be calculated. To assess the difference between the calculated ratios for alpha and electron events, 300 points were randomly sampled from each timing distribution, which is approximately equal to the number of photons produced by a 5 MeV alpha or 0.5 MeV electron. The ratio was calculated by dividing the number of counts in the peak region by the total counts. Looping over this method many times gave a Gaussian spread. Ratios for both oxygenated and deoxygenated scintillators are shown in Figure 3. In oxygenated linear alkylbenzene, approximately 99% of alphas can be rejected whilst retaining >99% of electrons. In the case of deoxygenated linear alkyl-

/ Nuclear Instruments and Methods in Physics Research A 00 (2018) 1 5 5 Number of events per bin 3000 2500 2000 Oxygenated alpha Oxygenated electron Deoxygenated electron Deoxygenated alpha 1500 00 500 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Peak/Total ratio Figure 3: Peak to total distributions for excitations due to electrons and alpha particles in oxygenated and deoxygenated LAB + 2 g/l PPO. benzene and for the same peak region, >99.9% of alphas can be rejected whilst retaining >99.9% of electron like signals. This proves that removing oxygen from the scintillator leads to improved particle identification and thus rejection of alphas. This is of particular importance in large scale liquid scintillator experiments such as SNO+. 6. Conclusions 7. Acknowledgements The authors would like acknowledge financial support from the Natural Sciences and Engineering Research Council of Canada (NSERC). References [1] SNO Collaboration. Nucl. Instrum. Meth., A449:172, 2000. [2] M.C. Chen. Nucl. Proc. Suppl., 145:65, 2005. [3] L.M. Bollinger. Rev. Sci. Inst., 32:44, 1961. [4] G. Ranucci. Nucl. Instrum. Meth. A, 350:338, 1994. [5] W. R. Leo. Techniques for Nuclear and Particle Physics Experiments. Springer-Verlag, 1987. This work has shown that the scintillator timing profile for linear alkylbenzene contains multiple decay components. The relative amounts and values of these components are sufficiently different for electron and alpha events, that separation and thus discrimination between particle types is possible. By directly comparing measurements of oxygenated and deoxygenated scintillator, it has been demonstrated that removal of oxygen from the scintillator leads to improved particle identification and separation of alpha and electron like events. While deoxygenating scintillator is widely expected to improve pulse shape discrimination, it is not commonly demonstrated in the literature. This work is the first to conclusively show this is the case for linear alkylbenzene, a scintillator which will be used in several large scale neutrino physics experiments, including SNO+.