VD1 CLC. Small Valves DIN-range with a higher k v -value

Similar documents
VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

Multifunctional Thermostatic Circulation Valve MTCV

Calio-Therm NC Type Series Booklet

EPIV electronic pressure-independent characterised control valve EPIV

Electronic pressure-independent characterised control valve EPIV

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

Pressure independent balancing and control valve AB QM DN

Operating Instructions for Digital Manometer. Model: MAN-SD

Pressure independent balancing and control valve AB QM DN

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

Direct-operated 2/2-way compact solenoid valves Type EV210A

Pressure independent balancing and control valve AB QM DN

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Cooling Water Flow Regulator

Solenoid valves Type EVUL

Orifice Plate. Stainless Steel. Flow Data. Herz Valves UK Ltd.

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design

Cooler-Bypass Thermostat Valve, Size 10

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Solenoid valves 2/2-way direct-operated type EV210A

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

close to performances of the turbine gas meters designed for custody transfer measurements.

Surface-mounting thermostats Series ATH

ISEmax CAM40/CAS40. Technical Information

Direct-operated 2/2-way solenoid valves Type EV210B

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Variable swirl diffusers

Pressure Measurement Single-range transmitters for general applications

VK2 volume flow controller Overview

Conductivity sensor for hygienic applications

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil

Thermal-Magnetic Circuit Breaker 2210-S2..

PRO-CLEAN STRATIFIED TANK

Pneumatic Universal. Actuator MOTORIZED VALVES USE TECHNICAL FEATURES OF THE ACTUATOR. Data sheet

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Thermal-Magnetic Circuit Breaker 2210-S2..

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 40 Bars Specifications : Anti blow-out stem PTFE packing Full bore.

Safety valve with unit approval type MV..X.., SV..X..

ED 701 General Industry Pressure Transmitter

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

Operating instructions Vortex flow meter. SVxxx / / 2015

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Surface-mounting Thermostats ATH Type Series

CV3000 Series. Characterized Insert Control Valves

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Circulation valves. An effective partner in the battle to prevent legionella.

XHDU Cassette type fan-coils for double/four pipe connections 1,98-14 kw HYDRONIC TERMINALS

Bettis RGS F-Series. Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators. Product Data Sheet RGS Rev.

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Single Phase Motors Technical Datasheets

ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design

ALC. ALBATROSS Supply air terminal for large airflows

PRODUCT SPECIFICATIONS

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

MAINTENANCE EVALUATION CHECKLIST HYDRAULIC ELEVATORS

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Rotary modules.

Lever-type Dial Test Indicators

Lever-type Dial Test Indicators

Operating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

PR CYCLONE SECONDARY SHUTOFF

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Addendum to ARI Standard , Air Terminals September 2002

Vet Photometer DP 700 Operating Manual. Version V5.9

Section 8 Column radiators

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

Power Resistor for Mounting onto a Heatsink Thick Film Technology

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

Connections Standard. Description

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

University of Moratuwa, Sri Lanka. EE3231: Design of Electrical Installation

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Low Differential Pressure Gage

PHOENIX CONTACT - 04/2016. Features

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

Transcription:

0 EN - Small Valves DIN-range with a higher k v -value VD CLC Valve body made of brass, mat nickel-plated DN, DN 0 and DN Internally and externally threaded (Rp / R) conforming to ISO 7- Manual knob / protective cover included in the delivery Can be combined with motoric SSA -, thermal STA - - actuators CEN0en 07-0- Building Technologies

Use For use in ventilation and air conditioning systems for water-side control of chilled ceilings and terminal units in closed circuits, eg for induction units, fan coil units, small re-heaters and small re-coolers -pipe systems with heat exchanger for heating and cooling 4-pipe systems with separate heat exchangers for heating and cooling In closed-circuit zone heating systems, eg for: Separate floors in a building Apartments Individual rooms Type summary Order Delivery Example: Type reference DN k v-value setting range [m /h) VDCLC 0 9 VD0 CLC 0 0 6 VD CLC 0 6 When ordering, please give quantity, product name and type reference small valves VD0CLC Valves, actuators and accessories are packed separately Equipment combinations ) ) Product Types Data sheet Electromotoric actuators SSA / SSA6 ) / SSA8 N489 Thermal actuators -position Thermal actuators DC 0 0 V SSA9 ) STA / STA7 STA6 N700 N4884 Preadjustment of flow rate: > mm valve stroke If the valve travel is less than mm, self-calibration is not possible and the valve with the actuator remains blocked Preadjustment of flow rate: > 0 mm valve stroke If the valve travel is less than 0 mm, self-calibration is not possible and the actuator generates an error message Mechanical and technical design The valves make possible flow rate preadjustments by limiting the stoke A preadjusting screw with reference numbers from 0 to 7 is located under the protective cover right by the valve stem Gland with preadjusting ring Valve insert Fitting with O-ring 4 Valve plug with soft disk All valves are supplied with a protective cover That cover facilitates shutoff when making the plant pressure test and manual adjustments for improvised plant operation during the construction phase 0Z0 4 /8 Siemens Small Valves CEN0en Building Technologies 07-0-

Engineering notes The reference numbers for preadjustment are given in the table with the k v -values (see page ) and in the valve sizing charts (see page 4) Calculate the volumetric water flow V 00 V 00 Q00 [m /h] 6 T f Define the pressure drop p v00 across the fully open valve Q 00 = heat/refrigeration demand [kw] T = temperature differential [K] 6 = constant of water f = correction factor = for water In most types of plant, a differential pressure p v00 of 00 to 0 bar is adequate ( to 0 kpa) Calculation of the nominal flow value k v k v V 00 [m /h] p v00 = pressure drop across the valve [bar] p v00 Example: Heat demand Q 00 = 47 kw Temperature differential T = 8 K Volumetric water flow V 00 47 6 8 = 0 m /h (0 l/h) Required pressure drop across the valve p v00 = 0 bar Flow 0 kv = 6 m /h 0 Solution According to the chart (refer to «Valve sizing charts») or table with k v -values, the preadjustment required by a VD0CLC valve is 6 Tips Noiseless operation is ensured by a pump that provides no more pressure than is needed to transport the required amount of water To keep the valve free from dirt particles, it is recommended to install a strainer If no pressure drop calculation is executed, preadjustment should be set with a differential pressure p v00 of 0 bar (0 kpa) Siemens Small Valves CEN0en Building Technologies 07-0- /8

Valve data k v -values at the different preadjusted positions [m /h] Reference numbers for preadjustment 0 ) 4 6 7 0 ) Valve stroke [mm] 0 088 07 06 07 098 VDCLC 0 0 06 088 0 46 7 90 VD0CLC 0 0 060 09 8 4 64 8 60 VDCLC 0 0 060 09 8 4 64 8 60 Flow tolerance [± %] 0 60 0 0 0 0 0 0 0 Preadjustments < are not recommended because the stroke resolution is too small Note The k v -values give the volumetric water flow V in m /h passing through the valve at a pressure drop p of bar across the valve The preadjusting ring permits full revolutions The values given in the table (reference numbers 0 ) 0 ) ) define the first revolution After another revolution (reference number 0 ) 6), the stroke still increases to mm (fully open), but the k v values will not exceed 0 ) 0Z0 The valves are supplied with the preadjusting ring fully opened (reference number 0 ) ) To make a preadjustment, the ring must first be fully closed only then can the required reference number be selected The markings on the different types are not necessarily identical 4/8 Siemens Small Valves CEN0en Building Technologies 07-0-

Valve sizing charts VDCLC V 00 [ m /h] 00 00 00 0 0 0 0 00 80 0 08 0 8 [kpa] 0 40 0 0 0 04 0 0 [bar] 4 [mwc] p v00 0 8 4 6 70 ) 0 p v00 p v00 00 0 00 00 0 0 00 0 0 0 00 00 00 00 000 000 V 00 [ l/h] 0 0 0 0 0 0 T = 0 K 04 06 4 6 0 0 Q [ 00 kw] 40 T = 0 K 0D0 VD0CLC VDCLC V 00 [ m /h] 00 00 00 0 0 0 0 00 80 0 08 0 8 [kpa] 0 40 0 0 0 04 0 0 [bar] 4 [mwc] p v00 0 8 4 6 7 0 ) 0 p v00 p v00 00 0 00 00 0 0 0 0 0 00 00 00 00 000 000 V 00 [ l/h] 00 000 0 0 0 0 0 0 0 T = 0 K 04 06 4 6 0 0 40 60 T = 0 K Q [ 00 kw] 0D0 Siemens Small Valves CEN0en Building Technologies 07-0- /8

Mounting notes Orientation To ensure correct functioning of the thermostatic heads and electromotoric actuators, observe the available mounting choices and mounting conditions VD CLC remains open if no actuator is mounted 90 90 476Z6 Maintenance Repair Disposal The small valves are maintenance-free The valves cannot be repaired; the complete units must be replaced The device is considered an electronics device for disposal in terms of European Directive 0/9/EU and may not be disposed of as domestic garbage Dispose of the device through channels provided for this purpose Comply with all local and currently applicable laws and regulations Warranty Application-related technical data are only warranted when used in connection with the Siemens controllers and actuators listed under «Equipment combinations» When using the radiator valves with actuators of other manufacture, any warranty by Siemens becomes void 6/8 Siemens Small Valves CEN0en Building Technologies 07-0-

Technical data Functional data PN class PN 0 Permissible media chilled water, low temperature hot water, water with anti-freeze; recommendation: water treatment to VDI 0 Medium temperature 0 C Perm operating pressure 000 kpa (0 bar) Differential pressure p max max 0 kpa ( bar) Differential pressure p v00 0 kpa (00 00 bar): recommended range Nominal stroke mm Standards, directives and approvals Environmental compatibility Pressure Equipment Directive Pressure Accessories PED 04/68/EU Scope: Article, section Definitions: Article, section Fluid group without CE-marking as per article 4, section (sound engineering practice) ) RoHS conformity compliant EAC Conformity Eurasia Conformity Product environmental declaration (contains data on RoHS compliance, materials composition, packaging, environmental benefit, disposal) Materials Valve body brass CuZn40Pb, mat nickel-plated Fitting brass CuZn40Pb, mat nickel-plated Protective cover polypropylene O-ring EPDM Dimensions / weight refer to «Dimensions» Mounting length EN Thread Rp internally threaded R externally threaded G-thread to ISO 7- to ISO 7- to ISO 8- ) Valves where PS x DN < 000, do not require special testing and cannot carry the CE label Siemens Small Valves CEN0en Building Technologies 07-0- 7/8

Dimensions 0M0 E Rp R D C B A G Dimensions [mm] Thread [inch] Weight [kg] Type DN A B C D E Rp R G VDCLC 6 / / /4 08 VD0CLC 0 6 40 46 4 /4 /4 0 VDCLC 68 04 Published by: Siemens Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 60 Zug Switzerland Tel +4 4-74 4 4 wwwsiemenscom/buildingtechnologies Siemens Switzerland Ltd, 00 Technical specifications and availability subject to change without notice 8/8 Siemens Small Valves CEN0en Building Technologies 07-0-