New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Similar documents
Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Guide to Peptide Quantitation. Agilent clinical research

Agilent 6495 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Highly Sensitive and Rugged GC/MS/MS Tool

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Agilent All Ions MS/MS

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Taking Full Advantage of UHPLC with Agilent 6460A Triple Quadrupole MS. Outline

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Agilent ESI and APCI sources: for polar to non-polar compounds

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Theory and Practical Consequences.

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

Forensic and toxicological drug screening using liquid chromatography-tandem mass spectrometry with MS/MS library based identification

Benzodiazepines and Barbiturates

Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

ABI 3200 Q TRAP LC/MS/MS System

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

WADA Technical Document TD2003IDCR

Powerful Scan Modes of QTRAP System Technology

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Multi-residue analysis of pesticides by GC-HRMS

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Application Note. Abstract. Authors. Environmental

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis

Quantitative Analysis of Opioids Using a Triple-Quadrupole GC/MS/MS

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Mass Spectrometry. Quantitative Mass Spectrometry Chiral Mass Spectrometry

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Application Note. Authors. Abstract. Energy & Chemicals, Biofuels & Alternative Energy

MassHunter TOF/QTOF Users Meeting

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

Agilent Technologies LCMS Portfolio

Automated and accurate component detection using reference mass spectra

Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Matching UHPLC Resolution and Speed with Agilent Ultra High Definition Q-TOF Technology

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

The Agilent 6495 Triple Quadrupole LC/MS: Peptide Quantitation Performance

Advantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis

WADA Technical Document TD2015IDCR

Quantitation of Cystine and Identification of Related Metabolites in White Blood Cells Using a High Resolution Accurate Mass LC/MS Approach

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

2016 iquan Series: Pesticide Quantitation on the Thermo Scientific TSQ Quantiva

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Introduction to the Q Trap LC/MS/MS System

László Tölgyesi LC/MS scientist EFSC Demo Group. International Symposium on Food Safety and Quality: Applications of Nuclear and Related Techniques

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

Types of Analyzers: Quadrupole: mass filter -part1

MassHunter Software Overview

materials analysis Solutions for Your Analytical Business Markets and Applications Programs

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Food & Environmental. Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou SCIEX, Concord, Ontario, Canada

Introduction to LC-MS

pmod An Advanced Protein Deconvolution Algorithm with Automated Peak Modeling for Charge Deconvolution of Mass Spectrometry Data

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS

Translational Biomarker Core

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Transcription:

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses Technical Overview Authors Abstract Peter Stone, Thomas Glauner, Frank Kuhlmann, Tim Schlabach and Ken Miller Agilent Technologies, Santa Clara, CA, USA Multiple Reaction Monitoring (MRM) mode has become the preferred method for the quantitative analysis of known or target compounds using triple quadrupole mass spectrometry. The current solution for MRM analysis uses time segmentation, where a method is divided into a series of time segments and predefined sets of MRM transitions are monitored for each segment. As sample complexity increases (e.g. quantifying very low levels of hundreds of pesticide residues in a wide variety of food matrices), very real practical limitations in the time-segmentation methodology become apparent. A better solution is required. New dynamic MRM methods on the Agilent 6400 Series triple quad instruments create new capability to tackle large multi-analyte assays and to accurately quantify exceedingly narrow peaks from fast Agilent 1200 Series RRLC and 1290 Infinity UHPLC separations. Examples of pesticide analysis and rapid screening of drugs of abuse are highlighted. Dynamic MRM methods yield equivalent, or better, quality data and results as compared to traditional time segment based methods plus easier method development and modification.

Introduction Utilizing multiple reaction monitoring (MRM) with a triple quadrupole tandem mass spectrometer enables extraordinary sensitivity for multi-analyte quantitative assays. The first quadrupole (Q1) selects and transmits a precursor ion with a specific m/z. This ion is then fragmented in the second quadrupole (Q2 collision cell), and a specific product ion with a defined m/z is selected and transmitted in the third quadrupole (Q3). See Figure 1. The combination of a specific precursor mass and a unique product ion is generally an unambiguous and sensitive method to selectively monitor and quantify a compound of interest. Since two stages of mass selection are utilized, MRM assays are particularly useful for the specific analysis of target compounds in complex mixtures and matrices. MRM mode has become the preferred method for the quantitative analysis of known or target compounds. Figure 1: A schematic diagram of MRM mode on a triple quadrupole instrument. The precursor ion is selected in Q1, fragmentation occurs in Q2, and the product ion is selected by Q3. Since two stages of mass selectivity are utilized, there is very little interference from background matrix resulting in excellent sensitivity. The Limitations of Time Segment Methods The current solution to complex sample analysis is time segmentation. A method is developed with multiple predefined time segments and the triple quad MS is programmed to perform MRM assays for only those analytes that elute during each segment. Figure 2 shows an example of a method with four time segments. One set of MRM transitions is analyzed during segment 1, another set during segment 2, etc. The benefit of such a method is that, rather than performing MRM scans for all analytes during the entire method, during any given segment the triple quad only monitors MRM transitions for the analytes that elute in that segment. The result is that there are fewer MRM transitions during each MS scan, allowing the mass spec method to use a longer dwell time and/or to reduce the overall cycle time for each MRM scan so that there are more data points per peak. However, there are some limits to what can be accomplished with time segment methods. As the number of analytes in a method increases, so too will the number of concurrent MRM transitions in each segment. It will be necessary to either reduce the dwell times for these transitions or to increase the cycle time for each MS scan. Reducing dwell times (the amount of time required for the triple quad to analyze a single MRM transition) can compromise MS data integrity by introducing collision cell cross-talk (insufficient clearing of the collision cell between individual MRM experiments such that some product ions from a previous MRM may be detected in the subsequent MRM). Maintaining the same dwell time but increasing the overall MS cycle time may mean that not enough data points are collected during the elution of a very narrow LC peak to allow for reliable quantitation. Both of these factors can lead to compromises in data quality. There is an additional challenge using time segments. In order not to compromise any data, the change from one segment to the next must occur during a time when no peaks are eluting from the LC column. In complex analyses such as pesticide analysis, where many co-eluting peaks are monitored at almost every time point during the chromatogram, this can be a formidable challenge as is highlighted in Figure 2. Furthermore, there is always the risk that adding analytes to a method may require complete redevelopment of a method to introduce these chromatographically quiet zones where segment changes can occur. Figure 2: Dividing the chromatogram into time segments. Detection of a complex pesticide mixture demonstrates the advantages and some of the limitations of time segment based MRM quantitation. 2

Introducing Dynamic MRM Mode Agilent s new and unique analytical method approach is now available on all 6400 Series Triple Quadrupole LC/MS systems. MassHunter acquisiton software allows the user to choose conventional MRM or dynamic MRM mode. Ion transitions and a retention time window for each analyte are stored in a method. MRM transition lists are then built dynamically throughout an LC/MS run, based on the retention time window for each analyte. In this way, analytes are only monitored while they are eluting from the LC and valuable MS duty cycle is not wasted by monitoring them when they are not expected. An added benefit of this approach is that MassHunter MS Optimizer software can readily determine and store optimal transition ions for each target analyte, greatly simplifying dynamic MRM method set up. This approach addresses the limitations of the time segment methods for a large batch of compounds by replacing the group segmentation with individual time windows for every analyte transition and by dramatically reducing, on average, the number of individual MRM transitions that are monitored during each MS scan. This approach is demonstrated in Figures 3-5. Dynamic MRM removes the requirement to resolve compounds to baseline and to create well-defined segments in the chromatogram where no compounds elute. This reduces the potential method impact of adding analytes and of retention time shifts. The inevitability of multiple co-eluting peaks is of lesser concern with dynamic MRM as long as the individual ion transitions are unique. Figure 5 shows an expanded region of the analysis in Figure 3, with 22 compounds eluting between 5.58 and 6.51 min with substantially overlapped peaks. All analytes can be accurately quantified because their ion transitions are mutually exclusive, allowing total exclusion of background and interferences. Figure 3: Dynamic MRM method does not require time segments. Extracted ion chromatogram of a 250 pesticide mix spiked into tap water (500 total transitions, 2.5 pg on-column) using a dynamic MRM method run on a 1290 Infinity LC and a 6460 Triple Quadrupole LC/MS system with Agilent Jet Stream technology. Figure 4: Dynamic MRM methods are based on individual retention time windows for each MRM transition. 24 pesticide transitions from the analysis in Figure 3 are highlighted and their retention time windows are shown. Note that, on average, the number of transitions which are monitored at any point in the chromatogram is dramatically reduced relative to time segment methods, allowing much faster MS scan cycle times. Also note that this MS cycle time is held constant (60 ms in this case) in order to assure the highest possible data quality and quantitative result. 3

The Importance of Constant MS Scan Cycle Time in Dynamic MRM Methods Figure 5: Extracted ion chromatogram of 11 pesticides and 11 qualifier ions. In spite of significant co-elution, well-chosen MRM transitions allow for accurate quantification of all sample components. Agilent s dynamic MRM approach uses a constant sampling time across chromatographic peaks. Even data point spacing with adequate sampling across the peak provides the best and most precise representation of the peak. To maintain a constant cycle time, the individual MRM dwell time is also adjusted to keep a constant sampling rate across all peaks, even though the number of ion transitions being monitored will change dynamically and may vary cycle to cycle, dependent on elution time and the number of concurrent analytes. Because dynamic MRM yields generally fewer concurrent ion transitions per unit time than traditional time segments, MS cycle times can be reduced and individual transition dwell times are typically longer than traditional time segmented methods. While the Agilent 6460 and 6430 Triple Quadrupole LC/MS systems are capable of 1 ms dwell times, this is typically only required in the most extreme assays. Note: with the proprietary axial acceleration technology present on all Agilent triple quadrupole and Accurate Mass Q-TOF collision cells, all product ions are cleared from the collision cell in less than 600 µs so that there is no MRM cross-talk with the shortest dwell times (1). Furthermore, by maintaining a constant dynamic MRM cycle time, MS methods can be matched to analyte peak widths to ensure that a statistically adequate number of data points is acquired for each analyte to yield excellent analytical accuracy and precision. This approach yields uniform data points across any given analyte peak and results in good peak symmetry a distinct improvement over constant dwell time approaches. 4

Dynamic MRM Easily Accommodates Fast UHPLC HPLC or UHPLC separations with the Agilent 1200 RRLC or 1290 Infinity LC systems can reduce method times dramatically without sacrificing peak capacity or chromatographic resolution. Individual peak widths may be reduced to just a few seconds. In the extreme, peak widths may be less than one second wide. Dynamic MRM methods require on average, fewer ion transitions to be monitored concurrently in a chromatogram. MS cycle times are much faster than with time segment methods and allow collection of many data points across narrow peaks, as is shown in Figure 6, for excellent quantitative results. Linearity with dynamic MRM methods is at least as good as traditional time segment approaches. Typically, linear correlation coefficients are excellent and assay linearity exceeds three orders of dynamic range. Figure 7 shows a calibration curve for the pesticide compound oxamyl, with excellent sensitivity, linearity, and dynamic range. Triplicate injections of a 25 pg sample on-column yielded a peak area %RSD of only 1.08. Figure 7: Dynamic MRM methods provide excellent quantitative data. Linearity of oxamyl from 0.1 pg to 100 pg on-column, R2 = 0.9992. Figure 6: Dynamic MRM allows accurate quantification of narrow LC peaks. A pesticide analysis gave this 6-sec wide peak for atrazine (5pg on-column). A dynamic MRM method allowed for collection of sufficient data points to assure an excellent quantitative result. The MS scan cycle time was 350 ms and remained constant across the peak. Quantitative precision showed a peak area %RSD < 3.5 for this compound. 5

Application of dynamic MRM Pesticide Screening A challenging real world application for dynamic MRM is the quantitative analysis of a very complex sample run at ultra high pressure using a high resolution column and a fast gradient. 300 pesticides with internal standards were run on a sub-two micron column with a 15 min gradient at pressures exceeding 800 bar, or 11600 psi. A dynamic MRM method with 600 transitions was created using retention time windows of only 0.5 min. Results of this analysis are shown in Figure 8. Comparison of dynamic MRM with conventional time segment methods reveals an excellent correlation. Eight pesticides were injected in 20 replicates at the 10 pg level and both average area and relative standard deviation were calculated. As shown in Figure 9, the correlation in peak areas derived with both the dynamic and timebased MRM methods was outstanding with R 2 = 0.99992. The peak area relative standard deviations for the time segment based method was less than 6% and less than 4% for the dynamic MRM method. Rapid Screening for Drugs of Abuse A further example of dynamic MRM capability is the fast screening for 100 drugs of abuse in oral fluids over a 5 minute gradient a typical work-place drug test. This is a particularly challenging analysis given the timescale of the assay relative to the number of analytes in the target screen. Further, since qualifier ions and quantifier ions were necessary for confirmatory purposes, a total of 200 dynamic MRM transitions were employed during the analysis, covering classes of analytes such as opiates, amphetamines, cannabinoids and benzodiazepines, among others. In this example, peak widths were approximately 2 sec. A dynamic MRM method using retention time windows of only 12 sec was used. The maximum number of concurrent dynamic MRM transitions was never more than 52. The assay showed excellent sensitivity, (LOD = 23 fg on-column) and linearity. External calibration linearity: (R 2 = 0.9987) for one of the spiked analytes (Prazepam) is described in Figures 11 and 12, respectively. Figure 8: Dynamic MRM analysis allows quantification of 300 pesticides using internal standards in a 15 min method. Data was generated with an Agilent 1200 Infinity LC and 6460 Triple Quadrupole LC/MS system with Agilent Jet Stream technology. Figure 9: Comparing pesticide peak areas with dynamic MRM and time segment based methods. 6

Figure 10. Detection of 10 spiked benzodiazepine drugs in an oral fluid extract using a dynamic MRM method with >200 MRM transitions and 12 sec retention time windows. This study was performed on an Agilent 1290 Infinity LC and 6460 Triple Quadrupole LC/MS system with Agilent Jet Stream technology. Figure 12. Linearity of Prazepam from 23 fg to 100 pg on-column, R 2 = 0.9987. Compound LOD (fg on-column) Clobazam 126 Clonazepam 91.5 Flunitrazepam 47.5 Flurazepam 43.0 Lorazepam 186 Lormetazepam 45.9 Midazolam 1.2 pg Oxazepam 145 Oxazolam 235 Prazepam 23.7 Temazepam 156 Figure 11. Limit of detection (LOD) of Prazepam is 23.7 fg with a S/N of 17.3. 7

Summary New dynamic MRM methods on the Agilent 6400 Series triple quad instruments create new capability to tackle large multi-analyte assays and to accurately quantify exceedingly narrow peaks from fast Agilent 1200 Series RRLC and 1290 Infinity UHPLC separations. The number of MRM transitions is adjusted dynamically throughout the LC run, selecting only transitions with relevant retention time windows. This means that, on average, many fewer MRM transitions are monitored during a typical MS scan than would be the case with a time segment based method with the added benefit that dynamic MRM methods are less demanding to develop and adapt. Fewer transitions allow methods with shorter MS scan cycle times (more scans/second) and the ability to provide excellent quantification of very narrow (even sub-second) RRLC and UHPLC peaks. Importantly, this dramatically shortened MS scan cycle time is kept constant so optimized sampling and consistent accurate quantitation is ensured (the same cannot be said for methods that vary MS scan cycle time). Practically, dynamic MRM methods can be used to accurately quantify hundreds of individual analytes, plus their internal standards and qualifier ions, in a relatively short LC run. Compared to benchmark time segment methods, dynamic MRM methods achieve similar sensitivity, linear dynamic range, and quantitative accuracy, with better precision. Key Points Key enabling technology for fast, accurate LC/MS quantitation of complex samples Matches performance of Agilent 6400 series triple quad with separation power of 1200 Series RRLC and UHPLC with 1290 Infinity LC Many data points collected across very narrow peaks for accurate LC/MS quantitation Constant MS scan cycle time ensures accurate quantitation Equivalent and better quality data and results than traditional time segment based methods plus easier method development and modification with MassHunter Optimizer software Up to 4,000 ion transitions per LC run Diverse applications: pesticide analysis, drug screening, targeted protein quantitation References: (1) Agilent publication 5989-7408EN: Ion optics innovations for increased sensitivity in hybrid MS systems www.agilent.com/chem/qqq For Research Use Only. Not for use in diagnostic procedures. Information is subject to change without notice. Agilent Technologies, Inc. 2009 Published in the U.S.A. June 30, 2009 5990-3595EN