Improve Lab Accuracy for Better Water Analysis

Similar documents
NH 3 -selective electrodes

Ion Selective Electrodes for the Laboratory. Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015

Spectrophotometric Determination of pka of Phenol Red

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Experiment 7 Buffer Capacity & Buffer Preparation

Application Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer

Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste

pka AND MOLAR MASS OF A WEAK ACID

COLE-PARMER LABORATORY CALCIUM ION ELECTRODE INSTRUCTION MANUAL

Titration of a strong acid with a strong base with Cobra4

6 Acid Base Titration

Guide to ph Analysis.

EXPERIMENT 15. USING CONDUCTIVITY TO LOOK AT SOLUTIONS: DO WE HAVE CHARGED IONS OR NEUTRAL MOLECULES? rev 7/09

Determination of the K a of a Weak Acid and the K b of a Weak Base from ph Measurements

Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051

Experiment: Titration

GENERAL INSTRUCTIONS GENERAL PREPARATION

Ka Acid Dissociation Constant Minneapolis Community and Technical College Principles of Chemistry II, C1152 v.1.16

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

Fluoride Sealed Electrode Sensor Bundle Product Number: ENFLU049

GENERAL INSTRUCTIONS GENERAL PREPARATION

O H 3 O 1 1 A. O 1 1 OH (K w

All about ph! Is it as simple as it seems? The ph Workshop. Rick Noone Thermo Scientific Water Analysis Instruments, Orion products May 22, 2014

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

MEASUREMENT: PART II

COLE-PARMER REPLACEABLE MEMBRANE CALCIUM ION ELECTRODES INSTRUCTION MANUAL

Experimental Procedure

Chapter 3 Electrochemical methods of Analysis-Potentiometry

experiment7 Explaining the difference between analyte and standard solutions. Know the definition of equivalence point.

Acid-Base Titration. Evaluation copy

Chem 2115 Experiment #7. Volumetric Analysis & Consumer Chemistry Standardization of an unknown solution, analysis of vinegar & antacid tablets

Glossary of Common Laboratory Terms

COLE-PARMER INDUSTRIAL AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

symphony Multisensor Probes

Identification Of The Common Laboratory Glassware, Pipettes And Equipment. BCH 312 [Practical]

425 Jordan Road SOP. No. 10 Rev. No. 1.3 Troy, NY Date: 03/14/2012 Page 1 of 7

Chemistry MultiMeasure Sensor PS-2170

1) A ph/mv meter or an ion meter, either line operated or portable.

NITROGEN, TOTAL, HR, Test N Tube

CALCIUM SELECTIVE ELECTRODE

Acid-Base Titration. Sample

Appendices towards the Operation Manual of Ultrasonic milk analyzer Lactoscan

Kinetics of Crystal Violet Bleaching

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

PREPARATION FOR CHEMISTRY LAB: FLUORIDE IN WATER

COLE-PARMER LABORATORY CUPRIC ION ELECTRODE INSTRUCTION MANUAL

Nitrogen, Ammonia. Test Preparation. Powder Pillows Method Method 8155 Salicylate Method 1 Powder Pillows

K a Acid Dissociation Constant Minneapolis Community and Technical College Principles of Chemistry II, C1152 v.9.13

COLE-PARMER INDUSTRIAL POTASSIUM ION ELECTRODE INSTRUCTION MANUAL

C = concentration as ppm sulfide V t = volume of titrant at endpoint V s = volume of standard used (10 ml)

Chemistry Determination of Mixed Acids

DR/4000 PROCEDURE NITRATE. 2. The display will show:

Ammonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A

TRATION: ANALYSIS OF VINE

PC Control / Touch Control

MassWWP Standard Operating Procedure L-6 ph and Alkalinity Rev.0 Page 1 of 12

Thermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations

ph electrodes: what users should know

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

Experiment 8 and 9 Weak Acids and Bases: Exploring the Nature of Buffers

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

Volumetric Analysis: Analysis of antacid tablets Analysis of Cl - concentrations in IV solutions

S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0)

COLE-PARMER INDUSTRIAL CALCIUM ION ELECTRODE INSTRUCTION MANUAL

+ H 2 O Equation 1. + NaOH CO 2 Na

Application Bulletin

Introduction to Strong and Weak Acids

Applications of Ion-Selective Electrodes

Basic Analytical Techniques, Calorimeter, and Conductivity Meter

Prince George s Community College PL 2: CHARACTERIZATION OF A MONOPROTIC WEAK ACID BY POTENTIOMETRIC TITRATION

Acid-Base Titration Lab

INTRODUCTION TO ACIDS, BASES AND TITRATION

10 samples per second

MULTI_T. Digital Titrator for Multi-tasking Titrations

Automatic titrators, TitroMatic

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE)

Application Bulletin

Chem 321 Lecture 17 - Potentiometry 10/24/13

F- Cl- Br- I- CN- S2- NO3-

Water & Wastewater. Laboratory Math

Acid-Base Titration. Volume NaOH (ml) Figure 1

NITROGEN, TOTAL, Test N Tube * Method 10071

FC80 Free Chlorine Analyzer ELECTRO-CHEMICAL DEVICES

ph Probes Lab vs. Process Care, Calibrations and Comparison Presented by: Michael Blackburn Technical Sales Specialist at Hach Company

COLE-PARMER LABORATORY AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

H 3 O + (aq) + P 2- (aq)

This lab will be conducted in groups but the lab report must be completed and submitted individually.

Acid-Base Titration. Computer OBJECTIVES

Chem 2115 Experiment #7. Volumetric Analysis & Consumer Chemistry Standardization of an unknown solution and the analysis of antacid tablets

University Wet Chemistry Analyzer Packages

The Oakton Cadmium Ion Electrodes are used to quickly, simply, accurately, and economically measure cadmium ions in aqueous solutions.

Method to 0.50 mg/l NH 3 N Powder Pillows

EXPERIMENT 6. Properties of Buffers INTRODUCTION

Ion Selective Electrode Probe

COLE-PARMER INDUSTRIAL NITRATE ION ELECTRODE INSTRUCTION MANUAL

Method 8326 (0.006 to mg/l Al 3+ ) Powder Pillows

Teaching Buffering by Showing Its Effects

Determining the K sp of Calcium Hydroxide

Operating Instructions for Ammonium ISE Specifications

Transcription:

Improve Lab Accuracy for Better Water Analysis December 14, 2017 Webinar Moderator Nathan Edman Standard Methods Manager American Water Works Association Nathan oversees and manages the electronic and print production of Standard Methods for the Examination of Water and Wastewater and is in charge of a majority of the AWWA chemical standards committees. Nathan received his Bachelor of Science Degree in Chemistry from the University of Arizona. 2 Please consider the environment before printing. 1

Enhance Your Webinar Experience Close Email Programs Instant messengers Other programs not in use GoToWebinar Support http://support.gotomeeting.com/ics/support/default.asp?deptid=5641 3 Webinar Survey Immediately upon closing the webinar Survey window opens Thank you! 4 Please consider the environment before printing. 2

Products or Services Disclaimer The mention of specific products or services in this webinar does not represent AWWA endorsement, nor do the opinions expressed in it necessarily reflect the views of AWWA AWWA does not endorse or approve products or services 5 Panel of Experts Jessica McVay Technical Support Specialist Metrohm USA Lori Spafford Titration Product Manager Metrohm USA 6 Please consider the environment before printing. 3

Agenda I. What is Titration? Jessica McVay II. III. More on Endpoint Detection What s the Big Difference? Buret Titration vs. Autotitration Jessica McVay Lori Spafford IV. Application Tips & Tricks V. So Many Samples, So Little Time Lori Spafford Lori Spafford 7 Ask the Experts Jessica McVay Metrohm USA Lori Spafford Metrohm USA Enter your question into the question pane at the lower right hand side of the screen. Please include your name and specify to whom you are addressing the question. 8 Please consider the environment before printing. 4

Rationale & Objectives Firm up titration and electrode fundamentals Understand how autotitration can improve accuracy Overview of common water analysis tips and tricks Hear about technology improvements for colorimetric titration and high-throughput laboratory needs Identify potential areas of improvement in your lab operations 9 Today s Topics Review fundamentals of titration Understand how electrodes work Getting better results from colorimetric titrations Common water analysis tips & tricks Improving throughput with a new concept in automation Live question and answer 10 Please consider the environment before printing. 5

What is Titration? Fundamental review 11 What is titration? Start T T T Endpoint T T T Finish T T T T Titrant reagent with known concentration A Analyte unknown in sample T T T A A A T A T A T A T A T A T A A A A T A T A T A T A T A T A 12 Please consider the environment before printing. 6

What was titration? Manual additions made by glass buret Manual control controlled by analyst Optical detection for visual confirmation the endpoint has been reached Challenges of Manual Titration Need a neutral background Visibility of indicator in colored samples Consistent decision making between analysts Careful data recording and calculation Even an experienced bench chemist can require 5 minutes per titration Please consider the environment before printing. 7

What is titration now? Advanced dosing, titrating, and liquid handling Sophisticated measuring sensors What is titration now? Thorough data evaluations and management Secured user administration Please consider the environment before printing. 8

Endpoint Detection Different ways to detect Color change mv change Temperature change Some of the challenges Color change is subjective between analysts Hanging burets are difficult to read Manual calculations subject to human error 17 More on Endpoint Detection How do electrodes work? 18 Please consider the environment before printing. 9

Measurements with Electrodes Definition An electrode which produces a voltage dependent (logarithmically) on the concentration of a selected substance. ISE e.g. H (ph electrodes) ISE e.g. F, Cl, Cu, Pb, Surfactant Redox Electrodes Metal Electrodes e.g. Ag, Pt 19 Potentiometric Measurement What is needed? 1. Measuring electrode 2. Reference electrode 3. ph/voltmeter meter 4. Sample Ref. U, mv Meas. Measuring principle: Measurement of potential differences 20 Please consider the environment before printing. 10

Combined Electrode Systems Ref. Meas. Combined How can I tell what type of electrode system I have? Fill port & glass bulb 21 Closer Look at Combined Electrodes electrode head Ag/AgCl cartridge refilling opening glass shaft diaphragm electrode tip glass membrane Please consider the environment before printing. 11

Membrane Layers ph glass electrode responds to H + ions in solution hydrated layer (~0.1 mm) alkaline 23 Same Function, Different Shapes Ball (12 mm) Titration Needle (4 mm) Measurement Half ball (12 mm) Titration Micro cylinder (3 mm) Measurement Cylinder Measurement/ Titration Flat membrane Measurement /Titration 24 Please consider the environment before printing. 12

Reference Diaphragm Electrolyte solution must be in contact with sample solution Outflow of electrolyte due to simple hydrostatic pressure Fill port must be open for this to occur A B Outflow too low (A) Contaminate reference Optimal outflow (B) Must refill electrode regularly 25 Why is calibration needed? Electrode response is a mv signal The mv needs to be correlated to a ph value The factors that influence this relationship are slope and zero point (intercept) 26 Please consider the environment before printing. 13

Why is calibration needed? Aging of the glass membrane of the sensor or blockage of the diaphragm Change of electrode zero point and slope Meter is adapted by calibration to the actual characteristics Calibration should be done frequently 27 Color Changing Titrations Need an Optical Sensor Think hardness titrations Optrode sensor detects color-changing endpoints Wavelength, nm For Color Change To Useable Range 470 Yellow 460 480 502 Orange/Red 485 520 520 Red 505 535 574 Violet/Purple 560 585 590 Blue 575 605 610 Blue/Green 595 625 640 Green 620 655 660 Black/Turbid 650 670 28 Please consider the environment before printing. 14

How the Optrode Works Choose correct wavelengths Connect directly to titrator Sample solution passes through optical window Signal converted to mv reading and is graphed like traditional potentiometric titration 29 What s the big difference? Manual buret titration vs. autotitration technology 30 Please consider the environment before printing. 15

What Matters the Most Achieve accurate results Perform repeatable analysis Reduce or remove human error Achieving Accurate Results Manual Titrations Buret increment limitations Autotitrator Precise buret increments Please consider the environment before printing. 16

Achieving Accurate Results Manual Titrations Manual control of titration speeds Autotitrator Controlled, dynamic titration speeds Performing Repeatable Analysis Manual Titrations Visual decision making Autotitrator Absolute potential measurements Please consider the environment before printing. 17

Performing Repeatable Analysis Manual Titrations Endpoint volumes read by analyst Autotitrator Precise endpoint volumes reported by instrument Performing Repeatable Analysis Example Scenario: Data trending between shift operators Please consider the environment before printing. 18

Reducing Human Error Over titration Manual Titrations Autotitrator Endpoint is never missed Reducing human error Manual Titrations Manual data recording, Manual data recording, calculations, data entry calculations, & data entry Autotitrator Digital data collection, automatic automatic calculations calculations & LIMS upload & LIMS upload Please consider the environment before printing. 19

Application Tips & Tricks Make Lab Analysis Easier! 39 Common Titration & Ion Analysis ph Measurement Conductivity Alkalinity Chlorine Total Hardness Calcium, Magnesium Hardness Ammonia Chloride Fluoride Sulfide 40 Please consider the environment before printing. 20

ph Measurement & Alkalinity Titration Requires electrode calibration Check slope, measure ph buffer Proper electrode storage ensures electrode responds quickly Fill port closed Electrode stored in storage solution not water, buffer solution or electrolyte! 41 ph Measurement & Alkalinity Titration If required to perform hydroxide, carbonate and bicarbonate alkalinity calculations automate as much as possible! Titration Result Hydroxide Alkalinity Carbonate Alkalinity Bicarbonate Alkalinity P = 0 0 0 T P < 1/2T 0 2P T-2P P = 1/2T 0 2P 0 P > 1/2T 2P T 2(T - P) 0 P = T T 0 0 Can all be programmed into titration software 42 Please consider the environment before printing. 21

Hardness Titration Hardness Titration Applies to EPA 130.2 and SM 2340C Complexometric titration using EDTA and color indicator Where s the endpoint? Challenges come with identifying the endpoint Color change is subjective Makes reproducibility difficult Colorblind? 43 Hardness Titration with the Optrode Using an optical sensor set to 610nm Typical titration curve below where endpoint is precisely identified Can automate titration, now! 44 Please consider the environment before printing. 22

Ammonia Using an Ion-Selective Electrode Measured potentiometrically using an ion-selective electrode EPA 350.3 Combined electrode Measuring and reference electrode in one system Gas-permeable, hydrophobic membrane that separates the sample and the measuring electrolyte (<1% NH 4 Cl) 45 Review Ammonia Chemistry NH 3 + H 2 O NH 4 + OH - Excess strong base (NaOH) converts all NH 4 to NH 3 Dissolved NH 3 gas diffuses through membrane causing a mv change until partial pressure is identical Potential change is proportional to NH 3 in sample 46 Please consider the environment before printing. 23

Ion-Selective Electrode Care for Ammonia Rinse electrode after every measurement Condition in DI water for up to ~10 minutes between samples Low-level samples (<1 mg/l) may require up to 30 minutes Store properly For 1-5 days: Store electrode in 0.1M NH 4 Cl For >5 days: Store dry 47 Ion-Selective Electrode Care for Ammonia Before first measurement or after longer storage in dry state Soak inner glass electrode for 6-12 hours in ph 7 buffer After electrode has been fitted with new membrane Shake gently to remove any air bubbles from membrane Soak for 10 minutes in DI water 48 Please consider the environment before printing. 24

Tips for Better Ammonia Measurements Low-level samples will require more time to equilibrate High-level samples may require dilution because ammonia dissipates into the air Insert electrode into sample before adding hydroxide Drifting potential could mean: Membrane is damaged Wrong electrolyte Concentration >1 mol/l Temperature fluctuations 49 So Many Samples, So Little Time New Innovations in Sample Throughput 50 Please consider the environment before printing. 25

Challenges for High-Throughput Labs Short hold times Fast turnaround Emergency/priority samples Using an autotitrator can help but, what if you are already using one? Large batch sizes Multiple analysts required over multiple shifts 51 Solutions for Increasing Sample Throughput Dedicated Analyzer Routine analysis Automated QC Blanks, duplicates, spikes Standards Hands free, walk-away analysis Frees you up for other tasks! Ti-Touch Analyzer 52 Please consider the environment before printing. 26

Solutions for Increasing Sample Throughput Multi-Parameter Analyzer Combine several analytes into one system ph, Alkalinity, Conductivity, Hardness Ammonia, Fluoride Space saving Simplified data handling Environmental Analyzer 53 Solutions for Increasing Sample Throughput Expandable Analyzers Completely expandable and designed to grow with the needs of your laboratory From 18 to 175 samples Automate up to 4 analysis (different or same!) simultaneously OMNIS 54 Please consider the environment before printing. 27

Summary Titration can be improved by converting manual titrations to autotitrations Understanding how electrodes work improves troubleshooting practices Proper storage and calibration of electrodes is critical to ensuring accurate titration data Add a sample changer can improve repeatability, automate QC, reduce re-analysis and free up analysts to perform other tasks 55 Need Additional Information E-mail: Communications@metrohmusa.com Web: www.metrohm.com Questions & Answer 56 Please consider the environment before printing. 28

Ask the Experts Jessica McVay Metrohm USA Lori Spafford Metrohm USA Enter your question into the question pane at the lower right hand side of the screen. Please include your name and specify to whom you are addressing the question. 57 Thank you for Joining this Webinar As part of your registration, you are entitled to an additional 30-day archive access of today s program. Don t forget to fill out the survey immediately following the webinar. 58 Please consider the environment before printing. 29

Presenter Biography Information Lori Spafford is the Product Manager for Titration for Metrohm USA. She has a Bachelor s Degree in Chemistry from St. Joseph s College in Indiana and over 10 years of experience in the chemical, food and beverage, and environmental industries. During her prior three years as an Applications Chemist at Metrohm USA, she has focused on the development of thermometric titration and has successfully brought innovative solutions to difficult applications in a variety of industries. Jessica graduated with a Bachelor of Science Degree in Forensic and Toxicological Chemistry from West Chester University of Pennsylvania. After graduating, her career started in the pharmaceutical industry as a QC chemist. She then moved to Florida to continue her career as an R&D chemist, developing new methods for generic drugs. At Metrohm USA, she is a technical support specialist. She uses her technical skills to help customers troubleshoot their instruments and/or software when they are in need of assistance. 59 CE Credits (CEUs) and Professional Development Hours (PDHs) AWWA awards webinar attendees CEUs. If you wish to take advantage of the opportunity to earn CEUs, visit www.awwa.org/credits Certificates will be available within 30 days of the webinar 60 Please consider the environment before printing. 30

How to Print Your Certificate of Completion Within 30 days of the webinar, login to www.awwa.org or register on the website. If you are having problems, please email educationservices@awwa.org Once logged in, go to: My Account My Transcript Information To print your official transcript, click Print list To print certificates, click Download certificate 61 Please consider the environment before printing. 31