Operating Instructions for Digital Manometer. Model: MAN-SD

Similar documents
DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

ED 701 General Industry Pressure Transmitter

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Pressure transmitters for industrial applications MBS 32 and MBS 33

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Installation guide 862 MIT / MIR

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Pressure Measurement Single-range transmitters for general applications

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Thermal Mass Flow Meter for Gases

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Drive electronics pq12

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

PHOENIX CONTACT - 04/2016. Features

PRODUCT CATALOGUE PREssURE switch

Infrared Hand-Held Thermometers

Cooling Water Flow Regulator

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Industrial Pressure Transmitter

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions:

E8EB-N0C2B E8EB-N0B2B

PAA-ANALYZERS PRINCIPLE OF OPERATION

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Lamp and Control Panel (Lamp Panel)

Pressure Transmitter ED 701

Relative pressure transmitter type 520

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Industrial Resistance Thermometers according to DIN Model MWD

ISEmax CAM40/CAS40. Technical Information

KM-70 Panel-mounting Thermostat

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

Industrial Pressure Transmitter

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Vet Photometer DP 700 Operating Manual. Version V5.9

Operating instructions Vortex flow meter. SVxxx / / 2015

Operating instructions Pressure sensor PN / / 2007

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS

Operating Manual. Turb 355 IR/T. Portable turbidimeter. ba75454e03 09/

ph/redox Measurement CPM 280

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

VD1 CLC. Small Valves DIN-range with a higher k v -value

Conductivity sensor for hygienic applications

Analogue Meters CQ2x07 series

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

Lever-type Dial Test Indicators

Lever-type Dial Test Indicators

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

Infrared Hand-Held Thermometers

ABB i-bus KNX Analogue Input AE/A 2.1

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

WeatherHub2 Quick Start Guide

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

Non-Contact Safety Systems CMS

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids

DIGITAL THERMOMETER OPERATOR S MANUAL

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

EX-EMERGENCY LIGHT FITTINGS

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

PHASED OUT. LED light engines LED linear / area. Module CLE Quadrant G2 ADV Modules CLE ADVANCED

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

473 Dew Point Hygrometer

Field Pro Operation and Installation Manual

792A AC/DC Transfer Standard

Low-Drop Voltage Tracker TLE 4250 G

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

Tunable White LED compact

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

LED light engine / OLED LED compact. Module DLE G4 ADV Modules DLE

Microcare LCD Solar MPPT User Documentation

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

473 Dew Point Hygrometer

Size A DIN EN

32 Input AC Block I/O Module

W250: Compact photoelectric switch series for a broad range of applications

Full Metal Variable Area Flow Meter and Counter

LED light engines LED linear / area. Module CLE Quadrant G3 ADV Modules CLE ADVANCED

Thermometers. Applications

Analog - Digital multimeters

LED light engine / OLED LED linear / area

16 Input AC Block I/O Module

ISEmax CAS40D. Technical Information

Surface-mounting Thermostats ATH Type Series

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE STARK-CLE EM STARK-CLE EM-SO Ø315

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

MKIII -MB USER S GUIDE 09/18/18. Rev. 3

Transcription:

Operating Instructions for Digital Manometer Model: MAN-SD

1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5 7. Electrical Connection...6 8. Function Keys...7 9. Adjustments...7 10. Control Functions...8 11. Maintenance...12 12. Technical Information...12 13. Order Codes...13 14. Dimensions...14 15. Declaration of Conformance...15 Manufactured and sold by: Kobold Messring GmbH Nordring 22-24 D-65719 Hofheim Tel.: +49(0)6192-2990 Fax: +49(0)6192-23398 E-Mail: info.de@kobold.com Internet: www.kobold.com page 2 MAN-SD 03/04

2. Note Please read these operating instructions before unpacking and putting the unit into operation. Follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health & Safety and prevention of accidents. When used in machines, the measuring unit should be used only when the machines fulfil the EWG-machine guidelines. 3. Instrument Inspection Instruments are inspected before shipping and sent out in perfect condition. Should damage to a device be visible, we recommend a thorough inspection of the delivery packaging. In case of damage, please inform your parcel service / forwarding agent immediately, since they are responsible for damages during transit. Scope of delivery: The standard delivery includes: Transmitter with display Operating Instructions 9 Volt block battery (IEC 6 LR 61) MAN-SD 03/04 page 3

4. Regulation Use Any use of the Digital Manometer, model: MAN-SD, which exceeds the manufacturers specification may invalidate its warranty. Therefore any resulting damage is not the responsibility of the manufacturer. The user assumes all risk for such usage. The model MAN-SD serves to measure, monitor and transmit pressuredependent operational processes in machines and systems. These devices are equipped as follows: 4-digit LCD display Three Programming keys Process connection (St. Steel) Power Supply via 9V block battery Limit relays (option) Peak value memory (option) Analogue output (option) 5. Operating Principle A ceramic sensor detects system pressure and sends the signal to evaluation electronics. The sensor signal is conditioned and sent to the LCD display as a pressure reading. Parallel to this, an output is provided as analogue signal for the purpose of transmitting measured pressure. A programmable relay-output is also available as an option. page 4 MAN-SD 03/04

6. Mechanical Connection Before installation: Ensure that the max. pressure in your system is within the prescribed range of the digital manometer. The measuring range can be read from the nameplate label of the device. Make sure that the permitted max. operational temperature of the device is not exceeded. Confirm that there are no fragments of packing material present inside the pressure sensing port. Installation: Ensure that the piping is fully depressurised.. The digital manometer should be mounted just like a mechanical manometer. With standard thread connection, sealing is achieved by means of a suitable gasket (flat-seal or seal-ring DIN 16258). While threading in the device, install by using a wrench on the hexagonal screw (SW 24) and not the gauge housing. If possible, after the mechanical installation, pressure test the piping to determine whether the connection joint is adequately sealed. Attention! The MAN-SD digital manometer must be installed into a grounded system. This action is necessary in order to fulfil the EMVguideline. Flat seal-ring acc. to DIN 16 258 MAN-SD 03/04 page 5

7. Electrical Connection Attention! Please ensure that you use a 9 V alkali-manganese-block battery (IEC 6 LR 61). Make sure that the power supply lines are not active. (Only with option limit-contacts or analogue output.) Open the battery enclosure on the back-side of the unit and connect the 9V block battery with the connection plug. Place the 9V block battery in the enclosure and close it with the lid. Terminate the connection wires on the plug (cable), as shown in the illustration below. (Only with option limit-contacts or analogue output.) Power supply conductor (area of cross-section): min.0.34 mm². Attention! Incorrect wiring will lead to damage of the unit s electronics. Cable No. MAN-SD2... MAN-SD3... Cable colour 1 brown 2 Contact output (Relay in) white 3 GND (0V Reference) blue 4 Analogue output 0-2V DC black 5 Contact output (Relay out) grey plug M12x1 5-core cable 2 1 3 5 4 View of plug contacts Cable wires colour-coded page 6 MAN-SD 03/04

8. Function Keys For the selection of menu options, the following functions keys are available: Next Menu Option Previous Menu Option P Press once to Switch-on P Press twice to Switch-off P & Exit Menu Adjustment and Function: P & Value-adjustment upwards Value-adjustment downwards Enter value and jump to next Menu Option Reject input, Return to Menu Option 9. Adjustments Possible adjustments of the device: 1. Zero point 2. Password (factory pre-set: 0005) 3. Peak value memory (option) 4. Relay and hysteresis (option) (factory pre-set: switching point on 50% of measuring range) Factory pre-sets: 1. Battery symbol on: voltage under 7 V 2. Switch-off delay (default: 0 = inactive) 3. Sampling rate/dampening (default: 5 measurements per second) 4. Analogue output (linear) within measuring range (option) MAN-SD 03/04 page 7

10. Control Functions 10.1. Standard version MAN-SD10... and unit with analogue output MAN-SD30... P 1xP = Unit Switch on LCD Display 1234 P 1xP = Unit Switch off Password input P A S S P 0 0 0 0 Password & set on 0005 (factory setting) Cancel P Access to further Menu Options Automatic zero-point setting Z E R O P S E t On confirmation, automatic (zero) & P zero-point adjustment succeeds Cancel Change password P S E t P 4 7 1 1 Last setting (example) & Password change Cancel P Return to Display page 8 MAN-SD 03/04

10.2. Unit with peak value memory MAN-SD1S... and unit with peak value memory + analogue output MAN-SD3S... P 1xP = Unit Switched-on LCD-display Resetting 1234 P Peak value memory 1xP = Unit switched-off Peak value memory P d u P o F F Last Setting m A x Register max. value m I n Register min. value o F F Peak value memory Off & Select Cancel P Confirm selection and goto next Menu Option Password input P A S S P 0 0 0 0 Password & Set on 0005 (Factory setting) Cancel P Access to further Menu Options Automatic zero-point setting (zero) Z E R O P S E t On confirmation, automatic & P zero-point setting succeeds Cancel Change password P S E t P 4 7 1 1 Last setting (example) & Password change Cancel P Return to Display If the peak value memory is activated, the peak value can be reset by pressing the left arrow key. Note: with the switch-off of the device the peak value memory is reset. MAN-SD 03/04 page 9

10.3. Unit with switching output MAN-SD20... LCD Display 1234 P 1xP = Unit Switched-off Password input P A S S P 0 0 0 0 Password & Set on 0005 (factory setting) Cancel P Access to further Menu Options Relay set point on rising pressure r E f P 0 6. 5 0 Last switching point setting & Set sw. point on 07.50 (example) Cancel P Relay set point on falling pressure r E b P 0 6. 4 0 Last return switching point setting & Set return sw. point on 06.30 Cancel P (example) Automatic zero-point adjustment (zero) Z E R O P S E t On confirmation, automatic & P zero-point setting succeeds Cancel Change Password P S E t P 4 7 1 1 Last setting (example) & Password change Cancel P Return to Display page 10 MAN-SD 03/04

10.4. Unit with switching output + peak value memory MAN-SD2S... LDC Display P 1xP = Unit Switched-on Resetting 1234 P Peak value memory 1xP = Unit Switched-off Peak value memory P d u P o F F Last setting m A x Register max. value m I n Register min. value o F F Peak value memory Off & Select Cancel P Confirm selection and go to next Menu Option Password input P A S S P 0 0 0 0 Password & Set on 0005 (factory setting) Cancel P Access to further Menu Options Relay set point on rising pressure r E f P 0 6. 5 0 Last switching point setting & Set sw. point on 07.50 (example) Cancel P Relay set point on falling pressure r E b P 0 6. 4 0 Last return switching point setting & Set return sw. point on 06.30 (example) Cancel P Automatic zero-point adjustment (zero) Z E R O P S E t On confirmation, automatic & P zero-point setting succeeds Change password P S E t P 4 7 1 1 Last setting (example) Return to Display & Password change Cancel P If the peak value memory is activated, the peak value can be reset by pressing the left arrow key. Note: with the switch-off of the device the peak value memory is reset. MAN-SD 03/04 page 11

11. Maintenance In case, the medium to be measured is not polluted, the unit is maintenance-free. 12. Technical Information Nominal size: 74 mm Accuracy class 0,5 % Display: 4-digit LCD; digit height 12,7 mm Measuring range: -1...0, 0...1, 0...1.6, 0...2.5, 0...4, 0...6, 0...10, 0...16, 0...25, 0...40, 0...60, 0...100, 0...160, 0...250, 0...400 bar Overload range: 3 x P N (up to 40 bar) 2 x P N (60 to 160 bar) 1,5 x P N (from 250 bar) Power supply: 9 V DC (block battery, IEC 6 LR 01) Service-life at conversion rate 5/s: 5000 h (block battery 600mAh), 10000 h (Lithium block battery 1200 mah) Conversion rate: 5 per sec. (standard) (1 to 10 per sec. factory-adjustable) Automatic switch-off times: (auto off) 2... 90 min, only factory-adjustable (not recommended with analogue or switching output), 0 = inactive Zero point correction: ± 25 % Parts in contact with medium: st. steel 1.4571, ceramic, NBR (Buna-N) Connection: G ¼ A (other connection on request) Medium temperature: -30...+85 C Ambient temperature: 0...+60 C Storage temperature: -30...+80 C Permissible relative humidity: <90%, not condensing Protection cat.: IP 65 Limit-value relay (Option): N/O, bistable adjustable setpoint and hysteresis Max. switching power: 30 V AC/DC, 2 A (for relay output) Analogue output (Option): 0-2 V DC Load: 100 kω Electrical connection M 12 x 1 plug DIN (female connector as accessorie available) Total cable length: max. 3 metres Peak value memory (option): MIN or MAX value, resetting via keypad page 12 MAN-SD 03/04

13. Order Codes MAN-SD 1 0 C315 0 Output without... Relay/N/O contact... Analogue output... Peak value memory without... with... 1 2 3 0 S Measuring range code -1 to 0 bar... 0 to 1 bar... 0 to 2.5 bar... 0 to 4 bar... 0 to 6 bar... 0 to 10 bar... 0 to 16 bar... 0 to 25 bar... 0 to 40 bar... 0 to 60 bar... 0 to 100 bar... 0 to 160 bar... 0 to 250 bar... 0 to 400 bar... A315 B025 B045 B055 B065 B075 B085 B095 B105 A115 A125 A135 A145 A155 Electrical connection Without... 0.5 m cable... Plug M12 x 1... 0 K S MAN-SD 03/04 page 13

14. Dimensions Optional: PG7 (LCD) Ø74 14 51 M12 x 1 24 30 Rotatable Display 355 89 2 SW 24 G1/4A 38 page 14 MAN-SD 03/04

15. Declaration of Conformance We, Kobold-Messring GmbH, Hofheim-Ts., Federal Republic of Germany, declare, that the product Digital Manometer Model: MAN-SD... complies with the standards given below: EN 50081-1.2 1994.03 Electromagnetic compatibility - Generic emission standard EN 61326-1 1998.01 EN 61010-1 1994.03 Safety requirements for electrical measurement, control, and laboratory use Also, following EWG guidelines are fulfilled: 89/336/EWG 97/23/EG PED Category I, Table 1, pipe, gas, group 1 dangerous fluids Signature: H. Peters M. Wenzel Date: 12.07.02 MAN-SD 03/04 page 15