CONTINUOUS FINE DUST MEASURING SYSTEM

Similar documents
GRIMM Aerosol Spectrometer and Dust Monitors. Measuring principle

Certificate: / 9 September 2014

New Instruments from GRIMM

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

Direct reading aerosol monitors

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Acceleration/Velocity/Displacement VIBRATION METER

Product data sheet Palas U-SMPS 1050 / 1100 / 1200

PARTICLE MEASUREMENT IN CLEAN ROOM TECHNOLOGY

PiCUS Calliper Version 3

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Ion-Chamber Survey Meter OD-02

VIBRATION METER. Instruction Manual.

ebro has expanded its range of measuring instruments in the food area even further: ebro Data Logger Family EBI 20

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

Lufft Ceilometer Series

The new 11-R (one part of the Mini WRAS) and GRIMM MINI-WRAS Andreas Jaksch. Symposium Stockholm Mai

473-SHX Dew Point Mirror

Certificate: / 29 April 2014

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

Intelligent Sensor Management for Brewing Processes

LANCOM200 PORTABLE ACID DEWPOINT TEMPERATURE MONITORING. Acid Dewpoint SO3 H2 SO4 QUALITY CUSTOMER SOLUTIONS

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

Measure and classify nanoparticles at the touch of a button. With the portable particle counter testo DiSCmini.

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

Bright Advance Corporation

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

SOP SMPS BaltimorePM supersite Version /29/01 Page 1 of 13 SMPS

CERTIFICATE of Product Conformity (QAL1 )

ADI 2040 Process Analyzer

SafeN130 Movable Apparatus for Radioactive Noble Gases Removing

UV Hound Series. Dependable High Quality Air Monitoring. Accurate Readings Within Seconds. Portable UVDOAS Multi-gas Analyzers. Multi-Gas Capability

DUST SETTLING USING A NEGATIVE IONIZATION SYSTEM

AMMS-100 Atmospheric Metal Monitoring System

Analog - Digital multimeters

Product data sheet Palas Nanoparticle measurement system DEMC 2000

RADIATION-METER TM-91/TM-92

4 - Way Acceptance Low Maintenance Easy Installation Re - Programmable Flash ROM Auto Self -Adjusting Sensor System

Lufft MARWIS-UMB Mobile Advanced Road Weather Information Sensor

Kjeltec 2300 Analyzer Unit

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

St art. rp m. Km /h 1: : : : : : : : : : : : :5 2.5.

O P E R A T I N G M A N U A L

Mercury Stack Monitor SM-4

Comprehensive Measurement of Atmospheric Aerosols with a Wide Range Aerosol Spectrometer

INFRARED THERMOMETER TM0819

All-in-one or BOX industrial PC for autonomous or distributed applications

Development of standard calibration equipment for the rain gauges

SVH with HYDROVAR (HVL range)

TÜV RHEINLAND ENERGY GMBH ADDENDUM

State Unitary Enterprise Production Amalgamation Novosibirsk Instrument-Making Plant PN-6K. Servise Manual

Edgetech Instruments Inc.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

CERTIFICATE of Product Conformity (QAL1 )

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

Instruction Manual SEFRAM Thermal Camera

Data Sheet / Instructions. Dewpoint MeterO

SL CONTENT Page No 1 Devices Used 3

Vet Photometer DP 700 Operating Manual. Version V5.9

Lufft MARWIS-UMB Mobil Advanced Road Weather Information Sensor

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

HELLA AGLAIA MOBILE VISION GMBH

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

566/568. Infrared Thermometers. Getting Started

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser

SwemaMan 7 Operating instructions vers 1.13 MB_CW

FAVIMAT (AI)ROBOT2 FAVIGRAPH. Automatic Single-Fibre Testers

DiSCmini. Handheld diffusion size classifier for nanoparticle measurement.

FSUE PA Novosibirsk. PO3-9x24, PO3-9x24-1. Instruction manual

One-hand ph/temperature measuring instrument

Lufft MARWIS-UMB Mobil Advanced Road Weather Information Sensor

ELECTROSTATIC CLASSIFIER MODEL 3082

IDENTIFICATION STS400

Performance Measurements for Mechanical Air Handling Systems

Evaluation copy. Ground Temperature Measurements. computer OBJECTIVES MATERIALS PRE-LAB QUESTIONS

MODULE 4.3 Atmospheric analysis of particulates

Circular Motion and Centripetal Force

Drive electronics pq12

Certificate: / 30. April 2015

M E E T I n s t r u m e n t s G.m.b.H.

E THERMADATA LOGGER Humidity & temperature recording meter

PYCKO SCIENTIFIC LIMITED

EAS 535 Laboratory Exercise Weather Station Setup and Verification

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

ISEmax CAM40/CAS40. Technical Information

Minimum (-31) every 10 s -35 (-31)

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Differential Mobility Particle Sizer (Aerosol measurements)

Transcription:

CONTINUOUS FINE DUST MEASURING SYSTEM PM 10 - PM 2,5 - PM 1 Particle count distribution DustMonit ENGINEERING SRL Via Paolo Diacono, 1-20133 Milano (MI) - ITALIA Tel ++39.02.26684830 - E-mail : info@conteng.it Sito WEB : www.conteng.it

CONTINUOUS FINE DUST MEASURING SYSTEM PM10 - PM2.5 - PM1 Particle count distribution DustMonit The dust monitoring unit DustMonit is a complete system for continuous monitoring of particulate concentration in the air. The system consists of the following elements: 1. Inox housing (IP65) 2. Heated probe 3. Dust spectrometer 4. Local PC for management and storage of the measured values 5. Software for unit control This measuring system has been designed for making reliable continuous measurements without the presence of operators. This unit can be used in air pollution monitoring networks, in mobile laboratories, in places you need in a particular time a particulate concentration measurement. The methodology used by DustMonit for detecting particles in the air and for classifying them depending on their dimensions is Laser Scattering. This instrument give you the following possibilities: Measuring in real time and simultaneously the dust concentrations expressed as PM10 - PM2.5 - PM1 without utilizing external impactors. Measuring in real time and simultaneously the dust concentrations expressed as (as described in EN 481) without utilizing external impactors. Measuring in real time and simultaneously the numbers and distribution of particles in 15 dimensional classes. MAIN FEATURES Very reliable Low maintenance Long term calibration stability Insensitiveness to vibrations No radioactive source No need for shelter

Fine dust measuring methodology PM10 - PM2,5 PM1 Particle count distribution for Laser-Scattering instruments All the above concentration are measured in real time and simultaneously A constant flow pump draws air in through a radial symmetric probe and pushes fit finto a cell where each particle is hit with a laser. The energy reflected by each particle, proportional to its dimension, is measured by a high-velocity photodiode which generates counting signals as well as dimensional ones. The system software equates these values with volume unit and sends the final results via a serial RS232 to the standard engineering unit.

SPECIFICATIONS Measurement method : Laser-scattering Measurements : PM10 - PM2.5 - PM1 Particle count distribution in 15 dimensional classes (>0,30µm>0,40µm>0,50µm>0,60µm>0,70µm >0,85µm>1,00µm>1,50µm>2,00µm>2,50µm >3,00µm>4,00µm>5,00µm>7,50µm>10,0µm). Measuring range : 1 10,000µg/m 3 Sample flow Output Power supply : 1l/min : RS232 : 220V 50Hz 40W Temperature range : -10 40 C Size Weight : 50 x 40 x 20 cm : 15Kg CONTROL SYSTEM CHARACTERISTICS The control system of the unit is made with an incorporated PC menaging the instrument, storing the measurements and displaing the measurements. SOFTWARE CHARACTERISTICS A simple program allows you to set manually all measuring parameters. Dust monitor controls : Analisys Start/Stop Measurement time set Heating probe set Average On/Off COM port setting Data presentation : Real time PM10 measurement Real time PM2.5 measurement Real time PM1 measurement Real time Inhalable measurement Real time Thoracic measurement Real time Respirable measurement Real time particles count and classification in 8 or 15 dimensional classes Service data (sample flow, sample temperature and humidity and optional alarm indication) All results are stored in a SDHC card (supplied with the PC) in txt format, ready to be imported in the most common data processing software. If there is a voltage drop the instrument continues to work for two hours powered by internal rechargeable battery.

DustMonit Applications The technical characteristics of DustMonit provide this instrument with many interesting applications. Laser scattering allows immediate and continuous measurement of fine particles present in the air both with respect to their number, their dimensions and their concentration in µg/m 3. The management software installed on the PC provided, manages the measurement system, presents the relative values in real time and saves them `on adequate support for successive processing. This equipment is used mainly for: Immediate measurement of the concentration of dusts present in a specific location both urban and industrial. Valuating the environmental safety degree with respect to the particulate in a working area. Particulate measuring equipment in air pollution monitoring networks. Use on moving vehicles such as mobile laboratories, trains, etc.

EXAMPLE OF THE PRESENTATION OF THE RESULTS Air pollution expressed as PM 10 PM 2,5 PM 1 Air pollution expressed as Granulometric classification of atmospheric dust