Organ doses determined using a RANDO phantom for different radionuclide depositions and photon energies

Similar documents
OSL in Household Salt (NaCl) for Environmental, Occupational and Medical Dosimetry

Chapter 2 Dose Quantities and Units for Radiation Protection

Radioactivity in the Risø District July-December 2013

Radioactivity in the Risø District January-June 2014

COMPARISON OF THERMAL HAND MODELS AND MEASUREMENT SYSTEMS

DOSE CONVERSION FACTORS. David C. Kocher and Keith F. Eckerman Health and Safety Research Division Oak Ridge National Laboratory

11/23/2014 RADIATION AND DOSE MEASUREMENTS. Units of Radioactivity

Specific Accreditation Criteria Calibration ISO/IEC Annex. Ionising radiation measurements

Resistivity imaging for mapping of quick clays

Resistivity survey at Stora Uppåkra, Sweden

Volume 1 No. 4, October 2011 ISSN International Journal of Science and Technology IJST Journal. All rights reserved

Analytical Studies of the Influence of Regional Groundwater Flow by on the Performance of Borehole Heat Exchangers

Transmuted distributions and extrema of random number of variables

Aalborg Universitet. Lecture 14 - Introduction to experimental work Kramer, Morten Mejlhede. Publication date: 2015

Sound absorption properties of a perforated plate and membrane ceiling element Nilsson, Anders C.; Rasmussen, Birgit

Dosimetry. Sanja Dolanski Babić May, 2018.

A beam theory fracture mechanics approach for strength analysis of beams with a hole

Measurements of the angular distribution of diffuse irradiance

Organ and effective dose rate coefficients for submersion exposure in occupational settings

Numerical modeling of the conduction and radiation heating in precision glass moulding

Embankment dam seepage assessment by resistivity monitoring

Exposure Buildup Factors for Heavy Metal Oxide Glass: A Radiation Shield

Laboratoire National Henri Becquerel (CEA/LIST/LNHB), France (2) ENEA-Radiation Protection Institute, Bologna, Italy (3)

Current and Recent ICRU Activities in Radiation Protection Dosimetry and Measurements

CHARACTERIZATION OF A RADIATION DETECTOR FOR AIRCRAFT MEASUREMENTS

Activities of the International Commission on Radiological Protection

Aalborg Universitet. Comparison between Different Air Distribution Systems Nielsen, Peter Vilhelm. Publication date: 2006

Quantities and Units for Use in Radiation Protection

Akira Endo ICRP Committee 2 & ICRU Report Committee 26 Japan Atomic Energy Agency

Gy can be used for any type of radiation. Gy does not describe the biological effects of the different radiations.

Sorption isotherms for textile fabrics and foam used in the indoor environment

Geoelectrical and IP Imaging Used for Pre-investigation at a Tunnel Project. Danielsen, Berit Ensted; Arver, Henrik; Karlsson, T; Dahlin, Torleif

Lidar calibration What s the problem?

Optimal acid digestion for multi-element analysis of different waste matrices

ISO INTERNATIONAL STANDARD

City University of Hong Kong

CONSIDERATION ON THE H p(10) AND H*(10) SECONDARY STANDARD CHAMBER CHARACTERISTICS

Modelling Salmonella transfer during grinding of meat

Lattice Boltzmann Modeling From the Macro- to the Microscale - An Approximation to the Porous Media in Fuel Cells -

Technical basis of occupational dosimetrygeneral

INTERNAL RADIATION DOSIMETRY

The dipole moment of a wall-charged void in a bulk dielectric

Image quality assessment. Question: which is a better image? Answer: what are you trying to do?

Fluence-to-Dose Conversion Coefficients for Muons and Pions Calculated Based on ICRP Publication 103 Using the PHITS Code

Validation of Boundary Layer Winds from WRF Mesoscale Forecasts over Denmark

Reducing Uncertainty of Near-shore wind resource Estimates (RUNE) using wind lidars and mesoscale models

Aalborg Universitet. Publication date: Document Version Publisher's PDF, also known as Version of record

Aalborg Universitet. Land-use modelling by cellular automata Hansen, Henning Sten. Published in: NORDGI : Nordic Geographic Information

Radiometric Measurements of Environmental Radioactivity Beta Counting, Alpha and Gamma Spectrometry

ICRP Symposium on the International System of Radiological Protection

Unknown input observer based scheme for detecting faults in a wind turbine converter Odgaard, Peter Fogh; Stoustrup, Jakob

The M/G/1 FIFO queue with several customer classes

Radioactivity. Lecture 7 Dosimetry and Exposure Limits

Determining the Need For External Radiation Monitoring at FUSRAP Projects Using Soil Characterization Data. Todd Davidson

Prediction of airfoil performance at high Reynolds numbers.

A numerical study of vortex-induced vibrations (viv) in an elastic cantilever

An Equivalent Source Method for Modelling the Lithospheric Magnetic Field Using Satellite and Airborne Magnetic Data

A note on non-periodic tilings of the plane

Aalborg Universitet. Published in: Proceedings of Roomvent Publication date: 2007

Multi (building)physics modeling

Graphs with given diameter maximizing the spectral radius van Dam, Edwin

Geophysical techniques for investigating shallow and deep landslides: results in the framework of PREVIEW project (FP6 UE)

The structure of a nucleolytic ribozyme that employs a catalytic metal ion Liu, Yijin; Wilson, Timothy; Lilley, David

Citation (APA): Holm, E., Frøsig, L., & Sidhu, R. (Eds.) (2006). Theory of sampling. (NKS-122).

Diffusion of sulfuric acid in protective organic coatings

Implementing the ISO Reference Radiations at a Brazilian Calibration Laboratory

Dosimetry of ionizing radiation

Characterization of the Airflow from a Bottom Hung Window under Natural Ventilation

GIS Readiness Survey 2014 Schrøder, Anne Lise; Hvingel, Line Træholt; Hansen, Henning Sten; Skovdal, Jesper Høi

Importance of uncertainties in dose assessment to prove compliance with radiation protection standards

Assessment of Radiation Dose from Radioactive Waste in Bangladesh and Probable Impact on Health

Document Version Publisher s PDF, also known as Version of Record (includes final page, issue and volume numbers)

Multiple Scenario Inversion of Reflection Seismic Prestack Data

On the Einstein-Stern model of rotational heat capacities

Secondary Neutron Dose Measurement for Proton Line Scanning Therapy

Radiation protection in the endosuite and the importance of correct use of shields

1. RADIOACTIVITY AND RADIATION PROTECTION

RPR 29 CYCLOTRON RADIOCHEMISTRY LABORATORY

Uncertainty and detection limit in decontamination measurements of gamma emitting radio nuclides in unshielded environments Tom Koivuhuhta

Commissioning of the Beta Secondary Standard (BSS2)

A Procedure for Classification of Cup-Anemometers

Application of the MCNPX-McStas interface for shielding calculations and guide design at ESS

Application of joint inversion and fuzzy c-means cluster analysis for road preinvestigations

The colpitts oscillator family

Accelerating interior point methods with GPUs for smart grid systems

Ionization Chamber. Pocket dosimeter

Determination of packaging induced 3D stress utilizing a piezocoefficient mapping device

Citation for published version (APA): Burcharth, H. F. (1988). Stress Analysis. Aalborg: Department of Civil Engineering, Aalborg University.

Neutronics calculations for the ITER Collective Thomson Scattering Diagnostics

Matrix representation of a Neural Network

Ringhals AB. Routines for whole body counting at Ringhals NPP

Determination of Ambient Dose Equivalent at INFLPR 7 MeV Linear Accelerator

Realtime 3D stress measurement in curing epoxy packaging

Benchmark of Femlab, Fluent and Ansys

Impact of the interfaces for wind and wave modeling - interpretation using COAWST, SAR and point measurements

A Note on Powers in Finite Fields

Aalborg Universitet. Published in: IEEE International Conference on Acoustics, Speech, and Signal Processing. Creative Commons License Unspecified

Berøringsløs optisk måling af gassammensætning ved UV og IR spektroskopi

COMPARISON OF PERSONNEL RADIATION MONITORING DOSIMETERS DESIGNED FOR MEDICAL FIELD

Room Allocation Optimisation at the Technical University of Denmark

Transcription:

Organ doses determined using a RANDO phantom for different radionuclide depositions and photon energies Hörnlund, Mikael; Bernhardsson, Christian Published in: Medical Physics in the Baltic States Published: 2013-01-01 Document Version Publisher's PDF, also known as Version of record Link to publication Citation for published version (APA): Hörnlund, M., & Bernhardsson, C. (2013). Organ doses determined using a RANDO phantom for different radionuclide depositions and photon energies. In D. Adliene (Ed.), Medical Physics in the Baltic States: Proceedings of the 11th International Conference on Medical Physics (pp. 103-105). Kaunas University Of Technology Press. General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. Users may download and print one copy of any publication from the public portal for the purpose of private study or research. You may not further distribute the material or use it for any profit-making activity or commercial gain You may freely distribute the URL identifying the publication in the public portal L UNDUNI VERS I TY PO Box117 22100L und +46462220000

Take down policy If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim. Download date: 24. Sep. 2018

MEDICAL PHYSICS IN THE BALTIC STATES 11 (2013) Proceedings of International Conference Medical Physics in the Baltic States 10-12 October 2013, Kaunas, Lithuania ORGAN DOSES DETERMINED USING A RANDO PHANTOM FOR DIFFERENT RADIONUCLIDE DEPOSITIONS AND PHOTON ENERGIES Mikael HÖRNLUND, Christian BERNHARDSSON Medical Radiation Physics, Department of Clinical Sciences, Malmö, Lund University, Skåne University Hospital, SE-205 02, Malmö, Sweden Abstract: Dose conversion coefficients relating the kerma free-in-air to effective dose have been studied. In order to do so a sampling scheme encompassing all the risk organs and tissues was developed for the Alderson RANDO phantom. Preliminary results are shown for some specific organs irradiated with a point source in the laboratory. Keywords: RANDO phantom, dose conversion factors, TLD 1. Introduction The international Commission on radiological protection (ICRP) has introduced the effective dose (E) for the management of stochastic effects, i.e., in order to implement the principle of limitation 1 and the principle of optimization 2 in radiological protection [1]. The effective dose is calculated from the equivalent dose to a set of risk organs and tissues in the human body. Summation of the equivalent organ doses, multiplied by the appropriate tissue weighting factors, yields the effective dose [2]. Obviously, effective dose cannot be measured. However, by estimation of the dose distribution in the human body (due to external exposure) the risk quantity can be related to physical, measurable quantities. The coefficient relating the two quantities is called a conversion coefficient (CC) [3]. Conversion coefficients have been published by several authors e.g. [4, 5] as well as the ICRP [3]. In order to determine CCs, associated with external exposure to gamma radiation, one can either use computational methods on mathematical phantoms [6] or experimental in situ measurements with anthropomorphic phantoms [7]. As pointed out by Golikov et al. (2007), the number of experimental efforts to derive conversion coefficients is steadily exceeded by those based upon mathematical methods. One drawback in trying to perform an experiment where the goal is to derive CCs from measurements on contaminated soil is to find a proper location where experiments are allowed, either by the environment (e.g. heavily contaminated soil) or by artificially contaminating a surface. In 2011 a dedicated mobile system for dispersion of activity (financially supported by the Swedish radiation safety authority) was acquired at the Medical Radiation Physics group in Malmö. This system allows simulating surface contamination of various size and types of radionuclides in situ. The long-term aim of the present work is to determine conversion coefficients from contaminated plane quadratic surfaces, as well as for point-sources using an anthropomorphic phantom (Alderson RANDO phantom). Conversion coefficients relating the effective dose to kerma free-in-air will be investigated for a set of photon energies. As a first step to do so, an appropriate sampling scheme encompassing all the risk organs and tissues (as defined in ICRP report 103) for the widely used Alderson RANDO phantom was established and the experimental set-up was tested. Here we report on our first results from this study. 2. Material and methods The anthropomorphic Alderson RANDO phantom 3 is a commercially available, well-known and widely used phantom for obtaining dose distributions from external irradiation (Fig. 1). The phantom (male) consists of natural human skeleton enclosed in tissue-simulating plastic (mass density = 0.985 g cm-3, effective atomic number = 7.30), molded to resemble a human adult. The RANDO phantom also accounts for the lungs (Fig. 2). The lung-simulating tissue has the same effective atomic number as the tissue-simulating plastic, but a lower mass density of 0.32 g cm-3. 1 Radiation exposure due to handling of radiation must be kept as low as reasonably achievable. 2 Exposure of individuals of the public and radiation workers must not exceed the dose limits. 3 The RANDO phantom. The Phantom Laboratory. P.O. Box 511, Salem, NY 12865-0511 United States. 103

M. Hörnlund et. al. / Medical Physics in the Baltic States 11 (2013) 103-105 overlapping in sampling points, were used for the liver in order to assess the impact of the number of TLDs used on the determined (mean) organ dose. The number of dosimeters and the sampling schemes are shown in Table 1. Table 1: Organs exposed during test-irradiation. The number in parenthesis corresponds to the number of overlapping sampling points for the two sampling schemes. Organ # TLDs Sampling Scheme Liver 71 (14) Golikov and Nikitin (1989) Liver 19 (14) Scalzetti et al. (2008) Prostate 2 Scalzetti et al. (2008) Bladder 6 Scalzetti et al. (2008) Fig. 1. The Alderson RANDO Phantom (left) consisting of 36 slabs with TLD insertions. Top side of slab number 21 of the RANDO Phantom (right). White (or black) labels correspond to sampling points for organs identified to be located in the current slab. Sampling points corresponding to the part of the liver in slab 21 is encompassed by red markings. For the purpose of achieving rotational invariant exposure geometry the phantom was positioned on a table rotating with one revolution per eight seconds. A 60 Co point-source of 74.9 MBq was mounted on a chain, hanging from the roof perpendicular to the table, at a distance of 1.6 m from the center of rotation (Fig. 3). Fig. 2. Anterior-posterior (AP) view of the Alderson RANDO Phantom (left) (head not included). Slab 15 of the RANDO phantom (upper right). Slab 28 of the RANDO phantom (lower right). Approximate location of slab 15 and 28 are marked out on the AP image (left image). The male RANDO phantom consists of 36 slabs, each with a thickness of 2.5 cm, except for the lower pelvic section which is 9 cm thick. Each section contains a grid of holes, separated by 30 mm and 5 mm in diameter, where thermoluminescent (TL) dosimeters may be inserted (see Fig. 1). The male RANDO phantom corresponds to a complete body of 175 cm and 73.5 kg (a female version of the RANDO phantom is also available, but this will not be included in the present work). The sampling points and the mass fractions for the various risk organs and tissues in the Alderson RANDO phantom were determined with the help of clinical expertise, data from the literature and CTimages of the phantom In order to evaluate the compiled sampling scheme, a test irradiation of the RANDO phantom with TLDs inserted into a limited number of organs was undertaken in the laboratory. For this purpose, 84 TL-dosimeters were annealed at 240 C for 10 min, thereafter rapidly cooled and inserted into the organ sampling points corresponding to the urinary bladder, liver and prostate, respectively. Two sampling-schemes, partially Fig. 3. Experimental setup during irradiation. 1: 60 Co-source mounted on a chain; 2: distance between 60 Co-source and personal dosimeter (1.5 m); 3: distance between 60 Co-source and the center of rotation. By positioning a dose rate meter at the center of rotation, the dose rate was determined to 14 μsv h -1, at the height of the phantoms chest. Irradiation was carried out during 48 hours and then the source was removed and the TLDs retrieved. Mean organ doses were calculated as the mean from the TL-response of each dosimeter in the organ. 3. Results and discussion A sampling scheme containing the mass fractions and sampling positions for risk organs and tissues, as defined by the ICRP (2007), has been compiled for the male Alderson RANDO phantom [8]. The mass of the organs and tissues used as the basis for the sampling scheme agree within ±4% with the reference values published by the ICRP, Publication 89 (2002), except for the salivary glands, eyes and prostate, for which the discrepancy in mass is 24%, 6% and 7%, respectively. Other sampling schemes of the RANDO phantom have been compiled by e.g. [9-11]. However, none of the authors have compiled a sampling scheme with sufficient information to allow the calculation of effective dose, i.e. sampling positions and mass fractions for some important risk organs have not been included. Most notably, the sampling positions for the 104

M. Hörnlund et. al. / Medical Physics in the Baltic States 11 (2013) 103-105 red bone marrow (RBM) have not been included. An attempt to provide this information has been performed in the present work. However, the precision and the accuracy of the sampling scheme have not yet been fully evaluated in the present work. Field measurements and comparisons with published data on the dose distribution in the RANDO phantom is required in order to assess the usefulness of the sampling scheme. The results from the first indoor experiments on the RANDO phantom are presented in Tables 2 and 3. The experimental setup was as in Fig. 3 using a 60 Co pointsource. Table 2. Experimental setup during the laboratory irradiation. Isotope Time (h) Point source activity (MBq) Ambient dose rate, H * (10) Personal dose equivalent, Hp(10) 60 Co 48 74.8 762 480 Table 3. Mean organ dose and calculated conversion coefficients for the RANDO phantom when irradiated from a 74.8 MBq 60 Co point-source at a distance of 1.5 m during 48 h. Organ Mean organ dose, D (μgy) D/H * (10) (Gy Sv -1 ) D/H p(10) (Gy Sv -1 ) RBM 310 0.41 0.65 Liver 350 0.46 0.73 Bladder 313 0.41 0.65 Prostate 302 0.40 0.63 The conversion coefficients in Table 3 relate the ambient dose and personal dose, respectively, to the mean organ dose for four different risk organs (RBM, liver, bladder and prostate 4 ). Conversion coefficients relating protection quantities to operational quantities are not published in ICRP 74 (1996). However, the operational quantities are indirectly related to the mean organ dose by conversion coefficients between the operational quantities and kerma free-in-air. The reason for presenting the CCs in terms of a protection quantity through an operational quantity is that most dosemeters and radiation monitoring devices are calibrated in terms of the operational quantities rather than kerma free-inair. Thus, CCs as given in Table 3, would likely facilitate the usage of conversion coefficients in radiation protection in practice. Unfortunately, a direct comparison with the values published by ICRU could not be done since kerma was not measured during this experiment. Conversion coefficients resulting from combining the calculated kerma with the mean organ dose in Table 3 is numerically equal to the values presented in the column for D/H p (10). These values are approximately 25% larger than the corresponding CCs published by the ICRP (1996). No obvious reason for this discrepancy has been found by the author. The numerical values for the conversion coefficients, in a given column, in Table 3 have an absolute difference lower than 15% from each other. No direct comparison with the literature can be done since CCs are not usually published as in Table 3. However, the absolute difference is larger than the corresponding absolute difference for the CCs in terms of mean organ dose to kerma free-in-air, for the same 4 Part of the remainder. organs, as published by the ICRU, Report 57 (1998). For 60 Co-photons the CCs differs no more than 5%. 4. Conclusions A complete sampling scheme with mass fractions and positions of the risk organs for the Alderson RANDO phantom is now available. With this sampling scheme it will be possible to calculate the organ doses or effective dose to the organs at risk as defined by the ICRP (2007). These are the first results from this project on conversion coefficients which will be extended to cover all organs and tissues of the RANDO phantom. Different point sources with various gamma energies will be investigated in the laboratory. Finally, conversion coefficients for different homogenously dispersed radioactive surfaces will be determined in situ using a dedicated dispersion device. Acknowledgments This project was financially supported by the Swedish Radiation Safety Authority (SSM). 5. References 1. Menzel H-G. and Harrison J. Effective dose: a radiation protection quantity. Annals of the ICRP, 2012;41(3-4):117-123. 2. International Commission on Radiological Protection. The 2007 Recommendations of the International Commission on Radiological Protection. 2007, ICRP Publication 103. Ann. ICRP 37 (2-4), p. 1-332. 3. International Commission on Radiological Protection. Conversion Coefficients for use in Radiological Protection against External Radiation. 1996, ICRP Publication 74. Ann. ICRP 26 (3-4), p. 1-205. 4. Eckerman K. and Ryman J. External Exposure to Radionuclides in Air, Water, and Soil. 1993, Federal Guidance Report No. 12, U.S. Environmental Protection Agency, Washington, D.C. 5. Lee J.S., Dong S.L. and Wu T.H. Estimation of organ dose equivalents from residents of radiation-contaminated buildings with Rando phantom measurements. Applied Radiation and Isotopes 1999; 50(5): 867-873. 6. Jacob P., Paretzke H., Rosenbaum H. and Zankl M. Effective dose equivalents for photon exposures from plane sources on the ground. Radiation Protection Dosimetry 1986; 14(4): 299-310. 7. Golikov V., Wallström E., Wöhni T., Tanaka K., Endo S. and Hoshi M. Evaluation of conversion coefficients from measurable to risk quantities for external exposure over contaminated soil by use of physical human phantoms. Radiation and Environmental Biophysics 2007; 46(4):375-382 8. Hörnlund M. Estimation of dose conversion factors conversion factors from measurable to risk related quantities [MSc thesis]. Malmö: Göteborg University; 2013 9. Golikov V. and Nikitin V. Estimation of the mean organ doses and the effective dose equivalent from Rando phantom measurements. Health Physics 1989; 56(1):111-115. 10. Huda W. and Sandison G. Estimation of mean organ doses in diagnostic radiology from Rando phantom measurements. Health Physics 1984; 47(3): 463-467. 11. Scalzetti E., Huda W., Bhatt S. and Ogden, K. A method to obtain mean organ doses in a Rando phantom. Health Physics 2008; 95(2):241-244. 105