Voyager-DE STR Biospectrometry Workstation Manufactured by PerSeptive Biosystems

Similar documents
MASS SPECTROMETRY. Topics

Purdue-UAB Botanicals Center for Age- Related Disease

1. Prepare the MALDI sample plate by spotting an angiotensin standard and the test sample(s).

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

LECTURE-13. Peptide Mass Fingerprinting HANDOUT. Mass spectrometry is an indispensable tool for qualitative and quantitative analysis of

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

Mass spectrometry gas phase transfer and instrumentation

Peptide Mass Fingerprinting (PMF) Data Acquisition Using the Voyager DE- PRO Database Search with PMF Data using Ms-Fit

Operating Instructions

CHAPTER A2 LASER DESORPTION IONIZATION AND MALDI

Lecture 8: Mass Spectrometry

Lecture 8: Mass Spectrometry

Olumide Adebolu. Chromatographic Fidelity and Matrix /Analyte Solubility in Complex Polymer Systems using HPLC-MALD/I TOF MS

Cryodetectors in Life Science Mass Spectrometry. Damian Twerenbold

Chapter 14. Molar Mass Distribution.

TANDEM MASS SPECTROSCOPY

Macromolecular Chemistry

Lecture 15: Introduction to mass spectrometry-i

Other Methods for Generating Ions 1. MALDI matrix assisted laser desorption ionization MS 2. Spray ionization techniques 3. Fast atom bombardment 4.

CHROMATOGRAPHY AND MASS SPECTROMETER

Materials: Micropipettes (2-20 µl range pipette, µl range, µl range), tips, test tubes with color dye, well plates

and Environmental Science Centre

Mass spectrometry of proteins, peptides and other analytes: principles and principal methods. Matt Renfrow January 11, 2008

Laser desorption/ionization on the layer of graphene nanoparticles coupled with mass spectrometry for characterization of polymer

Harris: Quantitative Chemical Analysis, Eight Edition

Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. H i

M M e M M H M M H. Ion Sources

Mass spectrometry.

MALDI Calibration. Mass Control List

Introduction to the Q Trap LC/MS/MS System

MSP BigAnchor Targets BC

Ionization Methods in Mass Spectrometry at the SCS Mass Spectrometry Laboratory

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Mass spectrometry: forming ions, to identifying proteins and their modifications Stephen Barnes, PhD

Mass spectrometry: forming ions, to identifying proteins and their modifications Stephen Barnes, PhD

CHAPTER D4 ORTHOGONAL TIME OF FLIGHT OPTICS

BST 226 Statistical Methods for Bioinformatics David M. Rocke. January 22, 2014 BST 226 Statistical Methods for Bioinformatics 1

Fourier Transform Infrared Spectroscopy (Perkin Elmer - Spectrum One)

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Experimental Design and Data Collection

Mass Spectrometry in MCAL

Ch 13. Basics of Mass Spectrometry (I) : Principles & Ionization Sources

Supporting Information. Experimental details

Chromatography & instrumentation in Organic Chemistry

IDENTIFICATION TESTS FOR DURACOR TABLETS

Spectrophotometry Materials

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Multi-step Conformation Selection in Amyloid Assembly

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Soil Cation Analysis Using High-Performance Capillary Zone Electrophoresis Last Modified: October 20, 2006

Introduction to Fourier Transform Infrared Spectroscopy

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Protein Structure Analysis and Verification. Course S Basics for Biosystems of the Cell exercise work. Maija Nevala, BIO, 67485U 16.1.

Supplementary information

Qualitative Organic Analysis CH 351 Mass Spectrometry

Effective desalting and concentration of in-gel digest samples with Vivapure C18 Micro spin columns prior to MALDI-TOF analysis.

MALDI-TOF: a powerful tool for the analysis of biomolecules and large organic molecules

DAY LABORATORY EXERCISE: SPECTROSCOPY

Determination of an Equilibrium Constant

Agilent G3212 GC-APCI Source

Rate law Determination of the Crystal Violet Reaction Using the Isolation Method

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

Experiment 9. Emission Spectra. measure the emission spectrum of a source of light using the digital spectrometer.

Analysis of Polar Metabolites using Mass Spectrometry

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Physical Separations and Chromatography

Instructor s Advance Preparation

UV-Vis optical fiber assisted spectroscopy in thin films and solutions

ICP-OES DETERMINATION OF IRON. Introduction:

Introduction to Fourier Transform Infrared Spectroscopy

Lecture 22 Ion Beam Techniques

2,5-Dihydroxybenzoic. Figure 6.1. Chemical structures of several common matrix compounds.

Photoluminescence Spectrometer (FLS980)

MIXTURES, COMPOUNDS, & SOLUTIONS

electrons out of, or ionize, material in their paths as they pass. Such radiation is known as

1) In what pressure range are mass spectrometers normally operated?

Mass Spectrometry for Chemists and Biochemists

Photoelectron Spectroscopy using High Order Harmonic Generation

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR

Confocal Microscopy Imaging of Single Emitter Fluorescence and Hanbury Brown and Twiss Photon Antibunching Setup

Ionization Techniques Part IV

MS/MS .LQGVRI0606([SHULPHQWV

Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry

Electrospray Ion Trap Mass Spectrometry. Introduction

OPSE FINAL EXAM Fall 2016 YOU MUST SHOW YOUR WORK. ANSWERS THAT ARE NOT JUSTIFIED WILL BE GIVEN ZERO CREDIT.

ICP-MS. High Resolution ICP-MS.

Semester One Test Review

Supporting Information

often display a deep green color due to where the SPR occurs (i.e., the wavelength of light that interacts with this specific morphology).

Exercise 2-2. Titration of a Strong Acid EXERCISE OBJECTIVES

Questions on Electric Fields

The Power of LC MALDI: Identification of Proteins by LC MALDI MS/MS Using the Applied Biosystems 4700 Proteomics Analyzer with TOF/TOF Optics

Calibrating Thermo Exactive with the Direct Analysis in Real Time (DART) Ambient Ionization Source (Protocol Adapted from US FDA FCC)

Chem 524 Lecture Notes CD (Section 18) update 2011

Mass Spectrometry. General Principles

Atomic Spectra. d sin θ = mλ (1)

Construction of a matrix assisted laser desorption/ionization time-of-flight mass spectrometer

EXPERIMENT: LIMITING REAGENT. NOTE: Students should have moles of reactants in DATASHEET converted into masses in grams prior to the lab period.

Transcription:

Voyager-DE STR Biospectrometry Workstation Manufactured by PerSeptive Biosystems General Description The Voyager-DE STR Biospectrometry Workstation includes upgraded electronics, a 3-meter flight path, and improved ion optics. It delivers high sensitivity and resolution, as well as, unparalleled mass accuracy, giving you the tools you need to characterize complex mixtures and determine molecular weight on sub-picomole samples. The Voyager-DE STR Biospectrometry Workstation continues to lead the industry as the ultimate research machine for biomolecule characterization. Application Areas Peptide Confirmation Oligonucleotide Analysis Peptide Sequencing by MS/MS Protein Analysis C-terminal sequencing Oligonucleotide sequencing Post transnational Modifications Glycolysation, Phosphorylation, Sulfation Carbohydrate Analysis Small Molecules Sample Preparation MALDI is the mechanism used to ionize the sample. The sample is embedded in a low molecular weight, UV absorbing matrix that enhances sample ionization. When a laser beam hits the matrix, it appears to transfer enough energy to the sample to form molecular ions. The matrix is present in vast excess of sample and therefore isolates individual sample molecules. It is important that contaminants such as buffers, salts and Selecting a matrix The matrix must be capable of forming a fine crystalline solid during codeposition with the analyte. The matrix molecules must have a high absorptivity for the laser radiation The following table lists the concentrations of some matrices that can be used in certain applications.

2,5-dihydroxybenzoic acid (2,5-DHB) MW 154.03 Da Sinapinic Acid MW 224.07 Da Preparing Samples Matrix Application Matrix Solution Peptides, neutral or basic carbohydrates, 10 mg/ml in a solvent in which sample glycolipids, polar and nonpolar synthetic and matrix are soluble polymers, small molecules α-cyano-4-hydroxy cinnamic acid (αchca) MW 189.04 Da 3-hydroxy-picolinic acid (3-HPA) MW 139.03 Da 2,4,6-Trihydroxy acetophenone (THAP) MW 168.04 Da Dithranol MW 226.06 Da Trans-3-indoleacrylic acid (IAA) MW 123.03 Da 2-(4-hydroxyphenylazo)-benzoic acid (HABA) MW 242.07 Da 2-aminobenzoic (anthranilic) acid MW 137.05 Da Peptides and Proteins > 10,000 Da Peptides, proteins and PNAs < 10,000 Da Large oligonucleotides > 3,500 Da Small oligonucleotides < 3,500 Acidic carbohydrates, acidic glycopeptides Nonpolar synthetic polymers Nonpolar polymers Proteins Polar and nonpolar synthetic polymers Oligonucleotides (negative ions) For successful sample preparation, prepare fresh matrix as needed. Some matrices require daily preparation, while other matrices can be stored for up to one week at 4 0 C. It is important to determine the proper dilution of sample and to use clean sample plates. Properly apply sample and dry to allow for good crystallization. Good crystallization is obtained when you have small, equally sized crystals that are evenly distributed on the plate. Clumping is not desirable because this will make it difficult to analyze the sample. The following table provides concentrations of samples that contain certain compounds. 10 mg/ml in 70:30 water/acetonitrile (0.1% TFA) 10 mg/ml in 50:50 water/acetonitrile (0.1% TFA) if sample contaminated 10 mg/ml in 50:50 water/acetonitrile (0.1% TFA final conc) 50 mg/ml in 50:50 water/acetonitrile, plus 50 mg/ml diammonium citrate in water 10 mg/ml in 50:50 water/acetonitrile, plus 50 mg/ml diammonium citrate in water 10 mg/ml in tetrahydrofuran 10-1 M in solvent appropriate for sample ~1.3 mg/ml in 50:50 water/acetonitrile or in 40:40:20 water/acetonitrile/methanol ~10 mg/ml in 80:20 water/acetonitrile (20% w/w nicotinic acid can be added) Compound Peptides and proteins* Oligonucleotides Polymers Concentration 0.1 to 10 pmol/µl 10 to 100 pmol/µl 10-4 M *Some proteins, particularly glycoproteins, yield better results at concentrations up to 10 pmol/µl Sample Introduction There are two types of sample plates available: Flat sample plates where the liquid is held in place by surface tension of the sample/matrix mixture. The sample plate allows you to observe crystallization pattern and the actual sample spot is visible. Welled sample plates have the liquid held in place by an indentation in the plate. These sample plates are used in running an autosampler because the sample position is well defined. Once the sample/matrix have crystallized on the sample plate, the plate can be loaded into the mass spectrometer. Eject the sample holder Hold the sample plate vertically, with the sample surface facing to the right, and with the slanted underside of the plate facing toward the back of the instrument.

Slide the sample plate into the holder from the front until it snaps into place. The ball bearings on the holder snap into the plate. Click Load to retract the sample plate and insert it into the main source chamber. It takes a minute or two for the sample plate to reach the correct position. On the video monitor you will observe a real-time sample image (30 times magnification). Use the control stick to move over the sample plate until you find your sample. To start acquiring data press the left button on the control stick. Find a hot spot (areas of high ion intensity) by moving around the sample spot. Once you find the hot spot, stop acquiring data and restart. You will not want to move around when acquiring actual data. Mass Spectrometer Ion Sources To ionize the sample a nitrogen laser that operates at 337 nm is used. It produces a 3-nanosecond-wide pulse at up to 20 pulses per second. In delayed extraction mode, acquisition does not start until the extraction pulse is applied to the sample. (Delayed extraction is a technique where a time delay is used between the end of the ionization pulse and the start of the extraction pulse. This technique allows for all ions of the same mass to acquire the same kinetic energy. Ions of the same mass will hit the detector at the same time giving rise to sharper peaks.) The laser attenuator varies the intensity of the laser beam reaching the sample and the prism deflects the laser beam into the ion source. The ion source is a high voltage region used to accelerate ions down the time of flight tube. The sample plate is supplied with 0 to 25,000 V to accelerate the ions into the flight tube. The variable-voltage grid supplies additional voltage to fine-tune ion acceleration. The ground grid is the ground surface for formation of the potential gradient. The grounded aperture is the entrance to the flight tube. Mass Analyzer A time-of-flight (TOF) mass analyzer is used to separate the ions formed from MALDI. The light ions formed during each pulse reach the detector first. This is true because all the ions are given the same kinetic energy (½mv 2 ) from the ion acceleration region. The lightest ions, therefore, have the highest velocity while the heavier ions have a slower velocity.

Detector There are two detectors present in the Voyager-DE STR Biospectrometry Workstation. A linear detector measures ion abundance over time and sends a signal to the digitizer for conversion. A reflector detector measures ions reflected by a mirror and then sends a signal to the digitizer for conversion. The reflector filters out neutral molecules, corrects for time dispersion due to initial kinetic energy variations and provides greater mass accuracy and resolution. Sensitivity Specifications A MALDI/TOF mass spectrometer analyzes for protein molecular weights. To determine the protein molecular weight there is a tradeoff between resolution and sensitivity, for higher sensitivity there is lower resolution. For increased sensitivity analysis of smaller amounts of sample can yield a better signal. Serial dilutions of the sample before mixing with the matrix could be done to obtain a good sample to matrix ratio, as well as, decreasing any contamination present in the sample. An optimum concentration ratio between sample and matrix is important for larger molecules (>10 kda). Example Mass Spectrum MALDI mass spectrum of 15 pmol of reduced somatostatin after reaction with a five-fold molar mass excess of phmb over total cysteine. (From Watson. Introduction to Mass Spectrometry, 3 rd Edition. Lippincott-Raven Publishers, 1997.) Interviews Here are four questions asked to and answered by a biochemistry graduate student and a lab technician who use the instrument. Question: What do you use the MALDI/TOF instrument for? Student: Determination of nucleic acids by their molecular weights Lab Tech: Protein identification by determining peptide masses Question: Is it easy to use? Student: Yes, very easy to use. Lab Tech: Very user friendly. Question: What is good about the instrument:

Student: Has a large mass window. Lab Tech: Easy sample prep and the data are easily analyzed. Question: What is bad about the instrument? Student: Can t change a lot of the variables. Also you need to make sure the sample is very well desalted or else the peaks become very large. Lab Tech: Outdated oscilloscope and there are software bugs. References PerSeptive Biosystems. Voyager Biospectrometry Workstation with Delayed Extraction Technology User s Guide. PerSeptive Biosystems, Inc., 1996. Watson. Introduction to Mass Spectrometry, 3 rd Edition. Lippincott-Raven Publishers, 1997. Interviews: Date performed 10/28/02 Student: Christina Ymata Lab Tech: Lauren Wolfe