Technical Status Update on PA Lifetime Spectroscopy Experiments and Results

Similar documents
Photocopy and Use Authorization

DEVELOPMENT OF A NEW POSITRON LIFETIME SPECTROSCOPY TECHNIQUE FOR DEFECT CHARACTERIZATION IN THICK MATERIALS

Application of positrons in materials research

The intense, pulsed positron source EPOS at the Research Centre Dresden-Rossendorf

New Concept of EPOS Progress of the Mono-energetic Positron Beam (MePS) Gamma-induced Positron Spectroscopy (GiPS)

Research Center Dresden Rossendorf

Positron Annihilation Spectroscopy - A non-destructive method for material testing -

on basis of the Geant4 simulations

CHAPTER-II Experimental Techniques and Data Analysis (Positron annihilation spectroscopy)

David B. Cassidy. Department of Physics and Astronomy, University of California, Riverside, USA. Varenna, July 09

Sven Schumann. DPG Spring Meeting

EEE4106Z Radiation Interactions & Detection

Positron Annihilation Lifetime Spectroscopy (PALS)

POSITRON AND POSITRONIUM INTERACTIONS WITH CONDENSED MATTER. Paul Coleman University of Bath

ANAIS: Status and prospects

Introduction into Positron Annihilation

The EPOS System (ELBE Positron Source) at Helmholtz Centre Dresden- Rossendorf and first experiments at photovoltaic CIGS layers

Positron theoretical prediction

PRINCIPLES OF POSITRON ANNIHILATION

Identification of Getter Defects in high-energy self-implanted Silicon at Rp/2

EPOS an intense positron beam project at the Research Center Rossendorf

Positron Annihilation in Material Research

Basics and Means of Positron Annihilation

III. Energy Deposition in the Detector and Spectrum Formation

First tests of the big volume ultra low background gamma spectrometer

Investigation of the nuclear structure of 17 O at high excitation energy with five-particle transfer reactions

positron source EPOS - general concept - timing system - digital lifetime measurement

Week 7: Ch. 10 Spec. w/ Scintillation Ctrs. Photomultiplier Devices

A Liquid Argon Scintillation Veto for the GERDA Experiment

GAMMA RAY SPECTROSCOPY

DARK MATTER SEARCHES AT CANFRANC: ANAIS AND ROSEBUD: an update INTRODUCTION AND EXPERIMENTAL GOALS SUMMARY OF RECENT ACHIEVEMENTS AND EFFORTS

Nuclear Physics and Astrophysics

STRESS ANALYSIS USING BREMSSTRAHLUNG RADIATION

Feasibility of a new polarized active detector for low-energy ν

Hands on LUNA: Detector Simulations with Geant4

Dedicated Arrays: MEDEA GDR studies (E γ = MeV) Highly excited CN E*~ MeV, 4 T 8 MeV

Study of semiconductors with positrons. Outlook:

Outlook: Application of Positron Annihilation for defects investigations in thin films. Introduction to Positron Annihilation Methods

Presentation at the 10th RIBLL Collaboration Symposium, Beijing, 2017/1/7

DETECTORS. I. Charged Particle Detectors

The intense Positron Source EPOS at ELBE Radiation Source of Research Center Rossendorf

The intense positron source EPOS at Research Center Rossendorf

Positron Annihilation Spectroscopy

Final Results from the MEG Experiment and the Status of MEG-II

Absolute activity measurement

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Source induced backgrounds - Gammas

Cross-section Measurements of Relativistic Deuteron Reactions on Copper by Activation Method

PHYS 3650L - Modern Physics Laboratory

The MePS System at Helmholtz-Zentrum Dresden-Rossendorf and its special Capability for Positronium Lifetime Spectroscopy

Correlated Background measurement in Double Chooz experiment

Y2 Neutrino Physics (spring term 2017)

Particle Energy Loss in Matter

Beam Dump Experiments at JLab and SLAC

Motivation. g-spectroscopy deals with g-ray detection and is one of the most relevant methods to investigate excited states in nuclei.

Investigation of SiC by Positrons

AMoRE L.T. Measurement. Geon-Bo Kim SNU & KRISS

ASPECTS OF THE MCMASTER INTENSE POSITRON BEAM FACILITY

Development of a High Precision Axial 3-D PET for Brain Imaging

Nuclear Reactions A Z. Radioactivity, Spontaneous Decay: Nuclear Reaction, Induced Process: x + X Y + y + Q Q > 0. Exothermic Endothermic

Compact Photon Source: Update

ATHENA / AD-1. First production and detection of cold antihydrogen atoms. ATHENA Collaboration. Rolf Landua CERN

AIR FORCE INSTITUTE OF TECHNOLOGY

Structure of neutron-rich Mg isotopes explored by beta-decay of spin-polarized Na isotopes

Searching for at Jefferson Lab. Holly Szumila-Vance On behalf of the HPS, APEX, DarkLight, and BDX 2017 JLab User s Group Meeting 20 June 2017

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

Supplementary Figure 1 Comparison of single quantum emitters on two type of substrates:

Introduction to Ionizing Radiation

F. Cappella INFN - LNGS

Measurement of high energy gamma rays with large volume LaBr 3 :Ce scintillators

Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber

Going beyond the traditional nuclear shell model with the study of neutron-rich (radioactive) light nuclei

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

Alpha Decay. Decay alpha particles are monoenergetic. Nuclides with A>150 are unstable against alpha decay. E α = Q (1-4/A)

Positron-Electron Annihilation

Reaction rates in the Laboratory

in Si by means of Positron Annihilation

Detekce a spektrometrie neutronů. neutron detection and spectroscopy

Uppsala University. October 16, Dark Forces at Accelerators, Frascati, Oct π 0 decays with WASA-at-COSY. Carl-Oscar Gullström

arxiv: v1 [physics.ins-det] 29 Jun 2011

EXPERIMENTAL STUDY OF NEUTRON FIELDS PRODUCED IN PROTON REACTIONS WITH HEAVY TARGETS. Nuclear Physics Institute AS CR, Rez Czech Republic

Simulating Gamma-Ray Telescopes in Space Radiation Environments with Geant4: Detector Activation

ABSTRACT CHARACTERIZING DEFECTS IN STEEL, ALUMINUM AND COPPER BY WAY OF POSITRON ANNIHILATION LIFETIME SPECTROSCOPY. by Jason Lavaska Calloo

Development of a table top TW laser accelerator for medical imaging isotope production

Interaction of Ionizing Radiation with Matter

Oslo Cyclotron Laboratory

Positron and positronium for the GBAR experiment

Direct WIMP Detection in Double-Phase Xenon TPCs

Spectral Filtering for Improving Quality of Material Discrimination Using Dual Energy X-rays

Investigation of radiative proton-capture reactions using high-resolution g-ray spectroscopy

3. Perturbed Angular Correlation Spectroscopy

Material Science using Positron Annihilation

Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

High resolution spectroscopy of hypernuclei with γ-ray detectors

INTRODUCTION TO MEDICAL PHYSICS 1 Quiz #1 Solutions October 6, 2017

High-Resolution Gamma-Ray and Neutron Detectors For Nuclear Spectroscopy

the first prototype for a scintillating bolometer double beta decay experiment.

Michigan State University, East Lansing MI48824, USA INTRODUCTION

Transcription:

Technical Status Update on PA Lifetime Spectroscopy Experiments and Results Dustin McNulty Idaho State University mcnudust@isu.edu October 9, 2012

Technical Status Update on PA Lifetime Spectroscopy Experiments and Results Outline Introduction Theory Methods and Materials Spectrometer Optimization/Benchmarking Analysis and Results Future Work Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 1

Goals of Study Construction and optimization of a Positron Annihilation Lifetime Spectrometer Capable of distinguishing between defect and defect-free material samples Source-based experiments: Benchmarking to literature values Annealed samples (bulk/non-defect) Unannealed (defect) Accelerator-based experiments: Feasibility studies and reproducing source-based measurements Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 2

PALS Overview Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 3

22 Na Positron Source Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 4

Positron Interactions: Thermalization Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 5

Positron Interactions: Penetration Depth Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 6

Positron Interactions: Diffusion Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 7

Positron Interactions: Trapping Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 8

Positron Interactions: Annihilation Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 9

PALS Spectrometer Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 10

Energy Discrimination & Lifetime Spectrum Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 11

Experimental Setup Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 12

Scintillator Properties Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 13

PMT Specifications (Hamamatsu R3377) Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 14

Physical Properties of Test Samples Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 15

Process of Annealing Samples Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 16

Timing Optimization (Fast Plastic) Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 17

Timing Optimization (BaF 2 ) Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 18

Lifetime Extraction Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 19

Kansy LT10 Software Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 20

Source-based Fast Plastic Results: 22 Na without Sample Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 21

Source-based Fast Plastic Results: Aluminum Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 22

Source-based Fast Plastic Results: Copper Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 23

Source-based Fast Plastic Results: Nickel Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 24

Source-based Fast Plastic Results: Lead Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 25

Source-based Fast Plastic Results: Summary Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 26

Source-based Conclusions A high precision lifetime spectrometer has been constructed and successfully benchmarked; Brian Wieland s Masters degree Bulk positron lifetimes in high-purity aluminum, copper, nickel, and lead are in excellent agreement with current literature values Measured defect lifetime values may differ from literature values as a result of different types of defects within the unannealed samples Spectrometer is capable of resolving difference between annealed and unannealed samples Spectrometer is capable of detecting surface defects caused by oxidation of materials Additional studies will need to be completed for BaF 2 scintillators This study lays the foundation for future accelerator-based positron annihilation lifetime spectroscopy to access volume defect densities Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 27

Accelerator-based PALS Initial Goal: Reproduce source-based lifetime measurements using the 27 Al(p,γ) 28 Si proton-capture reaction Decay of excited Si nucleus often produces two or more photons: One is used as the positron birth signal while the other produces e + e pairs in the sample leading to the 511keV death signal Initial measurements used 2MeV Van de Graaf, however 10µA maximum beam current produced extremely limited event-rates ( 0.2Hz) Pelletron capable of 200µA and up to 8MeV; fabricated custom Al beamline; first PALS experiments conducted May 2012 Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 28

Accelerator-based Experimental Setup Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 29

27 Al(p,γ) 28 Si Cross Section Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 30

27 Al(p,γ) 28 Si Photon Spectrum Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 31

Pelletron-based PALS: Studies Event rates for various sample-detector geometries sample size and distance from Al endcap very important Event rates for various shielding configurations need to block line of sight between two detectors, helped to block stop detector from line of sight to Al endcap, although in general shielding is problematic for obvious reasons Event rates and energy spectra for different proton energies found that beam energy needs to be 10-20% above 0.992MeV resonance; beyond 2-2.5MeV, individual pmt event rates/system deadtime saturated Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 32

Shielding-Sample-Detector Configurations Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 33

Pelletron-based PALS: Issues Given the current spectrometer design, the PALS coincidence event rates are only 2-5Hz at best depending on beam current, sample thickness and shielding; = 60 hour data-runs to reach 1M events Experiment suffers from isotropic photon beam and small solid angle acceptance of detectors in conjunction with coincidence-style measurement Background events difficult to separate from sample events BaF 2 scintillator spectra from Pelletron not yet fully understood this should provide better background rejection Detector signals often exceeded max specs for processing electronics needed to operate pmts at much lower voltages than optimal Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 34

Accelerator-based PALS: Ideas and Future Work Use fluorine reaction instead of aluminum reaction can get 4 times more rate with higher photon energies but still isotropic beam A very high rep-rate or CW electron to bremsstrahlung beam would be great; ideally... energy tunable CW positron beam... Increase numbers of detectors to improve solid angle coverage Employ back-to-back 511keV (stop) detectors for greatly improved background rejection Use two CFDD currently we have only one CFDD and one CFD accepts more background Simulation work is ongoing to understand issues related to shielding, sample thickness limitations for 511keV photon escape, photon multiplicities from excited Si decays,... Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 35

Simulation Studies: MC-NPX Input Deck Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 36

Simulation Studies: 511 γ Survival Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 37

Simulation Studies: All γ Survival Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 38

Accelerator-based PALS: Conclusions R & D for AG-PALS (volume defect essay) is still in early stages as there are many technical hurdles to overcome Obviously event rate is a big problem with the current measurements; if we reduce our measurement statistics requirements to 200k events could achieve in 12 hours with Pelletron The PALS data is rich with information as compared with PAES but technically much more challenging Investment in both accelerator and spectrometer design is needed for viable AG-PALS and even more so for if one is to achieve imaging measurements There is currently one PhD candidate working on this and potentially more in the queue Dustin McNulty, Idaho State University Department of Physics, http://www.physics.isu.edu/ mcnudust 39