arxiv:physics/ v1 22 Dec 2003

Similar documents
The BABAR Electromagnetic Calorimeter: Status and Performance Improvements

The CsI(T1) C a 1 orimeter of the BABAR Detector*

arxiv:hep-ex/ v1 31 Dec 2001

Results from BABAR/PEP-II - One Year of Operations

A gas-filled calorimeter for high intensity beam environments

Simulation and validation of the ATLAS Tile Calorimeter response

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

τ lepton mass measurement at BESIII

ATLAS EXPERIMENT : HOW THE DATA FLOWS. (Trigger, Computing, and Data Analysis)

Calibration and Monitoring for Crystal Calorimetry

Recent results at the -meson region from the CMD-3 detector at the VEPP-2000 collider

1 Introduction STATUS OF THE GLAST LARGE AREA TELESCOPE. SLAC-PUB December Richard Dubois. Abstract

Calibration of the BABAR CsI (Tl) calorimeter

INORGANIC crystal scintillators are widely used in high

Calibration and Performance of the ATLAS Tile Calorimeter During the LHC Run 2

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

1 Introduction The SLAC B Factory asymmetric B-factories was approved by President Clinton in October B-factories The inaugural meeting of the d

The CMS ECAL Laser Monitoring System

Scintillation Detector

Physics sources of noise in ring imaging Cherenkov detectors

PoS(DIS 2010)058. ATLAS Forward Detectors. Andrew Brandt University of Texas, Arlington

ISR physics at BABAR

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals

arxiv: v1 [physics.ins-det] 3 Feb 2011

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Status of PEP-II and BaBar. 1 Introduction. 2 PEP-II Machine

REVIEW OF CRYSTAL CALORIMETERS

PoS(BORMIO2016)013. PANDA Forward Spectrometer Calorimeter. P.A. Semenov IHEP NRC KI S.I. Bukreeva IHEP NRC KI ITEP NRC KI

Since the beam from the JNC linac is a very high current, low energy beam, energy loss induced in the material irradiated by the beam becomes very lar

Calibration of the CMS Electromagnetic Calorimeter with first LHC data

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate

Monte Carlo Calculations Using MCNP4B for an Optimal Shielding Design. of a 14-MeV Neutron Source * James C. Liu and Tony T. Ng

Muon reconstruction performance in ATLAS at Run-2

A Gaussian Fitter for the CESR-c Fast Luminosity Monitor

Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

What detectors measure

Occupational Radiation Protection at Accelerator Facilities: Challenges

Performance and Aging of the BABAR Drift Chamber

Quantitative Assessment of Scattering Contributions in MeV-Industrial X-ray Computed Tomography

The BaBar CsI(Tl) Electromagnetic Calorimeter

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Upgrade plans for the ATLAS Forward Calorimeter at the HL-LHC

Parametric down-conversion

THE main physics motivation for building the Compact

David Gascón. Daniel Peralta. Universitat de Barcelona, ECM department. E Diagonal 647 (Barcelona) IFAE, Universitat Aut onoma de Barcelona

The relevance of XENON10 constraints in this low-mass region has been questioned [15] C.E. Aalseth et al. arxiv: v1

Nicolas Berger SLAC, Menlo Park, California, U.S.A.

Calorimetry in particle physics experiments

arxiv: v1 [physics.ins-det] 3 Dec 2018 Fast Interaction Trigger for the upgrade of the ALICE experiment at CERN: design and performance

Alpha-Energies of different sources with Multi Channel Analyzer

Light ion recoil detector

Fast Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon PIN Diodes and APDs

CMS ECAL status and performance with the first LHC collisions

Guest Lecture PHY 7361: Harnessing Cherenkov Radiation SteveSekula, 13 April 2010 (created 9 April 2010)

Commissioning of the ATLAS LAr Calorimeter

High-energy Gamma Rays detection with the AMS-02 electromagnetic calorimeter. F. Pilo for the AMS-02 ECAL Group INFN Sezione di Pisa, Italy

X-ray ionization yields and energy spectra in liquid argon

Evaluation and Measurements of Radioactive Air Emission and Off-Site Doses at SLAC

Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

arxiv: v1 [physics.ins-det] 11 Mar 2010

THE PEP-II B-FACTORY AND THE BABAR DETECTOR

A Study on Radiation Damage in PWO-II Crystals

LHCb Calorimetry Impact

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

1 Introduction. KOPIO charged-particle vetos. K - RARE Meeting (Frascati) May Purpose of CPV: veto Kl

The DAΦNE Luminosity Monitor

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

Validation of Geant4 Physics Models Using Collision Data from the LHC

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Neutron Generators For Calibration

Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools

ATLAS Tile Calorimeter Calibration and Monitoring Systems

The low Q 2 chicane and Compton polarimeter at the JLab EIC

arxiv: v2 [nucl-ex] 6 Oct 2008

Geant4 simulation for LHC radiation monitoring

Absorption and Backscattering of β-rays

Geant4 simulations of the lead fluoride calorimeter

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

PoS(EPS-HEP2015)565. Study of the radiative tau decays τ γlνν with the BABAR detector. Roger Barlow

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

ATLAS Hadronic Calorimeters 101

The Large Area Telescope on-board of the Fermi Gamma-Ray Space Telescope Mission

arxiv: v2 [physics.ins-det] 17 Jun 2014

Research and Development for the ATLAS Forward Calorimetry at the Phase-II LHC

Using Neutron Generator with APT/NNA for Detection of Explosives

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

The electromagnetic calorimeter of the HERA-B experiment

PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

- he [I+ P,P,A (~%)l,

PoS(KAON13)012. R K Measurement with NA62 at CERN SPS. Giuseppe Ruggiero. CERN

A POSITION SENSITIVE ALPHA PARTICLE DETECTOR BASED ON A LYSO CRYSTAL AND A MICRO-PIXEL AVALANCHE PHOTODIODE

Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P )

SLAC-PUB Submitted to Radiation Protection and Dosimetry. Work supported by Department of Energy contract DE-AC02-76SF00515

Detectors for High Resolution Gamma-ray Imaging Based on a Single CsI(Tl) Scintillator Coupled to an Array of Silicon Drift Detectors

Transcription:

SLAC-PUB-1289 UMS-HEP-23-27 November 23 Absolute Energy Calibration with the Neutron-Activated Liquid-Source System at BABAR s CsI(Tl) Calorimeter arxiv:physics/312128 v1 22 Dec 23 J. M. Bauer Department of Physics and Astronomy University of Mississippi, University, MS 38677, USA for the EMC group of the BABAR Collaboration Stanford Linear Accelerator Center Stanford University Stanford, CA 9439, USA Abstract The electro-magnetic calorimeter at the BABAR detector, part of the asymmetric B Factory at SLAC, measures photons in the energy range from 2 MeV to 8 GeV with good resolution. The calorimeter is calibrated at the low energy end with 6.13 MeV photons obtained from a liquid source system. During the calibration, a fluorine-rich liquid is activated via a neutron generator and pumped past the front of the calorimeter s crystals. Decays that occur in front of the crystals emit photons of well-defined energy, which are detected in the crystals with the regular data acquisition system. The liquid source system adds only very little material in front of the calorimeter, needs nearly no maintenance, and allows operation at the switch of a key with minimal safety hazards. The report describes the system, presents calibration results obtained from its operation since 1999, shows the crystals loss of light yield due to radiation damage, and shares experiences gained over the years. Presented at the 23 IEEE Nuclear Science Symposium and Medical Imaging Conference Portland, OR, USA October 19, 23 October 25, 23 Submitted to IEEE Transactions on Nuclear Science Work supported by Department of Energy contract DE AC3 76SF515 and Department of Energy grant DE-FG5-91ER4622.

Absolute Energy Calibration with the Neutron-Activated Liquid-Source System at BABAR s CsI(Tl) Calorimeter Johannes M. Bauer, Member, IEEE, for the EMC group of the BABAR Collaboration Abstract The electro-magnetic calorimeter at the BABAR detector, part of the asymmetric B Factory at SLAC, measures photons in the energy range from 2 MeV to 8 GeV with good resolution. The calorimeter is calibrated at the low energy end with 6.13 MeV photons obtained from a liquid source system. During the calibration, a fluorine-rich liquid is activated via a neutron generator and pumped past the front of the calorimeter s crystals. Decays that occur in front of the crystals emit photons of well-defined energy, which are detected in the crystals with the regular data acquisition system. The liquid source system adds only very little material in front of the calorimeter, needs nearly no maintenance, and allows operation at the switch of a key with minimal safety hazards. The report describes the system, presents calibration results obtained from its operation since 1999, shows the crystals loss of light yield due to radiation damage, and shares experiences gained over the years. Index Terms CsI(Tl), calorimeter, calibration, neutron sources, radiation damage. I. INTRODUCTION SINCE 1999, the asymmetric B Factory at the Stanford Linear Accelerator Center (SLAC) has been collecting data from collisions of 9 GeV electrons and 3.1 GeV positrons. The B mesons that are created at this 1.58 GeV center-ofmass energy are the major topic of the physics studies at the BABAR detector [1] which records the decay products of the B mesons. The detection of photons and π mesons, which mainly decay into photon pairs, with high efficiency and good energy resolution is of utmost importance to the physics program [2] [3]. This task is handled by the electromagnetic calorimeter (EMC) of the BABAR detector, designed for the detection of photons in the energy range from 2 MeV to 8 GeV. The detector consists of 576 CsI(Tl) crystals arranged cylindrically in 48 rows along the polar angle (the so-called ), and 82 CsI(Tl) crystals arranged in 8 rows at the forward end of the detector ( ), as illustrated in Figs. 1 and 2. Each crystal is of trapezoidal shape with a front face area of approximately 47 mm 47 mm and a length of 297.6 mm to 325.5 mm (16. to 17.5 radiation lengths). Manuscript received November 14, 23. The author was supported by U.S. Dept. of Energy grant DE-FG5-91ER4622. J. M. Bauer is with the Department of Physics and Astronomy, University of Mississippi, University, MS 38677, USA (e-mail: bauerj@slac.stanford.edu). Fig. 1. Cut-out drawing of the cylindrical electromagnetic calorimeter s arrangement of crystals. The support structure (not shown) is at the back of the crystals to minimize the amount of material in front of the crystals. 1375 92 38.2 1555 2295 1127 181 558 2359 22.7 External Support 15.8 26.8 Interaction Point 1-21 1979 8572A3 Fig. 2. Longitudinal cross section of the calorimeter. Spatial dimensions are given in millimeters. II. REQUIREMENTS In order to reach good energy resolution in the calorimeter, accurate calibration of the crystals over the full energy range is essential. Because radiation from the e + e beams damages the crystals over time, frequent calibrations are necessary to avoid a drop in energy resolution. For lowest energies, this calibration is achieved through the neutron-activated liquid-source system that is the subject of this report. A calibration accuracy of.5% was required for the liquid source calibration system. For

Fig. 3. The neutron-generating unit of the neutron generator system. comparison, we list here the measured energy resolution of the calorimeter (first error statistical, second error systematic) [4]: σ E E (2.3 ±.3 ±.3)% = (1.35 ±.8 ±.2)%. (1) 4 E(GeV) Fig. 4. A look into the radiation shielding bunker. The round structure inside is the bath designed to hold the neutron generator. III. APPARATUS AND CALIBRATION PROCEDURE A. The Neutron Generator The calibration relies on the reaction 19 F + n 16 N + α and the subsequent decay of 16 N (T 1/2 = 7 seconds) via 16 O into 16 O and a 6.13 MeV photon. The neutrons originate from a deuterium-tritium neutron generator ([5], Fig. 3) located in a concrete bunker with approximately.8 m thick walls adjacent to the BABAR detector. It provides 14 MeV neutrons with a continuous flux of up to 1 9 n/s when its high voltage is turned on remotely. A bath (Fig. 4) surrounding the generator holds Fluorinert TM FC-77 [6], an inert fluid rich in fluorine that the neutrons activate to 16 N. B. The Tube System A pump with a supply pressure of around 4 kpa transports the activated liquid at a rate of 15 L/min, from the neutron generator and bath, through pipes into the BABAR detector, forces it through thin-walled aluminum tubes in front of the crystals, and leads it back to the bath in a continuous loop. Since only a 15 mm gap was available between the inside of the calorimeter and the next subsystem, the panels sliding into this gap were allowed to have a thickness of maximal 5 mm. Fig. 5 shows one such panel in production. Round aluminum tubes of 1 mm diameter with.5 mm wall thickness were flattened to a 3 mm height, embedded in polyurethane and covered with.4 mm thick aluminum sheets on both sides. Fig. 6 shows panels at their installation location at the inside of the calorimeter. The design was different for the, as can be seen in Fig. 7. Fig. 5. Fabrication of the panels with the top aluminum shield still missing. One can see the flattened aluminum tubes running up and down embedded in polyurethane. C. The Data Acquisition Photons emitted in the decay of 16 N enter the crystals of the calorimeter at a typical rate of 4 Hz per crystal. According to Monte Carlo simulations, about 3% of them deposit at least 3 MeV in an individual crystal. The energies are measured through the regular data acquisition system, starting with the detection of the scintillation light by a pair of photo diodes. The signal from the photo diodes passes through an analog amplifier mounted at the back of the crystal, then to a 3.7 MHz digitizer at the side of the detector. Via optical fiber the signal arrives in Versa Module Europa (VME) crates at readout

Events /.47 MeV 2 1 Fig. 6. Barrel panels in place at the inside of the electromagnetic calorimeter. 4 6 8 Energy (MeV) Fig. 8. Calibration spectrum of one crystal. The fit identifies the contribution of the 6.13 MeV photons (right Gaussian) and the 1 st and 2 nd escape peak (middle and left Gaussians). modules (ROMs) with embedded processors running VxWorks. Since the data acquisition system is designed for the triggered collection of colliding beam events, not for random photons from the source calibration system, a pulse generator provides triggers of about 2 khz to begin the data acquisition sequence. The ROMs select 128 samples of the wave form that arrives from each crystal. Since the decay time of CsI(Tl) is quite long (several hundred nanoseconds) and since the samples are taken every 27 ns, the signal spreads over several samples of the wave form. If at least one of these samples is above a pre-defined threshold of the crystal, the wave form is sent to a digital filter. The filter is based on weights optimized for the background conditions of the source calibration and is able to reduce the electronics noise. Then the peak height is determined with a parabolic fit to the peak of the filtered wave form. If the peak is still above the threshold of the crystal, its value in ADC counts is accumulated into an energy spectrum as shown in Fig. 8. At the end of the source calibration run, each ROM writes the spectra to a file. Since data are taken at a trigger rate of about 2 khz and since each wave form has an effective time window of 26 µs, a live-time of about 5% is reached. Noisy channels can decrease the performance of the data acquisition, and they are therefore masked out as well as possible by raising their thresholds for the data acquisition. Fig. 7. One half of the with installed network of flattened aluminum tubes in the front. D. Fitting the Energy Spectra The energy spectra are fitted off-line to three Gaussians centered around the 6.13 MeV peak and two escape peaks and to a parameterization of the Compton background and electronics noise. Other lines from the decay of 16 N are negligible at the present energy resolution. Since the energy of the peaks is well-known, the fit returns the overall gain (number of ADC counts per MeV) as well as the resolution, defined here as the widths of each of the three Gaussian peaks. Since digital

Counts/.8 MeV 4 3 2 relative LY change -.2 -.4 -.6 backward forward 1 -.8.2.4.6.8 Resolution (MeV) Fig. 9. Measured resolutions for a typical source calibration run. The resolution is defined as the width of each of the three Gaussians illustrated in Fig. 8. filtering reduces the electronics noise to about 23 kev, an average energy resolution of about 3 kev is reached (Fig. 9). This resolution is better than expected from (1) because no beams are present during the source calibration, the digital filter weights are optimized for this no-beam situation, and because the photons originate right in front of the crystals and reach the crystals after passing through only a small amount of material. The systematic error of the measurement is estimated to be not more than.1%. E. Applying the Constants in Data Analysis After each calibration run, the calibration constants of each crystal are recorded into a database. When data collected during normal e + e collisions are processed, the energy measured in each crystal is adjusted via an interpolation between the lowenergy source calibration constants and high-energy calibration constants from Bhabha events [1]. IV. OPERATIONAL AND SAFETY ISSUES The liquid source system is able to measure the light yield to high precision in runs that last 15 to 3 minutes. The runs are performed every ten days, on average, at times when no e + or e beams are present in the collider rings. The aluminum panels with flattened tubes and liquid add only about 2% in radiation length to the material in front of the calorimeter and therefore affect the physics data in only a minimal way. The system requires nearly no maintenance, and safety hazards are minimal. The neutron generator is located safely inside a locked radiation-shielding bunker and only generates neutrons when its high voltage is turned on. The hazard of Fluorinert TM is negligible, even to the crystals, and the short life-time of the activated fluid minimizes any radiation exposure in case of an accidental spill. 2 1999 2 21 22 23 Fig. 1. Relative change in light yield (measured as gain in ADC counts/mev) since September 1999. The average shift of the crystals is shown for three different subsets of the crystals. The shaded areas indicate major periods without beams. V. RESULTS Calibration runs started in 1999 when the asymmetric B Factory began its operation. Fig. 1 illustrates how the average light yield of the crystals dropped over time for the, the forward, and the backward. The largest drop is seen in the forward ( 12%), while the smallest drop is found in the backward ( 4%). The shaded areas in Fig. 1 mark major durations without beams. Each point in Fig. 1 is an average over crystals from different manufacturers, located in different places within the calorimeter, and receiving different radiation doses. To illustrate the spread of these measurements, Fig. 11 presents the light yield change from September 1999 to October 23 versus the 56 crystal ring. The crystal ring number corresponds to the order in polar angle as shown in, e.g., Fig. 2. The ranges from ring 1 to ring 8, which is adjacent to the forward (rings 9 to 29), followed by the backward (rings 3 to 56). In the average, a larger change is seen toward the forward end (low crystal ring numbers), and smaller changes at the backward end, but within each crystal ring the crystals show quite some spread. The same data are plotted in Fig. 12 with the mean and its error (solid line) and the spread (dotted line). One clearly sees several rings with larger light yield changes than their neighbors, like crystal rings 23 to 27 and ring 52. Since those crystals were obtained from a different manufacturer than the surrounding crystals, the dependency of the light yield change on the crystal manufacturer is studied more below. Each plot in Fig. 13 shows the distribution of the light yield change for a certain range of crystal rings for two manufacturers. Clearly the light yield change is less for the solid histogram in the left plot (Vendor A) than for the open

relative LY change Fig. 11..2.1 - -.2 -.3 -.4 -.5 forward backward 1 2 3 4 5 crystal ring Distribution of the relative light yield change versus crystal rings. crystal rings 17-22 Vendor A Vendor B -.3 -.2 rel. LY change crystal rings 3-36 Vendor C Vendor A -.3 -.2 rel. LY change crystal rings 37-43 Vendor C Vendor A -.3 -.2 rel. LY change Fig. 13. Relative change in light yield from September 1999 to October 23 for crystals in three regions of crystal rings. The solid histogram contains the numbers for Vendor A, while the open histogram contains the numbers for Vendor B (left) and Vendor C (middle & right). The open and solid histograms are normalized to the same area. relative LY change.5 - -.5 5 -.2 -.25 forward backward 1 2 3 4 5 6 crystal ring Fig. 12. Relative change in light yield from September 1999 to October 23 versus crystal ring. The solid error bars indicate the error on the mean, the dotted line the spread. Crystals with light yield changes above 5% and below 25% were excluded to avoid bias through outliers. histogram (Vendor B). In the next two plots, the crystals from Vendor C (open histograms) show even less change than the crystals from Vendor A. By restricting each plot in Fig. 13 to few crystal rings, the crystal that are compared are ensured to have received similar radiation doses. The radiation received by the calorimeter is also monitored by 116 special Field Effect Transistors (RadFET) mounted at the front of the crystals [7]. Although their measurements might not be completely representative for the dose received by the crystals because they are based on different physical principles, important conclusions may still be drawn. The measurements indicate that the radiation dose inside the is not varying widely, so that the difference in the light yield changes seen from the source calibration runs might be mainly due to crystals originating from different vendors. The radiation dose to the, however, is larger than to the. The is thought to receive additional radiation at the rear of the crystals from beam background originating from the beam line, and not only radiation from the front. Similar conclusions on the radiation dose are also reached from studies of the change in the leakage current of the crystals photo diodes [8]. In Fig. 14, the light yield changes are plotted versus the radiation dose as measured by the RadFET at the time of relative LY change -.2 -.4 -.6 -.8 2 backward forward 1-2 1-1 1 radiation dose (krad) Fig. 14. Relative change in light yield since September 1999 (as shown in Fig. 1) plotted versus the radiation dose measured by RadFETs. the source calibration runs. Since RadFET measurements are available from May 1999 onward, when beams started to pass through the BABAR detector, the data points in Fig. 14 are offset horizontally, especially for the. Many factors may affect the quantities shown in this plot, for example, the beam conditions that were changing over time, and care must be taken when interpreting the plot. At the time of construction, the specifications for the crystals required that their light yield response was uniform along the length of the crystal. But since during operation many more low-energy photons hit the crystals in the front than in the rear (especially in the ), it is possible that the front of the crystals is being damaged more than the rear of the crystals. So far the drop in light yield appears to be similar when comparing the results from the low-energy liquid source calibration and the high-energy Bhabha calibration [8]. Changes in light yield uniformity are further studied in [9].

VI. CONCLUSION Operating with minimal maintenance requirements and minimal safety hazards, the liquid source calibration system at BABAR is frequently measuring the light yield of the crystals at low energy to the.5% accuracy that it was designed for. By monitoring the light yield changes, the system corrects for the effects of radiation damage caused to the crystals over time and allows the resolution of the calorimeter to remain optimal. The liquid source system therefore serves the need of the electro-magnetic calorimeter very well. ACKNOWLEDGMENT The author would like to thank the BABAR EMC group for all their contributions to the calorimeter and the liquid source system, making possible and very worthwhile the calibrations described in this report. He would also like to congratulate and extend his gratitude to the whole BABAR Collaboration and the PEP-II accelerator group for their tremendous accomplishments. REFERENCES [1] BABAR Collaboration, B. Aubert, A. Bazan, A. Boucham, D. Boutigny, I. De Bonis, J. Favier et al., The BABAR detector, Nucl. Instr. and Methods A 479, 1 (22). [2] BABAR Collaboration, B. Aubert, R. Barate, D. Boutigny, J.-M. Gaillard, A. Hicheur, Y. Karyotakis et al., Observation of the decay B π π, hep-ex/3812, submitted to Phys. Rev. Lett. [3] BABAR Collaboration, B. Aubert, R. Barate, D. Boutigny, J.-M. Gaillard, A. Hicheur, Y. Karyotakis et al., Observation of a narrow meson decaying to D + s π at a mass of 2.32 GeV/c 2, Phys. Rev. Lett 9, 2421 (23). [4] M. Kocian, Performance and calibration of the crystal calorimeter of the BABAR detector, in Proceedings of the Tenth International Conference on Calorimetry in Particle Physics (CALOR 22), Pasadena, CA, USA, 22, pp. 167-174. [5] Model ING-7, All-Russian Research Institute of Automatics (VNIIA), Moscow, Russia. [6] 3M Corporation, St. Paul, MN, USA. [7] B. Camanzi, H. B. Crawley, A. Holmes-Siedle, R. L. McKay, A. McKemey, W. T. Meyer et al., The BABAR RadFET monitoring board, IEEE Trans. Nucl. Sci. vol. 44, no. 3, pp. 1275-128, June 22. [8] T. Hryn ova, A systematic study of radiation damage to large crystals of CsI(Tl) in the BABAR detector, in Proceedings of the Tenth International Conference on Calorimetry in Particle Physics (CALOR 22), Pasadena, CA, USA, 22, pp. 175-181. [9] T. Hryn ova, A systematic study of radiation damage to large crystals of CsI(Tl) for the BABAR detector, IEEE Nuclear Science Symposium and Medical Imaging Conference, Portland, OR, USA, October 23.