for Single mixing applications

Similar documents
Stopped-flow accessories

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

novaa 800 D Atomic Absorption Spectrometer

Nano Spectrophotometer LNS-A10

SPECTROPHOTOMETERS. Visible and UV-Visible

TL6 Ultra Micro-volume Spectrophotometer

The solution for all of your

ChromTech HPLC System

lis Rethink your possibilities Scatter Does Not Matter! Only Sample Absorbance Does. SPECTROPHOTOMETER SERIES

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

ZS90. The ultimate in desktop particle characterization. Particle size. Zeta potential. Molecular weight

CHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND

Water in Food 3 rd International Workshop. Water Analysis of Food Products with at-line and on-line FT-NIR Spectroscopy. Dr.

Experimental Methods in Kinetics (2014)

The Plus for your lab!

BioDrop DUO dsdna Application Note

CLINICAL CHEMISTRY ANALYSER. The economical solution for all your needs GIVING YOU PEACE OF MIND

An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science Research.

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

IRMS. perspective. Isotope Ratio Mass Spectrometry.

Modulyzer. Multiparameter Measuring Systems. ::: Unique Density & Concentration Meters

The Clinical Chemistry System that offers more so you do less!

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

DI 3500 Discrete Aoalvzer

FLUORESCENCE APPLICATIONS

Chemistry 524--Final Exam--Keiderling Dec. 12, pm SES

10 REASONS THAT THE ZETASIZER NANO IS CHOSEN FOR SCIENTIFIC SUCCESS

Varian Galaxie Chromatography Data System for Preparative HPLC

PERSPECTIVE STABLE ISOTOPE RATIO MS

Instrumental Technique: Cuvette. Md Rabiul Islam

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

A DIVISION OF ULVAC-PHI

1901 Application of Spectrophotometry

Spectrometer User s Guide

ION CHROMATOGRAPHY SYSTEM S 150

Fluorescence Visual Gel-separation of Dansylated BSA-protected Gold-Nanoclusters

BIOLIGHT STUDIO IN ROUTINE UV/VIS SPECTROSCOPY

Particle Analysis at the Touch of a Button. Litesizer series

Compact Knowledge: Absorbance Spectrophotometry. Flexible. Reliable. Personal.

Quantum Northwest, Inc. Product overview

C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science

Atomic Absorption Spectrometer ZEEnit P series

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system

LABORATORY OF ELEMENTARY BIOPHYSICS

Electronic Excitation by UV/Vis Spectroscopy :

Optical In-line Control of Web Coating Processes with UV-VIS-NIR Spectroscopy. AIMCAL Europe Web Coating Conference Peter Lamparter

LIBSlab ANALYZERS ANALYZERS

Contents. xiii. Preface v

Nanoparticle Analyzer

Your partner in Science!

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Introduction to Fourier Transform Infrared Spectroscopy

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry

Spectroscopy. Page 1 of 8 L.Pillay (2012)

Smart Sensing Embedded Spectroscopy Platform Botlek studiegroep 06-april-2017

Quad-Z 215 with Disposable Tips: Implementing the Use of ZipTips for the Purification of Biological Samples

Rapid Catalyst Screening Reactors

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

VIBRATION-ROTATION SPECTRUM OF CO

PHI. Scanning XPS Microprobe

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

A new chapter. medicacorp.com

Principles of Physical Biochemistry

Chirascan 6-Cell Peltier Cell Holder: Rapid Optimisation of Buffer Conditions for Stabilising Protein Therapeutics

Supporting Information s for

PERSPECTIVE STABLE ISOTOPE RATIO MS

THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

Chem 524 Lecture Notes CD (Section 18) update 2011

costech instruments ECS 4010 Elemental Combustion System CHNS-O

UV-Vis optical fiber assisted spectroscopy in thin films and solutions

Chapter 15 Molecular Luminescence Spectrometry

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

R O Y G B V. Spin States. Outer Shell Electrons. Molecular Rotations. Inner Shell Electrons. Molecular Vibrations. Nuclear Transitions

Finnigan LCQ Advantage MAX

DETERMINATION OF RELATIVE FLUORESCENCE QUANTUM YIELD USING THE AGILENT CARY ECLIPSE

The Effect of the Stoichiometry in the Supramolecular Chirality Transfer to Zinc Bisporphyrins Systems

Fluorescence Spectrophotometry

Photoluminescence Spectrometer (FLS980)

The THT micro reaction calorimeter RC

Basics of UV-Visible Spectroscopy *

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Chem 310 rd. 3 Homework Set Answers

Measuring Lysozyme Monomer at 0.1 mg/ml Concentration. Equipment used : Sample Preparation and Measurement :

Biochemistry. Biochemical Techniques HPLC

Nucleic Acid Quantitation in Microplates

A DIVISION OF ULVAC-PHI. Quantera II. Scanning XPS Microprobe

JAPAN QUALITY. Automated Clinical Analyzer

high performance OPTIC 3 and applications a total analytical solution

The fastest compact NMR spectrometer. spectrometer has superb sensitivity and the performance to provide useful results immediately.

The ultimate in desktop particle characterization

FLS980 Series Reference Guide

ActiPix SDI300 Surface Dissolution Imaging System

Clark Atlanta University Center for Surface Chemistry and Catalysis Instrument Capabilities

Application Note: Ocean Optics in the Teaching and Research Laboratories Susquehanna University Department of Chemistry July 2014

Transcription:

RAPID KINETICS AND SPECTROSCOPY SFM-20 2 SYRINGE STOPPED-FLOW SYSTEM for Single mixing applications

The SFM-20 is a high performance, modular stopped-flow system, designed for single mixing rapid kinetics applications. With reliable research grade performance, the modular SFM-20 is easy to use and user-friendly for everyone from students to experienced researchers. The SFM-20 is the most efficient 2 syringe stopped-flow on the market. Not only is it economical to buy, it is ideal in terms of sample economy, with a priming volume of only 50 μl. Many user installable options let you adapt the SFM-20 to changing needs in your lab, without buying a complete new system. Bio-Logic s unique and completely Independent stepping motor technology offers full control over volume and velocity of flow, with mixing ratio control to the μl level. The included control software lets you quickly program a series of shots at various concentrations. User selectable syringe volumes let you load the system once, and do a lengthy series of shots without refilling. Mixing is done using advanced Berger-Ball technology which provides the best possible turbulent mixing over the widest range of flow conditions. Berger-ball technology offers outstanding consistency and repeatability over classic T-mixers. The SFM-20 is controlled from a PC using the included Bio-Kine software and a USB connected control module. The software provides powerful and simple menus to design mixing sequence and multi-concentration experiments. Safeguards in the software alert you to out of range conditions in mixing ratios, calculate flow rates, and the maximum number of shots available. The SFM-20 can be coupled to all Bio-Logic spectrophotometers, and also external CD spectrometers, fluorometers, synchrotron radiation beam lines, NMR, EPR, freeze-quench, and many others... General Specifications: c Single mixing application c 0.6 ms dead time c Mixing ratio 1:1 to 1:40 c Exact control of flow rate c Sample economy c User selectable syringe volumes c Compatible with: MOS-200 MOS-250 MOS-450/AF-CD MOS-DA MCS-200 External devices... unique features c Independent stepping motors c Automatic concentration dependence studies c Mixing ratio is fully flexible and programmable from Bio-Kine c No sample and syringe handling between shots using different mixing ratio c μl precision No pressure artifacts RAPID KINETICS AND SPECTROSCOPY

applications BIOCHEMISTRY PROTEIN FOLDING UNFOLDING/MISFOLDING ORGANIC & INORGANIC CHEMISTRY structural changes O N S N H N H O OCH 3 Protein folding is the physical process by which a polypeptide folds into a characteristic three dimensional structure. Formation of the 3D structure is essential for the protein s functions. Understanding these processes is essential for both academic and pharmaceutical research. With independent syringes and completely variable mixing ratio, the SFM-20 is ideal for studying protein folding. This application often involves mixing solutions of different viscosities. Bio-Logic has a micro-volume Berger-ball mixer specially designed for perfect mixing of viscous, (up to 2000 cp,) solutions. For reactions longer than 10-15 seconds, a unique high density mixer is available to minimize convection artifacts often observed using pneumatic technology. The flexibility of mixing ratios and differing sample viscosities offered by the SFM-20 give the user the most control of experiment design and sample economy. Detecting protein folding is most often done with fluorescence and circular dichroism techniques. The SFM-20 is easily combined with a Bio-Logic MOS-200 or MOS-450 spectrophotometer to bring you the best mixing and analytical performance. The SFM-20 also has a new mt-jump accessory, which uses temperature change as the trigger for folding or unfolding. The mt-jump accessory is one of the many valuable options available for the SFM-20. Understanding reaction mechanisms and characterizing the structure of reaction intermediates is a common goal in organic and inorganic chemistry. Most reactions occur in organic solvents. This requires instruments that can maintain design function and performance in an aggressive environment. The SFM-20 mixer components and optional Isolast O-ring set easily withstand exposure to solvents such as THF and toluene. For studies where a reactant is oxygen sensitive, the SFM-20 anaerobic option provides a simple and reliable way to perform an experiment in an oxygen limited environment. Some intermediates have very short life times, and can only be observed through cryogenic methods. The SFM-20 mix-freeze option captures intermediates down to -90 C. This opens up a complete new range of studies that are difficult or impossible with conventional mixing systems. Absorbance measurements are the most popular detection method, and the SFM-20 can be combined with the MOS-200 or MOS-450 for single wavelength measurements. For fast multiwavelength measurements, it can also be coupled with our extra-fast diode array detectors. The included Bio-Kine software controls both mixer and detection system, and can analyze 2D and 3D data ( SVD analysis) to extract intermediate information from the kinetics data. ENZYME KINETICS LIGAND BINDING CONFORMATIONAL CHANGES E + S k 1 k -1 ES k 2 E + P WATER AND IONS TRANSPORT IN VESICLES Stopped-flow has long been a key technique for understanding enzyme kinetics. Single and multi-substrate reactions can be followed with stopped flow techniques to study the catalytic mechanism of an enzyme, and to learn about its role in the cell. Mechanisms can be investigated by changing reactant concentrations, and by adding fluorescent dyes to the protein to enable observation of movements during reactions. The SFM-20 can be used for all optical techniques to detect conformational changes. With independent stepping motors, users can change mixing ratios after each shot without refilling the system, so a series of concentration studies can be done rapidly. Bio-Kine s analytical tools provide immediate information about the reaction mechanism. Other applications : Micelles, Second messenger, drug design, polymerization A common application of stopped-flow is fast tracking of transient kinetics of water (or solute) transport across the membranes of small (10-500 nm scale) vesicles. These reactions can be generated by mixing purified membrane vesicles with a hyperosmotic solution. The concentration gradient induces a fast flow of water out of the vesicles. The volume of vesicles is reduced in a kinetic reaction. With the SFM-20, membrane permeability can be evaluated from the measured rate constants. Vesicles are very sensitive to change of pressure. With the SFM- 20 s precise control of total flow rate, sheer forces are minimized so the integrity of vesicles is not affected. A synchronized electrovalve stops the sample flow and prevents the occurrence of overpressure artifacts. The SFM-20 coupled to one of our spectrometer is an ideal system for 90 light scattering and fluorescence, often used to following such reactions in blood cells, aquaporins, liposomes, and for water purification applications.

software BIO-KINE control and analysis software is included with Bio-Logic mixers and spectrometers. It is a powerful, intuitive, and easy to use tool for stopped-flow measurements. Bio-Kine controls all functions of the stopped-flow and the detection device, and provides full analytical capabilities for the collected data. Basic level Two levels of operation are provided for mixer control. The first level is designed for rapid and easy experiment design. The user sets the mixing ratio, the size of the cuvette and the volume of samples. Color coded windows display calculated values and alert the user to out of range conditions. The estimated dead time is automatically displayed, and a pre-trigger is also available to be sure reliably detect the stationary state. This interface is ideal for routine mixing designs, occasional users, or students. advanced level The classic interface allows precise and unrestricted instrument programming. This is the ideal mode for multi-step sequences with a pre-washing phase, or for synchronizing with external devices (synchrotron lines for example). Estimated dead time is automatically calculated by the software. The classic mode is also suitable for freezequench and optical quench modes. For these applications the ageing time is also automatically calculated according to the user s parameters. global fitting/svd analysis Bio-Logic now provides SVD (Single Value Decomposition) analyzing tools with all new mixers. It is ideal to analyze data generated by diode array detectors, and multi-wavelength data generated by MOS-200/M, MOS-250 and MOS-450. It can also be used for global analysis of multi-concentration data set. It includes: c automatic estimation of number of vectors c fast SVD analysis c global fitting with residual analysis (2D and 3D) c levenberg-marquardt ans Simplex fit algorithms c large selection of kinetics model c import of data from clipboard or text files

optical coupling MOS-200/M Absorbance, fluorescence, chemiluminescence and 90 light scattering The perfect system for all basic rapid kinetics studies. It includes manual or motorized monochromator, dual light source, and high sensitivity photomultiplier. Triple detection available. Full automation for multi-wavelength experiments with automatic spectral reconstruction. 10 μs time resolution. Circular Dichroism and T-format anisotropy techniques with special accessories. MOS-450/AF-CD Absorbance, fluorescence, Circular Dichroism, LD, fluorescence anisotropy and 90 light scattering The most advanced kinetics and steady state spectrometer on the market with a double excitation monochromator and double light source. No purging needed in kinetics mode, and no need to handle lamps for operation. Time resolution to 10 μs. Bio-Kine control software allows full automation and multiwavelength experiments with automatic spectral reconstruction. MOS-DA Diode array spectrometer The fastest Diode array spectrometers on the market for UV, visible and near IR, with speed down to 0.8ms/ spectra. High quality 3D software interface. SVD analysis through Bio-Kine software. MOS-250 Absorbance, fluorescence and 90 light scattering in standard Fully automated with a built-in emission monochromator. The MOS-250 can be used for kinetics and steady state absorbance/ fluorescence (excitation/emission). Flexible connection options using fiber optic links.

customization The SFM-20 observation head was designed to allow easy coupling to external devices. Optional heads and adaptors have been designed for titration, neutron scattering, EPR, large and small angle X-ray, FT-IR, and conductimetry. Easy interfacing: c Fiber optic accessory c Single and double light links c Umbilical connection Specifications Drive mechanism independent stepping motors Number of syringes 2, user replaceable Number of stepping motors 2 Precision of stepping motors 10.4 nl per micro-step. Number of mixers 1 Mixer type Berger-Ball mixer Stop mechanism electro-valve Syringes Syringes material glass, gas tight Size of syringes 10 ml std., ( 5 ml, 2.5 ml and 1 ml optional ) Anaerobic operation standard Temperature control Temperature range -20 C to +80 C (standard) down to -90 C using cryo- option up to 200 C using high temperature umbilical and mixing head Temperature control water bath circulation Temperature probe optional PT100 allows direct reading of temperature in Bio-Kine Synchronization with detection Synchronization fully programmable; 5V TTL trigger in/out available Optical coupling fiber optics or direct attachment. Sample consumption Priming volume 50 μl per syringe Flow rate range 0.003 to 5.8 ml/s Mixing ratio fully variable from 1:1 to 1:40 Minimum injection volume 10-30 μl depending on syringe size in stopped-flow mode Minimum injection volume in titration mode 2 μl. Observation head Number of detection windows 3 Cuvette quartz; choice between 8 models light path from 0.8mm to 1 cm Optional capillary for X-ray measurements Minimal dead time 0.6 ms using micro-cuvette (0.8mm light path) < 1.5 ms using FC-08 Material PEEK, Viton Full solvent compatibility with optional Isolast O-rings Specifications subject to change without prior notice Bio-Logic, SAS 1, rue de l Europe 38640 CLAIX - France Tel.: +33 476 98 68 31 Fax: +33 476 98 69 09 www.bio-logic.info Compatible detection devices MOS-200 absorbance, fluorescence, 90 Light scattering, Circular dichroism, T-format anisotropy MOS-250 absorbance, fluorescence, 90 Light scattering MOS-DA diode array, absorbance MOS-450/AF-CD absorbance, fluorescence, 90 Light scattering, Circular dichroism, anisotropy (EMFA) General Dimensions Weight Communication Power PC configuration 200 x 140 x 802 mm 11 kg USB 110V-220V Pentium IV, Windows 2000, XP, Vista Upgrades Freeze quench ( EPR, Mossbauer, NMR, XAFS) EPR stopped-flow - conductivity XAFS head - neutron scattering head Titration - Optical quench Bio-Logic USA, LLC P.O.Box 30009 Knoxville TN 37930 - USA Tel.: +1 865 769 3800 Fax: +1 865 769 3801 Web: www.bio-logic.us Brochure released on November 2008-0810013 w w w. b i o - l o g i c. i n f o