MS BA01 Miniature Altimeter Module

Similar documents
MS BA01 Miniature Altimeter Module

MS BA03 Low Voltage Barometric Pressure Sensor

MS BA Miniature 30 bar Industrial Pressure Sensor

MS BA01 Miniature Altimeter Module

MS BA01 Miniature Altimeter Module

MS BA Micro Altimeter Module

PRELIMINARY. Resolution (OSR=8192) 0.2 mbar Accuracy 0 C to +40 C, mbar. 0 to 6 bar (2) Response time (1)

MS BA01 Variometer Module, with LCP cap

MS BA03 Low Voltage Barometric Pressure Sensor

MS BA07 Pressure sensor for harsh environment

PRELIMINARY. MS BA Ultra Small Gel Filled Pressure Sensor DESCRIPTION FEATURES

MS BA. Ultra Small Gel Filled Pressure Sensor SPECIFICATIONS

MS BA Miniature 30 bar Industrial Pressure Sensor

MS BA Miniature 14 bar Module

MS BA03 Barometric Pressure Sensor, with stainless steel cap

MS BA Miniature Altimeter and Diving Module

MS BA Miniature Altimeter Module

MS BA Miniature 30 bar Module

MS BA. Ultra Small Gel Filled Pressure Sensor SPECIFICATIONS

MS BA01. PHT Combination Sensor SPECIFICATIONS

MS BA Altimeter and diving pressure sensor

89BSD CALCULATION METHOD APPLICATION NOTE

MS BA01 PTH Fusion Sensor

MS4525HRD (High Resolution Digital)

MS4525HRD (High Resolution Digital) Integrated Digital Pressure Sensor (24-bit Σ ADC) Fast Conversion Down to 1 ms Low Power, 1 µa (standby < 0.15 µa)

ADVANCED INFORMATION MS4525HRD (High Resolution Digital)

TEMPERATURE COMPENSATION FOR MEAS PRESSURE SENSORS APPLICATION NOTE

KMT32B Magnetic Angle Sensor

Differential Pressure Sensor

ATtiny bit AVR Microcontroller with 16K Bytes In-System Programmable Flash DATASHEET APPENDIX B. Appendix B ATtiny1634 Specification at 125 C

STM1831. Voltage detector with sense input and external delay capacitor. Features. Applications

V N (8) V N (7) V N (6) GND (5)

KMT37 Angular Sensor DESCRIPTION

SPECIFICATION. Messrs. DATE 20 June, 2013 No. V AP4, AG4 Pressure Sensor

Temperature Compensation for MEAS Pressure Sensors

LV5217GP. Specifications. Bi-CMOS IC 3ch LED Driver. Absolute Maximum Ratings at Ta = 25 C. Ordering number : ENA0833A.

Conductive Polymer Aluminum Capacitors SMD (Chip), Low Impedance

Low Pressure Sensor Amplified Analog Output SM6295-BCM-S

ST2L Very low quiescent current dual voltage regulator. Description. Features. Applications

Small, Gauge Pressure Sensor

Small Gage Pressure Sensor

SERIALLY PROGRAMMABLE CLOCK SOURCE. Features

SN74LS175MEL. Quad D Flip Flop LOW POWER SCHOTTKY

Aluminum Capacitors SMD (Chip) Long Life Vertical

Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications

Aluminum Electrolytic Capacitors SMD (Chip) Long Life Vertical

Aluminum Capacitors SMD (Chip), High Temperature

3.2, Fast Switching Speed, +12 V / +5 V / +3 V / ± 5 V, 4- / 8-Channel Analog Multiplexers

Aluminum Electrolytic Capacitors SMD (Chip), High Temperature, Low Impedance, High Vibration Capability

Surface Mount Multilayer Ceramic Chip Capacitors for Ultra Small Commodity Applications

Miniature Electronically Trimmable Capacitor V DD. Maxim Integrated Products 1

with LSTTL Compatible Inputs

RT9403. I 2 C Programmable High Precision Reference Voltage Generator. Features. General Description. Ordering Information.

VFD- RoHS Compliant M0116MY-161LSBR2-1. User s Guide. (Vacuum Fluorescent Display Module) For product support, contact

SN74LS373, SN74LS374. Octal Transparent Latch with 3 State Outputs; Octal D Type Flip Flop with 3 State Output LOW POWER SCHOTTKY

NLSV2T Bit Dual-Supply Inverting Level Translator

Surface Mount Multilayer Ceramic Capacitors for Pulse Current Applications

POLE WHEELS. Where the shaft is very large a cost-effective alternative is to add a pole band (see following section).

High Power MicroClamp 1-Line ESD and Surge Protection

Surface Mount Multilayer Ceramic Chip Capacitors with Integrated Resistor for High Pulse Current Applications

HR-Z SERIES Mild Radiation Resistance LVDT

Surface Mount Multilayer Ceramic Chip Capacitors Prohibit Surface Arc-Over in High-Voltage Applications

I2 C Compatible Digital Potentiometers AD5241/AD5242

NTMFS4833NT3G. Power MOSFET. 30 V, 191 A, Single N-Channel, SO-8 FL Features

PART TEMP RANGE PIN-PACKAGE

Aluminum Electrolytic Capacitors SMD (Chip), High Temperature, Low Impedance High Vibration Capability

Surface Mount Multilayer Ceramic Chip Capacitors for High Q Commodity Applications

3.3 V 256 K 16 CMOS SRAM

Aluminum Electrolytic Capacitors SMD (Chip), Very Low Z, High Vibration Capability

KMT32B Magnetic Angle Sensor

Aluminum Electrolytic Capacitors Axial Miniature, Long-Life

SCB10H Series Pressure Elements PRODUCT FAMILY SPEFICIFATION. Doc. No B

Aluminum Capacitors SMD (Chip) Long Life Vertical

MMBV2101LT1 Series, MV2105, MV2101, MV2109, LV2209. Silicon Tuning Diodes pf, 30 VOLTS VOLTAGE VARIABLE CAPACITANCE DIODES

Description. Part numbers. AB version C version Output voltage LD2980ABM30TR LD2980ABM33TR LD2980CM33TR 3.3 V LD2980ABM50TR LD2980CM50TR 5.

SDT800-STR. Description. Features. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information

NV Electronically Programmable Capacitor

Medium Pressure Sensor Analog Output

RF Power Feed-Through Capacitors with Conductor Rod, Class 1 Ceramic

RF Power Feed-Through Capacitors with Conductor Rod, Class 1 Ceramic

Miniature SPI Digital Barometer

Solid Tantalum SMD Capacitors TANTAMOUNT, Hi-Rel COTS, Low ESR, Metal Case

Aluminum Capacitors SMD (Chip) Standard. Table 1

NL17SH02. Single 2-Input NOR Gate

Small Absolute Pressure Sensor

SM98A Harsh Media Backside Absolute Pressure Series

Surface Mount Multilayer Ceramic Chip Capacitors for Safety Certified Applications

Applications. Capacitance Tolerance G = ±2% J = ±5%

RF Power Plate Capacitors for Higher Voltages, Class 1 Ceramic

4-PIN PHOTOTRANSISTOR OPTOCOUPLERS

Precision 8-Ch/Dual 4-Ch Low Voltage Analog Multiplexers

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features.

onlinecomponents.com

LOW POWER SCHOTTKY. GUARANTEED OPERATING RANGES ORDERING INFORMATION PLASTIC N SUFFIX CASE 648

NCP ma, Wide Input Range, Voltage Regulator

2N7002. Features and Benefits. Product Summary. Description and Applications. Mechanical Data. Ordering Information (Note 5) Marking Information

CMOS ±5 V/+5 V/+3 V Triple SPDT Switch ADG633

STTH16R04CT. Ultrafast recovery diode. Main product characteristics. Features and benefits. Description. Order codes TO-220AB TO-220FPAB

PH5504A2NA1. Ambient Light Sensor DESCRIPTION FEATURES APPLICATIONS. R08DS0067EJ0100 Rev.1.00 Nov 05, 2012 DISCONTINUED

SP1008 Series 6pF 15kV Bidirectional Discrete TVS

Transcription:

SPECIFICATIONS High resolution module, 20 cm Fast conversion down to 0.5 ms Low power, 0.6 µa (standby < 0.15 µa at 25 C) Integrated digital pressure sensor (24 bit ΔΣ AC) Supply voltage 1.8 to 3.6 V Operating range: 300 to 1200 mbar, -40 to +85 C Extended pressure range: 10 to 2000 mbar I 2 C interface No external components (Internal oscillator) Excellent long term stability Sealing designed for 2.5 x 1mm O-ring The MS5805-02A is a new generation of high-resolution altimeter sensors from MEAS Switzerland with I 2 C bus interface. It is optimized for altimeters and variometers with an altitude resolution of 20 cm. The sensor module includes a high-linearity pressure sensor and an ultra low power 24 bit ΔΣ AC with internal factory-calibrated coefficients. It provides a precise digital 24 it pressure and temperature value and different operation modes that allow the user to optimize for conversion speed and current consumption. A high-resolution temperature output allows the implementation of an altimeter/thermometer function without any additional sensor. The MS5805-02A can be interfaced to virtually any microcontroller. The communication protocol is simple, without the need of programming internal registers in the device. This new sensor module generation is based on leading MEMS technology and latest benefits from MEAS Switzerland proven experience and know-how in high volume manufacturing of altimeter modules, which have been widely used for over a decade. The sensing principle employed leads to very low hysteresis and high stability of both pressure and temperature signal. SENSOR SOLUTIONS ///MS5805-02A01 Page 1 06/2017

FEATURES FIEL OF APPLICATION Mobile altimeter / barometer systems ike computers Adventure or multi-mode watches Variometers ataloggers TECHNICAL ATA Sensor Performances (V = 3 V) Pressure Min Typ Max Unit Range 10 2000 mbar AC 24 bit Resolution (1) Accuracy 25 C, 750 to 1100 mbar Accuracy -20 C to + 85 C, 300 to 1200 mbar (2) Response time 0.35 / 0.19 / 0.11 / 0.06 / 0.03 / 0.02 mbar -2 +2 mbar -4 +4 mbar 0.5 / 1.1 / 2.1 / 4.1 / 8.22 / 16.44 Long term stability ±1 mbar/yr Temperature Min Typ Max Unit Range -40 +85 C Resolution <0.01 C Accuracy -1 +1 C Notes: (1) Oversampling Ratio: 256 / 512 / 1024 / 2048 / 4096/ 8192 (2) With autozero at one pressure point ms FUNCTIONAL LOCK IAGRAM V SENSOR +IN I 2 C us Interface SA -IN AC dig. Filter SCL SGN Sensor Interface IC Memory (PROM) 112 bits GN SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 2

PERFORMANCE SPECIFICATIONS ASOLUTE MAXIMUM RATINGS Parameter Symbol Conditions Min. Typ. Max Unit Supply voltage V -0.3 +3.6 V Storage temperature TS -20 +85 C Overpressure Pmax 5 bar Maximum Soldering Temperature Tmax 40 sec max 250 C ES rating Human ody Model -2 +2 kv Latch up JEEC standard No 78-100 +100 ma ELECTRICAL CHARACTERISTICS Parameter Symbol Conditions Min. Typ. Max Unit Operating Supply voltage V 1.8 3.0 3.6 V Operating Temperature T -40 +25 +85 C Supply current (1 sample per sec.) I OSR 8192 4096 2048 1024 512 256 20.09 10.05 5.02 2.51 1.26 0.63 Peak supply current during conversion 1.25 ma Standby supply current at 25 C (V = 3.0 V) 0.01 0.1 µa V Capacitor From V to GN 100 470 nf µa ANALOG IGITAL CONVERTER (AC) Parameter Symbol Conditions Min. Typ. Max Unit Output Word 24 bit Conversion time tc OSR 8192 4096 2048 1024 512 256 16.44 8.22 4.13 2.08 1.06 0.54 ms SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 3

PERFORMANCE SPECIFICATIONS (CONTINUE) PRESSURE OUTPUT CHARACTERISTICS (V = 3 V, T = 25 C UNLESS OTHERWISE NOTE) Parameter Conditions Min. Typ. Max Unit Operating Pressure Range Prange Full Accuracy 300 1200 mbar Extended Pressure Range Pext Linear Range of AC 10 2000 mbar Absolute Accuracy, no autozero at 25 C, 750..1100 mbar -2 +2 mbar Absolute Accuracy, autozero at one pressure point 300..1200 mbar at 25 C 300..1200 mbar, -20..85 C Maximum error with supply voltage V = 1.8 V 3.6 V ±2.5 mbar Long-term stability ±1 mbar/yr Resolution RMS Reflow soldering impact OSR 8192 4096 2048 1024 512 256 IPC/JEEC J-ST-020C (See application note AN808 on http://meas-spec.com) -2-4 0.02 0.03 0.06 0.11 0.19 0.35 +2 +4 mbar mbar -1.5 mbar Recovering time after reflow (1) 5 days (1) Time to recover at least 66% of the reflow impact. TEMPERATURE OUTPUT CHARACTERISTICS (V = 3 V, T = 25 C UNLESS OTHERWISE NOTE) Parameter Conditions Min. Typ. Max Unit at 25 C -1 +1 Absolute Accuracy C -20..85 C -2 +2 Maximum error with supply V = 1.8 V 3.6 V ±0.3 C voltage Resolution RMS (to confirm with measured values) OSR 8192 4096 2048 1024 512 256 0.002 0.003 0.004 0.006 0.009 0.012 C SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 4

PERFORMANCE SPECIFICATIONS (CONTINUE) IGITAL INPUTS (SA, SCL) Parameter Symbol Conditions Min. Typ. Max Unit Serial data clock SCL 400 khz Input high voltage VIH 80% V 100% V V Input low voltage VIL 0% V 20% V V Input leakage current IGITAL OUTPUTS (I 2 C, OUT) Ileak25 C Ileak85 C at 25 c 0.1 µa Parameter Symbol Conditions Min. Typ. Max Unit Output high voltage VOH Isource = 0.6 ma 80% V 100% V V Output low voltage VOL Isink = 0.6 ma 0% V 20% V V Load capacitance CLOA 16 pf SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 5

TYPICAL PERFORMANCE CHARACTERISTICS PRESSURE AN TEMPERATURE ERROR VS PRESSURE AN TEMPERATURE (TYPICAL VALUES) PRESSURE AN TEMPERATURE ERROR VS POWER SUPPLY (TYPICAL VALUES) SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 6

FUNCTIONAL ESCRIPTION V SENSOR +IN I 2 C us Interface SA -IN AC dig. Filter SCL SGN Sensor Interface IC Memory (PROM) 112 bits GN GENERAL Figure 1: lock diagram of MS5805-02A The MS5805-02A consists of a piezo-resistive sensor and a sensor interface integrated circuit. The main function of the MS5805-02A is to convert the uncompensated analogue output voltage from the piezo-resistive pressure sensor to a 24-bit digital value, as well as providing a 24-bit digital value for the temperature of the sensor. FACTORY CALIRATION Every module is individually factory calibrated at two temperatures and two pressures. As a result, 6 coefficients necessary to compensate for process variations and temperature variations are calculated and stored in the 112- bit PROM of each module. These bits (partitioned into 6 coefficients) must be read by the microcontroller software and used in the program converting 1 and 2 into compensated pressure and temperature values. COMMUNICATION INTERFACE The MS5805-02A has been built with I 2 C serial interface. Module ref Mode Pins used MS5805-02A01 I 2 C SA, SCL The external microcontroller clocks in the data through the input SCL (Serial CLock) and SA (Serial Ata). The sensor responds on the same pin SA which is bidirectional for the I 2 C bus interface. So this interface type uses only 2 signal lines and does not require a chip select. SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 7

PRESSURE AN TEMPERATURE CALCULATION Start Maximum values for calculation results: P MIN = 10mbar P MAX = 2000mbar T MIN = -40 C T MAX = 85 C T REF = 20 C Variable escription Equation Convert Read calibration data data into (factory coefficients calibrated) (see from bit pattern PROMof W1 to W4) Recommended variable type C1 Pressure sensitivity SENS T1 unsigned int 16 16 0 65535 46372 C2 Pressure offset OFF T1 unsigned int 16 16 0 65535 43981 C3 Temperature coefficient of pressure sensitivity TCS unsigned int 16 16 0 65535 29059 C4 Temperature coefficient of pressure offset TCO unsigned int 16 16 0 65535 27842 C5 Reference temperature T REF unsigned int 16 16 0 65535 31553 C6 Temperature coefficient of the temperature TEMPSENS unsigned int 16 16 0 65535 28165 Size [1] [bit] min Value max Example / Typical Read Read digital digital pressure and and temperature data data 1 igital pressure value unsigned int 32 24 0 16777216 6465444 2 igital temperature value unsigned int 32 24 0 16777216 8077636 Calculate temperature dt [2] ifference between actual and reference temperature dt = 2 - T REF = 2 - C5 * 2 8 signed int 32 25-16776960 16777216 68 Actual temperature (-40 85 C with 0.01 C resolution) 2000 TEMP signed int 32 TEMP = 20 C + dt *TEMPSENS = 2000 + dt * C6 / 2 23 41-4000 8500 = 20.00 C Calculate temperature compensated pressure OFF SENS P Offset at actual temperature [3] OFF = OFF T1 + TCO * dt = C2 * 2 17 + (C4 * dt ) / 2 6 signed int 64 41-17179344900 25769410560 5764707214 Sensitivity at actual temperature [4] SENS = SENS T1 + TCS * dt = C1 * 2 16 + (C3 * dt ) / 2 7 signed int 64 41-8589672450 12884705280 3039050829 Temperature compensated pressure (10 1200mbar with 0.01mbar resolution) P = 1 * SENS - OFF = (1 * SENS / 2 21 - OFF) / 2 15 signed int 32 58 1000 120000 110002 = 1100.02 mbar Pressure and temperature value first order Notes [1] [2] [3] [4] Maximal size of intermediate result during evaluation of variable min and max have to be defined min and max have to be defined min and max have to be defined Figure 2: Flow chart for pressure and temperature reading and software compensation. SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 8

SECON ORER TEMPERATURE COMPENSATION The results of the last first order calculation are entered in the following chart to obtain the pressure and temperature compensated with the 2 nd order: P2 and TEMP2. Pressure and temperature value first order Yes TEMP<20 C No Low temperature Low temperature Ti = 11 dt 2 / 2 35 OFFi = 31 (TEMP 2000) 2 / 2 3 SENSi = 63 (TEMP 2000) 2 / 2 5 Calculate pressure and temperature 2 nd order OFF2 = OFF - OFFi SENS2 = SENS - SENSi TEMP2 = (TEMP Ti) / 100 P2 = (( 1 * SENS2 / 2 21 OFF2 ) / 2 15 ) / 100 [ C] [mbar] Figure 3: Flow chart for pressure and temperature to the optimum accuracy. SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 9

I 2 C INTERFACE COMMANS The MS5805-02A has only five basic commands: 1. Reset 2. Read PROM (112 bit of calibration words) 3. 1 conversion 4. 2 conversion 5. Read AC result (24 bit pressure / temperature) Each I 2 C communication message starts with the start condition and it is ended with the stop condition. The MS5805-02A address is 1110110x (write : x=0, read : x=1). Size of each command is 1 byte (8 bits) as described in the table below. After AC read commands the device will return 24 bit result and after the PROM read 16bit result. The address of the PROM is embedded inside of the PROM read command using the a2, a1 and a0 bits. Command byte hex value it number 0 1 2 3 4 5 6 7 it name PRO CO - Typ Ad2/ Ad1/ Ad0/ Stop M NV Os2 Os1 Os0 Command Reset 0 0 0 1 1 1 1 0 0x1E Convert 1 (OSR=256) 0 1 0 0 0 0 0 0 0x40 Convert 1 (OSR=512) 0 1 0 0 0 0 1 0 0x42 Convert 1 (OSR=1024) 0 1 0 0 0 1 0 0 0x44 Convert 1 (OSR=2048) 0 1 0 0 0 1 1 0 0x46 Convert 1 (OSR=4096) 0 1 0 0 1 0 0 0 0x48 Convert 1 (OSR=8192) 0 1 0 0 1 0 1 0 0x4A Convert 2 (OSR=256) 0 1 0 1 0 0 0 0 0x50 Convert 2 (OSR=512) 0 1 0 1 0 0 1 0 0x52 Convert 2 (OSR=1024) 0 1 0 1 0 1 0 0 0x54 Convert 2 (OSR=2048) 0 1 0 1 0 1 1 0 0x56 Convert 2 (OSR=4096) 0 1 0 1 1 0 0 0 0x58 Convert 2 (OSR=8192) 0 1 0 1 1 0 1 0 0x5A AC Read 0 0 0 0 0 0 0 0 0x00 PROM Read 1 0 1 0 Ad2 Ad1 Ad0 0 0xA0 to 0xAE Figure 4: Command structure SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 10

RESET SEQUENCE The Reset sequence shall be sent once after power-on to make sure that the calibration PROM gets loaded into the internal register. It can be also used to reset the device PROM from an unknown condition. The reset can be sent at any time. In the event that there is not a successful power on reset this may be caused by the SA being blocked by the module in the acknowledge state. The only way to get the MS5805 to function is to send several SCLs followed by a reset sequence or to repeat power on reset. 1 1 1 0 1 1 0 0 0 0 0 0 1 1 1 1 0 0 evice Address command S evice Address W A cmd byte A P From Master S = Start Condition W = Write A = Acknowledge From Slave P = Stop Condition R = Read N = Not Acknowledge Figure 5: I 2 C Reset Command PROM REA SEQUENCE The read command for PROM shall be executed once after reset by the user to read the content of the calibration PROM and to calculate the calibration coefficients. There are in total 7 addresses resulting in a total memory of 112 bit. Addresses contains factory data and the setup, calibration coefficients, the serial code and CRC. The command sequence is 8 bits long with a 16 bit result which is clocked with the MS first. The PROM Read command consists of two parts. First command sets up the system into PROM read mode. The second part gets the data from the system. 1 1 1 0 1 1 0 0 0 1 0 1 0 0 1 1 0 0 evice Address command S evice Address W A cmd byte A P From Master S = Start Condition W = Write A = Acknowledge From Slave P = Stop Condition R = Read N = Not Acknowledge Figure 6: I 2 C Command to read memory address= 011 1 1 1 0 1 1 0 1 0 X X X X X X X X 0 X X X X X X X X 0 evice Address data data S evice Address R A Memory bit 15-8 A Memory bit 7-0 N P From Master S = Start Condition W = Write A = Acknowledge From Slave P = Stop Condition R = Read N = Not Acknowledage Figure 7: I 2 C answer from MS5805 SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 11

CONVERSION SEQUENCE The conversion command is used to initiate uncompensated pressure (1) or uncompensated temperature (2) conversion. After the conversion, using AC read command the result is clocked out with the MS first. If the conversion is not executed before the AC read command, or the AC read command is repeated, it will give 0 as the output result. If the AC read command is sent during conversion the result will be 0, the conversion will not stop and the final result will be wrong. Conversion sequence sent during the already started conversion process will yield incorrect result as well. A conversion can be started by sending the command to MS5805. When command is sent to the system it stays busy until conversion is done. When conversion is finished the data can be accessed by sending a Read command, when an acknowledge is sent from the MS5805, 24 SCL cycles may be sent to receive all result bits. Every 8 bits the system waits for an acknowledge signal. 1 1 1 0 1 1 0 0 0 0 1 0 0 1 0 0 0 0 evice Address command S evice Address W A cmd byte A P From Master S = Start Condition W = Write A = Acknowledge From Slave P = Stop Condition R = Read N = Not Acknowledge Figure 8: I 2 C command to initiate a pressure conversion (OSR=4096, typ=1) 1 1 1 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 evice Address command S evice Address W A cmd byte A P From Master S = Start Condition W = Write A = Acknowledge From Slave P = Stop Condition R = Read N = Not Acknowledge Figure 9: I 2 C AC read sequence 1 1 1 0 1 1 0 1 0 X X X X X X X X 0 X X X X X X X X 0 X X X X X X X X 0 evice Address data data data S evice Address R A ata 23-16 A ata 15-8 A ata 7-0 N P From Master S = Start Condition W = Write A = Acknowledge From Slave P = Stop Condition R = Read N = Not Acknowledge Figure 10: I 2 C answer from MS5805 SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 12

CYCLIC REUNANCY CHECK (CRC) MS5805-02A contains a PROM memory with 112-it. A 4-bit CRC has been implemented to check the data validity in memory. The C code example below describes the CRC calculation which is stored on 12 to 15 in the first PROM word. A d d 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 0 CRC Factory defined 1 C1 2 C2 3 C3 4 C4 5 C5 6 C6 3 Figure 11: Memory PROM mapping 2 1 0 C Code example for CRC-4 calculation: unsigned char crc4(unsigned int n_prom[]) { int cnt; unsigned int n_rem=0; unsigned char n_bit; // n_prom defined as 8x unsigned int (n_prom[8]) // simple counter // crc reminder } n_prom[0]=((n_prom[0]) & 0x0FFF); // CRC byte is replaced by 0 n_prom[7]=0; // Subsidiary value, set to 0 for (cnt = 0; cnt < 16; cnt++) // operation is performed on bytes { // choose LS or MS if (cnt%2==1) n_rem ^= (unsigned short) ((n_prom[cnt>>1]) & 0x00FF); else n_rem ^= (unsigned short) (n_prom[cnt>>1]>>8); for (n_bit = 8; n_bit > 0; n_bit--) { if (n_rem & (0x8000)) n_rem = (n_rem << 1) ^ 0x3000; else n_rem = (n_rem << 1); } } n_rem= ((n_rem >> 12) & 0x000F); // final 4-bit reminder is CRC code return (n_rem ^ 0x00); SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 13

APPLICATION CIRCUIT The MS5805-02A is a circuit that can be used in conjunction with a microcontroller in mobile altimeter applications. It is designed for low-voltage systems with a supply voltage of 3 V. Figure 12: Typical application circuit with I 2 C protocol communication SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 14

PIN CONFIGURATION Figure 13: pin configuration Pin Name Type Function 1 V P Positive supply voltage 2 SCL I Serial data Clock 3 SA IO I 2 C data IO 4 GN P Ground EVICE PACKAGE OUTLINE Notes: Figure 14: MS5805-02A package outlines (1) imensions in mm (2) Interpret im and tolerance per ASME Y14.5M - 1994 (3) Angular dimensions ± 0.3 (4) Hole locations ± 0.1 (4) Linear dimension ± 0.1 (5) Cap centering ± 0.15 from center of the ceramic SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 15

RECOMMENE PA LAYOUT Pad layout for bottom side of the MS5805 soldered onto printed circuit board. Figure 15: MS5805 pad layout SHIPPING PACKAGE Figure 16: Tape and Reel SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 16

MOUNTING AN ASSEMLY CONSIERATIONS SOLERING Please refer to the application note AN808 available on our website for all soldering issues. CONNECTION TO PC The package outline of the module allows the use of a flexible PC for interconnection. This can be important for applications in watches and other special devices. CLEANING The MS5805-02A has been manufactured under cleanroom conditions. It is therefore recommended to assemble the sensor under class 10 000 or better conditions. Should this not be possible, it is recommended to protect the sensor opening during assembly from entering particles and dust. To avoid cleaning of the PC, solder paste of type no-clean shall be used. Cleaning might damage the sensor! ES PRECAUTIONS The electrical contact pads are protected against ES up to 2 kv HM (human body model). It is therefore essential to ground machines and personnel properly during assembly and handling of the device. The MS5805-02A is shipped in antistatic transport boxes. Any test adapters or production transport boxes used during the assembly of the sensor shall be of an equivalent antistatic material. ECOUPLING CAPACITOR Particular care must be taken when connecting the device to the power supply. A 100 nf ceramic capacitor must be placed as close as possible to the MS5805-02A V pin. This capacitor will stabilize the power supply during data conversion and thus, provide the highest possible accuracy. SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 17

ORERING INFORMATION Part Number / Art. Number Product elivery Form MS580502A01-50 MS5805-02A T&R Tape& reel TOP-UP NORTH AMERICA Measurement Specialties, Inc., a TE Connectivity company Tel: 800-522-6752 Email: customercare.frmt@te.com EUROPE Measurement Specialties (Europe), Ltd., a TE Connectivity Company Tel: 800-440-5100 Email: customercare.bevx@te.com ASIA Measurement Specialties (China) Ltd., a TE Connectivity company Tel: 0400-820-6015 Email: customercare.shzn@te.com TE.com/sensorsolutions Measurement Specialties, Inc., a TE Connectivity company. Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity s obligations shall only be as set forth in TE Connectivity s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. 2015 TE Connectivity Ltd. family of companies All Rights Reserved. SENSOR SOLUTIONS /// MS5805-02A01 06/2015 Page 18