Shorten your Time-to-Result

Similar documents
S2 PICOFOX. Innovation with Integrity. Benchtop TXRF Spectrometer TXRF

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF

Trace Element Analysis: Time and Cost Savings with TXRF. Bruker AXS Microanalysis GmbH Berlin, Germany

Cost-effective Trace Element Analysis with TXRF

TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER

IDENTIFICATION TESTS FOR DURACOR TABLETS

Basic Digestion Principles

I. SCOPE AND APPLICATION

CATALASE ACTIVITY ASSAY KIT KB test (96 well plate)

Sample Preparation of Electronic Device Components for Hexavalent Chromium Analysis by IEC Method :2017

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

Protocol Particle size distribution by centrifugal sedimentation (CPS)

MyBioSource.com. Na + /K + ATPase Microplate Assay Kit. User Manual. Catalog # Detection and Quantification of Na + /K + ATPase activity in Urine,

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Trace elemental analysis of challenging samples in the mining and resource industry. Bruker Nano GmbH, Berlin, Germany April 8, 2015

S8 TIGER Series 2 for ASTM D 6443

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Biology Unit 2, Structure of Life, Lab Activity 2-2

USGS Troy WSC Laboratory Inductively Coupled Plasma- NH4Cl Soil Extracts SOP 425 Jordan Road Rev. No. 2.0 Troy, NY Date: 03/16/2012 Page 1 of 7

ESPRIT Feature. Innovation with Integrity. Particle detection and chemical classification EDS

National standard of People s Republic of China

Determining the Concentration of a Solution: Beer s Law

Component Product # Product # Cell Lysis Reagent 100 ml 500 ml Product Insert 1 1

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Exp 1 Column Chromatography for the Isolation of Excedrin Components. Reading Assignment: Column Chromatography, TLC (Chapter 18)

Scope: Materials: Labeled 1.5 ml or 2 ml Eppendorf tubes Appropriate pipette tips (see Table 1) Labeled LC vials

Bovine FSH(Follicle Stimulating Hormone) ELISA Kit

PRELIMINARY ACTIVITY FOR

5. SEPARATION OF MIXTURES, PURIFICATION OF SOLIDS Objectives

user manual blotting Hoefer PR648 Slot blot manifold um PR648-IM/Rev.F0/08-12

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

IAEA-TECDOC-9SO. Sampling, storage

Substances and Mixtures:Separating a Mixture into Its Components

AP Chemistry Lab #5- Synthesis and Analysis of Alum (Big Idea 1 & 2)

Basic Analytical Techniques, Calorimeter, and Conductivity Meter

General Chemistry I CHEM-1030 Laboratory Experiment No. 2 Physical Separation Techniques

Introduction to Work in Laboratory

NAD/NADH Microplate Assay Kit User Manual

POWER + FLEXIBILITY IN ELEMENTAL ANALYSIS

GRIGNARD REACTION Synthesis of Benzoic Acid

Practical 1 Procedure Iron by Titrimetry

Not Just for Paint Chips Anymore. High Throughput, Open Vessel Microwave Digestion of Matrices Requiring Moderate Conditions

CHEM 334 Quantitative Analysis Laboratory

Experiment 24. Chemical recycling of poly(ethylene) terephthalate (PET)

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

The Synthesis and Analysis of Aspirin

The solution for all of your

Uranium from water sample

Adenosine Deaminase Assay (ADA) Kit Instructions

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

Sampling and DNA Extraction from Wastewater Activated Sludge Standard Protocol

Test Method: CPSC-CH-E

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Chemical Reactions: The Copper Cycle

mag nanogram kit Description Kit uses

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

Guide to ph Analysis.

applied as UV protective films

COMPANY WITH QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV GL = ISO 9001 = Complement CH50 Assay. Kit Insert

N) manual. Biomaster Operating manual

DEVELOP YOUR LAB, YOUR WAY

Bio 120 Lab 5: Quantitative Analysis

Rat Uric acid(uric acid) ELISA Kit

Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

Microwave Extraction Provides More Reliable Analysis of High Mass Unit Additives

Preparing the sample for determination of Viability

URANIUM IN SOIL. Analytical Procedure (2 GRAM SAMPLE) 1. SCOPE

NOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation.

The analysis of organic acid content of additives, premix, feed, and water.

Application Note PB 401. Improve HPLC Sample Preparation in an Analytical Laboratory A New Automated Sample Preparation Process

The. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples

TrioMol Isolation Reagent

TrioMol Isolation Reagent

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF

INTERNATIONAL CHEMISTRY TESTING. 258 Main Street- Suite 311- Milford, MA Tel: Fax:

INSTITUT FÜR ANGEWANDTE LABORANALYSEN GMBH. First-Beer Magnetic DNA Kit. Extraktion von Hefe- und Bakterien-DNA aus Bier und anderen Getränken

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

USGS District Laboratory, Troy, NY Dissolved Inorganic Carbon Analysis Standard Operating Procedure

Quantitative analysis of Na, K and Ca in milk and yogurt using the MH-5000 Ultra Compact Elemental Analyzer

Scientific Observations and Reaction Stoichiometry: The Qualitative Analysis and Chemical Reactivity of Five White Powders

Chemistry MultiMeasure Sensor PS-2170

425 Jordan Road SOP. No. 10 Rev. No. 1.3 Troy, NY Date: 03/14/2012 Page 1 of 7

Determination the elemental composition of soil samples

Automating Wet Chemical Analysis. William Lipps Market Specialist for Water Analyzer Products December 11, 2008

QAM-I-116 Preparation of Labware

Soil Sample Preparation Protocol (Modified from Faegri and Iversen 1 ; Moore and Webb 2 protocols)

ab Carrez Clarification Reagent Kit

Instrumental Technique: Cuvette. Md Rabiul Islam

Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051

Chromatography: Thin-Layer Chromatography (TLC) & Column Chromatography

CfE Higher Chemistry. Unit 3: Chemistry in Society. Chemical Analysis as part of quality control

Operating Instructions for Ammonium ISE Specifications

AgraQuant Plus Pistachio Sandwich ELISA

Basic Equipments and Instruments used in Chemistry laboratory: Balance: It is an instrument for measuring mass.

Method 8326 (0.006 to mg/l Al 3+ ) Powder Pillows

Determination of the inorganic ion composition of standing surface water

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

Mag-Bind Soil DNA Kit. M preps M preps M preps

Transcription:

Shorten your Time-to-Result Effective quality and process control requires the shortest time-to-result possible. This is the time needed from sampling to the final quantitative result. Any advantage results in: Higher sample throughput Stable industrial processes due to immediate feedback Constant high product quality The sample preparation steps required for most common sample types prior to a TXRF analysis were shown on the previous pages. Avoiding several preparation steps will shorten your time-to-result significantly as shown on the chart below. Digestion is not required for most samples types. The instrument is calibrated ex works, which will save up to 30% of your daily work time. The one-point quantification procedure with an internal standard gives accurate results automatically - effort for trainings and lab standardization will be minimized. Comparison of the total process time for different analytical methods milling resuspending drying measurement homogenisation acid digestion matrix adaption measurement

All configurations and specifications are subject to change without notice. Order No. DOC-L81-EXS035, Rev. 1.2. 2015 Bruker Nano GmbH. In the End - Consumables A bottomless pit The operation of any AAS or ICP spectrometer requires the use of carrier and burning gas, standards for regular calibration and cooling water. Even at average sample throughput the costs for all consumables will sum up to about 25 % of the purchase price of an ICP-OES and 50 % of an AAS per year. With TXRF expenses for consumables will be reduced dramatically. Inexpensive one-element standards will last for hundreds of measurements. Highest sensitivity will be achieved when using quartz sample carriers, which can be reused for more than 100 measurements. The following pictures explain the simple cleaning procedure of the carriers. Carrier disk cleaning Remove sample material manually with a lintfree wipe soaked with acetone. Plug quartz discs in a cleaning cassette (incl. in delivery). Place cleaning cassette in a 1 litre glass beaker filled with 10 % nitric acid and simmer for 2 hours on a heating plate. Rinse the cleaning cassette with distilled water. Place it in a beaker filled with ultrapure water. Heat the beaker in a microwave oven for about 5 minutes at 800 W. Dry the carriers in a laboratory oven for 20 minutes at 80 C. Run a blank measurement of the cleaned discs for about 180 s. Done! Store the clean carriers carefully without risk of contamination. Authors Armin Gross, Hagen Stosnach, Bruker Nano GmbH, Berlin, Germany Bruker Nano GmbH Berlin Germany Phone +49 (30) 670990-0 Fax +49 (30) 670990-30 info.bna@bruker.com Bruker AXS Inc. Madison, WI USA Phone +1 (608) 276-3000 Fax +1 (608) 276-3006 info.baxs@bruker.com www.bruker.com www.s2picofox.com

S2 PICOFOX Solid sample Liquid sample Preparation on carrier Time-to-result Lab Report XRF 435 S2 PICOFOX Why Wait for Sample Prep! Shortest Time-to-Result through TXRF Introduction The accurate chemical analysis of any sample requires a time-consuming procedure with a number of steps depending on the type of sample: Sampling, filtration, grinding, homogenization, chemical stabilization Digestion and/or extraction with hazardous chemicals, dilution or enrichment, pellet pressing, melting Instrument setup, calibration of the analytical instrument Measurement, data aquisition Data evaluation, reporting, data export, archiving Each step raises costs for materials and labour, increases the risk of analytical errors and contaminations and requires operator training and instrument maintenance. Simplify your sample preparation with TXRF Total Reflection X-ray Fluorescence (TXRF) analysis is a versatile analytical method, which is suitable for the multielement analysis of different kinds of sample types. For most analytical tasks sample digestion can be avoided and sample preparation can be reduced to a few simple steps. The operation of the instrument does not require any consumables or replacement parts. Due to a factory-built one time calibration the spectrum evaluation and quantification is fast and simple. This report explains the easy procedures required for the preparation of different sample types. Furthermore, it highlights the short time-to-result achieved by the TXRF method.

Why Wait for Sample Prep! Just a few steps are required for the sample preparation prior to an elemental analysis with TXRF. The preparation procedures for the most common sample types are described here in detail. A variety of samples can be applied directly or after a simple dilution step: Liquids: tap water, freshwater, beverages, urine and other body fluids, organic solvents. Suspensions and matrix rich liquids: sewage, sea water, whole blood, blood serum, tissue homogenates, dyes. Solid samples can be quantitatively analyzed after grinding and resuspending. Time-consuming digestion with hazardous chemicals can be avoided. Solids, powders: soils, sediments, tablets, polymers, food, lubricants, catalyzer, glass splinter, ashes. Direct application of particles allows a standardless analysis of the relative element composition. Particles: Nanoparticles, contaminations, proteins, gunshot residues. In addition, procedures for the preparation of samples like filters, wafer pieces, thin films, aerosols etc. are available on request. Suspensions Solid samples Fill powder in an agate mortar or micro mill Grind or mill carefully (e.g. Retsch MM400) Weigh about 20 to 50 mg, note exact amount z Direct analysis of liquids, suspensions and particles z Precalibrated instrument - simple quantification by internal standardization z Save method - almost no hazardous chemicals needed z Low cost of operation - no media or consumables required

Liquid samples Micro reaction tube with liquid sample Add internal standard Homogenize carefully Pipette 5 to 20 µl on carrier Tube with raw suspension Dilute sample with distilled water Add internal standard Homogenize carefully Pipette 5 to 20 µl on carrier Transfer quantitatively to a tube Suspend in 1 to 2 ml detergent solution Add standard Homogenize carefully Pipette 5 to 20 µl on carrier Particles Dab vacuum grease on carrier Pick-up some particles with (glass) rod Drop particles on grease

TXRF spectrum Dry 10 min Measure 5-15 min Dry through heat or vacuum Load the instrument Table with quantitative results Create PDF file or print report Export data for archiving, LIMS etc.