Test Report. Report Number: L16019 Date: Mar 21, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Similar documents
Test Report. Report Number: L16056 Date: Jun 14, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L16079 Date: Oct 12, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L15097 Date: Jul 29, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L15098 Date: Jul 28, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L15021 Date: Mar 16, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L14121 Date: Nov 20, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L14064 Date: Sep 30, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L14127 Date: Dec 9, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L14062 Date: Sep 22, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L14139 Date: Jul 21, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.

GM LIGHTING 9830 W 190th St, Torrance, CA 90503

Photometric Test Report

Number Eight Lighting Company MPT2-HI-R-6-BK/40/DIM1-M-1000

Number Eight Lighting Company MPT2-HI-R-6-BK/25/DIM1-M-1400

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

Number Eight Lighting Company. 804/J2-WD-25/DIM WD with FS-P-1-WH trim

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

LM-79 Report TEST REPORT NO.M037D

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

Beachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI

Beachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Maxlite Jersey Blvd Rancho Cucamonga, CA Electrical and Photometric tests as required by the IESNA test standards.

LM-79 Report TEST REPORT NO. L523A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

Transcription:

Test Report Report Number: L1619 Date: Mar 21, 216 Issued by: 151 Route 34 South, Farmingdale, NJ 2 Test of one CID1 Battery Backup Linear Unit manufacturer: Dialight Corporation Unit model number: LSC3C4MEGEX Issued to: Dialight Corporation 151 Route 34 South, Farmingdale, NJ 2 Tests performed: Photometric characterization and temperature measurement per the described standards. Dates of test: March 9, 216 through March 11, 216 Standards used: All tests are performed in accordance with procedures and guidelines prescribed by the American National Standards Institute (ANSI) or Illuminating Engineering Society of North America (IES): IES LM-9:28: Electrical and Photometric Measurements of Solid-State Lighting Products ANSI/UL 1598:28: Underwriters Laboratories Inc. Standard for Safety: Luminaires ENERGY STAR Manufacturer's Guide for Qualifying Solid State Lighting Luminaires Version 2.1 Description of sample: Sample Number: L1619 Manufacturer: Dialight Corporation Product Name: CID1 Battery Backup Linear Description: CID1 Battery Backup Linear Model Number: LSC3C4MEGEX Report Number: L1619 Page 1 of 9

Report Summary Sample number L1619 Dialight unit model number LSC3C4MEGEX Photograph(s) of sample: Summary of Results: *Photographs not to scale. For reference only. Integrating Sphere Goniophotometer Luminous Flux: 621 (lumens) 683 (lumens) Electrical Power: 8. 8.6 Luminous Efficacy: 95.38 (lumens/w) 95.33 (lumens/w) Electrical Measurements: Input Power (2VAC): Power Factor (2VAC): Current ATHD % (2VAC): Input Power (12VAC): Power Factor (12VAC): Current ATHD % (12VAC): Color Measurements: Correlated Color Temperature (CCT): Color Rendering Index (CRI): Chromaticity Coordinate (x): Chromaticity Coordinate (y): Chromaticity Coordinate (u'): Chromaticity Coordinate (v'): DUV: Temperature Measurements: In Situ LED Source Temperature: 8..81 16.84 9..988 11.95 488 1.4.349.359.211.326.21 49.5 Report Number: L1619 Page 2 of 9

Spectral Power Test Results: Integrating Sphere Results include unit color, flux, efficacy and electrical power for sample number L1619. Dialight unit model number LSC3C4MEGEX Test Conditions: Electrical Measurements: Photometric measurements: Ambient Temperature: 25 ± 1 Input Voltage: 12 (VAC) Input Current:.332 (A) Input Power: 8. Input Power Factor:.81 Current ATHD: 16.84 (%) Luminous Flux: 621 Luminous Efficacy: 95.4 Correlated Color Temperature (CCT): 488 CRI -Ra: 1.4 CRI -R9: -21.3 DUV:.21 CIE Coordinate (x):.349 CIE Coordinate (y):.359 CIE Coordinate (u'):.211 CIE Coordinate (v'):.326 (lumens) (lumens/w) (K).25 Spectral Power in Visible Range.2.15.1.5 35 4 45 5 55 6 65 5 8 λ (nanometers) Report Number: L1619 Page 3 of 9

Test Results: Integrating Sphere Results continued from previous page. Tabulated Spectral Power in Visible Range: λ(nm) (W/nm) λ(nm) (W/nm) λ(nm) 655 (W/nm) 35 38 385.2.2.2 515 52 525.84.96.16 66 665.45.4.35 39.3 53.113 6.31 395 4.3.4 535 54.11.121 65 68.2.24 45.5 545.123 685.21 41.8 55.124 69.18 415.14 555.125 695.16 42.25 56.126.14 425.45 565.126 5.12 43.3 5.126 1.1 435.115 55.125 15.9 44.16 58.124 2.8 445.195 585.122 25. 45.161 59.12 3.6 455.13 595.116 35.5 46.65 6.112 4.4 465.44 65.18 45.4 4.3 61.12 5.3 45.22 615.96 55.3 48.19 62.9 6.3 485.19 625.83 65.2 49.22 63.6.2 495.29 635.69 5.2 5.4 64.63 8.2 55.55 645.5 51. 65.51 Report Number: L1619 Page 4 of 9

Test Results: Goniometer Results include unit flux, distribution, efficacy, and electrical power for sample number L1619. Dialight unit model number LSC3C4MEGEX Electrical Measurements: Input Voltage: Input current: Input Power: Power Factor: 2.333 8.6.81 (VAC) (A) Photometric measurements: Absolute Luminous Flux: Luminous Efficacy: 683 95.3 (lumens) (lumens/w) Intensity Summary: ANGLE 5 15 25 35 45 55 65 5 85 95 15 115 125 135 145 155 165 15 18 ALONG 2638 263 2548 259 2913 246 131 541 34 INTENSITY (CANDLEPOWER) SUMMARY 23 45 68 2638 2638 2638 263 263 263 2548 2548 2548 259 259 259 2913 2913 2913 246 246 246 131 131 131 541 541 541 34 34 34 ACROSS 2638 263 2548 259 2913 246 131 541 34 OUTPUT LUMENS 98 55 11 163 194 1438 853 16 16 1 ZONAL LUMEN AND PERCENTAGES ZONE LUMENS % LUMINAIRE -3 2385.6 31.1% -4 424.48 55.2% -6 19.4 93.6% 6-9 45.12 9.% -9 683.4 1.% 9-18.% -18 683.4 1.% Report Number: L1619 Page 5 of 9

Test Results: Goniometer Results continued from previous page. Polar Plot: Report Number: L1619 Page 6 of 9

Test Results: Goniometer Results continued from previous page. Illuminance Plot: Illuminance-Cone of Light: Report Number: L1619 Page of 9

Test Results: In Situ Temperature Measurement Test Results include maximum LED chip temperature for sample number L1619. Dialight unit model number LSC3C4MEGEX LED identified as Cree part number XTE-AWT. LED drive current (as indicated by customer): 35 (ma) LED Specifications: LED specifications are taken from LED manufacturer datasheet: Maximum Forward Current (If): Maximum Rated Power Dissipation: Maximum Junction Temp. (Tj): Thermal Resistance (Rth): Derived Specifications: Maximum Power at Indicated Current: Maximum Source Temperature: 15 5.25 15 5 1.225 143.9 (ma) ( C/W) Test Conditions: Temperature Measurement Location: See Photographs Below Ambient Temperature: 25 ± 5 Ambient temperature at time of measurement: 23.6 Relative humidity at time of measurement: 23% Results: Measured LED source temperature: 49.5 Report Number: L1619 Page 8 of 9

Equipment Used: Equipment Name Omega TC Fluke 888A Digit Multimeter YOKOGAWA Digital Power Meter LSI High Speed Mirror Goniometer Instrument System Spectrometer Instrument System 1.5 Meter Sphere Volttech Power Analyzer Delta Elektronika DC Power Supply Elgar AC Power Supply Instek AC Power Supply Sorensen DC Power Supply Extech Hygro-Thermometer Extech Hygro-Thermometer Fluke 52II Thermometer Volttech Power Analyzer BK Precison TDK-Lambda Fluke 888A Digit Multimeter TPI Digitial Thermometer 343 TPI Digitial Thermometer 343 Step-Up Transformer Omega TC Agilent True RMS OLED Multimeter Adaptive Power Systems AC Power Supply Xitron Power Analyzer Model Number Dpi8 888A 11/26/3981 624T CAS14B-151 ISP15 PM1+ SM.3-5 CW1251P APS-951 XHR15-4/16/312 4/16/312 52II Thermometer PM1+ 115A GEN15W 888A TPI 343 TPI 343 Dpi8-C24 U123A FC-21 XT264 Additional Notes: Samples are received and tested in new and undamaged condition, unless otherwise noted. The results shown in this report are representative only of the test samples submitted. This data has been issued to the assignee for further evaluation. This report shall not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. This report shall not be reproduced, except in full, without the express written permission of. Test Report Issued By: Richard Huegi Senior Optical Engineering Technician Lighting Division Test Report Reviewed and Approved By: Vishnu Shastry Optical Engineer Approved Signatory Report Number: L1619 Page 9 of 9