Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Similar documents
Acceleration/Velocity/Displacement VIBRATION METER

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

VIBRATION METER. Instruction Manual.

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

INFRARED THERMOMETER Model : TM-959

Dual laser + type K thermometer INFRARED THERMOMETER

Mini Environmental Quality Meter

473-SHX Dew Point Mirror

473 Dew Point Hygrometer

Minimum (-31) every 10 s -35 (-31)


4 - Way Acceptance Low Maintenance Easy Installation Re - Programmable Flash ROM Auto Self -Adjusting Sensor System

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

473 Dew Point Hygrometer

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

Circular Motion and Centripetal Force

Bright Advance Corporation

O P E R A T I N G M A N U A L

InfraRed Thermometer with Laser Pointer

Microcare LCD Solar MPPT User Documentation

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

AW/AHW Professional Weighing Scale. User Manual

Magnetic Fields. Experiment 1. Magnetic Field of a Straight Current-Carrying Conductor

GW Professional Weighing Scale. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW

Dewpoint Meter Data Sheet / Instructions

Survey Meter OD-01 Address: Phone: Fax: URL:

E THERMADATA LOGGER Humidity & temperature recording meter

Data Sheet / Instructions. Dewpoint MeterO

One-hand ph/temperature measuring instrument

WEATHER STATION FOR SOLAR FARM MONITORING

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Operating Instructions for Digital Manometer. Model: MAN-SD

PG-100 HANDY MANOMETER COPAL ELECTRONICS FEATURES MODEL NUMBER DESIGNATION P G G P. marking Compatible with EMC directive

RoHS. Versatile. X g. X 2 e

DIGITAL THERMOMETER OPERATOR S MANUAL

Moisture Analyzers.

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D

Minute Impulse Clock Controller I01DN

Analog - Digital multimeters

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

Titrex ACT titrators have been designed to simply and precisely satisfy and perform the widest range of potentiometric titrations: acid-base, redox,

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

PC100 Handheld ph/cond./tds/sal. Meter. Instruction Manual

INE-PHS-3E ph Meter Operating Manual

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

MODEL: MO Digital DC Milliohm Meter OPERATING INSTRUCTION

Single cam type. Double cam type. Grip force N. Type Model/size Stroke Screw type straight style. Screw type tee style

ea980r Digital Anemometer User Manual

POINTS OF CAUTION BEFORE USE...

iweathar EDGE V Installation Guide Copyright 2012 iweathar. All rights reserved.

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

Nixie Clock Manuela Desktop. User Manual

Digital Fluxmeter CYHT700SP

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

PiCUS Calliper Version 3

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

BRIGHT-STRATO SERIES

INSTRUCTION MANUAL RS 51 & RS 52 DIGITAL THERMOMETER

A Rain Sensitive House Window Closes Automatically When Raining

Heat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

Automatic titrators, TitroMatic

HT600 Dat e Code: 2 - HT MW Purchase Date: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE. All Rights Reserved

Training Guide. Coastal Environmental Systems, Inc.

Quartz Crystal Nanobalance (QCN)

1450 First Ave. Page 1 of 10 Chippewa Falls, WI (800) or (715) Fax: (715)

X-LSM-E Series: Miniature motorized linear stages with built-in motor encoder and controllers

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

VELA. Getting started with the VELA Versatile Laboratory Aid. Paul Vernon

Operation Manual Contents subject to change without notice

Vet Photometer DP 700 Operating Manual. Version V5.9

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

Traceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away. For additional Type-K probes, see page 41.

HD32.2 WBGT Index HD 32.2 INSTRUMENT FOR THE ANALYSIS OF THE WBGT INDEX

RC Circuit (Power amplifier, Voltage Sensor)

E2T0 DVP

0501 Users Guide. Chapter I Characteristic

product manual H-3220A Benkelman Beam

Experiment P43: RC Circuit (Power Amplifier, Voltage Sensor)

User s Manual. Surface Potential Meter. Revision 1.0

WEATHER MULTI-SENSOR. Vaisala Weather Transmitter WXT510. Change the Way You Measure Weather

Evaluation copy. Ground Temperature Measurements. computer OBJECTIVES MATERIALS PRE-LAB QUESTIONS

STANDARD OPERATING PROCEDURE

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

Bante210 Benchtop ph Meter Instruction Manual

WEATHERPAK MTR Training Guide

Development of standard calibration equipment for the rain gauges

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

ph Probe ReallyEasyData com

Kestrel 4500 Pocket Weather Tracker

244241, Operation Manual Contents subject to change without notice. Version 1.0 Issue AA

Transcription:

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202 Your purchase of this VIBRATION METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and delicate instrument, its durable structure developed. Please read the following instructions carefully and always keep this manual within easy reach. OPERATION MANUAL

TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 2 3. FRONT PANEL DESCRIPTION... 4 3-1 Display... 4 3-2 BNC socket of meter...4 3-3 RS-232 output terminal...4 3-4 RMS/PEAK switch... 4 3-5 Acceleration/Velocity switch... 4 3-6 Data hold button... 4 3-7 Power button... 4 3-8 Memory RECORD button... 4 3-9 Memory RECALL button... 4 3-10 Battery compartment/cover...4 3-11 BNC plug of cable... 4 3-12 Mini plug of cable... 4 3-13 Input socket of vibration probe...4 3-14 Vibration probe...4 3-15 Sensing head...4 3-16 Magnetic base... 4 4. MEASURING PROCEDURE... 5 5. ZERO ADJUSTMENT PROCEDURE... 9 6. POWER MANAGEMENT... 10 7. RS232 PC SERIAL INTERFACE...10 8. BATTERY REPLACEMENT... 11 9. OPTIONAL ACCESSORIES... 12 10 CLASSIFICATION RANGES...12 11. SENSITIVITY RELATIVE TABLE ACCORDING ISO 2954...13

1. FEATURES * Applications for industrial vibration monitoring : All industrial machinery vibrates. The level of vibration is a useful guide to machine condition. Poor balance, misalignment & looseness of the structure will cause the vibration level increase, it is a sure sign that the maintenance is needed. * Professional vibration meter supply with vibration sensor & magnetic base, full set. * Velocity measuring range 200 mm/s. * Acceleration measuring range 200 m/s. * Frequency range 10 Hz - 1 khz, sensitivity relative meet ISO 2954. * RMS & Peak measurement. * Wide frequency range. * Data hold button to freeze the desired reading. * Memory function to record maximum and minimum reading with recall. * Separate vibration probe, easy operation * RS 232 computer interface. * Optional data acquisition software for data record & datalogger. * Super large LCD display. * Microcomputer circuit, high performance. * Auto shut off saves battery life. * Built-in low battery indicator. * Heavy duty & compact housing case. * Complete set with the hard carrying case. 1

2. SPECIFICATIONS Display Measurement 61 mm x 34 mm supper large LCD display. 15 mm ( 0.6" ) digit size. Velocity, Acceleration RMS value, Peak value, Data hold, Max. & Min. value. Range Velocity : 200 mm/s : 0.5 to 199.9 mm/s Acceleration : 200 m/s : 0.5 to 199.9 m/s 2 Frequency 10 Hz to 1 KHz range * Sensitivity relativive during the the frequency range meet ISO 2954 Refer to table 1, page 12. Accuracy ( 5 % + 2 d ) reading, 160 Hz, 80 Hz. @ 23 5 蚓 Calibration Velocity : 50 mm/s ( 160 Hz ) point Acceleration : 50 m/s 2( 160 Hz ) Circuit Exclusive microcomputer circuit. Data hold Freeze the desired reading. Peak To measure the peak value. measurement Memory Maximum & Minimum value. Power off Auto shut off, saves battery life, or manual off by push button. Sampling time Approx. 1 second. Data output RS 232 serial output, isolate. Operating 0 蚓 to 50 蚓 ( 32 蚌 to 122 蚌 ). temperature Operating Less than 80% RH. humidity 2

Power supply Alkaline or heavy duty type, DC 9V battery, 006P, MN1604 (PP3) or equivalent. Power Approx. DC 6 ma. consumption Weight Meter 230 g/0.50 LB Probe with 165 g/0.36 LB sensing head Dimension Meter : 180 x 72 x 32 mm ( 7.1 x 2.8 x1.3 inch ). Vibration probe : Round 36 mm Dia. x 71 mm. Sensing head : 8.9 mm Dia x 42 mm length Cable length : 1.2 meter. Accessories Instruction manual... 1 PC. included Cable with plugs... 1 PC. Vibration probe... 1 PC. Sensing head... 1 PC. Magnetic base... 1 PC. Carrying Case... 1 PC. Optional * Software ( Windows version, data accessories record & data acquisition )...SW-U801-WIN * RS232 cable...upcb-01 3

3. FRONT PANEL DESCRIPTION Fig. 1 3-1 Display 3-9 RECALL button 3-2 BNC socket of meter 3-10 Battery compartment 3-3 RS-232 output /cover terminal 3-11 BNC plug of cable 3-4 RMS/PEAK switch 3-12 Mini plug of cable 3-5 Acceleration/Velocity 3-13 Input socket of switch vibration probe 3-6 Data hold button 3-14 Vibration probe 3-7 Power button 3-15 Sensing head 3-8 RECORD button 3-16 Magnetic base 4

4. MEASURING PROCEDURE 1) Plug in the " BNC plug of cable " ( 3-11, Fig. 1 ) to the " BNC socket of meter " ( 3-2, Fig. 1 ). 2) Plug in the " Mini plug of cable " ( 3-12, Fig. 1 ) to the " Input socket of vibration probe " ( 3-13, Fig. 1 ). 3) For the acceleration measurement, select the " Acceleration/Velocity switch " ( 3-5, Fig. 1 ) to the " ACC. " position. For the velocity measurement, select the " Acceleration/Velocity switch " ( 3-5, Fig. 1 ) to the " VEL. " position. For general applications of industrial vibration monitoring, select " Velocity measurement " typically. 4) Select the " RMS/PEAK switch " ( 3-4, Fig. 1 ) to the " RMS " position. 5) Power on the meter by pushing the " Power button " ( 3-7, Fig. 1 ) once. 6) For the general application, connect the " Sensing head " ( 3-15, Fig. 1 ) to the " Vibration probe " ( 3-14, Fig. 1 ), refer Fig. 2. Hold the vibration probe by hand & touch the sensing head to the surface of the measuring article vertically, refer the Fig. 3. 5

Fig. 2 Fig. 3 7) If the surface material of measuring article is the ferrous material, connecting the " Vibration probe " ( 3-14, Fig. 1 ) with the " Magnetic base " ( 3-16, Fig. 1 ), refer Fig. 4. Put the whole unit ( Vibration probe & Magnetic base ) to the surface of measuring article, refer Fig. 5. 6

Fig. 4 Fig. 5 7

8) PEAK value measurement Before the measurement if select the " RMS/PEAK switch " ( 3-4, Fig. 1 ) to the " PEAK " position. Then during the measurement, the display will display the peak value. 9) Data Hold During the measurement, push the " Data Hold button " ( 3-6, Fig. 1 ) will hold the measured value & the LCD will indicate " D.H." symbol. Push the " Data hold button " again to release the data hold function. 10) Data Record ( Max., Min. reading ) * The DATA RECORD function displays the maximum & minimum readings. To start the DATA RECORD function, press the " RECORD Button " ( 3-8, Fig. 1 ) once. " REC " symbol will appear on the LCD display. * With the " REC " symbol on the display : (a) Push the " RECALL button " ( 3-9, Fig. 1 ) once, the " Max " symbol along with the maximum value will appear on the display. (b) Push the " RECALL Button" again, the " Min " symbol along with the minimum value will appear on the display. (c) To exit the memory record function, push the " RECORD " button once again. The display will revert back to the current reading. 8

5. ZERO ADJUSTMENT PROCEDURE Due to drift of environment temperature value, battery power change or, meter used for a long time or other reasons. The display value may exist not zero value ( few digits ) in case of no signal into the " Vibration Sensor ". General speaking those not zero value will not effect the measurement typically. However if intend to make the precision measurement, the following zero adjustment procedures should be executed as : 1)Select the " Acceleration/Velocity Switch " to the " Acceleration " position. 2)No signal into the vibration sensor. 3)Open the battery cover. 4)Use a convenient screw driver to adjust " Zero adjust VR " until the display reach the zero value. 9

6. POWER MANAGEMENT The meter is built the " Auto power shut off " to saves battery life. If not any function button be pushed within approx. 10 minutes, the power will be off automatically. If the user intend to disable the " Auto Power off " function, it should take the following procedures : During the measurement, push the " Record Button " ( 3-8, Fig. 1 ) to execute the memory record function. 7. RS232 PC SERIAL INTERFACE The instrument features an RS232 output via 3.5 mm Terminal ( 3-3, Fig. 1 ). The connector output is a 16 digit data stream which can be utilized to the user's specific application. An RS232 lead with the following connection will be required to link the instrument with the PC serial input. Meter PC (3.5 mm jack plug) (9W 'D" Connector) Center Pin... Pin 2 Ground/shield...Pin 5 10

The 16 digit data stream will be displayed in the following format : D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Each digit indicate the following status : D0 End Word D1 to D4 Upper Display reading, D1=LSD, D4=MSD D5 to D8 D5 =? D6 =? D7 =? D8 =? D9 Decimal Point ( DP) for display. 0 = No DP, 1= 1 DP, 2 = 2 DP, 3 = 3 DP D10 D10 = 0 D11 D11 = 0 D12 D12 = 0 D13 D13 = 0 D14 D14 = 0 D15 Start Word RS232 FORMAT : 9600, N, 8, 1 8. BATTERY REPLACEMENT 1) When the left corner of LCD display show " LBT ", it is necessary to replace the battery. However, in-spec measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate. 2) Use the coining or " - " screw driver to open the " Battery Cover " ( 3-10, Fig. 1 ) away from the instrument and remove the battery. 3) Install a 9 V battery ( Akaline or heavy duty ) and replace the cover. 11

9. OPERATIONAL ACCESSORIES RS-232 cable, Model : UPCB-01 RS-232 cable, used for connecting the vibration meter & the computer. Application After setup whole hardware Software ( Window version ) Vibration meter + RS-232 cable + Computer + software ( SW-U801-WIN SW-U801-WIN ) whole system can execute as a data logger, data recorder... record data can be retrieved for EXCELL, LOTUS-123... 10. CLASSIFICATION RANGES For the valuation of machines and equipment in the ISO 2372 and VDI 2056, four different kinds of machine groups with four classification ranges and their limits for vibration severity ( mm/s ) are determined. The classifications for each machine group are specified as follows : Small machines, especially production electrical motors of up to 15 KW ( Group K ) Good Acceptable Still permissible Dangerous 0 to 0.71 mm/s 0.72 to 1.80 mm/s 1.81 to 4.5 mm/s > 4.5 mm/s 12

Medium sized machines, especially electrical motors with 15 up to 75 KW output, without special foundations ( Group M ) Good Acceptable Still permissible Dangerous 0 to 1.12 mm/s 1.13 to 2.80 mm/s 2.81 to 7.1 mm/s > 7.1 mm/s Large machines on heavy foundations ( Group G ) Good Acceptable Still permissible Dangerous 0 to 1.80 mm/s 1.81 to 4.50 mm/s 4.51 to 11.2 mm/s > 11.2 mm/s Largest machines and turbo machines with a special foundations ( Group T ). Good Acceptable Still permissible Dangerous 0 to 2.80 mm/s 2.81 to 7.10 mm/s 7.11 to 18.0 mm/s > 18 mm/s 11. SENSITIVITY RELATIVE to the reference sensivity at 80 Hz, according ISO 2954 Frequency Relative snesivity Hz Normal Minimum Maximum value value value 10 Hz 1.0 0.8 1.1 20 Hz 1.0 0.9 1.1 40 Hz 1.0 0.9 1.1 80 Hz 1.0 1.0 1.0 160 Hz 1.0 0.9 1.1 500 Hz 1.0 0.9 1.1 1000 Hz 1.0 0.8 1.1 Table 1 13 0305-VB-8202