Property of Monitronics Inc

Similar documents
NOTE: Opening and Closing Reports must be enabled. See CL 2C Digit Positions 1 and 3 for additional information.

GW Professional Weighing Scale. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW

AW/AHW Professional Weighing Scale. User Manual

Bright Advance Corporation

MODBUS Protocol for CS141 network card families

VELA. Getting started with the VELA Versatile Laboratory Aid. Paul Vernon

Minute Impulse Clock Controller I01DN

zulu - inca - kundalini - cozmo Welcome to the Ownership of a YES Watch.

Measure - Conductivity STANDARD Last std: Sep 10:17 am. Touch meas to measure sample. Touch std to access standardize mode ATC. 25.

This page intentionally left blank.

Lightcloud Application

RC Circuits. 1. Designing a time delay circuit. Introduction. In this lab you will explore RC circuits. Introduction

RADIATION-METER TM-91/TM-92

WeatherHub2 Quick Start Guide

Motors Automation Energy Transmission & Distribution Coatings. Servo Drive SCA06 V1.5X. Addendum to the Programming Manual SCA06 V1.

SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide

Operation Manual Contents subject to change without notice

Operating instructions for electronics

IO-Link Data Reference Guide: K50 Pro Touch Button with IO-Link

MP3 Digital Voice Module Model No.: VCM-SD Rev.A3. Content

TECDIS and TELchart ECS Weather Overlay Guide

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

WLDS-20 Mk2 MAJOR WATER LEAK DETECTION SYSTEM INSTALLATION & COMMISSIONING

Object Modeling Approach! Object Modeling Approach!

ECE Homework Set 2

T1 and E1 Feature Cards

T4 TIMER - PROJECT DESCRIPTION - rev. 5.10

INFRARED THERMOMETER TM0819

AlphaLab Gaussmeter Model VGM -- Instructions

Minimum (-31) every 10 s -35 (-31)

Dual laser + type K thermometer INFRARED THERMOMETER

ISSP User Guide CY3207ISSP. Revision C

MODELS Number WW4.x For Europe & Others V 50HZ

PC Control / Touch Control

PAA-ANALYZERS PRINCIPLE OF OPERATION

Professional Wind Station

U.S. Atomic Clock & Weather Station. Instruction Manual

Speedtech Deerhunter s EDGE TM Model HE-1. Speedtech ECO EDGE TM Model EE-1. User s Manual

O P E R A T I N G M A N U A L

State modeling. Marlon Dumas. Institute of Computer Science

ea980r Digital Anemometer User Manual

CiA Draft Standard Proposal CANopen. Application Profile for Lift Control Systems. Part 2: Virtual device definitions

T R A I N I N G M A N U A L 1. 9 G H Z C D M A P C S 80 0 M H Z C D M A /A M P S ( T R I - M O D E ) PM325


Module 7. Software Engineering Issues. Version 2 EE IIT, Kharagpur 1

Digital Controller Operation

X-RAY SCATTERING AND MOSELEY S LAW. OBJECTIVE: To investigate Moseley s law using X-ray absorption and to observe X- ray scattering.

Cosmic Ray Detector Software

SUBJECT TO CHANGE WITHOUT NOTICE

Instruction Manual HI Refractometer for Invert Sugar Measurements

WS-9018U Wireless Weather Station. Instruction Manual

Account Setup. STEP 1: Create Enhanced View Account

OPERATING INSTRUCTIONS

WHO TO CALL. NON-EMERGENCY NUMBERS Campus Public Safety 5555 Off-Campus & Cell Phones Environmental Health & Safety

Search for the Gulf of Carpentaria in the remap search bar:

Tippecanoe County ARES Net Formats NET 1-4. Net Formats

GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL

2 ACCESSING VARIOUS MODES

Instructor s Advance Preparation

MAGPOWR TENSION CONTROL DLCA NET-SLIM. User Manual. Digital Load Cell Amplifier MI 850A358 1 A

Hadrons Desktop U.S. Atomic Clock & Weather Station

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

BMPC. Technical Manual BRUKER. Version. J:\Nil\BMPC Manual\BMPC_FM7\BMPC.COV März 18, :53 am

XR Analog Clock - Manual Setting Model Troubleshooting Guide

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

PHYSICS 122 Lab EXPERIMENT NO. 6 AC CIRCUITS

Wireless Weather Station Instruction Manual

Display counter electromechanical

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

FlexSQUARE Square shaped beacons

Operating Instructions for Digital Manometer. Model: MAN-SD

SkyScan EWS-PRO - Manual -

Installation and Operation Manual. AllSync Plus Wired Clocks

CLOCKS MARATHON WATCH COMPANY LTD.

QNET Experiment #05: HVAC System Identification. Heating, Ventilation, and Air Conditioning Trainer (HVACT) Student Manual

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

iweathar EDGE V Installation Guide Copyright 2012 iweathar. All rights reserved.

Overlay Transport Virtualization (OTV) Unicast-Mode Transport Infrastructure Deployment

HURRICANE PREPAREDNESS GUIDE

Chapter 10 Verification and Validation of Simulation Models. Banks, Carson, Nelson & Nicol Discrete-Event System Simulation

RHS 980C OPERATION MANUAL

Rain Watch TM Set up Manual. IC System with Rain Bird IC CONNECT

TSC JR 2 Manual SERIES 4B, 5B & 6B

Set up and Operation Manual

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

Monitoring Radar Mechanical Drive Systems FAA's choice of monitoring solutions

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

PAX2S Modbus Register Table REVISED 2/20/12 LP0894A

MAN-SGY-012-V11 EC 5195 Fairford Electronics Ltd - Synergy Modbus RTU Programming Manual - 22nd February 2016 Page 1 of 59.

Circuit Analysis and Ohm s Law

RHS 980C. Operation Manual

IS YOUR BUSINESS PREPARED FOR A POWER OUTAGE?

Using a Microcontroller to Study the Time Distribution of Counts From a Radioactive Source

CA84688 FAQS TABLE OF CONTENTS

VISY-Quick Communication Protocol

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

Ben Hogben. RRLC October 12, 2016

Precision Circuits Inc

C85485 FAQS CONTENTS. Temperature Alerts... 7 Set Alerts:... 8

Release notes for measuring cycles, software version

Transcription:

Enter Program 4140 + 8 + 0 + 0 (Display should show 00, also try 4130 and 5130) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by pressing * and #) Move to Location View Location * + Location # + Location (Display will read off one digit at a time) Exit Program *98 OR *99 if needing to re-enter programming later by Code + 8 + 00 Report Codes Zones 1 to 8 alarms send 31 to 38, troubles (optional) send 51 to 58 Zones 9 to 17 alarms send 41 to 49, troubles (optional) send 61 to 69 Duress = 26, Police Panic = 29, Medical Panic = 27, Fire Panic = 28 AC Failure = 79, Low Battery = 78, Cancel = D1 Hex Program Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15 Alpha Keypads can only be 5330 or 5337, cannot use 6139 (NOT required for programming) *00 Installer Code l 4 l 1 l 4 l 0 l (also try 4130 and 5130) *01 Master Code l 1 l 2 l 3 l 4 l *02 Zone Types for Zones 1 to 8 *03 Zone Types for Zones 9 to 16 l? l? l Zone 1 l? l? l Zone 9 00 = Disabled l? l? l Zone 2 l? l? l Zone 10 01 = Entry/Exit 1 l? l? l Zone 3 l? l? l Zone 11 02 = Entry/Exit 2 l? l? l Zone 4 l? l? l Zone 12 03 = Instant l? l? l Zone 5 l? l? l Zone 13 04 = Interior l? l? l Zone 6 l? l? l Zone 14 05 = Day Zone l? l? l Zone 7 l? l? l Zone 15 06 = Silent Holdup l? l? l Zone 8 l? l? l Zone 16 07 = Audible Police 08 = 24 Hour Auxiliary *04 Zone Type for Zone 17 to 24 *05 Zone Types for 25 to 09 = Fire w/o Verification l? l? l Zone 17 10 = Interior Delay l 0 l 0 l Not Used l 0 l 0 l Zone 97 Polling LP l 0 l 9 l Zone 95 1 & * l 0 l 8 l Zone 96 3 & # l 0 l 7 l Zone 99 * & # *06 Designate Right Loop Zns 10 to 16 l 1 l 1 l 1 l 1 l 1 l 1 l 0 = 4208/4192/4275 Expander (Hardwire Zone Expander) 1 = 4190WH or 4196 Expander *07 Designate Right Loop Zone 17 l 1 l 0 = 4208/4192/4275 Expander (Zone Expander) 1 = 4190WH or 4196 Expander *08 Not Used *09 Entry Delay l 0 l 2 l 00 to 15 x15 seconds *10 Exit Delay 1 l 0 l 4 l 00 to 15 x15 seconds *11 Entry Delay 2 l 0 l 3 l 00 to 15 x15 seconds *12 Exit Delay 2 l 0 l 4 l 00 to 15 x15 seconds *13 Alarm Sounder Duration l 0 l 4 l (0 to 15 x2 minutes) *14 Alarm Sounder Type l 0 l (Must be 0) *15 Keyswitch Enable l 0 l 0 = No *16 Confirmation of Arming Ding l 0 l 0 = Disable 1 = Enable *17 AC Loss Keypad Sounding l 1 l 0 = No *18 Not Used *19 Control Alarm Sound Disable l 0 l 0 = No *20 Not Used

*21 No Fire Timeout l 1 l 0 = No *22 Fire Display l 1 l 0 = No *23 Multiple Alarms l 1 l 0 = No *24 Disable Tamper Zone 10-17 l 0 l 0 = No *25 Disable Duress in In Hi Speed Frmt l 0 l 0 = No *26 Internal Alarm Sound l 0 l 0 = Steady Siren 1 = Sweeping Siren *27 Test Report Interval l 0 l 0 = No Report 1 = 12, 2 = 24, 3 = 168 Hrs) *28 Power up in Prev State l 0 0 = No *29 Quick Arm l 1 l 0 = No *30 Touch Tone Dialing l 1 l 0 = No *31 PABX Access Code l _l _l _l _l (To dial 9 add here) *32 Primary Account Number l 0 l? l 0 l? l 0 l? l (2 digit entries) Hex B = 11, C = 12, D = 13, E = 14, F = 15 *33 Primary Phone Number (12 digits) l _l _l _l _l _l _l _l _l _l _l _l _l End Phone with * # + 11 = *, # + 12 = #, # + 13 = 2.5 second pause *34 Secondary Phone Number l _l _l _l _l _l _l _l _l _l _l _l _l *35 Download Phone Number l 1 l 8 l 0 l 0 l 6 l 8 l 2 l 1 l 6 l 9 l 0 l *36 CSID Number l 1_ l 5 _l 1_ l 5 _l 1_ l 5 _l 1_ l 5 _l 1_ l 5 _l 1_ l 5 _l 1_ l 5 _l 1_ l 5 _l (15's Default CSID to Factory) *37 Download Commands Enable l 1_ l Dialer Shutdown 0 = No l 1_ l System Shutdown l 0 _l Not Used l 1_ l Remote Bypass l 1_ l Remote Disarm l 1_ l Remote Arm l 1_ l Upload Programming l 1_ l Download Programming *38 Priority Zone l 0 l 0 l (All zones bypassable) *39 Open/Close Report Users 9 to 15 l 0 l 0 l 0 l 0 l 0 l 0 l 0 l 0 l 0 = No *40 Program Tamper Report l 0 l 0 l Disabled *41 Normally Closed Zones 2-8 l 0 l 0 = EOL Resistors 1 = Normally Closed Loops *42 Dial Tone Pause l 0 l 0 = 5 seconds 1 = 11 seconds 2 = 30 seconds *43 Dial Tone Detection l 0 l 0 = Disable 1 = Enable *44 Ring Detection Count l 1 l 5 l 15 = Answering Machine Bypass *45 Primary Ack Wait l 0 l 0 = 30 seconds 1 = 60 seconds

*46 Primary Format l 0 l 0 = Ademco Lo (This system cannot send Contact ID) 1 = Sescoa/Radionics 2 = Ademco High Speed *47 Secondary Ack Wait l 0 l 0 = 30 seconds 1 = 60 seconds *48 Secondary Format l 1 l 0 = Ademco Lo 1 = Sescoa/Radionics 2 = Ademco High Speed *49 Checksum Verify l 0 l 0 = No *50 Sescoa Radionics Select l 0 l 0 = Radionics 1 = Sescoa *51 Dual Reporting l 0 l 0 = No *52 Open/Close Rep Enable User 1 to 8 l 1 l 0 l 0 l 0 l 0 l 0 l 0 = No (User 1 must be enabled to allow Installer Code entry into programming) *53 4/2 Zone Format 17 Zone Selection l 1 l 0 = Non Reported Zone 1 = 4/2 Reporting *54 4/2 Zone Format 9 Zone Selection l 1 l 0 = 3/1 Ademco Hi Speed 1 = 4/2 Reporting *55 Alarm Report l 0 l 0 = Standard *56 Restore Report l 0 l 0 = Standard *57 Bypass Report l 0 l 0 = Standard *58 Trouble Report l 0 l 0 = Standard *59 Open/Close Report l 0 l 0 = Standard ) *60 Low Bat, AC Loss Report l 0 l 0 = Standard ****IMPORTANT for the below reporting to send correctly *46 must be 0 and *53 must be 1**** *76 Channel Assigned to Zones 1 to 8 *72 4/2 Expanded Format Zones 1 o 8 l 0 l 1 l Zone 1 l 0 l 3 l Alarm l 0 l 2 l Zone 2 l 0 l 5 l Trouble (Optional) l 0 l 3 l Zone 3 l 0 l 4 l Zone 4 l 0 l 5 l Zone 5 l 0 l 6 l Zone 6 l 0 l 7 l Zone 7 l 0 l 8 l Zone 8 *72 is 1st digit of Report code, *76 is 2nd digit, Zones 1 to 8 send Alarm 31 to 38, Trouble sends 51 to 58 *77 Channel Assigned to Zones 9 to 16 *73 4/2 Expanded Format Zones 9 to 16 l 0 l 1 l Zone 9 l 0 l 4 l Alarm l 0 l 2 l Zone 10 l 0 l 6 l Trouble (Optional) l 0 l 3 l Zone 11 l 0 l 4 l Zone 12 l 0 l 5 l Zone 13 l 0 l 6 l Zone 14 l 0 l 7 l Zone 15 l 0 l 8 l Zone 16 *73 is 1st digit of Report code, *77 is 2nd digit, Zones 9 to 16 send Alarm 41 to 48, Trouble sends 61 to 68

*78 Channel Assigned to Zone 17 *74 4/2 Expanded Format Zone 17 l 0 l 9 l Zone 17 l 0 l 4 l Alarm l 0 l 6 l Trouble (Optional) *74 is 1st digit of Report code, *78 is 2nd digit, Zone 17 sends Alarm 49, Trouble sends 69 *79 Channel Assigned to Panics *75 4/2 Expanded Format Panics l 0 l 2 l Alarm l 0 l 0 l Trouble l 0 l 6 l Duress l 0 l 0 l Polling Loop Short l 0 l 8 l 1 & * (Fire Panic) l 0 l 7 l 3 & # (Medical Panic) l 0 l 9 l * & # (Police Panic) *75 is 1st digit of Report code, *79 is 2nd digit Duress sends 26, Medical sends 27, Fire sends 28, Police sends 29 *80 4 + 2 Expanded Format Non-Alarm Codes *81 4 + 2 Expanded Format Non-Alarm Codes 1st Digit 2nd Digit 1st Digit 2nd Digit l 0 l 0 l l 0 l 0 l Close Report l 0 l 0 l l 0 l 0 l Power-Up l 0 l 0 l l 0 l 0 l Open Report l 0 l 7 l l 0 l 9 l AC Loss (79) l 0 l 7 l l 0 l 8 l Low Battery Report (78) l 0 l 0 l l 0 l 0 l AC Restore l 0 l 0 l l 0 l 0 l Low Battery Restore Report l 0 l 0 l l 0 l 0 l l 0 l 0 l Test Report l 1 l 3 l l 0 l 1 l Cancel (D1) *82 Swinger Shutdown l 0 l 3 l 00 to 15 Alarms *83 Test Report Start l 0 l 0 l 00 = Instant 01-31 hours *84 Kissoff Wait l 0 l 0 = No Watts Line 1 = Watts Line *85 DO NOT PROGRAM *86 Zone Expander Type l 0 l (1=No 4206, 0=Other RPM's) *87 Entry Warning l 0 l (1=Continous, 0=No Delay) *88 Burg Alarm Comm Delay l 0 l 0 = No Delay, 1 = 16 second Delay *89 Alarm Voltage Out Triggers l 0 l 0 = No Alarm Trigger, Zone Expander 1 = Alarm Trigger, No Zone Expander *93 5137 LCD Keypad Programming *97 Default Panel (No Value needed, keypad will beep and default panel)

Monitronics Monitoring and Service: 1-800-447-9239 Ademco Vista-XT Quick Reference Guide Arm Away User Code + AWAY (2) Note: If system shows NOT READY press to view open zones Arming Stay User Code + STAY (3), System will bypass all interior Zones Instant Doors Disarming / Silencing Alarms Zone Bypassing Additional Codes User Code + INSTANT (7) All Entry/Exit doors will arm with no entry delay and all motion or interior zones will be bypassed User code + OFF (1) If turning off an alarm enter User Code + OFF key (1) again to clear display User code + BYPASS (6) + Zone (01 to 15) Note: Fire/Smoke Detector Zones cannot be bypassed Enter Master Code + CODE (8) + User (03 to 22) + New User Code (System will beep when completed) To delete a code: Enter Master Code + CODE (8) + User to delete (03 to 22) + Master Code again Note: The Master Code can only be changed by a Service Technician or by Downloading Door Chimes Master Code + CHIME (9) Trouble Display Panic Buttons NO AC = Loss of AC power to the system LOW BAT = Main panel has a low battery, if LOW BAT appears with a zone number that zone has low battery CHECK = There is a problem with a zone (system will show zone number on display) Press and # at same time for Police Panic Press 1 and at the same time for Fire Panic Press 3 and # at the same time for Medical Panic Note: The Fire and Medical Panics may be reversed or disabled on some systems Do not pause more than 2 seconds between each keypress or system will ignore above commands