The Dayton Power and Light Company Load Profiling Methodology Revised 7/1/2017

Similar documents
LOADS, CUSTOMERS AND REVENUE

Multivariate Regression Model Results

PREPARED DIRECT TESTIMONY OF GREGORY TEPLOW SOUTHERN CALIFORNIA GAS COMPANY AND SAN DIEGO GAS & ELECTRIC COMPANY

RD1 - Page 469 of 578

Demand Forecasting Models

2018 Annual Review of Availability Assessment Hours

Defining Normal Weather for Energy and Peak Normalization

REVISED UPDATED PREPARED DIRECT SAFETY ENHANCEMENT COST ALLOCATION TESTIMONY OF GARY LENART SAN DIEGO GAS & ELECTRIC COMPANY AND

Determine the trend for time series data

peak half-hourly Tasmania

Advance signals that can be used to foresee demand response days PJM SODRTF - March 9, 2018

EVALUATION OF ALGORITHM PERFORMANCE 2012/13 GAS YEAR SCALING FACTOR AND WEATHER CORRECTION FACTOR

3. If a forecast is too high when compared to an actual outcome, will that forecast error be positive or negative?

Chapter 3. Regression-Based Models for Developing Commercial Demand Characteristics Investigation

SAN DIEGO GAS AND ELECTRIC COMPANY SOUTHERN CALIFORNIA GAS COMPANY 2013 TRIENNIAL COST ALLOCATION PROCEEDING (A ) (DATA REQUEST DRA-MPS-2)

2014 FORECASTING BENCHMARK AND OUTLOOK SURVEY. Mark Quan and Stuart McMenamin September 16, 2014 Forecasting Brown Bag Seminar

Summary of Seasonal Normal Review Investigations. DESC 31 st March 2009

2013 WEATHER NORMALIZATION SURVEY. Industry Practices

2018 FORECAST ACCURACY BENCHMARKING SURVEY AND ENERGY TRENDS. Mark Quan

From Sales to Peak, Getting It Right Long-Term Demand Forecasting

NSP Electric - Minnesota Annual Report Peak Demand and Annual Electric Consumption Forecast

peak half-hourly New South Wales

Into Avista s Electricity Forecasts. Presented by Randy Barcus Avista Chief Economist Itron s Energy Forecaster s Group Meeting

As included in Load Forecast Review Report (Page 1):

Nicor Gas Rider 6 History Gas Supply Cost Factors (Cents Per Therm) MONTH GCR (R/) UFR (S/) GCNR (T/) UFNR (U/) GC CGC DGC NCGC TSA CSBC SSCR BSA

Ameren Missouri Peak Load Forecast Energy Forecasting Meeting, Las Vegas. April 17-18, 2013

SHORT TERM LOAD FORECASTING

Variables For Each Time Horizon

A summary of the weather year based on data from the Zumwalt weather station

Monthly Sales Weather Normalization and Estimating Unbilled Sales. Al Bass Kansas City Power & Light EFG Meeting Las Vegas, NV April 2-3, 2014

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF COLORADO * * * * *

2013 FORECAST ACCURACY BENCHMARKING SURVEY AND ENERGY

BEFORE THE PUBLIC UTILITY COMMISSION OF THE STATE OF OREGON UE 294. Load Forecast PORTLAND GENERAL ELECTRIC COMPANY. Direct Testimony and Exhibits of

Normalization of Peak Demand for an Electric Utility using PROC MODEL

November 2018 Weather Summary West Central Research and Outreach Center Morris, MN

2013 Weather Normalization Survey. Itron, Inc El Camino Real San Diego, CA

WEATHER NORMALIZATION METHODS AND ISSUES. Stuart McMenamin Mark Quan David Simons

Product and Inventory Management (35E00300) Forecasting Models Trend analysis

DAILY QUESTIONS 28 TH JUNE 18 REASONING - CALENDAR

Seasonal Hazard Outlook

Development of Short-term Demand Forecasting Model And its Application in Analysis of Resource Adequacy. For discussion purposes only Draft

URD Cable Fault Prediction Model

Integrated Electricity Demand and Price Forecasting

Report on System-Level Estimation of Demand Response Program Impact

Copyright 2010 Pearson Education, Inc. Publishing as Prentice Hall.

MINNESOTA DEPARTMENT OF TRANSPORTATION Engineering Services Division Technical Memorandum No MAT-02 October 7, 2014

SMART GRID FORECASTING

DEMAND FORECASTING PROTOCOL

Colorado State University, Fort Collins, CO Weather Station Monthly Summary Report

Wind power and management of the electric system. EWEA Wind Power Forecasting 2015 Leuven, BELGIUM - 02/10/2015

REPORT. Non-Controls Lighting Evaluation for the Massachusetts Small Business Direct Install Program: Multi-Season Study.

Forecast Postalised Tariff 2015/ /20. Utility Regulator Explanatory Note. August Introduction

WRF Webcast. Improving the Accuracy of Short-Term Water Demand Forecasts

Resource Adequacy Load Forecast A Report to the Resource Adequacy Advisory Committee

LOAD POCKET MODELING. KEY WORDS Load Pocket Modeling, Load Forecasting

SUPPLEMENTAL PREPARED DIRECT TESTIMONY OF CHRISTOPHER SWARTZ ON BEHALF OF SAN DIEGO GAS & ELECTRIC COMPANY IN SUPPORT OF SECOND AMENDED APPLICATION

2006 IRP Technical Workshop Load Forecasting Tuesday, January 24, :00 am 3:30 pm (Pacific) Meeting Summary

Fleming County Schools Long Range Plan Teacher(s):

Statement of indicative wholesale water charges and charges scheme

Short-Term Load Forecasting Using ARIMA Model For Karnataka State Electrical Load

Total Market Demand Wed Jan 02 Thu Jan 03 Fri Jan 04 Sat Jan 05 Sun Jan 06 Mon Jan 07 Tue Jan 08

2019 Settlement Calendar for ASX Cash Market Products. ASX Settlement

Chapter 1 0+7= 1+6= 2+5= 3+4= 4+3= 5+2= 6+1= 7+0= How would you write five plus two equals seven?

My Calendar Notebook

Ontario Demand Forecast

September 2018 Weather Summary West Central Research and Outreach Center Morris, MN

Peak Shifting Discussion and Forecast Sensitivities

UNBILLED ESTIMATION. UNBILLED REVENUE is revenue which had been recognized but which has not been billed to the purchaser.

not for commercial-scale installations. Thus, there is a need to study the effects of snow on

The North American Electric Reliability Corporation hereby submits Informational Filing of the North American Electric Reliability Corporation.

Short-Term Electrical Load Forecasting for Iraqi Power System based on Multiple Linear Regression Method

Operations Report. Tag B. Short, Director South Region Operations. Entergy Regional State Committee (ERSC) February 14, 2018

Page No. (and line no. if applicable):

Gorge Area Demand Forecast. Prepared for: Green Mountain Power Corporation 163 Acorn Lane Colchester, Vermont Prepared by:

Capacity Market Load Forecast

Developing an Hourly Profile for a Monthly Forecast

STATISTICAL LOAD MODELING

Abram Gross Yafeng Peng Jedidiah Shirey

Design of a Weather- Normalization Forecasting Model. Final Report

Wind Rules and Forecasting Project Update Market Issues Working Group 12/14/2007

FORECAST ACCURACY REPORT 2017 FOR THE 2016 NATIONAL ELECTRICITY FORECASTING REPORT

UNITED KINGDOM FOREIGN AND COMMONWEALTH OFFICE, DRAGON CAPITAL GROUP

peak half-hourly South Australia

The Use of EDD for Weather Normalisation

What Patterns Can Be Observed in a Year?

Lightcloud Application

QUANTIFICATION OF THE NATURAL VARIATION IN TRAFFIC FLOW ON SELECTED NATIONAL ROADS IN SOUTH AFRICA

A Re-examination of the Lost Lake Effect in Buffalo, New York

Fire Weather Drivers, Seasonal Outlook and Climate Change. Steven McGibbony, Severe Weather Manager Victoria Region Friday 9 October 2015

5, 0. Math 112 Fall 2017 Midterm 1 Review Problems Page Which one of the following points lies on the graph of the function f ( x) (A) (C) (B)

Short Term Load Forecasting Based Artificial Neural Network

Fundamentals of Transmission Operations

Colorado State University, Fort Collins, CO Weather Station Monthly Summary Report

Calendarization & Normalization. Steve Heinz, PE, CEM, CMVP Founder & CEO EnergyCAP, Inc.

Battery Energy Storage

Agricultural Science Climatology Semester 2, Anne Green / Richard Thompson

Design of a Weather- Normalization Forecasting Model

Design of a Weather-Normalization Forecasting Model

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF COLORADO * * * *

A Fuzzy Logic Based Short Term Load Forecast for the Holidays

Transcription:

The Dayton Power and Light Company Load Profiling Methodology Revised 7/1/2017 Overview of Methodology Dayton Power and Light (DP&L) load profiles will be used to estimate hourly loads for customers without interval metering for use in retail energy imbalance calculations. In addition, these same load profiles will be made available to Alternate Generation Suppliers in order to assist in scheduling hourly loads for retail load aggregations of customers they may serve within the DP&L distribution service territory. In developing load profiles for various customer classes, DP&L has utilized a dynamic modeling methodology based on Company load research data. Each of DP&L s retail electric distribution customers without interval metering has been assigned to one of seventeen load profile categories developed by the Company. Load profile categories were developed in order to group customers with homogeneous load patterns and usage characteristics. Rate class and voltage level load research data was examined to determine the appropriate profile segments based on rate classification, usage and demand level characteristics. Each of the DP&L profile segments was used to develop a dynamic profile model that will be used to produce daily profiles based on day of the week, season and actual weather conditions where applicable. The dynamic modeling approach entails developing hourly class load models that relate hourly demand with day of the week, season, and weather conditions. Dynamic modeling is one method of reflecting a weather response mechanism in a mathematically modeled form. This method builds on DP&L s available load research data and incorporates calendar and weather information that will be secured from external sources. Each day, DP&L will post the following load profile information to its supplier web site (http://cres.dpandl.com): 1) Up to 17 load profiles for the previous day, based on day of week and actual weather (when applicable). This daily load profile information will be used to inform suppliers of the profiles that will be used in developing hourly load allocations for retail energy imbalance settlements, and to assist suppliers in developing their own retail load forecasts and energy schedules. Definition Load profiling is an estimation and allocation process. Customers with hourly interval metering will have their actual demands used to determine their load responsibility on the system. For customers without interval demand meters, load research data is used to build profiles that

provide a mechanism to convert their daily or monthly energy use into an hourly load responsibility. Load profiling is defined as: 1) the application of generic industry load shapes as a proxy for local customer usage patterns; or 2) the use of a load shape generated from load research samples to be used as a proxy for customer usage patterns. The use of generic industry load shapes is the least complex approach to gathering load research data, but it includes error due to both sampling and the differences between generic and utility specific customer usage patterns. DP&L has utilized load research samples to develop its load profiles. DP&L Load Profile Classes DP&L has developed seventeen (17) load profile classifications for its non-interval metered retail electric distribution customers. Customers are classified according to rate classification, usage and demand level characteristics. Customers will be reassigned to profile classes based on these characteristics on an annual basis, during the month of October. The residential electric heat rate class represents its own profile class (1 profile). The residential non-electric heat rate class customers are grouped into two strata based on annual usage levels. The load research samples demonstrated that customers within this rate class have different load patterns depending on whether they are high or low usage customers. A class average default profile will be assigned to any customers within this rate class with insufficient usage data for profile classification, i.e. new service points (3 profiles). The commercial and industrial profiled tariffs employ a more defined segmentation where the segments are based on a combination of rate class, usage, kw demand and load factor. Secondary rate class customers are grouped by usage level. A class average default profile will be assigned to any customers within this rate class with insufficient usage data for profile classification (7 profiles). Many commercial and industrial customers at the primary voltage level or above are interval metered; those that aren t interval metered are assigned the primary, primary-substation or high voltage load profiles (3 profiles). The street lighting/outdoor lighting segment represents its own profile class. Because this segment is unmetered, the street lighting/outdoor lighting profile was developed as a deemed profile that recognizes the changes in sunset and sunrise, and daylight savings time (1 profile). The school rate class represents its own profile class for those accounts that do not have interval metering (1 profile). The traffic signal rate class represents its own profile class. Because this segment is unmetered, the traffic signal profile was developed as a deemed profile based on the assumption that traffic signals exhibit no hourly variation (1 profile). A table containing each DP&L load profile class, the associated load profile code, and a description of each class, is provided below. 2 of 10

Load Profile Class Code Description Residential No Heat Default RS00 Residential No Heat Default Residential No Heat Low kwh RS01 Residential No Heat <= 7200 annual kwh Residential No Heat High kwh RS02 Residential No Heat > 7200 annual kwh Residential Heat RH01 Residential Heat Secondary Default SS00 Secondary Default Secondary Low kw Low LF SS01 Secondary Low kw and <= 33% Summer Load Factor Secondary Low kw High LF SS02 Secondary Low kw and > 33% Summer Load Factor Secondary Med kw Low LF SS03 Secondary Medium kw and <= 38% Summer Load Factor Secondary Med kw High LF SS04 Secondary Medium kw and > 38% Summer Load Factor Secondary High kw Low LF SS05 Secondary High kw and <= 61% Summer Load Factor Secondary High kw High LF SS06 Secondary High kw and > 61% Summer Load Factor Primary PR01 Primary Primary Substation PS01 Primary Substation High Voltage HV01 High Voltage Street Lighting SL01 Street Lighting Schools SC01 Schools Traffic Signals TS01 Traffic Signals Secondary Low/Medium/High kw Breakdown: Low Medium High < 5 kw >= 5 kw < 150 kw >= 150 kw Profile Class Models Historical load research data was used to develop the profile segments. The historical data was then expanded to the current population to generate current population profiles. Seventeen profile models were developed from these average customer profiles. The profile models are executed on a daily basis to estimate the settlement day profile (based on actual calendar and weather data). DP&L s daily profiling process is composed of two steps: 1. Prior day and forecasted information is extracted (i.e. weather data) and imported into the profiling system. 2. The profiling models read weather and calendar information and generate a use-percustomer hourly profile for each profile class. 3 of 10

Weather Variables The profile models utilize the following weather variables: Cooling Degree Hours 60 F (CDH60) The number of degrees that an hour s temperature is above 60 Fahrenheit. This weather variable gives an indication of how much cooling a building might need on a day that is warmer than normal. Cooling Degree Hours 60 F 24 Hour Moving Average (CDH60_MA24) The previous 24 hour moving average of the number of degrees that an hour s temperature is above 60 Fahrenheit. This weather variable gives an indication of how much cooling a building might need on a day that is warmer than normal. Cooling Degree Hours 60 F 3 Hour Moving Average (CDH60_MA3) The previous 3 hour moving average of the number of degrees that an hour s temperature is above 60 Fahrenheit. This weather variable gives an indication of how much cooling a building might need on a day that is warmer than normal. Cooling Degree Hours 65 F (CDH65) The number of degrees that an hour s temperature is above 65 Fahrenheit. This weather variable gives an indication of how much cooling a building might need on a day that is warmer than normal. Cooling Degree Hours 65 F 24 Hour Moving Average (CDH65_MA24) The previous 24 hour moving average of the number of degrees that an hour s temperature is above 65 Fahrenheit. This weather variable gives an indication of how much cooling a building might need on a day that is warmer than normal. Cooling Degree Hours 65 F 3 Hour Moving Average (CDH65_MA3) The previous 3 hour moving average of the number of degrees that an hour s temperature is above 65 Fahrenheit. This weather variable gives an indication of how much cooling a building might need on a day that is warmer than normal. Cooling Degree Hours 70 F (CDH70) The number of degrees that an hour s temperature is above 70 Fahrenheit. This weather variable gives an indication of how much cooling a building might need on a day that is warmer than normal. Cooling Degree Hours 75 F (CDH75) The number of degrees that an hour s temperature is above 75 Fahrenheit. This weather variable gives an indication of how much cooling a building might need on a day that is warmer than normal. 4 of 10

Heating Degree Hours 30 F (HDH30) The number of degrees that an hour s temperature is below 30 Fahrenheit. This weather Heating Degree Hours 40 F (HDH40) The number of degrees that an hour s temperature is below 40 Fahrenheit. This weather Heating Degree Hours 45 F (HDH45) The number of degrees that an hour s temperature is below 45 Fahrenheit. This weather Heating Degree Hours 50 F (HDH50) The number of degrees that an hour s temperature is below 50 Fahrenheit. This weather Heating Degree Hours 55 F 24 Hour Moving Average (HDH55_MA24) The previous 24 hour moving average of the number of degrees that an hour s temperature is below 55 Fahrenheit. This weather variable gives an indication of how much heating a building might need on a day that is Heating Degree Hours 60 F (HDH60) The number of degrees that an hour s temperature is below 60 Fahrenheit. This weather Heating Degree Hours 60 F 24 Hour Moving Average (HDH60_MA24) The previous 24 hour moving average of the number of degrees that an hour s temperature is below 60 Fahrenheit. This weather variable gives an indication of how much heating a building might need on a day that is Heating Degree Hours 65 F (HDH65) The number of degrees that an hour s temperature is below 65 Fahrenheit. This weather Model Format The profile classes use the modeling approaches described below: 5 of 10

Hourly Weather Sensitive Model In this modeling approach, a linear regression of historical weather data is run against the generic profiled loads from the load research study. It consists of a series of regression equations expressing the relationship between certain weather variables, seasons, day types and loads. The relationship is a piece-wise linear regression whose parameters are estimated using a search algorithm. The algorithm identifies the optimal breakpoints for the regression lines in order to ensure the best possible statistical fit to the historical load data. For each hourly regression, the model generates load profiles forecasted according to that hour s actual conditions. o Variables used per profile class: HV01 o CDH65, CDH65_MA24, CDH65_MA3, CDH75 & HDH60 PR01 o CDH65, CDH65_MA24, CDH65_MA3, HDH30, HDH40, HDH50, HDH60 & HDH60_MA24 RH01 o Sunday/Holiday & Saturday o Monday Friday (baseline) o CDH65, CDH65_MA24, CDH65_MA3, CDH75, HDH30, HDH40, HDH50, HDH60 & HDH60_MA24 RS00 6 of 10

o Sunday/Holiday & Saturday o Monday Friday (baseline) o CDH65, CDH65_MA24, CDH65_MA3, CDH75, HDH30, HDH40, HDH50, HDH60 & HDH60_MA24 RS01 o Sunday/Holiday & Saturday o Monday Friday (baseline) o CDH65, CDH65_MA24, CDH65_MA3, HDH30, HDH40, HDH50, HDH60 & HDH60_MA24 RS02 o Sunday/Holiday & Saturday o Monday Friday (baseline) o CDH65, CDH65_MA24, CDH65_MA3, CDH75, HDH30, HDH40, HDH50, HDH60 & HDH60_MA24 SC01 o January, February, March, April, May, September, October, November & December o June August (baseline) o Sunday/Holiday & Saturday o Monday Friday (baseline) o CDH60, CDH65, CDH65_MA24, CDH65_MA3, CDH75, HDH40, HDH50, HDH60 & HDH60_MA24 SS00 7 of 10

o CDH65, CDH65_MA24, CDH65_MA3, CDH75, HDH45, HDH55_MA24, HDH60 & HDH65 SS01 o CDH65, CDH65_MA24, CDH65_MA3, HDH40, HDH50, HDH60 & HDH60_MA24 SS02 o CDH65, CDH65_MA24, CDH65_MA3, CDH75 & HDH60 SS03 o CDH65, CDH65_MA24, CDH65_MA3, CDH75 & HDH60 SS04 8 of 10

o CDH60, CDH60_MA24, CDH60_MA3, HDH45, HDH55_MA24 & HDH65 SS05 o CDH65, CDH65_MA24, CDH65_MA3, HDH40, HDH50, HDH60 & HDH60_MA24 o HDH55_MA24 & HDH65 SS06 o CDH60, CDH60_MA24, CDH70, HDH40, HDH50, HDH60 & HDH60_MA24 12 Season / 3 Day Type Model (No Weather Sensitivity) The PS01 profile class uses the 12 Season / 3 Day Type modeling approach. This model does not use any weather variables since the few customers assigned to this class have high consumption and are not very sensitive to changes in weather. The model instead uses 36 regression models for each hour to forecast the kw consumption by month and day type. 12 Season / 1 Day Type Model (No Weather Sensitivity) The SL01 profile class represents street light and outdoor lighting customers. Because these types of customers are not weather sensitive, the profiles use day type models with only seasonal/monthly variables. The model uses 12 regression models for each hour to forecast the kw consumption. 1 Season / 1 Day Type Model (No Weather Sensitivity) The TS01 profile class represents traffic signals. The model for this class uses a constant kw value for each hour that is consistent across all seasons and day types. 9 of 10

Profile Class Model Formats Model Model Format HV01 Hourly Weather Sensitive Model PR01 Hourly Weather Sensitive Model PS01 12 Season / 3 Day Type Model RH01 Hourly Weather Sensitive Model RS00 Hourly Weather Sensitive Model RS01 Hourly Weather Sensitive Model RS02 Hourly Weather Sensitive Model SC01 Hourly Weather Sensitive Model SL01 12 Season / 1 Day Type Model SS00 Hourly Weather Sensitive Model SS01 Hourly Weather Sensitive Model SS02 Hourly Weather Sensitive Model SS03 Hourly Weather Sensitive Model SS04 Hourly Weather Sensitive Model SS05 Hourly Weather Sensitive Model SS06 Hourly Weather Sensitive Model TS01 1 Season / 1 Day Type Model Generic Interval Class Profiles Accounts with interval meters are assigned a generic interval class profile according to its voltage level of service. However, a unique profile is established for each interval account to be used for PJM settlements. The unique profile model for load settlements is generated using actual hourly usage history for each account. See below for the list of generic interval class profiles. Load Profile Class Code Description INT-HIGH VOLTAGE IHV1 All interval meter high voltage class accounts INT-PRIM LOW LD FCTR IPR1 Interval meter primary class accounts with annual average load factors less than or equal 65% INT-PRIM HI LD FCTR IPR2 Interval meter primary class accounts with annual average load factors greater than 65% INT-PRIM SUB IPS1 All interval meter primary substation class accounts INT-SEC LOW LD FCTR ISS1 Interval meter secondary class accounts with annual average load factors less than or equal 65% INT-SEC HI LD FCTR ISS2 Interval meter secondary class accounts with annual average load factors greater than 65% 10 of 10