SUPPLEMENTAL INFORMATION. Real-time Measurement of Biomagnetic Vector Fields in Functional Syncytium Using Amorphous Metal

Similar documents
STATIC TORQUE MEASUREMENT USING GMI STRAIN GAUGE

Electromagnetics in Medical Physics

Chapter 15 Magnetic Circuits and Transformers

CHAPTER 2. COULOMB S LAW AND ELECTRONIC FIELD INTENSITY. 2.3 Field Due to a Continuous Volume Charge Distribution

AP Physics Electromagnetic Wrap Up

Nature Neuroscience: doi: /nn.2283

15 Inductance solenoid, shorted coax

Single-phase Transistor Lab Report. Module: EEE 108

DIRECTIVITY AND SENSITIVITY OF HIGH FREQUENCY CARRIER TYPE THIN-FILM MAGNETIC FIELD SENSOR

Louisiana State University Physics 2102, Exam 3 April 2nd, 2009.

Tutorial Sheet IV. Fig. IV_2.

Reactor Characteristic Evaluation and Analysis Technologies of JFE Steel

General Physics (PHY 2140)

CURRENT-CARRYING CONDUCTORS / MOVING CHARGES / CHARGED PARTICLES IN CIRCULAR ORBITS

Louisiana State University Physics 2102, Exam 3, November 11, 2010.

What happens when things change. Transient current and voltage relationships in a simple resistive circuit.

Chapter 2: Fundamentals of Magnetism. 8/28/2003 Electromechanical Dynamics 1

Magnetic Forces and Fields

Development of a Compressor for a Miniature Pulse Tube Cryocooler of 2.5 W at 65 K

Figure 1: Alternator front view.

Concept Questions with Answers. Concept Questions with Answers W11D2. Concept Questions Review

Study of Electromagnetic Induction

Faults Detection in Metallic Tubes Using Eddy Current

Møller Polarimetry in Hall A and Beyond

CHAPTER 6. Inductance, Capacitance, and Mutual Inductance

Magnetic Force on a Moving Charge

REVIEW SESSION. Midterm 2

Magnetic Field Penetration Into a Conducting Hohlraum

Lecture 3 Fiber Optical Communication Lecture 3, Slide 1

TitleCoupled Nosé-Hoover Equations of Mo.

Last Revision: August,

ELECTROMAGNETIC FIELDS AND WAVES

ADVANCED FLUX-GATE MAGNETOMETERS WITH LOW DRIFT

Ch 30 - Sources of Magnetic Field

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

Surface Magnetic Non-Destructive Testing

Investigation of evolution strategy and optimization of induction heating model

EL-GY 6813/BE-GY 6203 Medical Imaging, Fall 2016 Final Exam

BROCK UNIVERSITY SOLUTIONS

Mathematical Modelling and Simulation of Magnetostrictive Materials by Comsol Multiphysics

Development of a Two-axis Dual Pendulum Thrust Stand for Thrust Vector Measurement of Hall Thrusters

Sensors: a) Gyroscope. Micro Electro-Mechanical (MEM) Gyroscopes: (MEM) Gyroscopes. Needs:

Chapter 21. Magnetism

Chapter 27 Sources of Magnetic Field

Mechanical and Electrical Oscillations of a Superconductor Coil and its. Departamento de Física, Universidade Federal de Santa Catarina, Campus,

Can a Magnetic Field Produce a Current?

Inductance and Magnetic Energy

Chapter 28 Sources of Magnetic Field

Kirchhoff s rules, example

SKIN EFFECT : ELECTROMAGNETIC WAVE OR DIFFUSION?

Revision Guide for Chapter 15

Functional quantum nodes for entanglement distribution

Displacement Current. Ampere s law in the original form is valid only if any electric fields present are constant in time

Electric and magnetic fields, microwave therapy

EXPERIMENTS CHARACTERIZING THE X-RAY EMISSION FROM A SOLID-STATE CATHODE USING A HIGH-CURRENT GLOW DISCHARGE

Physics 102, Learning Guide 4, Spring Learning Guide 4

SUPPLEMENTARY INFORMATION

The steady state magnetic resonance absorption signal: a common. Department of Physics, University of Utah, 115 S E.

The Effects of Noise and Time Delay on RWM Feedback System Performance

3d magnetostatic analysis of magneto-inductive devices for ndt

The Magnetic Field

Chapter 28 Sources of Magnetic Field

Inductors Maxwell s equations

MAGNETIC FIELDS & UNIFORM PLANE WAVES

Gravity Electromagnetism Weak Strong

Electromagnetic Acoustic Transducers for In and Out of plane Ultrasonic Wave Detection

Resistivity (mohm-cm) Magnetoresistance (%) H=0 T H=1 T MR. Temperature (K)

2.1 The electric field outside a charged sphere is the same as for a point source, E(r) =

Physics 111. Exam #1. February 14, 2014

Physics 208 Final Exam December 15, 2008

Lecture 22. Inductance. Magnetic Field Energy.

Physics 201. Professor P. Q. Hung. 311B, Physics Building. Physics 201 p. 1/1

CHAPTER 20 Magnetism

N H I. 3.2 l When a conducting coil is placed in a magnetic field, the magnetic flux is

Technical University of Denmark

MOCK cet paper II 2012 (PHYSICS)

Chapter 1 Magnetic Circuits

Accelerated Taylor State Plumes in SSX

Lightning Phenomenology Notes Note 23 8 Jan Lightning Responses on a Finite Cylindrical Enclosure

Exam 2, Phy 2049, Spring Solutions:

Chapter 22, Magnetism. Magnets

Dynamics of Drift and Flute Modes in Linear Cylindrical ECR Plasma

Introduction to Electromagnetic Theory

Chapter 30. Inductance

cancel each other out. Thus, we only need to consider magnetic field produced by wire carrying current 2.

General Physics II. Electromagnetic Induction and Electromagnetic Waves

4 Spin-echo, Spin-echo Double Resonance (SEDOR) and Rotational-echo Double Resonance (REDOR) applied on polymer blends

MAGNETIC EFFECT OF CURRENT

Non-Linear Response of Test Mass to External Forces and Arbitrary Motion of Suspension Point

Texas A & M University Department of Mechanical Engineering MEEN 364 Dynamic Systems and Controls Dr. Alexander G. Parlos

Solve: From Example 33.5, the on-axis magnetic field of a current loop is

Exp. #2-4 : Measurement of Characteristics of Magnetic Fields by Using Single Coils and a Computer Interface

Finite Element Model of a Magnet Driven Reed Switch

FARADAY S AND LENZ LAW B O O K P G

ENGR 2405 Chapter 6. Capacitors And Inductors

PHYS 1444 Section 003 Lecture #18

8/24/2006 Faraday ( F.Robilliard) 1

Homework 6 solutions PHYS 212 Dr. Amir

1 (a) Define magnetic flux [1]

Chapter 1 The Electric Force

Transcription:

SUPPLEMENTAL INFORMATION Real-time Measurement of Biomagnetic Vector Fields in Functional Syncytium Using Amorphous Metal By Shinsuke Nakayama* and Tusyoshi Uchiyama From *Department of Cell Physiology, Nagoya University Graduate School of Medicine, Nagoya 466-8550, Japan. Department of Electronics, Nagoya University of Graduate School of Engineering, Nagoya 464-8603, Japan *Corresponding author: Shinsuke Nakayama Department of Cell Physiology, Nagoya University Graduate School of Medicine, 65 Tsuruma-cho, Showa-ku, Nagoya 466-8550, JAPAN Phone: +81 52 744 2045 Fax: +81 52 744 2048 E-mail: h44673a@nucc.cc.nagoya-u.ac.jp 1

List of Supplemental Information: Figure S1: The principle of magneto sensor. Figure S2: Amplitude histograms. Figure S3: Inhibitory effect of nifedipine on biomagnetic waves. Figure S4: Changes in biomagnetic field direction depending on the direction. Figure S5: Computer simulation of a biomagnetic vector field. Figure S6: Computer simulation of a biomagnetic vector field shown in logarithmic scale. Figure S7: Changes in magnetic field depend on the z-distance in the two sets of model circuits. Appendix: A simple model circuit for estimating biomagnetic fields. 2

Figure S1 The principle of a magneto sensor. Panels show how a magnetic field along the wire axis (B A ) is converted to a coil potential (E coil ) in a pulse-driven magneto sensor constructed with a magnetic amorphous wire (Am) and a transducer coil. (a) The periods of control (environmental magnetic fields: B ENV ) and biomagnetic fields (B BIO ) added during excitation pulses were repeated at the same intervals (2 μs). (b) Internal magnetization of Am wire and changes in E coil. Every excitation pulse (P e ) shifts the texture of internal magnetizations to a certain state and the distribution of internal magnetizations returns to an initial state after cessation of P e during pulse off time. Thus, the peak amplitude of E coil (t) reflects changes in magnetizations in the presence of a biomagnetic field (pink). A sample/hold (SH) circuit detects the biomagnetic field in a quasi-real-time manner, because of the short interval of P e repetition. 3

Supplemental Explanation of Magneto Detection Mechanisms in Figure S1. The exact mechanisms by which pulse-driven amorphous metal-based magneto sensors detect a magnetic field with high sensitivity, are not fully understood, but the principle of the underlying mechanisms currently considered is as follows (Figure S1). 1) Unlike ordinary metals, magnetic amorphous wires of a non-crystalline structure contain internal magnetizations of electron spins whose texture is easily shifted by exposing them to external magnetic fields. 2) In our magneto sensor systems operated by an excitation pulse, electric current pulses (P e ) conduct through the amorphous wire at a constant interval of several μs. Thereby, during excitation (pulse-on period), whole internal magnetizations are shifted to a certain texture following the circumferential magnetic field induced by the surface and/or internal excitation current, and the detector coil surrounding the amorphous wire detects induction potentials which are caused by the shift of magnetizations along the wire axis. 3) The amplitude of induction potential thus reflects the external magnetic field as a difference of the texture of internal magnetizations along the wire axis between the electric pulse-on and off periods. When biomagnetic fields are added to environmental geomagnetism, the induction potential of the detector coil reflects the changes in the magnetization texture for the additional biomagnetic fields. (To simplify the explanation of the detection mechanism, magnetic domain structure is not considered in amorphous metal wires.) 4) In the amorphous wire which we use, the time constant for relaxation of internal magnetizations appears to be short enough (< 100 ns: Fig. 1 f) to repeatedly apply excitation pulses at intervals of several μs. Thus, the interval of sampling the magnetic field is sufficiently short compared to electric activities in living systems, and enables biomagnetic fields to be detected in a quasi-real-time manner. 4

Figure S2 Amplitude histograms. The recordings of ileal biomagnetic waves in Fig. 3 b, c and d were used, respectively. Off-line band elimination filter (BEF) was not applied. Red curves represent cumulative percentages (%) of the histograms. Bin width = 20 pt. Similar histogram analyses may be useful to quantify the biomagnetic activity in other samples (e.g. use of the amplitude at 50%). Figure S3 Inhibitory effect of nifedipine on biomagnetic waves. After observing biomagnetic waves in an ileal muscular preparation, 1 μm nifedipine, an L-type Ca 2+ channel blocker, was applied. Panels a and b show three sequential recordings of biomagnetic waves for ~3 min, before and after application of nifedipine, respectively. The sample was mounted on the chamber in the serosal side down, crossing the magneto sensor from the oral to anal side (O A). Note that nifedipine nearly completely suppressed biomagnetic waves, leaving only marginal waves (red arrowheads). 5

Figure S4 Changes in biomagnetic field direction depending on the direction of the stomach musculature. In a-d, the direction of the same stomach musculature sample crossing the magneto sensor was alternated in lesser-to-greater (L G) and greater-to-lesser (L G) curvature ends. 6

Figure S5 Computer simulation of a biomagnetic vector field. (a) The same simplified 7

circuits in Fig. 6 b were used for simulation of biomagnetic vector fields. Five electric circuits (L -2 to L 2 ) are combined and a 1 μa current is conducted in each circuit. (b-d), Biomagnetic vector field maps of L z = 0.2, 0.5 and 1 mm. Top, middle and bottom maps represent x, y and z magnetic vector fields (M x, M y, M z ), respectively. Note that M y is predominant in this model. To save space, scalar magnetic fields are shown in Fig. 6 c. Figure S6 Computer simulation of a biomagnetic vector field shown in logarithmic scale. Biomagentic vector field was estimated using the same electric circuits shown in Fig. S5. The y magnetic vector field (M y ) is shown, because of dominant effect. 8

Figure S7 Changes in magnetic field depend on the z-distance in the two sets of model circuits. (a, b) The amplitude of a magnetic field is plotted against the z-distance (from 250 μm to 20 mm) toward the bottom, in linear and logarithmic scales, respectively. The red model in a is the same as those in Fig. 6 b and Fig. S3 a, except the x-length (from 500 to 500 μm). The z- distance of the intercellular and return current is 200 μm in each circuit. Continuous lines represent the propagating intercellular current, while dotted lines are the return current. The blue model is composed of eight circuits with a 1 μa current conducted in each circuit. In b, note that the magnetic field of the computer model (red) used similar to that in Fig. 6 b declines to 30 ft at 15 mm below the origin O. In the second model (blue) with an intercellular current symmetrically surrounded by return currents, the magnetic field declines more rapidly with distance. When the intercellular current position is shifted from the centre (z = 0) to 150 μm, the decrease in the magnetic field is slowed similar to the red model circuit: 21 ft at 15 mm (data not shown). 9

Appendix A simple model circuit for estimating biomagnetic fields. To understand how the distance between intercellular propagating current and extracellular return current affect measurement of biomagnetic fields, the model circuit in Fig. 6 is simplified as a rectangular circuit with the current segments (a) and (2b). The two segments (2b) represent the intercellular propagating current in cellular organization and the accompanying extracellular return current, respectively. The length of the segment (a) corresponds to the distance between intercellular propagating current and extracellular return current (i.e. thickness of a bioelectric circuit). The segment (r) represents the distance between magneto sensor and bioelectric circuit. The sensor is placed at (P) in the center of the current segment (2b). The intensity of the magnetic field at P (H P ) is described as the sum of the intensity of magnetic fields: H P = H iv + H ip, (Eq1) where H iv and H ip are of the magnetic fields induced by electric currents vertical to and parallel with the segment (r), (corresponding to (2b) and (a) current segments), respectively. Note that 10

magnetic fields are expressed as magnetic flux density (B) in this paper. So, the equations of magnetic field density (H) in this section need to be converted with the magnetic permeability in space (i.e. B = µ 0 H) The intensity of the magnetic field induced by each current segment of the rectangular circuit above is estimated by using the following formula: H = (i /4πr) (cosθ 1 + cosθ 2 ), (Eq2) where (i) represents the amplitude of the linear electric current segment (AB), and (r) represents the distance between the observation point (P) and the current segment. θ 1 and θ 2 are the angles of (A) and (B). The direction toward the reverse side from the right side of this paper is defined as positive in the magnetic field of the equation. In the simple bioelectric circuit, since the line segment (r) intercepts the segment (2b) at the center, cosθ 1 equals cosθ 2. Thus, H iv and H ip are expressed as a function of (a), (b) and (r): H iv = (b i /2π) [1 / {r (r 2 + b 2 )} - 1 / {(r + a) ((r + a) 2 + b 2 )}], H ip = (- i /2πb) [(r + a) / { ((r + a) 2 + b 2 )} - r / { (r 2 + b 2 )}], (Eq3) (Eq4) When (r)» (a), (r + a) (r): This corresponds to a condition of measurement in which the magneto sensor used is largely separated from the bioelectric circuit in the cellular organizations, despite a small distance between the intercellular and extracellular currents. Under this condition, the magnetic fields H iv and H ip become naught. Thus, in order to measure sufficient magnetic field, it is necessary to keep the sensor with the distance (r) comparable to (a). When the sensor is mounted in a position where (r) and (a) are comparable, and when the distance of bioelectric current propagation (b) is sufficiently longer than both (r) and (a), the inside of the root thus becomes unit in the following equations derived from Eq3 and Eq4 by cancellations with (1/b): 11

H iv = (b i /2π) [(1/b) / {r ((r/b) 2 + 1)} - (1/b) / {(r + a) (((r + a) / b) 2 + 1)}], (Eq5) H ip = (-i /2πb) [(1/b) (r + a) / { (((r + a) / b) 2 + 1)} - (1/b) r / { ((r/b) 2 + 1)}]. (Eq6) With (r/b) and ((r + a)/ b) 0, these equations are simplified as: H iv = (i /2π) [1 / r - 1 / (r + a) ] = ( i /2π) [a / {r (r + a)}], (Eq7) H ip = (-i /2πb) [(1/b) (r + a) - (1/b) r] = (-i a / 2πb 2 ). (Eq8) In Eq8, when (b)» (a), H ip becomes naught, unless (i)» (b): Practically, the amplitude of the electric current (i) (in μa) is considered to be smaller than the length of (b) (in mm). This means that the contribution of parallel current is negligible, when the distance of electric current propagation is sufficiently long. Also, Eq7 indicates that the local magnetic field H P becomes nearly identical to H iv (H P H iv ), which is independent of the length (b), and is expressed as a function of the sensor distance (r) and circuit thickness (a). This condition corresponds to the experiments in Fig. 5. When Eq7 is further simplified by assuming (a)» (r), (a) / (r + a ) 1. Thus, H P = H iv = ( i /2πr). (Eq9) This equation is identical to Ampere s circuital law, and also corresponds to the experimental condition in Fig. 2. 12