SILVER NEUTRON ACTIVATION DETECTOR FOR MEASURING BURSTS OF 14 MEV NEUTRONS

Similar documents
STUDY ON THE ENERGY RESPONSE OF PLASTIC SCINTILLATION DETECTOR TO MEV NEUTRONS ABSTRACT

EEE4106Z Radiation Interactions & Detection

Introduction to Radiological Sciences Neutron Detectors. Theory of operation. Types of detectors Source calibration Survey for Dose

6th International Conference on Information Engineering for Mechanics and Materials (ICIMM 2016)

RADIOACTIVITY Q32 P1 A radioactive carbon 14 decay to Nitrogen by beta emission as below 14 x 0

DETECTORS. I. Charged Particle Detectors

INVESTIGATIONS OF NEUTRON EMISSION IN A COLD FUSION EXPERIMENT IN PALLADI UM

CHAPTER 12 TEST REVIEW

Radioactivity III: Measurement of Half Life.

Neutron Spectrum Measurement in a Medical Cyclotron

First on the South Pole, 14 December, 1911

Absorption and Backscattering ofβrays

A Report On DESIGN OF NEUTRON SOURCES AND INVESTIGATION OF NEUTRON BASED TECHNIQUES FOR THE DETECTION OF EXPLOSIVE MATERIALS

Introduction. Neutron Effects NSEU. Neutron Testing Basics User Requirements Conclusions

Science of Nuclear Energy and Radiation a Comprehensive Course for Science Teachers June 22-25, 1998 McMaster University

Measurements of Neutron Total and Capture Cross Sections at the TOF spectrometers of the Moscow Meson Factory

PARTICLES REVELATION THROUGH SCINTILLATION COUNTER

Quality Assurance. Purity control. Polycrystalline Ingots

Shielded Scintillator for Neutron Characterization

arxiv: v1 [physics.ins-det] 29 Jun 2011

Nuclear Physics and Astrophysics

ICTP-IAEA Joint Workshop on Nuclear Data for Science and Technology: Medical Applications. 30 September - 4 October, 2013

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Chapter 3: Neutron Activation and Isotope Analysis

Neutron Transport Calculations Using Monte-Carlo Methods. Sean Lourette Fairport High School Advisor: Christian Stoeckl

Cherenkov Detector. Cosmic Rays Cherenkov Detector. Lodovico Lappetito. CherenkovDetector_ENG - 28/04/2016 Pag. 1

A new neutron monitor for pulsed fields at high-energy accelerators

POSITION SENSITIVE DETECTION OF CONCEALED SUBSTANCES EMPLOYING PULSED SLOW NEUTRONS

2. Which of the following statements help(s) to explain why gas can fill the vessel containing it completely while liquid cannot?

Recent Activities on Neutron Standardization at the Electrotechnical Laboratory

REFERENCE SOURCES FOR THE CALIBRATION OF THE AUTOCORRELATION SINGLE-CRYSTAL SCINTILLATION TIME SPECTROMETER

SCINTILLATION DETECTORS AND PM TUBES

Cross Calibration for using Neutron Activation Analysis with Copper Samples to measure D-T Fusion Yields

Absolute activity measurement

Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes

A Monte Carlo Simulation for Estimating of the Flux in a Novel Neutron Activation System using 252 Cf Source

Photoneutron Interrogation of Uranium Samples by a 4 MeV LINAC. A Feasibility Study

Distinguishing fissions of 232 Th, 237 Np and 238 U with beta-delayed gamma rays

Activation Analysis. Characteristic decay mechanisms, α, β, γ Activity A reveals the abundance N:

Experimental Studies on the Self-Shielding Effect in Fissile Fuel Breeding Measurement in Thorium Oxide Pellets Irradiated with 14 MeV Neutrons

UNIQUE SCIENCE ACADEMY

Absorption and Backscattering of β-rays

Deuteron activation cross section measurements at the NPI cyclotron

Radiation Detection and Measurement

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Neutron collimator design of neutron radiography based on the BNCT facility arxiv: v1 [physics.ins-det] 3 May 2013

Measurement of Average Thermal Neutron Flux for PGNAA Setup

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

EXPERIMENTAL STUDY OF NEUTRON FIELDS PRODUCED IN PROTON REACTIONS WITH HEAVY TARGETS. Nuclear Physics Institute AS CR, Rez Czech Republic

Diagnostic Capabilities of Line-Integrated Neutron Pulse Height Spectra Measurements

Detekce a spektrometrie neutronů. neutron detection and spectroscopy

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

RADIATION DETECTION AND MEASUREMENT

Neutron capture cross sections on light nuclei

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Radiation Detection. 15 th Annual OSC Readiness Training Program.

ICF Burn-History Measurements Using 17-MeV Fusion Gamma Rays

Measurements of liquid xenon s response to low-energy particle interactions

Radiation Detection and Measurement

DESIGN OF NEUTRON DOSE RATE METER FOR RADIATION PROTECTION IN THE EQUIVALENT DOSE

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

Introduction to neutron rem meters

Fast Neutron Imaging for SNM Detection

Neutron TOF spectroscopy in a single-shot nanosecond neutron pulsed technique for a disclosure of hidden explosives and fissile materials

Plasma Accelerator for Detection of Hidden Objects by Using Nanosecond Impulse Neutron Inspection System (NINIS)

New Scintillators for the Border Monitoring Equipment

APPROVED FOR PUBLIC RELEASE i. LOS ALAMOS SCIENTIFIC LABORATORY of the UNIVERSITY OF CALIFORNIA. This document consists of 22 pages

Chemical Engineering 412

Neutronics Experiments for ITER at JAERI/FNS

ENT OF THE RATIO OF FISSIONS IN U TO FISSIONS OF. IN U USING 1.60 MEV GAMMA RAYS THE FISSION PRODUCT La 14 0 MEASUREM

Elastic Recoil Detection Method using DT Neutrons for Hydrogen Isotope Analysis in Fusion Materials. Abstract

Results from Silicon Photo-Multiplier neutron irradiation test

APEX CARE INSTITUTE FOR PG - TRB, SLET AND NET IN PHYSICS

Update on Calibration Studies of the Canadian High-Energy Neutron Spectrometry System (CHENSS)

Powerful Nanosecond Single- Shot Technique for Detection of Illicit Materials and Explosives

Neutron Detection. n interactions with matter n detection High/low energy n detectors

The Ones That Got Away: Neutron Leakage Spectra

Neutronics experiments for validation of activation and neutron transport data for fusion application at the DT neutron generator of TU Dresden

Photofission of 238-U Nuclei

Contrabands detection with a low energy electron linac driven photoneutron source

anti-compton BGO detector

Chapter Seven (Nuclear Detectors)

Determination of Absolute Neutron Fluence to sub-0.1% uncertainty (and better)

Name: Class: Date: SHORT ANSWER Answer the following questions in the space provided.

A Project for High Fluence 14 MeV Neutron Source

5 Atomic Physics. 1 of the isotope remains. 1 minute, 4. Atomic Physics. 1. Radioactivity 2. The nuclear atom

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

At the conclusion of this lesson the trainee will be able to: a) Write a typical equation for the production of each type of radiation.

Measurement of prompt fission γ-ray spectra in fast neutroninduced

Recent Activities on Neutron Calibration Fields at FRS of JAERI

M.J. CIESLAK, K.A.A. GAMAGE Department of Engineering, Lancaster University Lancaster, LA1 4YW United Kingdom ABSTRACT

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

Neutron Activation Cross Sections for Fusion

Status report of CPHS and neutron activities at Tsinghua University

PROGRESS OF NUCLEAR DATA MEASUREMENT IN CHINA

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Survey Meter OD-01 Address: Phone: Fax: URL:

Nuclear Reactions A Z. Radioactivity, Spontaneous Decay: Nuclear Reaction, Induced Process: x + X Y + y + Q Q > 0. Exothermic Endothermic

MEASUREMENTS OF PARTICULE EMISSION SPECTRA IN PROTON INDUCED REACTIONS OF INTEREST FOR THE DEVELOPMENT OF ACCELERATOR DRIVEN SYSTEMS

SCIENCE CHINA Physics, Mechanics & Astronomy

Transcription:

SILVER NEUTRON ACTIVATION DETECTOR FOR MEASURING BURSTS OF 14 MEV NEUTRONS Song Zhaohui, Guan Xinyin, Zhang Zichuan Northwest Institute of Nuclear Technology, Xi an, 71004, China In order to measure bursts of 14 MeV neutrons, a silver neutron activation detector was designed. The detector was made up of neutron moderating material natural silver plastic scintillator and a PMT. The output current of the detector was recorded by a micro-current meter. By comparing and analyzing the differences between the output current curves of the detector which measured under the constant neutron generator and that of the pulsed neutron source, typical parameters were deduced. Then yields of bursts of 14 MeV neutrons could be calculated. This new method reduces the dependence of the cross-section data, and it is very simple and convenient to be used for on-line measurement. 1. Introduction It is important to measure the yield of 14 MeV neutrons accurately in DT fusion reactions. The measurement is helpful for the studies of ICF and Tokamak devices [1-]. Because of its simplicity and convenience, Neutron Activation Analysis (NAA) has become the most common method of measuring the neutron fields [3-4]. The basic principle of NAA is as follows: Firstly, adopting an appropriate thin sample; then the sample being irradiated by neutron, some of the nuclide will be activated and give off gamma rays; Secondly, putting the sample to semiconductor detector, such as a HPGe detector, in order to measure the intensity of these gamma rays. At last, the neutron yield can be calculated by the time and the activated cross-sections. This paper introduces another neutron activated method. The detector was made up of neutron moderating material natural silver plastic scintillator and a photo-multiplier tube (PMT). The output current of the detector was recorded by a micro-current meter. This method does neither need semiconductor detector to measure gamma rays off-line, nor need other equipments, such as main amplifier, discriminator and so on. So, it is simple and has few transition factors. It is suitable for measuring bursts of 14 MeV neutrons repeatedly.. Silver Neutron Activation Detector.1 Neutron Activation Reactions Cross-sections values for fast neutron reactions on silver isotopes are very low [5]. It is hard to measure 14 MeV neutrons directly when the yields are not high. Usually, it is necessary to convert fast neurons to thermal neutrons in order to use activation methods [6]. Nature silver includes 107 Ag and 109 Ag, the abundance of which are 51.8%, 48.18%,

respectively. The reactions of thermal neutrons activating nature silver and the half-lives of the products are as follows [7]: 109 Ag+n γ+ 110m Ag 110 Cd+β - (E β =.4 MeV or.8 MeV) ( T1 = 4. s, σ n, γ = 89 ± 4 b ) 107 Ag+n γ+ 108m Ag 108 Cd+β - (E β =1.49 MeV) ( T.4min, σ = 37 b ) 1 = n, γ ± 109 Ag+n γ+ 110m Ag 110 Cd+β - (E β =1.77 MeV) ( T1 = 5 d, σ n, γ = 4.7 ± 0. 4 b ) Obviously, the first and the second reactions play important roles in the neutron detections because of their shorter half-lives and larger cross-sections.. Internal Structures of the detector The silver neutron activation detector was made up of neutron moderating material natural silver plastic scintillator and a PMT. The nature silver foils were clipped between the plastic scintillators. It could be used to measure bursts of 14MeV neutrons in its linear range. The current of anode of PMT varied directly as time was recorded by a micro-current meter. Comparing with other detectors, it has very fast response, about 5 ns. So, it does not need make any corrections of dead time and discriminating time. The internal structure of the detector is described as follows: 9 pieces of natural silver foils (150 10 0.5mm 3 for each piece) 10 pieces of ST401 plastic scintillaor (150 10 3mm 3 for each piece) a cone-shaped light guide and a PMT. Each piece of foil was clipped by two pieces of plastic scintillaor like a sandwich. Outside the sandwich, there was a sheath made up of cadmium foil. The thickness of the cadmium foil was 1.5mm. It was used to reduce the effects of the scattered neutrons of the surroundings. Outside the cadmium sheath was 0mm boron-doped polythene. The sketch of internal structure of the silver-activated detector is shown as figure 1.

Fig.1 Sketch of the structure of the silver-activated detector The sensitivity of the silver neutron activation detector could be adjusted to a certain extent by changing the numbers or the sizes of the silver foils, or varying the thickness of neutron moderator. As it is known, when the detector is relative far from the neutron source, scattered neutrons would be the main factor of backgrounds [8]. Large contributions of the scattered neutrons would increase the dependents of the calibration results to the environments. This would increase the uncertainties of the final results of the detector applied in a new environment. So, the detector should be set up in a shielded cylinder made of 10cm polythene in order to decrease the effect of backgrounds..3 Efficiency Calibration It is difficult to calculate the neutron flux by using cross-section datum directly. Because when the fast neutron interacted with the moderator, the energy spectrum becomes more complicated. It is hard to find a standard pulsed neutron source for calibration. But it can be calibrated directly against an absolute technique using a steady current neutron generator by accelerating D + particles to interact with 3 H. The reaction is written as: D+T 4 He+n+17.6 MeV (E n =14 MeV) The sketch of efficiency calibration of the silver-activated detector is shown as figure.

Fig. Sketch of efficiency calibration of the silver-activated detector In order to determine the detection efficiency, the neutron generator was turned on and kept with a constant intensity. (The measurement uncertainty of the intensity was less than 5%). The exposure time must be larger than 150 seconds in order to let 110 Ag (half-life:4.s) activation and decay be approximate to a balance. Then, the neutron generator was turned off immediately. The current of anode of PMT varied directly as time was recorded by a micro-current meter. An automatic data collection program was developed by using TESTPOINT software development platform. Real-time data was transmitted to a remote computer by using IEEE-488 card. So, a series of files including current data versus varied time could be got in the computer. So, beta decays of the nature silver were reflected by these files. The recorded time usually was set to 400~600 seconds so that the later analyses would become very convenient. The neutron flux was absolutely measured by the associated particle method [9]. A typical sequence of the efficiency calibration is shown as Figure 3. Fig.3 Output current as a function of time at the time of efficiency calibration The working process of the silver-activated detector was reflected by the current data varied as time. Firstly, only background current; then when the neutron generator was turned on, the current was raised sharply to a high platform and kept stable for a while. This was owed to the fluorescence of the recoiled proton and beta decays. After the neutron generator was turned off, the current was not deduced sharply as the same raising slope. But down sharply to a certain value then was decreased slowly. At this time, the beta decays of nature silver could be observed clearly. From the reactions described above, the decay process was divided into two parts: 110 Ag ( T = 4. s, fast) and 108 Ag ( T.4 min 1 1 =, slow).

When the neutron generator was turned off, the output current of the detector could be expressed as: λ ( t t 1 0) λ ( t t 0) 1 I() t = I e + I e + I b (1) where:λ 1 the decay constant of 110 Ag,.86 10 - s -1. λ the decay constant of 108 Ag,4.81 10-3 s -1. t 0 the moment of the neutron was turned off, s. I b background current, na. I 1 I undetermined coefficients, na. The current data recorded can be fitted by Formula (1). The parameters: I b I 1 and I are determined by Least-Square methods. The detection efficiency is defined by the decay rate of 110 Ag: where:φ-the neutron flux incident to the detector, n/cm. I 1 ε = () φ I 1 -the same meaning as Formula (1). At the above definition, it was assumed that the duration of the burst of 14 MeV neutrons must be far less than the fasted decay time of the detector, i.e. 1/λ1. Usually, the duration of the burst was less than 5μs, and 1/λ1 is 34.91s. In other words, the silver neutron activation detector was valid to be used in a very short time burst, no more than 1s. Otherwise, the efficiency calibration could not be done by the method described above. After the efficiency having been got from the calibration by using a steady current neutron generator, the yields of bursts of 14 MeV neutrons could be calculated by using the silver-activated detector and Formula (). The efficiency calibration has been done three times. After data processing, the average of the detection efficiency, ε=1.84 10 9 /na, was adopted. 3. Application DPF (Dense Plasma Focus) is a common pulsed neutron source at the laboratory. It could be operated repeatedly. It gives off 14MeV neutrons with the duration of 0~30 ns. The detector was designed to measure the neutron yield of this kind of single pulsed, DT fusion neutron source. Which should be pointed out was that there was an electrical-operated

mechanical shutter (with the diameter of 60mm). The shutter was closed firstly. It was used to avoid the PMT become saturated because of the high radio-fluorescence produced by the neutron beam in a short time. When the neutron beam passed, the shutter was opened. The relative zero-time was the time of which DPF was turned on. The measurement was performed at the neutron laboratory hall of Northwest Institute of Nuclear Technology, China. The detector was set up with the same position as it was calibrated. So, the distance from the source to the detector was fixed. A practical output current of the detector is shown as figure 4. Fig.4 Output current of silver-activated detector as a function of time at the time of measuring DPF neutron source Fitting the curve of Fig.4 according to formula (1), the parameter I 1 could be easily acquired. Then, it could be calculated through formula () that the yield of this burst of 14 MeV neutrons was: 8.74 10 9. According to the analysis, the measurement uncertainty was about 0% (k=). 4. Conclusion In order to measure bursts of 14 MeV neutrons, a silver neutron activation detector was designed. By comparing and analyzing the differences between the output current curves of the detector which measured under the constant neutron generator and that of the pulsed neutron source, typical parameters were deduced. Then yields of bursts of 14 MeV neutrons could be calculated. This detector is very simple and convenient to be used repeatedly. Acknowledgements The authors would like to thank the Intense Neutron Generator group at China Institute of Atomic Energy.

Reference [1] XU Jia-yun, BAI Li-xin, ZHANG Yi-yun, et al. Effect of target chamber-scattered neutrons on ICF neutron yield measurement accuracy by Pb activation[j], High Power Laser and Particle Beams, 004, 16(9) : 1143-1147 [] F.C. Young. Neutron Diagnostics for Pulsed Plasma Sources[J]. IEEE Trans. Nucl. Sci., 1975, NS-:718-73 [3] FENG Jie, WANG Dahai, YANG Cunbang, et al. γ-γcoincidence counting system of Cu activation measurement for fusion neutron yield[j]. High Power Laser and Particle Beams, 001,13(5): 599-60 [4] AI Jie, MA Jingfang, FAN Ruifeng, et al. Study of a kind of copper activation detector for low yield pulse neutron measurement[j]. Nuclear Electronics & Detection Technology, 009, 9(3): 550-553 [5] Junhua Luo,Fei Tuo, Xiangzhong Kong, et al. Activation cross-section for reactions induced by 14 MeV neutrons on natural silver. Annals of Nuclear Energy, 009, 36:718-7 [6] P.M. Dighe,K.R. Prasad, S.K. Kataria. Silver-lined proportional counter for detection of pulsed neutrons[j]. Nucl. Instr. and Meth. 004, A53, 158-16 [7] Handbook on Nuclear Activation Cross-Sections, IAEA, 1974 [8] GUO Zhigang, HAN Min,WANG Xin. Activation detection of the neutron yield from a DPF pulsed neutron source[j]. Journal of Tsinghua University ( Sci. and Tech.), 001, 41 (3):43-46 [9] ZHONG Qiping, CHEN Xiongjun, LU Hanlin, et al. Background analysis for an associated particle method to measure the neutron fluence rate from the T(d,n) 4 He neutron source, Atomic Energy Science and Technology, 005, 39(),131-133