ENHANCING SOLID-PHASE DISK EXTRACTION PERFORMANCE WITH DESIGN OF EXPERIMENTS

Similar documents
Sample Preparation. Approaches to Automation for SPE

Design of Experiments Helps Increase Yield of Pharmaceutical Intermediate from 70% to 88%

Perseverance. Experimentation. Knowledge.

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

Software Sleuth Solves Engineering Problems

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9.

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Highly automated protein formulation development: a case study

10/18/2006. Biotage A Life Science Technology Company

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Automation of Routine Microplate Pipetting and Dispensing

ION CHROMATOGRAPHY SYSTEM S 150

High-throughput Isolation of Genomic DNA From Buccal Swab on the Eppendorf epmotion 5075 VAC

Quantitative Analysis of Caffeine in Energy Drinks by High Performance Liquid Chromatography

[ Care and Use Manual ]

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

An automated synthesis programme for drug discovery

HPLC Sample Preparation

Contents...4. Solid phase extraction...8. Sample filtration Vials and caps Liquid chromatography Thin layer chromatography...

Scott Anderson, Kathy Lawrence Dennis McCreary, Melissa Wilcox. Grace Davison Discovery Sciences

Everyday NMR. Innovation with Integrity. Why infer when you can be sure? NMR

Using Design of Experiments to Optimize Chiral Separation

Consumables Guide for the Cannabis Testing Lab

ChiroSolve Enantiomer preparation for discovery, development and manufacturing

Sample Prep Options for GC users

Application Note 12: Fully Automated Compound Screening and Verification Using Spinsolve and MestReNova

USTER QUANTUM 3 APPLICATION REPORT. Comparison of the clearer generations THE YARN QUALITY ASSURANCE SYSTEM

Application Note PB 401. Improve HPLC Sample Preparation in an Analytical Laboratory A New Automated Sample Preparation Process

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

Innovation in. Motionless Mixers

ImprovIng ADmE ScrEEnIng productivity In Drug DIScovEry

NORBUPRENORPHINE (Buprenorphine s Metabolite ) BUPRENORPHINE in urine by GC/MS Code GC Method of Confirmation by GC-MS

Chemical Analysis Problem

Chromatography. What is Chromatography?

user manual blotting Hoefer PR648 Slot blot manifold um PR648-IM/Rev.F0/08-12

12 Nicarbazin Nicarbazin (4,4 -dinitro carbanilid (DNC) and 2-hydroxy-4,6-dimethyl pyrimidine (HDP))

Chapter content. Reference

Ideal and powerful solution

CHAPTER 1 Role of Bioanalytical Methods in Drug Discovery and Development

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Chromatography & instrumentation in Organic Chemistry

The Vaisala AUTOSONDE AS41 OPERATIONAL EFFICIENCY AND RELIABILITY TO A TOTALLY NEW LEVEL.

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

DEVELOP YOUR LAB, YOUR WAY

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

An Trinh, Todd Williams, and Daniel Vitkuske Supelco, 595 N. Harrison Rd., Bellefonte, PA, T GID

Quality control analytical methods- Switch from HPLC to UPLC

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - CHROMABOND. Catalogue 9. Hichrom Limited

ABI 3200 Q TRAP LC/MS/MS System

BIOO FOOD AND FEED SAFETY. Histamine Enzymatic Assay Kit Manual. Catalog #: Reference #:

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Automating Gradient Method Development in Flash Chromatography For Greater Productivity and Minimizing Solvent Use

Biofuels Series. Application Note 301LS RAPID MEASUREMENT OF XYLOSE AND GLUCOSE MONITORING CORN STOVER FERMENTATION IN BIOETHANOL PRODUCTION

[ a ppl ic at ion no t e ]

SIMPLICITY AND TECHNOLOGY THE LIASYS CLINICAL CHEMISTRY SYSTEMS FOR PHYSICIAN OFFICE LABORATORIES

Basic Principles for Purification Using Supercritical Fluid Chromatography

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Radio-HPLC Flow Cells

A powerful site for all chemists CHOICE CRC Handbook of Chemistry and Physics

Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

METHADONE and EDDP in urine by GC-MS Code GC Method of Confirmation by GC-MS

Reaxys Improved synthetic planning with Reaxys

PATENT PENDING. Easy Gripper product range. #94060 Easy Gripper #94095 Easy Gripper Compact Accessories. Improve SAFETY and efficiency

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

COC Biotechnology Program

Biotage 2012 Webinar series

Figure 1. The supported liquid extraction process using the ISOLUTE SLE plate (single well shown)

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

C HA R AC T E RIZ AT IO N O F INK J E T P RINT E R C A RT RIDG E INK S USING A CHEMOMETRIC APPROACH

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Care and Use Manual for Supelco Multi-Layer Silica Gel Column and Dual-Layer Carbon Reversible Column

96 Well? Done! Eppendorf epmotion 96 semi-automated electronic pipette for fast and precise 96 channel microplate processing

PROPERTIES OF MIXTURES. A mixture is a combination of two or more substances that are not chemically combined

Automating Wet Chemical Analysis. William Lipps Market Specialist for Water Analyzer Products December 11, 2008

Elemental Scientific. Stability. Elemental Scientific

High Performance Liquid Chromatography

Drug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F

ACETONE IN URINE BY UV CODE Z42010

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

For purification/separation of organic and aqueous phases from a two phase mixture within a 96 or 24 array tube system

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

AN-1301 APPLICATION NOTE

Shorten your Time-to-Result

Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Experiment Nine Thin Layer Chromatography

Identified a possible new offset location where the customer is currently exploring drill options.

Guide to Peptide Quantitation. Agilent clinical research

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

NEW! Your bacteria s favorite! Eppendorf Eporator

Quad-Z 215 with Disposable Tips: Implementing the Use of ZipTips for the Purification of Biological Samples

RediSep Rf C18 Flash Column Loading Techniques

Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS

Optical density measurements automatically corrected to a 1-cm pathlength with PathCheck Technology

Transcription:

ENHANCING SOLID-PHASE DISK EXTRACTION PERFORMANCE WITH DESIGN OF EXPERIMENTS BY CRAIG A. PERMAN Product Development Specialist 3M Company Filtration Products Laboratory Building 60-1W-17 St. Paul, MN 55144 E-mail: caperman@mmm.com

ENHANCING SOLID-PHASE EXTRACTION DISK PERFORMANCE WITH DESIGN OF EXPERIMENTS Solid phase extraction (SPE) disks created using designed experiments take a special form with a process patented in 1989 by the 3M Company of St. Paul, MN. The extraction disks, known by the trademarked name Empore, are prepared by blending polytetrafluoroethylene (PTFE, generic for Teflon TM ) with particle adsorbents to make thin membranes from which the disks are produced. Ranging in size from 6mm to 90mm in diameter, these disks are used to capture everything from pesticides in drinking water to drugs in biological samples. Several months ago, various PTFE membranes were reformulated to make faster-flowing disk products that would be less prone to plugging. SPE disks that plug during extractions can result in incomplete or inconsistent analyte recovery, costing laboratories valuable time -- especially if an entire analysis procedure must be repeated. Although the 3M Company had previously developed a successful Empore extraction disk, the company saw the need for an improvement to increase customer satisfaction. Both new and established customers wanted a durable disk to rapidly extract analytes without the problems often associated with competitive SPE products. The goal in improving Empore technology was to redesign the disk to make a strong, fast-flowing product capable of consistently yielding high recovery rates. Because of the large number of variables encountered in making Empore TM SPE products, an experimentation method was needed to rapidly evaluate the effect of more than one process variable at a time. Design-Expert software from Stat-Ease, Inc. (Minneapolis, MN) was used because of its straightforward capability to design a multivariable experimental protocol. EMPORE TM SPE DISKS Empore TM SPE disks are formulated using PTFE and various solid-phase sorbant particles, such as C18- derivatized silica or resin-based sorbants. The chemistry of PTFE disks is similar to conventional SPE cartridges manufactured by other companies using loose particles, but this is where the similarity ends. The PTFE tightly enmeshes the small sorbant particles, providing high uniformity in the particle bed. This eliminates channeling effects that may occur when loosepacked particles are used in cartridges and plates. With this design, 3M Empore TM disks adsorb analytes more efficiently. Smaller bed volumes are

achieved, meaning less solvent is required for processing -- resulting in more concentrated samples. Advantages of the 3M -membrane technology are: i Reduced solvent and elution volumes i Elimination of a solvent evaporation step i Higher sample throughput i Improved recovery efficiency i Reduced or eliminated channeling effects. 96-WELL PLATES Empore TM extraction disks are an important component of 3M s TM 96-well plates. In this application, disks are punched from a large membrane and placed in an array of 96 wells, forming what is known as a 96-well plate. These plates are used in hospitals, pharmaceutical companies, and bioanalytical labs to analyze blood and urine specimens, conduct drug screens, or perform drug metabolism studies. An individual well in a plate of 96 is one analysis, meaning 96 specific samples can be prepared per plate. (See Figure 1.) 2857(6<0 FIGURE 1 -- An improved 96-well extraction plate patented by 3M provides high analyte recovery while maintaining excellent flow characteristics. A plate of 96 wells measures approximately five inches by three inches, with each well holding up to 2.5 ml of solution. The bottom of each well contains a pre-filter and an Empore extraction disk. Small retaining rings secure each disk in place at the bottom of every well. Customers fill the plates manually with micropipettes or insert them into robotic machines that prepare and extract the plates according to preset software routines. Typically, robotic instruments place a small amount of sample into each of the 96 wells, then apply a vacuum that draws liquid through the disk. As the drug of interest is drawn through each well, it is captured by the Empore membrane. In a

subsequent step, solvent is added to the well to remove or elute the drug analyte from the membrane. The eluted material is placed into a collection plate (also 96 wells) before being injected into HPLC or LC/MS instrumentation for analysis. HOW DESIGN OF EXPERIMENTS (DOE) OPTIMIZED EMPORE DOE is an effective statistical method that applies systematic experimentation to all factors or variables simultaneously. It provides information about how factors interact in a way that one-factor-at-a-time (OFAT) cannot determine. OFAT s major downfall is that it holds all factors constant while testing only one at a time. This technique is an artifact from the days of Edison, who used the method to conduct thousands of single-variable tests while developing the light bulb. 3M s solution for an optimized extraction disk formula required analyzing how process variables or factors were interacting an ideal scenario for DOE. The method s sophisticated statistical technique shows how interconnected factors respond over a wide range -- without the necessity to test all possible values directly. Using Design-Expert, 3M conducted a series of reformulation experiments. In this effort, experimenters studied different Empore disk formulations for membranes of various thickness. The project determined the effects of formulation changes on the membrane by analyzing various responses such as flow rate and other responses. Four formulation factors were studied: 1) Organic solvent amount 2) Particle binding materials 3) Dough solids or water added 4) Number of mill passes of Empore pre-disk dough through a proprietary mill process. A design-building matrix within the Design-Expert software provided assistance in choosing the number of experiments to conduct. (See Figure 2.)

FIGURE 2 -- Design-Expert s Design Builder helped 3M researchers set up a 2 4-1 fractional-factorial design (see arrow). Color-coding similar to a stoplight represents safe (green), cautious (yellow), and risky (red) design options. This 2 4-1 DOE required careful attention (yellow). However, with half as many experiments (8) to be performed as a full factorial (16), monetary and time savings were substantial, justifying the decision. After reviewing several experimental options, a four-factor, fractional-factorial, two-level experiment with one center point was chosen as the best approach. (A center point is an experimental run with all numerical factor levels set at the midpoint of their high and low settings.) A partial factorial design protocol yielded eight formulas plus one centerpoint formula. This was found to be a desirable number of experiments, considering the number of analytical tests that would subsequently have to be conducted on each membrane. Such tests were required in order to evaluate the effect of various formula changes generated by the software. Two-level (high and low) testing used in DOE is highly effective. A powerful statistical engine within Design-Expert software fits response data to mathematical equations. The resulting equations serve as models that predict what will happen for any given combination of values. The DOE software uncovered the Empore formula s most dominant factor interactions and identified the variables that had the greatest effect on disk performance (Figure 3.)

CONCLUSION Designed experiments software is a powerful tool when several variables are to be studied at one time. The results of this study yielded new Empore TM formulas that provide faster flow rates with no membrane plugging problems -- while maintaining high analyte recovery. These benefits were obtained while maximizing physical disk strength and the integrity needed in a finished consumer product. High-performance membranes mean that customers can use Empore TM products with the assurance that they will provide the best possible performance in all applications. With the statistical assistance of Design-Expert software, the improved extraction disk now meets the needs of 3M customers worldwide with its faster-flowing, high analyte recovery capabilities.,qwhudfwlrq*udsk )/2: 7,0( *5$3+2857(6<67$7($6(,1 $ $ FIGURE 3 -- Factor A and C Interaction affects Empore disk product Flow Time. CONTACT INFORMATION: Design-Expert 6.0 Software Stat-Ease, Inc. 2021 East Hennepin Avenue, Suite 191 Minneapolis, MN 55413

Phone 800.801.7191, 612.378.9449, Fax 612.378.2152 E-mail info@statease.com Web site www.statease.com CRAIG A. PERMAN Product Development Specialist 3M Company Filtration Products Laboratory Building 60-1W-17 St. Paul, MN 55144 E-mail: caperman@mmm.com Web site: www.mmm.com/market/industrial/empore