ED 701 General Industry Pressure Transmitter

Similar documents
Pressure Transmitter ED 701

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure transmitters for industrial applications MBS 32 and MBS 33

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Field IT 50T Series Transmitters

Industrial Pressure Transmitter

PRODUCT CATALOGUE PREssURE switch

Industrial Pressure Transmitter

Pressure Measurement Single-range transmitters for general applications

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

Relative pressure transmitter type 520

ATEX/IECEx RTD temperature probe

Operating Instructions for Digital Manometer. Model: MAN-SD

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

Installation guide 862 MIT / MIR

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

Direct-operated 2/2-way compact solenoid valves Type EV210A

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Pressure. 1 Fitting PA R - N R2

E8EB-N0C2B E8EB-N0B2B

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

Solenoid valves 2/2-way direct-operated type EV210A

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Type UB1 Load Cell. Option Stainless steel cable gland

Conductivity sensor for hygienic applications

SANMUR CONTROLS PVT. LTD.

Z7A. Load cells. Special features. Data sheet. Wiring code

Fitting PS P - B - R2

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

all stainless steel transducer multimedia compatibility

Direct-operated 2/2-way solenoid valves Type EV210B

FLOW SENSOR FOR LIQUID MEDIA Serie 210

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Silicon Temperature Sensors KT 100 KT 110 KT 130 KT 210 KT 230. KTY 11-x KTY 13-x KTY 21-x KTY 23-x KTY 19-6 KTY 16-6

RoHS. Versatile. X g. X 2 e

Ex floating switches and Ex immersion probes

Single point load cells

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Flow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.

Reflex-Radar BM 100 A

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

PHOENIX CONTACT - 04/2016. Features

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

1 Overview. Pressure Measurement Transmitters for applications with basic requirements (Basic) SITRANS P310 - Technical description

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

ISEmax CAM40/CAS40. Technical Information

OEM Flow sensor for liquid media type 200

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

SlimLine Sensors (SLS)

Size A DIN EN

Operating instructions Pressure sensor PN / / 2007

TABLE OF CONTENT. ATEX Certificate. Designation code. Circuit diagrams. Sensors. Sensors. Explosion-proof sensors from Pulsotronic

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

PN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings

Field mounted Temperature Transmitter TF212/TF212-Ex

Exchangeable measuring insets SensyTemp TSA101

Surface-mounting thermostats Series ATH

SmartLine Radar Level Meter RM70

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

Differential indicators

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Pressure Display Controller

FKC... 5 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER FEATURES SPECIFICATIONS. Functional specifications

Connector~Tech Providing Harsh Environment Connector

DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

Imformation of C091D series

OEM Flow sensor for liquid media type 200

Surface-mounting Thermostats ATH Type Series

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

Linear measuring technology

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2..

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters

OEM Flow sensor type 235 for liquid media

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Model DS1200-AMT-Ex Intrinsically Safe 4-20mA ATEX Certified Dewpoint Hygrometer Ranges available between -120 C to +20 C (-166 F to +68 F) dewpoint

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Thermal-Magnetic Circuit Breaker 2210-S2..

Transcription:

ED 701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response time < 25 ms (option 5 ms) High long-term stability Excellent repeatability Active compensation for temperature drifts ATEX II 1G, II 2G, II 1/2G and II 1D The large choice of pressure and electrical connections makes the ED 701 series suitable for a large variety of applications. The ED 701 pressure transmitters are available in 4 20mA current loop or in voltage output signal versions. These transmitters offer a very high accuracy over a wide temperature range, an excellent repeatability and long time stability as well as a short response time (down to 5 ms). The piezo-resistive silicon sensor is anodic bonded on a very stable glass base, which is attached to a stainless steel construction. This assembly guarantees an excellent thermal isolation. The sensor is isolated from the process by a stainless steel diaphragm (1.4404 / 316L) and a filling liquid. The electronic is located within the hermetically sealed transmitter housing which gives the ED 701 an excellent resistance to humidity, shock and vibration. Protection class, from IP 65 to IP 67 only depends on the choice of the electrical connection. The electronic is a state-of-the-art signal processing unit fitted with a fast micro-controller allowing the compensation of drift effects due to temperature on the sensor signal, over a wide temperature range with a fast response time. The ED 701 is available with a great variety of pressure and electrical connections to meet all requirements. The electrical connection can be replaced easily and gives access to the Autozero adjustment. The ED 701 is a very flexible transmitter suitable for all types of industrial applications. According to its ATEX approval the ED 701 can be used in potentially explosive atmospheres (gases, vapors and dust). Design and specifications subject to change without notice Page 1

Ordering details digit: Positions 1 2 3 4 5 6 7 8 9 10 11 12 Pressure connection Male thread G 1 2 EN 837-1 1 Male thread G 1 4 EN 837-1 2 Male thread M20x1.5 DIN 16288 3 Male thread G 1 2 DIN 3852 with O ring 4 Male thread G 1 8 EN 837-1 5 Female thread G 1 2 DIN 3852 6 Female thread G 1 4 DIN 3852 7 Male thread 1 2-14NPT, ASP N152 A Female thread 1 4-18NPT, ASP N152 B Male thread 7 16-20UNF E Output signal 4... 20 ma 2 0... 10 V DC 4 0... 5 V DC 5 Approval CE conform 0 ATEX 1 Electrical connection 2 meter shielded cable 3 conductors, IP 65 1 2 meter shielded cable 3 conductors, IP 67 9 Fischer Plug, IP 67 2 DIN 41524 Binder Plug, IP 65 3 DIN 43650 Plug, IP 65 4 Bendix 6 pole Plug, IP 65 5 M12, 4 pole Industrial Plug, IP 67 6 1 2 NPT, cable length 1 m, IP 67 7 Field Housing, cable gland brass nickel-plated, IP 67 1 ) A Field Housing, cable gland stainless steel, IP 67 1 ) B Field Housing cable gland PA, IP 67 1 ) C Field Housing M12 Plug, stainless steel, IP 67 D Accuracy Medium temperature up to 125 C 0.4% FS, compensated temperature range 10 +125 C 1 0.2% FS, compensated temperature range 10 +125 C 2 0.1% FS, compensated temperature range 10 +80 C 3 5 ms response time 0.4% FS, 5 ms, compensated temperature range 10 +80 C 6 0.2% FS, 5 ms, compensated temperature range 0 +60 C 7 High medium temperature Only possible with the cooling adapters (see Accessories) Pressure unit Gauge pressure (100 mbar up to 40 bar) 3 Absolute pressure (500 mbar up to 40 bar) 4 Negative gauge pressure (0 100 mbar, 1 24 bar) 5 Pressure range 100 mbar up to 40 bar: gauge pressure 500 mbar up to 40 bar: absolute pressure See table Pressure range 1) Field Housing: The cable gland are compatible with cable diameter of 5 mm to 12 mm. Design and specifications subject to change without notice Page 2

Ordering details (continued) digit: Positions 1 2 3 4 5 6 7 8 9 10 11 12 Wetted parts All stainless steel 1 Oil filling FDA approved white oil (Standard) 2 ) 1 Silicon oil) 3 ) 0 2) ED 701 with FDA approved white oil: the medium temperature is limited to 10 + 125 C. 3) ED 701 with silicon oil: the medium temperature is limited to 30 + 125 C. Standard ED 701 Delivery Calibration temperature: The ED 701 are calibrated at + 25 C. If another calibration temperature is needed, the option /9007/TTTT has to be mentioned, as part of the ordering code (see Options). Electrical connections: No cable socket will be provided. Such accessories have to be ordered separately (see Accessories). Test Certificate: Each ED 701 will be delivered with a Test Certificate at the calibration temperature (6 points). If not specified, the Certificate will be in German (see Options). O-Ring seals: The pressure connection 4 ( Position 1) is always delivered with a NBR O-Ring. Other O-Rings are available (see Accessories). The other pressure connections are delivered without any O-rings. Options Specific pressure range: /SETR An application specific pressure range can be defined here. The range must be given in plain text. Example: /SETR 500 mbar 2500 mbar Specific calibration temperature (temperature of the medium): /9007/TTTT Example: /9007/0100. The ED 701 will be calibrated for a medium temperature of 100 C (ex factory). This option is reducing the compensated temperature range at ± 25 C of the calibration temperature. Language of the Test Certificate and Operating Manual: Both documents are available in German, French and English. The desired language must be specified in plain text with the ordering code. Standard will be German. Pressure range Code Range Code Range Code Range Code Range mbar mbar bar bar 126 0...100 B06 0...150 136 0...160 A56 0...200 146 0...250 B26 0...300 B36 0...350 156 0...400 A66 0...500 166 0...600 B46 0...700 176 0...1000 P46 0...1250 B56 0...1400 186 0...1600 D06 0 100 20 ) D16 0 160 20 ) D26 0 200 20 ) D46 0 400 20 ) D56 0 500 20 ) D66 0 600 20 ) A76 0...2000 196 0...2500 206 0...4000 A86 0...5000 216 0...6000 P76 0...7300 226 0...10000 P86 0...18300 H66 100 100 20 ) H76 200 200 20 ) H86 500 500 20 ) C46 200 0 20 ) C56 500 0 20 ) 20) Negative gauge pressure ranges: only available with the pressure unit code 5 ( Position 6). L25 1...10 015 0...0.6 025 0...1 035 0...1.6 A15 0...2 045 0...2.5 L35 0...2.8 055 0...4 A25 0...5 065 0...6 L45 0...7 L05 0...8 075 0 10 L15 0 12 085 0 16 A35 0 20 095 0 25 L55 0...30 105 0...40 D85 0 1 20 ) E05 0.1 1 20 ) E15 0.1 2 20 ) 315 1 0 20 ) H05 1 1 20 ) 525 1 3 20 ) 535 1 5 20 ) 545 1 9 20 ) E65 1 1.6 20 ) F05 1 2 20 ) F15 1 10 20 ) F45 1 12.5 20 ) F25 1 20 20 ) F35 1 24 20 ) Design and specifications subject to change without notice Page 3

Code Range Code Range Code Range psi psi in H 2 O 05D 0...1.5 06D 0...2.5 07D 0...3 08D 0...4 09D 0...6 45D 0...7.5 10D 0...10 11D 0...15 12D 0 30 13D 0 60 51D 0 75 14D 0...100 15D 0...150 16D 0 200 17D 0 300 18D 0 400 32D 0 500 70D 1.5 1.5 20 ) 71D 3 3 20 ) 72D 6 6 20 ) 80D 15 15 20 ) 60D 1.5 0 20 ) 61D 3 0 20 ) 62D 6 0 20 ) 81D 15 30 20 ) 82D 15 60 20 ) 83D 15 150 20 ) 17G 0...40 18G 0...50 19G 0...60 22G 0...100 30G 0...300 40G 0...750 Code Range Code Range Code Range Code Range mm H 2 O m H 2 O m H 2 O m H 2 O 177 0...1000 P47 0...1250 187 0...1600 A77 0...2000 197 0...2500 207 0...4000 A87 0...5000 217 0...6000 P77 0...7300 227 0...10000 P87 0...18300 028 0...1 038 0...1.6 A18 0...2 048 0...2.5 L38 0...2.8 058 0...4 A28 0...5 068 0...6 L48 0...7 L08 0...8 078 0...10 L28 1...10 L18 0...12 088 0...16 A38 0...20 098 0...25 L58 0...30 L78 0...32 108 0...40 A48 0...50 118 0...60 L88 0...64 L68 0...70 128 0...100 L98 0...128 B08 0...150 138 0...160 A58 0...200 148 0...250 B28 0...300 B38 0...350 158 0...400 H08-1...1 20 ) H18-2...2 20 ) H28-5...5 20 ) H38-10...10 20 ) C08-2...0 20 ) C18-5...0 20 ) D88 0...-1 20 ) E08-0.1...1 20 ) E18-0.1...2 20 ) E68-1...1.6 20 ) F08-1...2 20 ) F18-1...10 20 ) F28-1...20 20 ) F38-1...24 20 ) F48-1...12.5 20 ) Code Range Code Range Code Range Code Range MPa KPa KPa KPa 013 0...0.6 023 0...1 033 0...1.6 A13 0...2 043 0...2.5 053 0...4 883-0.1...0.9 20 ) E03-0.1...1 20 ) E13-0.1...2 20 ) 072 0...10 L22 1...10 L12 0...12 082 0...16 A32 0...20 092 0...25 L52 0...30 L72 0...32 102 0...40 A42 0...50 112 0...60 L82 0...64 L62 0...70 122 0...100 132 0...160 A52 0...200 142 0...250 B22 0...300 B32 0...350 152 0...400 A62 0...500 162 0...600 B42 0...700 172 0...1000 P42 0...1250 B52 0...1400 182 0...1600 A72 0...2000 192 0...2500 202 0...4000 H32-10...10 20 ) H42-20...20 20 ) H52-50...50 20 ) H62-100...100 20 ) 352-10...0 20 ) 362-16...0 20 ) C22-20...0 20 ) 372-25...0 20 ) 382-44...0 20 ) C32-50...0 20 ) 392-60...0 20 ) 402-100...0 20 ) C92 0...-60 20 ) D02 0...-100 20 ) 642-10...15 20 ) 652-15...10 20 ) 662-15...25 20 ) 672-25...15 20 ) 682-20...40 20 ) 692-40...20 20 ) 702-40...60 20 ) 712-60...40 20 ) 722-60...100 20 ) 732-100...60 20 ) 742-100...150 20 ) G02-100...200 20 ) 922-100...300 20 ) 932-100...500 20 ) 20) Negative gauge pressure ranges: only available with the pressure unit code 5 ( Position 6).. Design and specifications subject to change without notice Page 4

Technical data Measurement characteristics Pressure range Gauge pressure: from 0 100 mbar up to 0 40 bar. Absolute pressure: from 0 500 mbar up to 0 40 bar. The standard pressure ranges are listed in the pressure range table. Other specific ranges are available with the option SETR. Over pressure limits Pressure range 0 P (bar) 0.1 0.35 0.4 1.0 1.6 5 6 20 25 35 40 Maximum pressure P max [bar] 1 3 15 60 105 120 Accuracy 0.1%, 0.2% und 0.4% classes (see ordering code Position 5). Hysteresis and repeatability Long term stability ± 0.05% FS ± 0.2% FS / year Response time (10 90%) 25 ms 5 ms with the accuracy codes 6 und 7 ( Position 5). Temperature influence (in compensated range) Depending on the accuracy class:, Position 5 = 1 and 6 (class 0.4%) Zero: TC ± 0.20% FS / 10K. Span: TC ± 0.15% FS / 10K., Position 5 = 2 and 7 (class 0.2%) Zero: TC ± 0.15% FS / 10K. Span: TC ± 0.10% FS / 10K., Position 5 = 3 (class 0.1%) Zero: TC ± 0.05% FS / 10K. Span: TC ± 0.05% FS / 10K. Operating temperature of the oil filling, Position 11 ED 701 with FDA approved white oil (Standard): 10 C +125 C ED 701 with silicon oil: 30 C +125 C Ambient temperature (housing) -10 C +80 C Storage temperature -10 C +80 C Materials specification Wetted part Stainless Steel W.1.4435 (fitting body) and W.1.4404 (AISI 316L, diaphragm) Parts not in contact with medium Stainless Steel W.1.4301, W.1.4305 and elec tri cal con nec tor material. Certificate EN10204 3.1B available on request Electrical specification Supply voltage 10... 30 V DC (4 20 ma) 10... 28 V DC (4 20 ma EEX) 15... 30 V DC (0 10 V DC) Insolation Resistance >1 GOhm, 500 V DC Load (current output) R L < 50 x U B - 450 Load (voltage output) R L 5 kohm Protected against reverse signal po lar i ty. Switch ON time 5 sec. EMC Influence of EMC Less than 0.15% FS Conformity EN 50081-1, EN 50082-2, EN 61326, EN 50121-4 ATEX data Intrinsically safe conforming to EN 50020 and EN 50281-1-1 Applications: II 1G II 1D Device located in zone 0/zone 20 II 1/2G II 1D Pressure connection in zone 0/zone 20 Housing and electrical connection in zone 1/zone 20 II 2G II 1D Device located in zone 1/zone 20 Intrinsically safety EEx ia IIC. The device can only be connected to an approved intrinsically safe current loop with the following boundery values: U 0 = 28 V I k = 100 ma P = 1.5 W The device internal capacity and inductivity values are: C i = 1 nf L i = 0.1 mh Environmental specification Humidity According to EN 60068-2-38 Vibrations According to EN 60068-2-6 Shocks According to EN 60068-2-31 Protection class Rating IP 65 and IP 67, depending on electrical plug. Mounting Position at calibration time: Vertical Physical characteristics Weight Between 223 and 885 g depending of the version. Dimensions See drawings. Design and specifications subject to change without notice Page 5

Technical data Zero adjustment and factory setting: The zero adjustment and factory setting are directly available on the ED 701 by removing the electrical plug. A push button on the top of the electronic unit can be activated. Zero adjustment: By pressing the push button the applied pressure will be considered as the new zero point and the output signal will be reset (i.e. 4 ma or 0 VDC). This function allows some corrections when the mounting position influences the measurement, when temperature or long term drifts occurs and when a resetting in a level measurement application is needed. Factory setting (zero): The factory setting can be reloaded at any time. To do it the push button must be pressed during at least 10 seconds. Oil filling Standard: The standard oil filling is the FDA approved white oil (Paraffin oil). This is the best choice for all the applications in the food, beverages, pharmaceutical and biotech industries. ED 701 with this oil filling should not be used below 10 C and above +125 C, it could severly damage the ED 701. Alternative: The silicon oil can be recommended for all general industrial applications. ED 701 with silicone oil can be used in a temperature range from -30 C up to +125 C. Pressure connection availability Overview table Code Pressure connection Material Oil filling Accuracy 1.4435 FDA Silicon P < 1 bar P 1 bar 0.1% FS 0.2% FS 0.4% FS 1 Male thread G 1 2 EN 837-1 2 Male thread G 1 4 EN 837-1 3 Male thread M20x1.5 DIN 16288 4 Male thread G 1 2 DIN 3852 with O ring 5 Male thread G 1 8 EN 837-1 6 Female thread G 1 2 DIN 3852 7 Female thread G 1 4 DIN 3852 A Male thread 1 2-14NPT, ASP N152 B Male thread 1 4-14NPT, ASP N152 E Male thread 7 16-20UNF Available Design and specifications subject to change without notice Page 6

Drawing (all dimensions in mm) DIN 43650 plug Code: 4 Bendix 6 pole plug Code: 5 Cable 3 conductors IP 65 / IP 67 Code: 1 (IP 65) 9 (IP 67) DIN 41524 Binder plug Code: 3 17 17 10.4 14 Fischer plug Code: 2 NPT 3 conductors Code: 7 M12 industrial plug Code: 6 Field housing Code: A, B, C and D 55 14.5 SW 27 10 10.4 55 61.5 Code Thread d 1 l 1 A 1 2-14NPT 20 Code Thread d 1 d 2 d 3 l 1 l 2 E 7 16-20UNF 9.2 4.5 9 4.5 key 27 key 27 key 27 d 3 l 3 l 2 l 1 23 d 1 13.6 23 l 1 d 1 25 l 1 key 27 45 d 3 d 2 l 2 l 1 23 key 27 d 1 d 2 l 1 l 2 23 d 2 d 1 d 1 Code Thread d 1 d 2 d 3 l 1 l 2 l 3 1 G 1 2 17.5 6 20 3 3 2 G 1 4 9.5 5 13 2 2 3 M20x1.5 17.5 6 20 5 2 5 G 1 8 8 5 10 2 2 Code Thread d 1 l 1 4 G 1 2 14 Code Thread d 1 d 2 l 1 l 2 6 G 1 2 28 15 17.5 7 G 1 4 26 12 14 B 1 4-18NPT 26 10.2 12.5 Design and specifications subject to change without notice Page 7

Mounting example Pressure port: Code A Pressure port: Code E Screw hole Screw hole Pressure port: Code 1, 2, 3, 5 Seal Pressure port: Code 6, 7, B Seal Screw hole Pressure port: Code 4 Screw hole Seal Screw hole Connecting diagram Electrical connection For Voltage signal Output 0 max. 10 V a For 4... 20 ma current loop version b I A UA RL U B a U B c b I A R L d d Pin assignment Contact DIN 43650 plug Bendix 6 poles plug Cable 3 conductors DIN 41524 Binder plug 4...20 ma 0...5/10 V DC 4...20 ma 0...5/10 V DC 4...20 ma 0...5/10 V DC 4...20 ma 0...5/10 V DC a 1 1 B B Blue Blue 3 3 b 2 2 E E Brown Brown 1 1 c - 3 - D - Black - 4 d GND GND Case Case brown black Case Case View blue soldering side, cable socket Pin assignment Contact Fischer plug NPT 3 conductors M12 industrial plug Field housing 4...20 ma 0...5/10 V DC 4...20 ma 0...5/10 V DC 4...20 ma 0...5/10 V DC 4...20 ma 0...5/10 V DC a 1 1 Red Red 3 3 1 1 b 2 2 Black Black 1 1 2 2 c - 3 - Green - 4-3 d Case Case Case Case 4 4 View soldering side, cable socket red black green Design and specifications subject to change without notice Page 8

Accessories Adapter for high temperature (cooling device) EN 837-1 DIN 3852 d G 1 2 G 1 2 l T Code 2 ) T med max. l T d Connection Material 1 300 C 123 40 G 1 2 Stainless steel 1.4435 D 12361.0 1 200 C 95 27 G 1 2 Stainless steel 1.4435 D 12361.1 1 150 C 68 27 G 1 2 Stainless steel 1.4435 D 12361.21 EN 837-1 EN 837-1 d G 1 2 G 1 2 l T Code 2 ) T med max. l T d Connection Material 1 300 C 131 40 G 1 2 Stainless steel 1.4435 D 12361.2 1 200 C 103 27 G 1 2 Stainless steel 1.4435 D 12361.3 1 150 C 79 27 G 1 2 Stainless steel 1.4435 D 12361.22 EN 837-1 d G 1 2 1 2 14-NPT l T Code 2 ) T med max. l T d Connection Material 1 300 C 125 40 1 2 14-NPT Stainless steel 1.4435 D 12361.6 1 200 C 97 27 1 2 14-NPT Stainless steel 1.4435 D 12361.7 1 150 C 70 27 1 2 14-NPT Stainless steel 1.4435 D 12361.23 2) Cross reference to ordering code digit 1, process connection, see page 2 Electircal sockets Cable socket connector DIN 43650 E 6844.0 Cable socket connector M12 E 15560.0 SW 52.5 M12x1 Cable socket connector Binder E 13265.0 Cable socket connector M12 E 15560.1 35 Cable socket connector Bendix E 6586.1 20 Cable socket connector Fischer E 13267.0 35 9 Design and specifications subject to change without notice Page 9

Accessories Cable Extension cable M12 E 15543.x LLL Type Shielded PVC Kabel 0 Shielded PUR Kabel 1 Length 2 meters 002 5 meters 005 10 meters 010 20 meters 020 O-Rings The O-rings for the pressure connection 4 (ordering code Position 1) are available in NBR, EPDM and Viton (FPM). The following operating temperature of the O-rings are only indicative values (dry air): NBR (FDA): 25 + 125 C EPDM (FDA): 40 + 160 C FPM / Viton (FDA): 20 + 200 C Pressure connection Designation Material 4 O-Ring for male thread G 1 2 (at the rear) NBR (FDA) A8550.9110 4 O-Ring for male thread G 1 2 (at the rear) FPM / Viton (FDA) A8550.9111 4 O-Ring for male thread G 1 2 (at the rear) EPDM (FDA) A8550.9112 Viton is a registered trademark of DuPont Performance Elastomers E/2005-08-11 This data sheet may only be reproduced in full. Design and specifications subject to change without notice Page 10