Cat Electronic Technician 2014A v1.0 Product Status Report 10/23/2016 9:09 AM

Similar documents
PowerView Modbus Registers (Ver 3.2)

FMS-prep message overview

Technical Publication Index CAGE 07147

Technical Publication Index CAGE 07147

Generators. What its all about

POWER QUALITY MEASUREMENT PROCEDURE. Version 4 October Power-Quality-Oct-2009-Version-4.doc Page 1 / 12

HERU Modbus. Reference Modbus addresses for HERU (Gen 3)

Motors Automation Energy Transmission & Distribution Coatings. Servo Drive SCA06 V1.5X. Addendum to the Programming Manual SCA06 V1.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Woodward proact plus manual. Woodward proact plus manual.zip

Clean Air Zone (CAZ) - CLEAN VEHICLE RETROFIT CERTIFICATION INFORMATION DOCUMENT FOR CVRC LOW EMISSION ADAPTATIONS

Differences between PCL-240MK and PCL-240MS

A 954 C HD. Technical Description Hydraulic Excavator. Machine for Industrial Applications

Ultrasonic Gas Flow Meter

Product Manual (Revision D) Original Instructions. Speed Switch and Integrated Speed Switch. Installation and Operation Manual

Swegon CASA Smart ModBus Register SCB 3.0

FY04 Luminosity Plan. SAG Meeting September 22, 2003 Dave McGinnis

ALASTAIR MCLACHLAN Applications Cameron

Acceleration/Velocity/Displacement VIBRATION METER

Modelling of Primary Frequency Control and Effect Analyses of Governing System Parameters on the Grid Frequency. Zhixin Sun

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Dynamic simulation of a five-bus system

The Challenge is to Define: System Engineering. System Engineering Components. Functional Requirements

GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

KOBELCO NEW FEATURES SK115SR

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

CHV Series Vector Control Inverter Options. Operating Instructions for Tension Control Card

SUBJECT TO CHANGE WITHOUT NOTICE

A compilation of key maintenance and performance articles taken from the former Lycoming Flyer Newsletter. Lycoming Flyer Key Reprints

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Thermal overload. Operation

FIII LonWorks Bridge Network Variables v2.32

Exp All technology at operator s service. Suggested Orange peel. Straight boom m. Industrial straight stick 8.00 m RV 600 2,

DF60/DF70 SERVICE DATA. Data DF70T/70WT/70WTH POWERHEAD

Consultants: firms Consultants: individuals

Standard Practices for Air Speed Calibration Testing

DF40/DF50 SERVICE DATA. Data DF40T/40QH POWERHEAD. Except E01. Recommended operating range

WIND DATA REPORT. Vinalhaven

Mini-project report. Modelling and control of a variablespeed subsea tidal turbine equipped with permanent magnet synchronous generator.

WIND DATA REPORT. Vinalhaven

This Capstone Project will address the analysis and diagnosis of the Steam Turbo-Generator (STG) machine vibration problems in Thermal Power Plant

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Sarah Alison-Youel Research & Development Ebara International - Cryodynamics Sparks, NV USA. AIChE Spring Meeting Tampa, FL April 2009

Three phase induction motor using direct torque control by Matlab Simulink

Gas Turbine Seminar -17 Lund University

Sprint Gas. Vialle Liquid & Vapour Spares Catalogue

24 volts (0.25 amps current-limited)

CANDU Safety #3 - Nuclear Safety Characteristics Dr. V.G. Snell Director Safety & Licensing

Optimal Discrete Event Supervisory Control of Aircraft Gas Turbine Engines

Chapter 7 & 8 Control Rods Fission Product Poisons. Ryan Schow

WE RE HERE TO HELP: 1 (844) LIGHTCLOUD

`Transient conjugate heat transfer analysis of a turbocharger

Effect of the Exit Pressure Pulsation on the Performance and Stability Limit of a Turbocharger Centrifugal Compressor

Combination Meter <LHD> Power Management Control ECU ( 4) 32 A. Junction Connector ( 8) Radio Receiver Assembly. Stereo Component Amplifier Assembly

Microprocessor Based Characteristics and adjustments

PAX2S Modbus Register Table REVISED 2/20/12 LP0894A

1. Wind turbines are designed to operate within specified design criteria. Often the operating environment extends beyond these limits and causes

Transient Stability Assessment of Synchronous Generator in Power System with High-Penetration Photovoltaics (Part 2)

CapaciTorr HV 200 HIGHLIGHTS

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

ISEmax CAM40/CAS40. Technical Information

LHC ORBIT SYSTEM, PERFORMANCE AND STABILITY

King Fahd University of Petroleum and Minerals College of Computer Science and Engineering Computer Engineering Department

Lecture - 2A Instruments-I

Kjeltec 2300 Analyzer Unit

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design

Run II Status and Prospects

Review of Anemometer Calibration Standards

Mitigation of Diesel Generator Vibrations in Nuclear Applications Antti Kangasperko. FSD3020xxx-x_01-00

Solving a Sever PLACE Vibration FOR TITLE Problem in the. Downstream Piping of a Gear Pump

43iQ MODBUS Register Table

Tevatron Detector Upgrades

Certificate: / 9 September 2014

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

BELT TENSIONS & HP RESULTS

WORK SHEET FOR MEP311

Separations and Reactors Design Project. Production of Allyl Chloride

SOME ASPECTS OF COOLANT CHEMISTRY SAFETY REGULATIONS AT RUSSIA S NPP WITH FAST REACTORS

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Near-Field Sturgeon Monitoring for the New NY Bridge at Tappan Zee. Quarterly Report October 1 December 31, 2014

INTERACTING AND NON-INTERACTING SYSTEM

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

DARS Digital Analysis of Reactive Systems

System Components. Electric Motors.

Non-linear Identification and Analysis of a HEUI System

The FLIP Experiment: Testing the Relationship of Length of Upwelling Tubes to Maximize Upwelling Velocity

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES

MAGPOWR TENSION CONTROL DLCA NET-SLIM. User Manual. Digital Load Cell Amplifier MI 850A358 1 A

KN Series Boiler HeatNet V3 LonWorks Network Variables V1.10

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

WIND DATA REPORT. WBZ Tower, Hull, MA

ATT 310 USER MANUAL

Thermographic Phosphors Temperature measurements using Laser Induced Phosphorescence (LIP)

Exercise 8 - Turbocompressors

PUMP PERFORMANCE MEASUREMENTS Jacques Chaurette p. eng. April 2003

Low slice emittance preservation during bunch compression

EddyMax Tube Inspection

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

Transcription:

Cat Electronic Technician 2014A v1.0 Product Status Report 10/23/2016 9:09 AM Product Status Report Parameter Engine Serial Number Equipment ID Comments Value DSE00164 78M-9-P RUNNING OF NOS.3 ENGINE AFTER OVERHAUL ON 23/10/2016 @0905 HRS ON OCEAN GLORY C18 Marine Genset #1 (DSE00164) Parameter Value Equipment ID 78M-9-P Engine Serial Number DSE00164 ECM Serial Number 04946101JV Software Group Part Number 4472902-00 Software Group Release Date OCT13 Software Group Description C18-MarAuxACERT-A4 Logged Diagnostic Codes [Diagnostic Clock = 4712.1829 hours] - C18 Marine Genset #1 (DSE00164) Code Description Occ. First Last 91-8 Throttle Position Sensor : Abnormal Frequency, 2 4700 4711 Pulse Width, or Period Logged Event Codes [Diagnostic Clock = 4712.1829 hours] - C18 Marine Genset #1 (DSE00164) Code Description Occ. First Last E096 (1) High Fuel Pressure 1 4712 4712 E105 (2) Turbocharger Turbine Inlet Air High 127 1465 4712 E190 (1) Engine Overspeed Warning 1 4712 4712 E190 (3) Engine Overspeed Warning 1 4712 4712 E198 (1) Low Fuel Pressure 1 4712 4712 E552 (1) Low Aftercooler Coolant Level 32 4654 4711 Active Diagnostic Codes - C18 Marine Genset #1 (DSE00164) Code No Active Codes Description Active Event Codes - C18 Marine Genset #1 (DSE00164) Code Description

No Active Events Current Totals - C18 Marine Genset #1 (DSE00164) Description Value Unit Total Time 4712 hours Total Fuel 57659 gal Average Fuel Rate Based Percent Engine Load Factor 25 % Configuration - C18 Marine Genset #1 (DSE00164) Description Value Unit Equipment ID 78M-9-P Engine Serial Number DSE00164 ECM Serial Number 04946101JV Software Group Part Number 4472902-00 Software Group Release Date OCT13 Software Group Description C18-MarAuxACERT-A4 Rating Number 1 Rated Frequency 60 Hz Rated Engine Speed 1800 rpm Rated Power 738 hp at 1800 rpm Rating Configuration Low Emissions Test Spec 0K0000 Engine Location Engine #1 Engine Acceleration Rate 500 rpm/s Crank Terminate RPM 400 rpm Low Idle Speed 1200 rpm Engine Speed Droop 0.0 % Droop/Isochronous Switch Enable Enabled Droop Mode Selection Externally Requested Isochronous Remote Throttle Control Ramp Rate 10 rpm/s Desired Speed Input Configuration PWM Secondary Desired Speed Input PWM Configuration Emergency Shutdown Override Input Switch to Ground Configuration Emergency Shutdown Override Switch Not Installed Remote Throttle Control Install Installed Coolant Level Sensor Installed Aftercooler Coolant Level Sensor Installed Unfiltered Engine Oil Pressure Sensor Not Installed Unfiltered Fuel Pressure Sensor Installation Not Installed Status Engine Coolant Pressure Sensor Not Installed

Exhaust Sensor Installation Not Installed Status Engine Oil Sensor Installation Not Installed Status Engine Oil Level Sensor Not Installed High Exhaust Warning Disabled System Enable Status Engine Oil Capacity 19.0 gal Maintenance Indicator Mode Off PM1 Interval 0 gal Governor Gain Factor #1 11534 Governor Minimum Stability Factor #1 1049 Governor Maximum Stability Factor #1 2097 FLS 24 FTS 0 Total Tattletale 14 Lifetime: Time vs Engine Coolant - C18 Marine Genset #1 (DSE00164) Engine Coolant ( hours % Deg F ) <122 4.10 0.09 122-130 3.80 0.08 131-139 4.55 0.10 140-148 5.35 0.11 149-157 51.35 1.09 158-166 1728.35 36.74 167-175 1876.65 39.90 176-184 871.80 18.53 185-193 121.75 2.59 194-202 31.55 0.67 203-211 4.20 0.09 212-220 0.35 0.01 221-229 0.00 0.00 230-238 0.00 0.00 239-247 0.00 0.00 >248 0.00 0.00 Lifetime: Time vs Inlet Air - C18 Marine Genset #1 (DSE00164) Inlet Air ( Deg F ) hours % <104 0.00 0.00 104-112 0.00 0.00 113-121 0.00 0.00 122-130 0.15 27.27 131-139 0.15 27.27 140-148 0.25 45.45 149-157 0.00 0.00 158-166 0.00 0.00 167-175 0.00 0.00 176-184 0.00 0.00

185-193 0.00 0.00 194-202 0.00 0.00 203-211 0.00 0.00 >212 0.00 0.00 Lifetime: Time vs Boost Pressure - C18 Marine Genset #1 (DSE00164) Boost Pressure( psi ) hours % <12 0.00 0.00 12-12 0.00 0.00 13-14 0.00 0.00 15-15 0.00 0.00 16-16 0.00 0.00 17-18 0.00 0.00 19-19 0.00 0.00 20-21 0.00 0.00 22-22 0.00 0.00 23-24 0.00 0.00 25-25 0.00 0.00 26-27 0.00 0.00 28-28 0.00 0.00 >29 0.65 100.00 Lifetime: Time vs Engine Speed And Engine Load Factor - C18 Marine Genset #1 (DSE00164) rpm <1100 1100-1300- 1500-1700- 1900-2100- >2300 Total 1299 1499 1699 1899 2099 2299 % <50 0.00 0.00 0.00 0.00 99.61 0.00 0.00 0.00 99.61 50-60 0.00 0.00 0.00 0.00 0.03 0.00 0.00 0.00 0.03 60-70 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.05 70-80 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.05 80-90 0.00 0.00 0.00 0.00 0.23 0.00 0.00 0.00 0.23 >90 0.00 0.00 0.00 0.00 0.03 0.00 0.00 0.00 0.03 Total 0.00 0.00 0.00 0.00 99.99 0.00 0.00 0.00 100.00 Lifetime: Total Occurrences vs Engine Speed - C18 Marine Genset #1 (DSE00164) Engine Speed( rpm ) % <2500 40.00 85.11 2500-2599 3.00 6.38 2600-2699 2.00 4.26 2700-2799 2.00 4.26 2800-2899 0.00 0.00 2900-2999 0.00 0.00 3000-3099 0.00 0.00 3100-3199 0.00 0.00 3200-3299 0.00 0.00 >3300 0.00 0.00 Lifetime: Time vs Turbo Inlet And Inlet Air - C18 Marine Genset #1

(DSE00164) Deg F <104 104-112 113-121 122-130 131-139 >140 Total Deg F <140 0.00 0.00 88.36 11.64 0.00 0.00 100.00 140-149 0.00 0.00 0.00 0.00 0.00 0.00 0.00 149-158 0.00 0.00 0.00 0.00 0.00 0.00 0.00 158-167 0.00 0.00 0.00 0.00 0.00 0.00 0.00 167-176 0.00 0.00 0.00 0.00 0.00 0.00 0.00 >176 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Total 0.00 0.00 88.36 11.64 0.00 0.00 100.00 Lifetime: Time vs Fuel Pressure - C18 Marine Genset #1 (DSE00164) Fuel Pressure( psi ) hours % <73 25.55 0.54 73-74 551.70 11.73 75-77 0.80 0.02 78-80 0.90 0.02 81-83 1.05 0.02 84-86 1.60 0.03 87-89 2.05 0.04 90-92 1.85 0.04 93-95 9.35 0.20 96-98 12.80 0.27 99-101 22.05 0.47 102-103 9.95 0.21 104-106 3.85 0.08 >107 4060.55 86.32 Injector Trim Calibration - C18 Marine Genset #1 (DSE00164) Injector Serial Number File Version Injector1 000000005A530234388F 0 Injector2 000000005A53023461F1 0 Injector3 000000005A53023421A5 0 Injector4 000000005A53009349AD 0 Injector5 000000005A53013906AD 0 Injector6 000000005A53009301C1 0 Monitoring System - C18 Marine Genset #1 (DSE00164) Description State Trip Point Delay Time Engine Overspeed Least Severe (1) Always On 1980 rpm 0 sec Most Severe (3) Always On 2070 rpm 0 sec High Engine Coolant Least Severe (1) Always On 216 Deg F 30 sec Moderate Severity (2) On 225 Deg F 30 sec Most Severe (3) Off 230 Deg F 30 sec

High Engine Inlet Air Least Severe (1) On 158.0 Deg F 30 sec Moderate Severity (2) Off 174.2 Deg F 30 sec High Engine Oil Least Severe (1) On 221 Deg F 5 sec Moderate Severity (2) Off 239 Deg F 15 sec Most Severe (3) Off 239 Deg F 30 sec High Exhaust Least Severe (1) Off 1274 Deg F 5 sec High Fuel Filter Restriction Pressure Least Severe (1) On 20 psi 30 sec High Fuel Pressure Least Severe (1) On None 2 sec Moderate Severity (2) On None 30 sec Most Severe (3) Off None 30 sec High Fuel Least Severe (1) Always On 194.0 Deg F 30 sec Moderate Severity (2) Off 195.8 Deg F 30 sec Most Severe (3) Off 197.6 Deg F 30 sec High Oil Filter Differential Pressure Least Severe (1) On 16 psi 30 sec Low Aftercooler Coolant Level Least Severe (1) On None 30 sec Moderate Severity (2) Off None 30 sec Most Severe (3) Off None 30 sec Low Coolant Level Least Severe (1) On None 30 sec Moderate Severity (2) Off None 30 sec Low Engine Coolant Pressure Least Severe (1) On None 10 sec Moderate Severity (2) On None 130 sec Low Engine Oil Level Least Severe (1) On None 30 sec Moderate Severity (2) Off None 30 sec Low Engine Oil Pressure Least Severe (1) Always On None 8 sec Moderate Severity (2) On None 8 sec Most Severe (3) Off None 4 sec Low Fuel Level Least Severe (1) Off 13 % 300 sec Low Fuel Pressure Least Severe (1) On None 2 sec

Moderate Severity (2) Off None 30 sec Most Severe (3) Off None 30 sec Bridge Color MPD -Starbrd Parameter Value ECM Part Number 292-971301 ECM Serial Number 1294G001MU Software Group Part Number 306-306100 Software Group Release Date Software Group Description Configuration - Bridge Color MPD -Starbrd Description Value Unit Display Location Bridge Engine Location Starboard