EFFECT OF VORTEX SHEDDING ON THE STRUCTURAL INTEGRITY OF KURZ INSERTION MASS FLOW ELEMENTS

Similar documents
Wake Frequency Calculations Solid Drilled Thermowells

CFD Analysis of DHTW utilizing VE Technology A Helix Thermowell Design White Paper

THERMOWELL VIBRATION INVESTIGATION AND ANALYSIS

Sizing Thermowell according to ASME PTC 19.3

Vortex Induced Vibrations

Annubar Primary Element Flow Calculations

Experimental Aerodynamics. Experimental Aerodynamics

Target Insertion Flowmeter

Flow Measurement in Pipes and Ducts COURSE CONTENT

TitleOn the Design Wind Force of. Author(s) YOKOO, Yoshitsura; ISHIZAKI, Hatsuo.

2/23/ WIND PRESSURE FORMULA 2. PERCENT OF ALLOWABLE STRESS 3. FATIGUE DESIGN

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Centrifugal Compressor Root Cause Analysis. (Pulsation and Vibration Issues)

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Technical Data Sheet DPT & DPIT-4005 SERIES DIFFERENTIAL PRESSURE TRANSDUCERS. Features. Description

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Applied Fluid Mechanics

Applied Fluid Mechanics

Flow Measurement in Pipes and Ducts COURSE CONTENT

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Given Find Water Properties

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Flow Measurement in Pipes and Ducts

NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In. St Andrews, Scotland

STEADY, UNSTEADY AND LINEAR STABILITY OF FLOW PAST AN ELLIPTIC CYLINDER S.J.D. D'ALESSIO

Experiment No.4: Flow through Venturi meter. Background and Theory

Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras

SONAR-BASED VOLUMETRIC FLOW METER FOR CHEMICAL AND PETROCHEMICAL APPLICATIONS

NAME: Given Formulae: Law of Cosines: Law of Sines:

Student name: This is a closed book examination. You are allowed 1 sheet of 8.5 x 11 paper with notes.

Orifice and Venturi Pipe Flow Meters

MECHANICS OF MATERIALS. Prepared by Engr. John Paul Timola

Operating Instruction for the Thermowell Calculation Program according to ASME PTC 19.3 TW-2016

Large Rocket Engine Environments

STRUCTURAL ANALYSIS OF A WESTFALL 2800 MIXER, BETA = 0.8 GFS R1. By Kimbal A. Hall, PE. Submitted to: WESTFALL MANUFACTURING COMPANY

Orifice and Venturi Pipe Flow Meters

Mechanical Principles

Learning Objectives. Lesson 6: Mathematical Models of Fluid Flow Components. ET 438a Automatic Control Systems Technology 8/27/2015

Numerical Simulation of Unsteady Flow with Vortex Shedding Around Circular Cylinder

Due Date 1 (for confirmation of final grade): Monday May 10 at 11:59pm Due Date 2 (absolute latest possible submission): Friday May 14 at 5pm

External Forced Convection. Copyright The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

DESIGN AND ANALYSIS OF LIGHT WEIGHT MOTOR VEHICLE FLYWHEEL M.LAVAKUMAR #1, R.PRASANNA SRINIVAS* 2

Given Find Water Properties

High Harmonic Forces and Predicted Vibrations from Forced In-line and Cross-flow Cylinder Motions

Global J. of Mech., Engg. & Comp. Sciences, 2012: 2 (1)

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

UNIT II CONVECTION HEAT TRANSFER

Vortex Flow Meters. RVL Series Vortex Flow Meter

Fluids and their Properties

FDE 211 MATERIAL & ENERGY BALANCES. Instructor: Dr. Ilgin Paker Yikici Fall 2015

93. Study on the vibration characteristics of structural of hydrocyclone based on fluid structure interaction

Lecture-04 Design of RC Members for Shear and Torsion

Chapter 6. Losses due to Fluid Friction

FINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT. FINAL DRAFT: October 25, 2010 Page 0

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

Flow Monitoring Technologies in Oil and Gas. Don Ford, Technical Specialist Spartan Controls Ltd.

Bluff Body, Viscous Flow Characteristics ( Immersed Bodies)

OMAE FLUID-STRUCTURE INTERACTION MODELING OF SUBSEA JUMPER PIPE

Application of an ultrasonic velocity profile monitor in a hydraulic laboratory

Review on Vortex-Induced Vibration for Wave Propagation Class

Self-Excited Vibration in Hydraulic Ball Check Valve

Boundary-Layer Transition Measurements in a Mach-6 Quiet Tunnel

MAAE 2202 A. Come to the PASS workshop with your mock exam complete. During the workshop you can work with other students to review your work.

M E 320 Professor John M. Cimbala Lecture 38

FVBSS fixed volume bottle

Aerodynamic Characteristics of Flow over Circular Cylinders with Patterned Surface

Applied Fluid Mechanics

Rate of Flow Quantity of fluid passing through any section (area) per unit time

CVEN Fall 2009 Examination 1 October 5, :00 pm 8:40 pm

ASME V&V Authors: Marcus Gamino Samuel Abankwa Ricardo Silva Edwin Johnson Michael Fisher

White Paper FINAL REPORT AN EVALUATION OF THE HYDRODYNAMICS MECHANISMS WHICH DRIVE THE PERFORMANCE OF THE WESTFALL STATIC MIXER.

Applications of Eigenvalues & Eigenvectors

Fluid Dynamics Exam #1: Introduction, fluid statics, and the Bernoulli equation March 2, 2016, 7:00 p.m. 8:40 p.m. in CE 118

The online of midterm-tests of Fluid Mechanics 1

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can

Addendum to ARI Standard , Air Terminals September 2002

COMPUTER AIDED ANALYSES OF SMOKE STACK DESIGNS

Rapid Averaging Probe (RAP)

Thermal & Fluids PE Exam Technical Study Guide Errata

Experimental Investigation of the Aerodynamic Forces and Pressures on Dome Roofs: Reynolds Number Effects

DESIGN AND PERFORMANCE OF THE CONVERGING-DIVERGING VORTEX FLOWMETER

Non Newtonian Fluid Dynamics

V-Cone Flowmeter DATASHEET

Final 1. (25) 2. (10) 3. (10) 4. (10) 5. (10) 6. (10) TOTAL = HW = % MIDTERM = % FINAL = % COURSE GRADE =

Smallbore. Definition of a Cutoff Natural Frequency for. Jim McGhee, Xodus Group

Insights on vortex-induced, traveling waves on long risers

Heat Transfer F12-ENG Lab #4 Forced convection School of Engineering, UC Merced.

Dynamic Response in a Pipe String during Drop-Catch in a Wellbore

Vibrations of Chimneys under the Action of the Wind

Note that W is the skin surface weight density in units of psf. An equivalent graph in terms of metric units is given in Appendix A.

ME411 Engineering Measurement & Instrumentation. Winter 2017 Lecture 11

Flow Measurement: Physical principle employed in various types of flow meters. PART 4 PREPARED BY: ESO OLUWATOBILOBA

US06CPHY06 Instrumentation and Sensors UNIT 2 Part 2 Pressure Measurements

Review of the Master SN Neuber Rule in the ASME Division 2 Rewrite Project

Alden Test Results On AMITY Insert Venturi

(48) CHAPTER 3: TORSION

SELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes

Lab #4 Similitude: The Kármán Vortex Street CEE 331 Fall 2004

o0, and since the period of vibration of the scale is related to the mass,

The LAT Electronics consists of five distinct box assemblies as follows:

Transcription:

EFFECT OF VORTEX SHEDDING ON THE STRUCTURAL INTEGRITY OF KURZ INSERTION MASS FLOW ELEMENTS EFFECT OF VORTEX SHEDDING ON THE STRUCTURAL INTEGRITY OF KURZ INSERTION MASS FLOW ELEMENTS DCN 364017 Rev 1 # http://www.kurz-instruments.com 1

EFFECT OF VORTEX SHEDDING ON THE STRUCTURAL INTEGRITY OF KURZ INSERTION MASS FLOW METERS I. INTRODUCTION Equations are developed to calculate the vibration and structural characteristics of the Kurz Series 450 and K-BAR Insertion Mass flow Elements. These include the natural frequency of the sensor support tube, the vortex shedding frequency, and stress caused by vortex shedding. Vortex shedding occurs over a Reynolds Number range of approximately 50 to 5000 for circular cylinders. Vortex generation above a Reynolds Number of 5000 is not stable and may not cause resonance problems. In fact, Murdock (ASME Journal October 1959) stated that all attempts to obtain resonance during experimental tests failed. One reason is that shedding over all portions of a long cylindrical bar is not synchronized. Table 1 gives the lower and upper free stream velocity for three sizes of Insertion Mass flow Elements manufactured by Kurz Instruments to cause vortex shedding. PRODUCT SUPPORT DIAMETER VELOCITY (FPM) UNDER STANDARD CONDITIONS Re = 50 Re = 5000 Series 450-08 1/" 11.75 1175 Series 450-16 1" 5.87 587 Series K-BAR4 1 1/" 3.9 39 Table 1 The table shows that vortex shedding occurs at very low velocities, such that the velocity pressure is also very small. This means that the stress produced, even near resonance is also very small compared to the allowable stress of 30,000 PSI for stainless steel, at least for low pressure and temperature situations normally encountered n thermal mass flow meter applications. If liquid or extremely high pressures were used at very high velocities, one would have reason for concern. Since these situations generally have Reynolds Numbers much larger than 5000, our conclusion is that the effect is greatly exaggerated as a failure mechanism, at least for our type of instrument. II ASSUMPTIONS 1) The force caused by vortex shedding is equal to drag caused by the gas velocity pressure, where the drag coefficient C D = 1.0 (Data shows this is very conservative). ) The Damping Factor is between.01 and.05 per the Engineering Handbook. 3) The sensor support window is considered to be a solid tube, although it is open and gas flow through it (this is also a conservative assumption). 4) E = 9 x 10 6 PSI. 5) F ALLOW = 30,000 PSI. DCN 364017 Rev 1 # http://www.kurz-instruments.com

EFFECT OF VORTEX SHEDDING ON THE STRUCTURAL INTEGRITY OF KURZ INSERTION MASS FLOW ELEMENTS 6) Material is 316SS or equal, density = 488 lb/ft 3. 7) Sensor support is cantilever mounted, with no end support. 8) Vortex shedding occurs above a Reynolds Number of 5000, although this is unsupported in the literature and highly conservative. III GENERAL OBSERVATIONS 1) Because of typical support size, length, and typical velocities in ducts, the vortex frequency is normally considerably higher than the natural frequency of the support and the force magnification factor is very small. The gas velocity pressure at resonance is so low that forces are negligible (the force is measured inches of water because of the low velocity). ) We have not encountered a resonance condition caused by vortex shedding at any of our thousands of installations, nor have we had a failure due to vortex shedding. 3) We essentially followed basic assumptions of the ASME Power Test Code Method for thermowells by J.W. Murdock (October 1959), however, our problem is quite different in that the velocity pressure is very small, as are the temperature and gas pressures. 4) In most cases the vortex shedding frequency is much higher than the natural frequency of the sensor support, as is the case for automobile antennas. I think we can safely say that automobile antennas do not exhibit a measurable failure rate due to vortex shedding! IV EQUATIONS AND TERMS A) Equations 1) ',418 D % d L ) p a '.0748 MW 9 x P a P S T S T a 3) f w '.64 m P a A D 4) F M ' 1 & f W 1 % * 5) ' 1.576 x 104 (L&.5L 1 ) L 1 D 4 D a f W (D 4 & d 4 ) DCN 364017 Rev 1 # http://www.kurz-instruments.com 3

EFFECT OF VORTEX SHEDDING ON THE STRUCTURAL INTEGRITY OF KURZ INSERTION MASS FLOW METERS 6) * DYN ' ± F M 7) * g ' 1.13 L D D % d 8) * MAX ' * g % * DYN B) Terms D = Sensor Support Diameter (inches) d = Inside Diameter of Sensor Support (inches) L = Unsupported Length of Sensor Support (inches) A = Flow Area of Duct or Stack (FT ) m = Mass of Gas (lbm/sec) D a = Actual Density of Gas (lbm/ft 3 ) P a = Absolute Pressure of Gas (PSIA) P s = Absolute Pressure of Gas at Standard Conditions (14.7 PSIA) MW = Gas Molecular Weight T S = Standard Temperature, 537 R T a = Actual Temperature of Gas R * = Damping Factor, (.01 -.05) f W = Vortex Shedding Wake Frequency (Hz) = Natural Frequency of Sensor Support (Hz) F M = Force Magnification Factor L 1 = Length of Sensor Exposed to Flow (Inches), Includes Shield = Maximum Stress at Sensor Support (PSI) Caused by Gas Flow Force * DYN = Stress at Sensor Support (PSI) Caused by Vortex Shedding DCN 364017 Rev 1 # http://www.kurz-instruments.com 4

EFFECT OF VORTEX SHEDDING ON THE STRUCTURAL INTEGRITY OF KURZ INSERTION MASS FLOW ELEMENTS * g = Stress at Sensor Support Caused by Weight of Support * MAX = Sum of Stresses, * DYN, * g Typical Series 450 Geometry V. EXAMPLES Example A: Moderate Flare Gas Application Velocity Process Pipe has 3.5" Diameter. A =.948 Ft D = 1", Series 450-16 Insertion Mass Flow Element d = 0.87" L = 19.54" L 1 = 4." (Centerline of sensor placed at equal area location of pipe) m = 3.9 lbm/sec P a = 7.8 PSI =.5 PSIA DCN 364017 Rev 1 # http://www.kurz-instruments.com 5

EFFECT OF VORTEX SHEDDING ON THE STRUCTURAL INTEGRITY OF KURZ INSERTION MASS FLOW METERS P S = 14.7 PSIA MW = 54.63 T a = 198 F = 658 R T S = 537 R * =.01 Results: 1) Natural Frequency ',418 D %d L ' 77.83 Hz ) Gas Density D a '.0748 MW 9 x P a P S T s T a '.1760lbm/FT 3 3) Vortex Shedding Frequency f W '.64 m D A D ' 11.61 Hz 4) Force Magnification Factor F M ' 1 1 & f W % * '.69374 5) Maximum Stress at Sensor Support (PSI) Caused by Gas Flow Force ' 1.576 x 10& 4 (L&.5L 1 ) L 1 D 4 D a f w (D 4 & d 4 ) ' 69.907 PSI 6) Stress at Sensor Support (PSI) Caused by Vortex Shedding * DYN ' ± F M ' 69.91 ± 48.5 PSI DCN 364017 Rev 1 # http://www.kurz-instruments.com 6

EFFECT OF VORTEX SHEDDING ON THE STRUCTURAL INTEGRITY OF KURZ INSERTION MASS FLOW ELEMENTS 7) Stress at Sensor Support Caused by Weight of Support * g ' 1.13 L D D % d ' 45.6 PSI 8) Maximum Stress at Sensor Support * MAX ' * g % * DYN ' 315.5 ± 48.5 ' «30,000 ALLOWABLE PSI No Failure at Maximum Flow Conditions Example B: High Flare Gas Application Velocity Process Pipe has 15.5" Diameter. A = 1.684 FT D = 1" Series 450-16 Mass Flow Element d = 0.87" L = 15.35" +.34" +.78" = 18.36" L 1 = 3.014" (Centerline of sensor placed at equal area location of pipe) m = 80.975 lbm/sec P a = 6 PSIG = 0.7 PSIA P s = 14.7 PSIA MW = 53.85 T a = 165 F = 65 R T s = 537 R * =.01 Results 1) Natural Frequency ',418 D % d L ' 88.15 Hz DCN 364017 Rev 1 # http://www.kurz-instruments.com 7

EFFECT OF VORTEX SHEDDING ON THE STRUCTURAL INTEGRITY OF KURZ INSERTION MASS FLOW METERS ) Gas Density D a '.0748 MW 9 x P a P S T S T a '.16804 lbm/ft 3 3) Vortex Shedding Frequency f w '.64 m D a A D ' 1003 Hz 4) Force Magnification Factor F M ' 1 1 & f W % * '.007784 5) Maximum Stress at Sensor Support (PSI) Caused by Gas Flow Force ' 1.576 x 10& 4 (L &.5L 1 ) L 1 D 4 D a f W (D 4 & d 4 ) ' 3169 PSI 6) Stress at Sensor Support (PSI) Caused by Vortex Shedding * DYN ' ± F M ' 3169 ± 4.67 PSI 7) Stress at Sensor Support Caused by Weight of Support * g ' 1.13 L D D % d ' 16.81 PSI 8) Maximum Stress at Sensor Support * MAX ' * g % * DYN ' 3386 ± 4.67 PSI «30,000 ALLOWABLE PSI No Failure at Maximum Flow Conditions DCN 364017 Rev 1 # http://www.kurz-instruments.com 8