THE INFLUENCE OF PUMPS ON SURFACE PREPARATION

Similar documents
Effect of Pump Induced Particle Agglomeration On CMP of Ultra Low k Dielectrics

Surface Mediated Particle-particle Aggregation During CMP Slurry Delivery and Handling

QUANTIFICATION OF PARTICLE AGGLOMERATION DURING CHEMICAL MECHANICAL POLISHING OF METALS AND DIELECTRICS

PARTICLE ADHESION AND REMOVAL IN POST-CMP APPLICATIONS

The Removal of Nanoparticles from Nanotrenches Using Megasonics

Effects of Size, Humidity, and Aging on Particle Removal

Trace Metal Dynamic Extraction from Five Pumps in Hydrochloric Acid. Submitted to: Reto Schoeb Levitronix GmbH. Submitted by:

MEGASONIC CLEANING OF WAFERS IN ELECTROLYTE SOLUTIONS: POSSIBLE ROLE OF ELECTRO-ACOUSTIC AND CAVITATION EFFECTS. The University of Arizona, Tucson

THE EFFECT OF SAMPLE SIZE, TURBULENCE INTENSITY AND THE VELOCITY FIELD ON THE EXPERIMENTAL ACCURACY OF ENSEMBLE AVERAGED PIV MEASUREMENTS

Effect of Liquid Viscosity on Sloshing in A Rectangular Tank

Method Development. Creating the Perfect Standard Operating Procedure (SOP) 2007 HORIBA, Ltd. All rights reserved.

PIV Applications to Thermal Performance of LPG

Experimental and Analytical Study of Submicrometer Particle Removal from Deep Trenches

SIMULTANEOUS VELOCITY AND CONCENTRATION MEASUREMENTS OF A TURBULENT JET MIXING FLOW

Particle Image Velocimetry Investigations of Turbulence in Superfluid Helium. S. W. Van Sciver

Holographic Characterization of Agglomerates in CMP Slurries

Experiments on the perturbation of a channel flow by a triangular ripple

Simultaneous Velocity and Concentration Measurements of a Turbulent Jet Mixing Flow

SPCC Department of Bio-Nano Technology and 2 Materials Science and Chemical Engineering, Hanyang University, Ansan, 15588, Republic of Korea.

Defect management and control. Tsuyoshi Moriya, PhD Senior Manager Tokyo Electron Limited

Micro-Flow in a bundle of micro-pillars. A. Keißner, Ch. Brücker

Applied Fluid Mechanics

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

Abstract Particle image velocimetry (PIV)

Figure 1. Schematic of experimental setup.

Protocol Particle size distribution by centrifugal sedimentation (CPS)

Investigation of Transonic Flow Behavior around a Three- Dimensional Turret Using Particle Image Velocimetry

Applied Fluid Mechanics

Cells in double emulsions for FACS sorting

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

DRY METHOD DEVELOPMENT FOR LASER DIFFRACTION PARTICLE SIZE MEASUREMENTS

Dynamics of Large Scale Motions in Bubble-Driven Turbulent Flow

Chapter 5 Control Volume Approach and Continuity Equation

Post Tungsten CMP Cleaner Development with Improved Organic and Particle Residue Removal on Silicon Nitride and Excellent Tungsten Compatibility

REAL-TIME MONITORING OF STRIATION DEVELOPMENT DURING SPIN-ON-GLASS DEPOSITION

Enhanced Boiling Heat Transfer by using micropin-finned surfaces for Electronic Cooling

XBC300 Gen2. Fully-automated debonder and Cleaner

Spring Lecture 4 Contamination Control and Substrate Cleaning. Nanometer Scale Patterning and Processing

1

Experimental and Numerical Investigation of Two- Phase Flow through Enlarging Singularity

Lecture 6. Rapid Thermal Processing. Reading: Chapter 6

Transition of laminar pre-mixed flames to turbulence - induced by sub-breakdown applied voltage

CT Associates, Inc. Trace Metal Dynamic Extraction from Three Centrifugal Pumps in Hydrochloric Acid. Submitted to: Juergen Hahn Levitronix GmbH

Natural Convection Heat Loss from A Partly Open Cubic Enclosure Timothy N Anderson 1,a * and Stuart E Norris 2,b

Lecture 16 Chemical Mechanical Planarization

Thin Wafer Handling Challenges and Emerging Solutions

Utilizing Adaptive Focused Acoustics (AFA) Technology to Control Nucleation and Crystal Distribution During API Crystallization

Slide 1 Raymond Jin, Adcon Lab, Inc.

THE EFFECT OF TWO PHASE (AIR-WATER) FLOW CHARACTERISTICS ON MOMENTUM FLUX DUE TO FLOW TURNING ELEMENTS AT ATMOSPHERIC CONDITIONS

FEATURE ARTICLE. The CS-100 Series High-precision Chemical Solution Monitor in the Semiconductor Cleaning Process. Takaaki Yada.

The Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical Planarization by Single Particle ICP-MS

Solar Flat Plate Thermal Collector

NANO AND MICROSCALE PARTICLE REMOVAL

ECHE Questions Centrifugal Pumps

Effect of Incoming Quality of Sulfuric Acid on Inline Defects

Fluid Mechanics Prof. T.I. Eldho Department of Civil Engineering Indian Institute of Technology, Bombay. Lecture - 17 Laminar and Turbulent flows

The solution for all of your

ANALYSIS OF TURBULENT FLOW IN THE IMPELLER OF A CHEMICAL PUMP

Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals

The CMP Slurry Monitor - Background

White Paper FINAL REPORT AN EVALUATION OF THE HYDRODYNAMICS MECHANISMS WHICH DRIVE THE PERFORMANCE OF THE WESTFALL STATIC MIXER.

Mechanisms of Vortex Oscillation in a Fluidic Flow Meter

Effect of Soft Agglomerates on CMP Slurry Performance

Direct Observation of Wet Biological Samples by. Graphene Liquid Cell Transmission Electron Microscopy

Efficient Cleaning Of Silicon Wafers Using Ultrasonic

next generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size

Model 2300XP PSL & Process-Particle Wafer Deposition System

Theory and Design for Mechanical Measurements

5. 3P PIV Measurements

PIV Measurements of the Influence of Seeding Particles Concentration on the Velocity of an EHD Flow

Turbulence Laboratory

Density Field Measurement by Digital Laser Speckle Photography

CHAPTER 4 THERMAL CONDUCTIVITY AND VISCOSITY MEASUREMENTS

Given Find Water Properties

A method for imaging and spectroscopy. using γ-rays and magnetic resonance

Effect of Particle Size on Thermal Conductivity and Viscosity of Magnetite Nanofluids

2. (a) Differentiate between rare metal thermocouples and base metal thermocouples.

BACHELOR OF TECHNOLOGY IN MECHANICAL ENGINEERING (COMPUTER INTEGRATED MANUFACTURING)

Evaluation of Cleaning Methods for Multilayer Diffraction Gratings

Fundamentals of Particle Counting

Nano-sized ceria abrasive for advanced polishing applications in IC manufacturing

Given Find Water Properties

637. Thiamethoxam. HPLC method

How DLS Works: Interference of Light

Determination of zeta potential by means of a rotating disk: planar, particulate, and porous samples!

SurPASS. Electrokinetic Analyzer for Solid Samples. ::: Innovation in Materials Science

(Refer Slide Time 1:25)

PIV measurements of turbulence in an inertial particle plume in an unstratified ambient

Characteristics of CO2 Transcritical Expansion Process

Supplementary Figure 1 Surface tension of polyelectrolyte solutions. Experimentally measured values of surface tension of the solutions that were

Industrial In-line and Multi Component Monitor Using Absorption Spectroscopy and Its Application

Supporting Information

Measuring sub-50nm particle retention of UPW filters

Solutions for Assignment-6

Applications in Biofluidics

Velocity profiles of fluid flow close to a hydrophobic surface

PIV-INVESTIGATIONS OF INTERNAL SLIT NOZZLE FLOWS AND THEIR INFLUENCE ON LIQUID SHEET BREAKUP

Supplementary Figure 1 Detailed illustration on the fabrication process of templatestripped

Laboratory 3: Confocal Microscopy Imaging of Single Emitter Fluorescence and Hanbury Brown, and Twiss Setup for Photon Antibunching

CURRENT STATUS OF NANOIMPRINT LITHOGRAPHY DEVELOPMENT IN CNMM

Transcription:

THE INFLUENCE OF PUMPS ON SURFACE PREPARATION A Final Report (Sep 2010 Dec 2010) Submitted by Prof. Jin-Goo Park Department of Materials Engineering Hanyang University, Ansan, 426-791, Korea To LEVITRONIX, Dec. 31, 2010 1

TABLE OF CONTENTS 1 INTRODUCTION 1 2 OBJECTIVES 2 3 METHODOLOGIES 2 4 EXPERIMENTS 4.1 Wafer cleaning Experiments 3 4.2 PIV Measurements 5 5 RESULTS & DISCUSSION 5.1 Effect of pumping methods on wafer cleaning in wet bath 7 5.1.1 Seven wafers test 7 5.1.2 Single wafer test 9 5.2 Effect of pumping methods on wafer cleaning in Single Akrion tool 11 5.3 Effect of pumping methods on temperature rise of the solution 12 5.4 Effect of pumping methods on flow behavior in the wet bath 13 6 SUMMARY 13 7 FUTURE WORK 14 8 REFERNCES 14 2

1. INTRODUCTION Various types of pump such as bellows, diaphragms and centrifugal have been used in microelectronic processing industries for range of applications. In principle, the flow delivery is pulsatile in positive displacement pumps (bellow and diaphragms) whereas continuous in magnetic levitation pumps. This would influence the performance of various processes in surface preparation such as cleaning and etching etc. The summary of studies explaining how the pumping methods can affect the various processes is given below. One report shows that pump pulsation intensity increases with flow rate of the slurry for bellow and diaphragm pumps whereas it is constant for MegLev centrifugal pumps. Hence the flow in the centrifugal pump is more stable [1] in slurry supply. Particle generation and agglomeration are the major concerns in the slurry circulation through pumps as they affect the process efficiency. The operation of pump generates particles because of moving parts such as diaphragms and the seating of the valve [2]. On the other side, various factors cause the particle agglomeration when the liquid is subjected to circulation through pump which includes shear stress, mechanical contact between slurry and the pump and cavitation. Shear stress exhibits on the liquid when it is subjected to high velocity gradients. For example, flow though orifice and orifice meter and flow across a diaphragm seat [3]. The degree of level of agglomeration depends on inter particle force, external shear stress which in turn depends on type of pump that used in the process line and number of turnovers of slurry [4]. However, shear stress also breaks loose agglomerates. The dominating mechanism is determined by the magnitude of shear level imparted to the liquid and the force of attraction /repulsion between particles [3]. In the case of positive displacement pump, high shear flow increases the oversized particle [5] thereby affects the process efficiency. Similarly mechanical contact between pump and the slurry particles results in particle agglomeration. The circulating effect of Cabot silica slurry (EP-C6618) on the health of slurry was studied with four different pumps including diaphragm (Yamada, PFD3 3226), bellows (ASTI, DP20F-FT) and medium (Levitronix, BPS-3) and high (Levitronix, BPS-4) magnetically levitated centrifugal pumps [6]. The studies showed that the cumulative particle 3

size distribution (PSD) in the slurry after circulation increased with increasing turnovers in diaphragm and bellow pumps while there is only minimal change is observed with both the MegLev centrifugal pumps. The increase in oversized particle concentration affects the various processes such as chemical mechanical polishing [4, 7], particle retention on the filter [1] etc. In addition, cavitation also leads to particle agglomeration. It is reported that cavitation is the primary mechanism in bellow and diaphragm pumps for particle agglomeration that eventually affect the CMP performance. It is also reported that the bellow pump creates more number of bubbles when compared to centrifugal pump (Levitronix, BSM 3.1C) if a nonionic surfactant, triton X, is used in the solution [8]. On the whole, all the studies show that the levitation magnetic pumps perform much better than positive displacement pumps. However to the authors knowledge, there is no experimental evidence on the effect of centrifugal and diaphragms pump on cleaning process performance in microelectronic processing industries. Thus in this present project, the focus is on the influence of pumps on surface preparation. The objectives and the methodologies of this present work have been set as follows 2. OBJECTIVES 1. To study the effect of pumping methods (diaphragm vs. magnetic levitation pump) on cleaning and particles 2. To investigate the fluid flow behavior in the tank with and without pulsation 3. METHODOLOGIES To meet the above objectives, the following methodologies have been framed. 1) To study the effect of pumping methods on cleaning and particle i. The effect of centrifugal pump at different flow rates on wafer cleaning in single wafer tool and conventional wet bath tool 4

ii. The effect of diaphragms pump at different flow rates on wafer cleaning in single wafer tool and conventional wet bath tool iii. The particle counting on wafer before and after the cleaning process to estimate the particle addition on wafer during pumping by using a laser surface particle scanner 2) To investigate the fluid flow in the tank with and without pulsation i. Particle image velocity (PIV) measurements to investigate the fluid flow in the tank with both in the presence and absence of pulsation ii. The image post processing and image analysis to analyze the experimental results iii. Finally, the results obtained from the PIV results would be integrated with particle addition to show the relationship between fluid dynamics and particle generation during pumping 4. EXPERIMENTAL PROCEDURE 4.1 Cleaning experiments The wet bath and single tool was modified accordingly to accomplish the circulation cleaning experiments. The schematic diagram and photograph of modified experimental set up is shown in Fig. 1(a-d). The flow rate and pressure of the circulation system was monitored by rotameter and pressure gauge, respectively. Three pumps were tested in the present work and specifications of the same are given in the Table 1. After connecting the pump to the circulation line, the whole system is flushed with DI water for 24 hours before the actual run in order to remove the particles generated during the initial pumping. In the present cleaning study, only DI water was used for all the runs. 8 inches bare silicon wafers were used in this study. Prior to the experiments, wafers were cleaned with SC1 (NH 4 OH+H 2 O 2 +DIW) solution with megasonic for 10 minutes in wet bath and dried in Single Akrion tool for 30 seconds to ensure that the surface is hydrophilic. The particle counts on the wafers were measured using surface scanner (ST6600, KLA Tencor, USA). Then, the 24 hours cleaning experiments were carried out in two different approaches. In the first approach, wafers are immersed in the wet bath for the process time of 10 minutes at the end of designated times i.e. 0, 4, 8, 12, 16, 20 and 24 hour followed by 5

drying in the single tool. Then, the particle count on these dried wafers was measured again by surface scanner. The difference in the particle count before and after the cleaning experiment would give the particle added on the wafer during the processing time. This approach is termed as seven wafers test in the succeeding sections. In the second approach, the wafer is immersed in the bath for 24 hours and taken out from the bath only at the designated times, dried in a single tool and analyzed for particle count using surface scanner and immersed back again in the bath. This test is termed as single wafer test in the pursuing sections. In conventional wet bath, experiments were conducted at different flow rates i.e. at 10, 15 and 20 LPM for BPS 600 pump and at 10 and 15 LPM for both the diaphragm pumps. Since the maximum flow rate achieved in both the diaphragm pumps is 15 LPM, the experiments were not carried out at 20 LPM. The constant pressure of 30 psi was maintained in all the experiments. However, in both the diaphragms, the pressure was fluctuating around the value of 30 psi. Temperature of the solution was also monitored during the circulation. In single tool, the feeding conditions of chemical are internally fixed in the tool. Thus the experiments were conducted at only one test condition. The detailed test conditions of experiments carried out in both conventional wet bath and Single Akrion tool are given in Table 2 (a) 6

(b) (c) (d) Fig. 1. Modified conventional wet bath tool with pump circulation for cleaning experiments; (a) schematic diagram of bath with a pump and (b) its photograph (c) Schematic diagram of Single Akrion tool and (d) its photograph 7

Table 1: Specifications of pumps used in this present study BPS- 600 Magnum 620r Futur 50 Maker Levitronix Trebor Almatec Type Centrifugal Diaphragm Diaphragm Max. Pressure 46 psi 80 psi 80 psi Max. Flow 75 LPM 45 LPM 50 LPM Max. Liquid Temp. 90 110 100 Table 2: Experimental test conditions employed in the present studies Pump Tool Test conditions Levitronix (BPS-600) Conventional wet bath Impeller speed:8000 rpm; Flow rate : 20,15 and 10 LPM; Pressure :30 psi Diaphragm I (Magnum 620r) Conventional wet bath Air pressure :1.8 bar; Flow rate : 15 and 10 LPM; Pressure :30±3 psi Diaphragm II (Futur 50) Conventional wet bath Air pressure :1.8 bar; Flow rate : 15 and 10 LPM; Pressure :30±6 psi All the three pumps Single Akrion DI water flow rate through nozzle: 0.5 LPM ; Circulation flow rate: Maximum flow rate of the pump 4.2 PIV Measurements PIV measuring technique (Lavision Model) is used to obtain the information on 2D instantaneous velocity flow field. In this measuring technique, the fluid in the tank is seeded with neutrally buoyant tracer particles (glass sphere 100μm ) and these particles are assumed to faithfully follow the fluid velocity. The area of interest is illuminated using a Laser source (Nd;YAG 532nm) and the light reflected by these particles in the laser sheet is captured using a high resolution (1280X1024 pix) CCD camera. Fig. 2a shows schematic diagram of PIV 8

measuring technique. The images of the particles are captured at two instants of time with the small time interval of milliseconds i.e. at the time t 0 and t o +Δt. The position of the particles in these images is used to estimate the instantaneous velocity vectors in the area of interest using cross correlation technique as explained in the Fig. 2b The data were processed using the software (DaVis Ver.6) provided by Lavsion to get the instantaneous velocity vector. 150 pairs of images were taken to determine the fluctuations of instantaneous velocity (a) (b) Fig. 2: (a) Schematic diagram of PIV measuring technique (b) Cross correlation technique to determine velocity in the area of interest from PIV images 5. RESULTS AND DISCUSSION 5.1 Effect of pumping methods on wafer cleaning in wet bath 5.1.1 Seven wafers test: The effect of pumping methods on the number of particles added on to the wafer during 24 hour cleaning test in wet bath is shown in the Fig. 3(a-c). In the case of BPS-600 pump, the total number of added particles on the wafer is below 5000 at all the flow rates. At higher flow rates (15 and 20 LPM), the particle count slightly decreases and becomes 9

constant with circulation time. This might be due to the particles which are shedded during the initial period of pumping attracting towards the wall and stick remains to it as the flow is smoother. However at the lower flow rate (10 LPM), particle count increases after 4 hours of circulation. The reason for this is not clear. In the case of both Magnum 620r and Futur 50, the particle count on the wafer goes beyond the inspection range of the instrument. The maximum measuring capability of the surface scanner instrument is. 30,000. If the wafer has particles which is beyond the instrument inspection range, then it could not detect the total number of particles and displays the error message. In that case, particle number on the wafer would be more than 30,000 and however just for the convenience, it is reported as 30,000 in the following plots. In both these pumps, the total number of added particles on the wafer increases with flow rate as seen from the Fig. 3(b-c). This behavior is more common in pumps as the particle shedding increases with the increase in flow rate [9]. Thus, it can be concluded from the 7 wafer test that number of particles generated by BPS-600 pump is very much lesser than both the diaphragm pumps. Number of Added Particles (ea) 35000 30000 25000 20000 15000 10000 5000 Out of inspection range 10LPM 15LPM 20LPM 0 0 4 8 12 16 20 24 Pump Circulation Time (hours) (a) 10

Number of Added Particles (ea) 35000 30000 25000 20000 15000 10000 5000 Out of inspection range 10LPM 15LPM 0 0 4 8 12 16 20 24 Pump Circulation Time (hours) (b) Number of Added Particles (ea) 35000 30000 25000 20000 15000 10000 5000 Out of inspection range 10LPM 15LPM 0 0 4 8 12 16 20 24 Pump Circulation Time (hours) (c) Fig. 3: Seven wafer test results of particle count on the wafer as a function of circulation time in wet bath tool for (a) Levitronix pump (b) Magnum 620r and (c) Futur 50 5.1.2 Single wafer test: The effect of pumping methods on the number of particles added on to the wafer in the single wafer test is shown in the Fig.4 (a-c). The total number of particles added on to the wafer during 24 hour circulation is 17,500 at 20 LPM and decreased to 11,000 at 10 LPM. It 11

clearly shows that number of added particles increase when the flow rate increases. In both Magnum 620r and Futur 50 pumps, the total number of particles added on to the wafer goes beyond the inspection range of the instrument at both the flow rates. Thus, single wafer test in wet bath also clearly shows that the added particles on the wafer is very much lesser in BPS- 600 than the other two pumps. 35000 30000 Out of inspection range Number of Particles (ea) 25000 20000 15000 10000 5000 10LPM 15 LPM 20 LPM 0 0 4 8 12 16 20 24 Pump Circulation Time (hours) 35000 30000 Out of inspection range Number of Particles (ea) 25000 20000 15000 10000 10LPM 15LPM 5000 0 0 4 8 12 16 20 24 Pump Circulation Time (hours) (b) 12

35000 30000 Out of inspection range Number of Particles (ea) 25000 20000 15000 10000 10LPM 15LPM 5000 0 0 4 8 12 16 20 24 Pump Circulation Time (hours) (c) Fig. 4: Single wafer test results of particle count on the wafer as a function of circulation time in wet bath tool for a. Levitronix pump b. Magnum 620r and c. Futur 50 5.2 Effect of pumping methods on wafer cleaning in single tool The effect of pumping methods on the number of particles added on to the wafer during 24 hour cleaning test in single Akrion tool is shown in the Fig. 5. In BPS -600 pump, the total number of particles added on to the wafer is very less (i.e. around 300) and there is no significant change in the number with circulation time. The trend looks similar with the Futur 50 pump though particle number (500) is slightly higher. However, the particle count slightly increases with circulation time especially after 12 hours. In the case of Magnum620r pump, the wafer particle count is relatively higher (4200 at 24 th hour) and increases linearly with circulation time. The particle number is significantly lower in this test compared to that of test carried out in the wet bath. This is mainly due to the lower process time and also most of the particles escaped from the feed line as a separate branch from the circulation line is used for supplying DI water to the single tool. 13

Number of added particles (ea) 4500 4000 3500 3000 2500 2000 1500 1000 500 BPS 600 Magnum 620R Futur 50 0 0 4 8 12 16 20 24 Pump Circulation Time (hours) Fig.5 : Particle count on the wafer as a function of circulation time in Single tool for the three pumps. 5.3. Effect of pumping methods on temperature rise during cleaning experiments In general, there is a power loss within the pump due to the difference in the brake horsepower and water horsepower developed. These power losses are converted in to heat and results in a temperature rise of the liquid being pumped. Thus temperature of the circulating DI water was monitored with respect to circulation time for all the three pumps and for all the flow rates. The results are shown in the Fig. 6. It clearly shows that there is a rise in the temperature of DI water during first four hours of circulation and after that there is no significant change in the temperature for all the three pumps. The temperature rise is relatively higher for magnetic levitation pumps when compared to both the diaphragm pumps at all the flow rates as seen from the figure 3. The operating condition such as flow rate also affects the temperature rise of liquid. The effect is more pronounced for BPS - 600 pumps i.e. ΔT is 17ºC at 10 LPM and increased to 21ºC at 20 LPM. In the case of Magnum 620r and Futur 50, the ΔT is 8ºC and 9ºC respectively at 10 LPM and increased only to 10ºC when the flow rate was changed to 15 LPM. 14

25 20 Δ T ( ) 15 10 5 BPS 600 @10LPM BPS 600 @15LPM BPS 600 @20LPM Magnum620r @10LPM Magnum620r @15LPM FUTUR 50 @10LPM FUTUR 50 @15LPM 0 0 4 8 12 16 20 24 Pump Circulation Time (hours) Fig. 6: Temperature rise of DI water as a function circulation time for the three pumps at various flow rates 5.4 PIV Measurements The measurement of velocity field in the plane of interest [the region of PQRS in the figure] was made in the rectangular tank using PIV technique for the pumps without pulsation (BPS -600) and with pulsation (Magnum 620r and Futur 50). PIV measurements were made after 10 minutes of pump circulation to overcome the transient behavior of the system during initial pumping. In the preset test, during the pumping, specifically in our experimental set up, lots of bubbles generated with all the three pumps and spread all over the tank. As bubbles also reflect light, this will interfere with the reflecting light from the seed particles and affect the PIV results. Thus, the PIV results shown here are not most reliable. However, some information is inferred from the present measurements which are given below. As mentioned earlier, totally 150 pairs of images were acquired for each pump. It gives totally 300 events of velocity field as each event is obtained from pair of images. The velocity field acquired at two different events (4 th and 5 th event) i.e. at two different time 15

instants for all the three pumps is given in the Fig.7 (a-c) and Fig. 8(a-c). It is seen that velocity fields are sufficiently distinct from each other confirming the transient behavior of the system. In addition, the magnitude of most of the vectors is near the value of 1.5 m/s for BPS -600 pump whereas for the other two pumps the range is wide as seen in the figures. This confirms that the flow is relatively more uniform in the wet bath with BPS 600 when compared to that of other two pumps. (a) (b) (c) Fig.7 : The velocity field acquired at the 4 th event for (a) BPS 600 (b) Magnum 620r and (c) Futur 50 (a) (b) (c) Fig.8. The velocity field acquired at the 5 th event for (a) BPS 600 (b) Magnum 620r and (c) Futur 50 The time averaged flow field estimated from the 300 events for all the three pumps is shown in the Fig. 9 (a-c). It can be seen that vectors are in the downward direction in the left 16

hand side of the plane These downward velocity vectors appeared earlier in the velocity field for BPS-600 pump than the other two pumps as observed from the Fig.7 and Fig.8. It says that steady state is reached in a very less time in BPS-600 pump than in the other two diaphragm pump. (a) (b) (c) Fig. 9 Time averaged flow field in the region of interest for (a) BPS 600 (b) Magnum 620r and (c) Futur 50 The present PIV set up has only single camera which allow us to steady only the 2D (X and Y component velocity) velocity field. If the Z component velocity also has significant value, then it may also influence the PIV results. Thus the PIV measurement results could be improved by 1. Using two cameras simultaneously in the PIV measurements to determine the 3D velocity field. 2. Using rhodamine coated particles which emit only red light as seed particles and suitable optical filter in front of camera which allows only the red light emitted from seed particles to record. This way, one could minimize the interference of bubbles in liquid flow studies. However, in given comparison, BPS 600 gave uniform flow distribution and reached a steady state flow in a shorter time than Magnum and Futur pumps. 17

6. SUMMARY 1. Both Seven wafers test and single wafer test in conventional wet bath show that number of added particles on the wafer is very much lesser in BPS 600 pump than the both Magnum 620R and Futur 50 pumps 2. In Single Akrion tool, since the process time is very less, there is no significant difference observed in the added particle number between BPS -600 pump and Futur 50 pump. However, the particle number is relatively higher in Magnum 620r. 3. The temperature rise of the DI water during circulation is higher in BPS -600 pump than Magnum 620r and Futur 50 pumps. 4. Since all the pumps being studied in the present work produce lot of bubbles, the flow behavior in the wet bath was difficult to analyze. However, in given comparison, more uniform flow and faster steady state flow were observed in BPS pump. 7. FUTURE WORK: 1. In general, the stability of chemicals is affected by various factors. For example, hydrogen peroxide used in SC1 cleaning is dissociating in to hydrogen and oxygen with respect to time and the dissociation is accelerated by various means such as presence of impurities, temperature etc. Hence the pulsation and pump inducted particles may have influence on the stability of chemicals. Thus, the effect of pumping methods on the stability of SC1 chemicals will be of interest. 2. The effect of pumping methods on the etching uniformity of the bare or patterned wafers. If knowledge is given, the dependency on etch rate on kind of films would be very interesting to investigate. 3. It is observed that higher pump pulsation intensity leads to the vibration of the experimental set up. This may have influence on Marongoni drying process as the flow of DI water and iso propyl alcohol (IPA) is supposed to be smooth over the wafers. 8. REFERNCES 18

1. M.R. Litchy, D.C. Grant and R. Schoeb, SPWCC Wet Process Conference, Effect of pump pulsation and particle loading on membrane filter retention. 13-15, Feb 2006. 2. Y. Stefani, Plastic pumps for semiconductors, World pumps, 38-41, Oct 2004. 3. M.R. Litchy and D.C. Grant, Effects of shear and cavitation on particle agglomeration during handling of CMP slurries containing silica, alumina and ceria particles, CTA pub#70 4. F.C. Chang, S. Tanawade and Rajiv Singh, Effects of stress-induced particle agglomeration on defectivity during CMP of low-k dielectrics, J. Electrochem. Soc. 156 (1), H39-H42, 2009. 5. F.C. Chang, S. Tanawade and Rajiv Singh, How pump induced particles affect low-k dielectrics, University of Florida, Technical report, Sep 2008. 6. M. Litchy, Technical paper, Comparison of four pump systems on the particle size distribution of Cabot EP-C6618 sully, Nov. 8, 2006 7. L. Bauck and R. Donis, Slurry pump affects on CMP, The 2 nd PacRim International Conference on Planarization CMP and its application Technology, COEX, Seoul, Korea November 17-19, 2005. 8. B. Wu, Technical paper, foaming effects of Levitronix s pump. Apr 11, 2003. 9. D.D. Chilcote, An evaluation of particles shedding from Levitronix BpS-3 pump during operation, CT associates Inc., Technical report, Aug 26, 2002 19