Δ q = ( ψ L) HDH (1) here, Δq is the additional heat transfer caused by the thermal bridge, Ψ and L are the linear thermal transmittance and length of

Solar Control in Traditional Architecture, Potentials for Passive Design in Hot and Arid Climate

ADVANCED ROOF COATINGS: MATERIALS AND THEIR APPLICATIONS

Thermal mass vs. thermal response factors: determining optimal geometrical properties and envelope assemblies of building materials

Outdoor Thermal Comfort and Local Climate Change: Exploring Connections

The impact of urban geometry on the radiant environment in outdoor spaces

Variability of Reference Evapotranspiration Across Nebraska

Computational Modelling of the Impact of Solar Irradiance on Chemical Degradation of Painted Wall Hangings in an Historic Interior

Determination of Optimum Fixed and Adjustable Tilt Angles for Solar Collectors by Using Typical Meteorological Year data for Turkey

Exercise 6. Solar Panel Orientation EXERCISE OBJECTIVE DISCUSSION OUTLINE. Introduction to the importance of solar panel orientation DISCUSSION

Double-Skin Facade in Low-Latitude: Study on the Absorptance, Reflectance, and Transmittance of Direct Solar Radiation

Chapter 2 Experimental Studies on Hygrothermal Behaviour of ETICS

ON-LINE SOLAR RADIATION MONITORING SYSTEM, IN CLUJ NAPOCA, ROMANIA

Hourly Solar Radiation Analysis of Buildings within 48 Facings in FuZhou, China

R E V I E W R E P O R T

ATMOSPHERIC ENERGY and GLOBAL TEMPERATURES. Physical Geography (Geog. 300) Prof. Hugh Howard American River College

COMPARISON OF GUNN BELLANI RADIOMETER DATA WITH GLOBAL SOLAR RADIATION SENSOR (PYRANOMETER CM6B) Author. Mungai Peter N.

Winter Thermal Comfort in 19 th Century Traditional Buildings of the Town of Florina, in North-Western Greece

Page 1. Name:

Group Research Projects

Orientation of Building

Nonlinear atmospheric response to Arctic sea-ice loss under different sea ice scenarios

The energy performance of an airflow window

PRACTICAL TEST: THE SUN, A UNIQUE ENERGY SOURCE FOR THE SOLAR SYSTEM

AT350 EXAM #1 September 23, 2003

Lecture 4 Air Temperature. Measuring Temperature. Measuring Temperature. Surface & Air Temperature. Environmental Contrasts 3/27/2012

Section 1: Overhang. Sizing an Overhang

Comparison of meteorological data from different sources for Bishkek city, Kyrgyzstan

Thermal Comfort; Operative Temperature in the Sun

Winter Night. Thermos 6mm Outdoors # #

THERMAL DYNAMIC BEHAVIOR OF SINGLE COMPONENT: EXPERIMENTAL ANALYSIS AND NUMERICAL MODELING

Preliminary Experimental Study on Heat Transfer Characteristics of Wall with Automatic Adjustment of Heat Transfer Coefficient

QIRT th International Conference on Quantitative InfraRed Thermography

TREES Training for Renovated Energy Efficient Social housing

EFFECT OF INTERNAL LONG WAVE RADIATION AND CONVECTION ON FENESTRATION SIMULATION

IBHS Roof Aging Program Data and Condition Summary for 2015

Solar Radiation Measurements and Model Calculations at Inclined Surfaces

Urban heat island effects over Torino

Response function method

Vertical Illuminance Measurement for Clear Skies in Tehran

URBAN HEAT ISLAND IN SEOUL

TRANSPARENT INNOVATIVE MATERIALS: ENERGETIC AND LIGHTING PERFORMANCES EVALUATION

Why the Earth has seasons. Why the Earth has seasons 1/20/11

Experimental and Theoretical Study on the Optimal Tilt Angle of Photovoltaic Panels

Envelope wall/roof thermal performance parameters for non air-conditioned buildings

The Electrodynamics of a Pair of PV Modules with Connected Building Resistance

Radiation Effects On Exterior Surfaces

Stochastic modeling of Extinction coefficients for solar power applications

Field Experiment on the Effects of a Nearby Asphalt Road on Temperature Measurement

OASIS WIRELESS WEATHER STATION

Institut national des sciences appliquées de Strasbourg GENIE CLIMATIQUE ET ENERGETIQUE APPENDICES

Solar spectral irradiance measurements relevant to photovoltaic applications

THE AVERAGE TOTAL DAYLIGHT FACTOR

teachers and students(gong 2005). For example: square, foot path, lawn area, lakeside area, building of the around. The quality of campus semi-open sp

Project 2. Introduction: 10/23/2016. Josh Rodriguez and Becca Behrens

Diurnal Radiative Cooling of Spaces in Mediterranean Climate

Website Phone Mobile OVERVIEW Davis Vantage Pro2 Weather Station

Analysis of meteorological measurements made over three rainy seasons in Sinazongwe District, Zambia.

Long term weather trends in Phaltan, Maharashtra. French intern at NARI, student from Ecole Centrale de Lyon, Ecully 69130, France.

EXPERIMENTAL MEASUREMENTS ON TEMPERATURE GRADIENTS IN CONCRETE BOX-GIRDER BRIDGE UNDER ENVIRONMENTAL LOADINGS

PHOTOVOLTAIC SOLAR ENERGY TRAINER DL SOLAR-D1 Manual

Heating of Rainfall Runoff on Residential and Commercial Roofs

Uncertainty and sensitivity analysis in building simulation:

SEASONAL AND DAILY TEMPERATURES

CAE 463/524 Building Enclosure Design Fall 2012

FUNDAMENTAL SCIENCES AND APPLICATIONS

38 B Our Environment. Ederlinda Viñuales Gavín Marco Nicolini. Sun Exposition &

1.4j interpret simple shadow stick data to determine local noon and observer s longitude

Temperature Changes OBJECTIVES PREPARATION SCHEDULE MATERIALS. The students. For each student. For each team of two. For the class

INVESTIGATIONS ON SOLAR THERMAL PROCESS HEAT INTEGRATION WITH PARABOLIC TROUGH COLLECTORS

CAE 331/513 Building Science Fall 2016

Evaluation of monthly total global and diffuse solar radiation in Ibi, Taraba state, Nigeria

Hygrothermal Performance of Ventilated Cold Roofs an Experimental Study

Which graph best shows the relationship between intensity of insolation and position on the Earth's surface? A) B) C) D)

Bell Work. What are the four factors that affect climate for an area? Choose one of the four factors and explain how it impacts climate?

Lesson: Why We Have Seasons

5B.1 DEVELOPING A REFERENCE CROP EVAPOTRANSPIRATION CLIMATOLOGY FOR THE SOUTHEASTERN UNITED STATES USING THE FAO PENMAN-MONTEITH ESTIMATION TECHNIQUE

STUDY OF A PASSIVE SOLAR WINTER HEATING SYSTEM BASED ON TROMBE WALL

University of New Mexico Mechanical Engineering Fall 2012 PhD qualifying examination Heat Transfer

Ventilative Cooling issues in Mediterranean regions (The Spanish case) Servando Álvarez, José L. Molina University of Seville (Spain)

HIGHLY INSULATING AEROGEL GLAZING

Solar radiation data validation

Comparison between air temperature measured inside a conventional large wood shelter and by means of present day screens

A SIMPLE MODEL FOR THE DYNAMIC COMPUTATION OF BUILDING HEATING AND COOLING DEMAND. Kai Sirén AALTO UNIVERSITY

Chapter 2 Inputs for Hygrothermal Simulation Tools

DYNAMIC DAYLIGHT AND SOLAR CONTROL IN TROPICAL CLIMATE

A Typical Meteorological Year for Energy Simulations in Hamilton, New Zealand

My Community vs. Nunavut Weather and Climate

Worksheet: The Climate in Numbers and Graphs

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

OFFICE DE CONSULTATION PUBLIQUE DE MONTRÉAL

THERMAL ACTIONS. Milan Holický and Jana Marková. Czech Technical University in Prague, Czech Republic

Daylighting Buildings Nexus November 12, 2009

AR/IA 241 LN 231 Lecture 4: Fundamental of Energy

Vermont Soil Climate Analysis Network (SCAN) sites at Lye Brook and Mount Mansfield

Effect of moisture transfer on heat energy storage in simple layer walls

The influence of solar radiation on the distribution of temperatures in historic masonry

Different Materials with High Thermal Mass and its Influence on a Buildings Heat Loss An Analysis based on the Theory of Dynamic Thermal Networks

Transcription:

PLEA2013-29th Conference, Sustainable Architecture for a Renewable Future, Munich, Germany 10-12 September 2013 Testing the performance of a green wall system on an experimental building in the summer CRISTINA NORI1, FRANCESCA OLIVIERI1, ROBERTA COCCI GRIFONI2, CÉSAR BEDOYA1 1 Department of Construction and Technology in Architecture, Escuela Técnica Superior de Arquitectura, Universidad Politécnica de Madrid, Av. de Juan de Herrera 4, 28040 Madrid, Spain 2 School of Architecture and Design, Camerino University, Ascoli Piceno, Italy ABSTRACT: It is known that a green wall brings some advantages to a building. It constitutes a barrier against solar radiation, thus decreasing and delaying the incoming heat flux. The aim of this study is to quantify such advantages through analytical comparison between two facades, a vegetal facade and a conventional facade. Both were highly insulated (U-value = 0.3 W/m2K) and installed facing south on the same building in the central territory of Spain. In order to compare their thermal trend, a series of sensors were used to register superficial and indoor air temperature. The work was carried out between 17th August 2012 and 1st October 2012, with a temperature range of 12 C-36 C and a maximum horizontal radiation of 1020 W/m2. Results show that the indoor temperature of the green wall module was lower than the other. Besides, comparing superficial outdoor and indoor temperatures of the two walls to outdoor air temperatures, it was noticed that, due to the shading plants, the green wall superficial temperature was 5 C lower on the facade, while the bare wall temperature was 15 C higher. The living wall module temperature was 1.6 C lower than the outdoor, while the values of the conventional one were similar to the outdoor air temperature. Keywords: Green wall; Experimental building; Comparative analysis; Summer performance. INTRODUCTION Green systems carry out important functions in environmental control. The green is a living system and it is able to absorb the incident solar radiation on the leaves, assimilating one part for the photosynthesis and dissipating the other in the atmosphere. For this reason, they are also called living walls. In the summer the leaves prevent rear overheating, thanks to the double effect of shading and evapotranspirating. [1]. In winter the green layer contributes to the insulation of the enclosure [2]. There are different types of green walls, made of plants that directly stick to the wall, as the ivy, or to a vertical support made of nets and stainless steel cables. Another type of green system uses a panel whose interior is divided into cells where the substrate is placed. The panels are modular and they are anchored to the wall through a light support structure, covering a whole facade [3]. The aim of the study is both to quantify thermal advantages brought by a vegetal facade system inserted in a highly isolated enclosure in comparison to a conventional system and to check if the latter has also these kinds of advantages. bare wall green wall Figure 1. Experimental building plan DESCRIPTION Two kinds of facade were analyzed, a vegetal one (V.F.) and a conventional one (C.F.). They were installed facing south on an experimental building in Colmenar Viejo (Spain), with latitude 40 39'15.94"N and longitude 3 45'24.83"O. This town has a Mediterraneancontinental climate. The average temperature in July is 23.6 C with relative average daily solar radiation of 7.6 kwh/m2. The average temperature in January is 4.7 C with relative average daily solar radiation of 2.2 kwh/m2 [4]. The south facade was divided into four modules. We analyzed the two middle modules. Each of them was 1.8 m wide and 2.4 high and they had an adiabatic space of about 3 m2 at the back (Fig. 1). Both facades had 8-10 cm a thermal insulation. Thermal

transmittance of the bare wall was 0.315 W/m 2 K and that of the green wall was 0.12 W/m 2 K. The green facade was made of 600mm x 600 mm panels with felt layers containing nutrients for the plants. There was also an irrigation system that conveyed exceeding water to the panels base (Fig.2), while the conventional wall only had a white polyethylene sheet on the external surface (Fig. 3). had been positioned, the indoor temperature difference between the two facades was constant (2-4 C) depending on the weather (cloudy or sunny), while without the green, indoor temperatures were almost the same at night. Table 1. Sunny days 4/09 5/09 6/09 Max hor. radiation [W/m 2 K] 882.4 868.2 856.1 Max ver. radiation [W/m 2 K] 690.8 683.4 692.0 Max Humidity [%] 47.9 52.3 60.1 Max ext temperature [ C] 26.4 28.0 30.7 Max o. s. s. VF [ C] 23 23.3 22.1 Max o. s. s. CF [ C] 43.5 44.8 46.7 Max i. s. VF [ C] 25 25.5 26.5 Figure 2. Vegetal Facade System section Max i. s. CF [ C] 26.1 26.9 27.9 1. Boards of laminated plaster s= 15 mm 2. Insulating s= 80 mm 3. Impermeable sheet s= 1.8 mm 4. Cement plates s= 12.5 mm 5. Brackets 6. Modules prevegetados METODOLOGY Data were collected from 15th July 2012 to 30th September 2012 thanks to a series of resistance thermometers, but the vegetal wall was positioned on 17th August 2012. Four of the eighteen used sensors were selected in this study, which were those used to measure indoor temperature, indoor superficial temperature, indoor layers temperature and outdoor superficial temperature [5]. The system recorded the temperature every 15 minutes. The weather station was 100 m far from the experimental building and recorded weather data such as air temperature, relative humidity, solar radiation, both vertically and horizontally every 15 minutes. The two facades could be compared before and after positioning the vegetal layer (since it was positioned later), in order to quantify the benefits that such a wall could generate in the inside. Both with high and low radiation, the temperature of the conventional facade was always higher than the other, both with or without the green, but in a different way: once the vegetal facade Figure 3. Conventional Facade System section 1. Plasterboard s= 10 mm 2. ½ foot of perforated brick s= 115 mm 3. Insulating s= 100 mm 4. Metal plates with polyethylene core s= 4 mm DISCUSSION To understand if and how outdoor environmental conditions can affect the two systems, we decided to carry out an analysis on a sunny day and one on a

cloudy day, choosing 3 consecutive days that would be representative of these two conditions and characterized by average values of solar radiation and air temperature [6]. Starting from these assumptions we carried out some analysis from different points of view: -comparison between temperature difference of the two facades and outdoor weather conditions; -comparison between outdoor superficial temperature of the two systems and outdoor conditions; -comparison between indoor temperature of each facade and corresponding outdoor superficial temperature. Outdoor conditions and outdoor superficial temperature difference between the two facades were analyzed: on September 6 th (sunny day), where the conventional wall had the highest temperature, the biggest temperature difference was 27.7 C. In fact, radiation (measured on the vertical plane), outdoor air temperature and relative humidity were the highest of the three sunny days (Table 1). This difference varied a lot throughout the day. We noticed a strong oscillation between day and night. Getting gradually closer to the interior, sensors detected a significantly diminished difference compared to external surface temperatures. In the indoor space the maximum difference was, in fact, 2.6 C. Among the cloudy days, the biggest temperature difference on the external surface between the two facades was recorded on September 29 th, with a value of 20.8 C (Table 2); in the inside space the maximum recorded difference was 1.7 C. Max ver. radiation [W/m 2 K]: Maximum vertical solar radiation Max ext temperature [ C]: Maximum external air temperature Max o. s. s. VF [ C]: Maximum temperature outdoor superficial sensor Vegetal Facade Max o. s. s. CF [ C]: Maximum outdoor superficial sensor temperature Conventional Facade Max i. s. VF [ C]: Maximum indoor sensor temperature Vegetal Facade Max i. s. CF [ C]: Maximum indoor sensor temperature Conventional Facade Another analysis concerning the type of relationship between outdoor superficial temperature of the two facades and outdoor environmental conditions was carried out to understand how they could affect both the superficial and the indoor temperature. On September 5 th (sunny day) the green wall recorded a maximum temperature of 23.3 C. The bare wall recorded 44.8 C on September 6 th, when there were extreme outdoor conditions (Fig. 4). As for the cloudy day, both the green and the reference facade recorded a maximum external surface temperature on September 29 th : 16.3 C the first, 35.4 C the second. (Fig. 5). Table 2. Cloudy days 28/09 29/09 30/09 Max hor. radiation [W/m 2 K] 140.8 394.9 794.4 Max ver. radiation [W/m 2 K] 140.8 401.0 819.5 Max humidity [%] 95.0 94.4 89.4 Max ext temperature [ C] 16.1 18.0 19.3 Max o. s. s. VF [ C] 15.1 16.3 17.3 Max o. s. s. CF [ C] 18.2 35.4 38.2 Max i. s. VF [ C] Max i. s. CF [ C] 16 17.4 16.5 17.5 18.3 19.4 Figure 4. Outdoor superficial temperature of the two systems on sunny days Max hor. radiation [W/m 2 K]: Maximum horizontal solar radiation

Figure 5. Outdoor superficial temperature of the two systems on cloudy days Figure 6. Outdoor superficial temperature and indoor temperature of the two systems on sunny days In both cases, on the sunny day and on the cloudy day, the vegetal facade temperature was higher than the conventional one in the early hours of the morning and at night, that is when air temperature decreases and there is no solar radiation. The outdoor superficial temperature trend of the conventional facade follows the solar radiation trend. This also means that there is a strong oscillation between night and day. The solar radiation effects on the vegetal facade appeared after some hours, when the maximum outdoor superficial temperature was recorded. The trend was, nevertheless, more stable, with no big variations, unlike the other system. Finally, we examined outdoor superficial temperature trends and the indoor temperature of both facades. First of all, we noticed that both on the sunny and on the cloudy day the bare wall temperature was always higher than that of the green wall. In the first case, the temperature was 1.7 C higher (on average); in the second case it was 1.3 C higher. Beside this, we noticed that this difference between the two walls remained the same during the low solar radiation period; a small difference increase was detected, instead, between the two systems on high solar radiation days in the early hours of the morning. In both cases (high and low solar radiation) (Fig. 6-7), the outdoor temperature of the bare wall, as before mentioned, clearly followed the solar radiation trend. The green wall was less affected by the radiation; on the contrary, the vegetation clearly affected the temperature of the air inside the two modules, where the maximum difference between the two systems was 2.6 C and the smallest was 0.4 C on the sunny day; on the cloudy day the biggest difference was 1.7 C and the smallest was 0.7 C.

Therefore, on the basis of these data, the use of vegetal facades seems recommendable in case of climates characterized by many hours of solar radiation, confirming that their use brings thermal benefits compared to a conventional wall. Figure 7. Outdoor superficial temperature and indoor temperature of the two systems on cloudy days CONCLUSIONS The aim of this study is to quantify the thermal trend of a green wall in the summer compared to a normal wall and verify if very thick thermal insulation nullifies the effect of the vegetation inside. From the studies that we carried out, comparing different variables, the main conclusions are the following: - The external climatic conditions strongly affect the temperature of the facades, but in a different way for the green system. We noticed, in fact, that the external temperature difference, where the temperature of the conventional facade is higher, increases when solar radiation and air temperature increase, while inside the difference values are significantly lower and maximum values do not correspond to the most extreme outside conditions. It was found also that the temperature of the green facade is higher at night hours, when there is no radiation, because the bare wall is characterized by a strong thermal daily oscillation, while the vegetal facade maintains a more constant trend throughout the day; -The outdoor superficial temperature is affected by the solar radiation, especially for what concerns the conventional wall. In fact, with the same conditions of solar radiation we have a very different maximum temperature on the surface: 46.7 C on the bare wall and 22.1 C on the green wall; -The results show that, despite the high insulation thickness, within the modules temperature, difference varies between 1.7 C and 1.3 C, recording the highest values on sunny days. This shows that vegetation effect is stronger when external conditions are extreme, with high values of radiation and air temperature. REFERENCES 1. Mazzali, U., et al., (2013). Experimental investigation on the energy performance of Living Walls in a temperate climate. Building and Environment. 2. Valesan, M., et al., Residential buildings with green walls: Advantages, disadvantages and symbols evoked by the use of Ficus pumila and Parthenocissustricuspidata species, in PLEA 2011-27 th Conference on Passive and Low Energy Architecture. 2011: Louvain-la-Neuve, Belgium. 3. IDAE (2010). Guía técnica: Condiciones climáticas exteriores de proyecto: p. 75. 4. Siragusa, L. Sistemi di inverdimento verticale per l architettura urbana: p. 4-10. 5. Eumorfopoulo, E. A. and Kontoleon, K.J., (2009). Experimental approach to the contribution of plant-covered walls to the thermal behaviour of building envelopes. Building and Environment. 6. Wong, N. H., et al., (2010). Thermal evaluation of vertical greenery systems for building walls. Building and Environment.