Heat transfer rate of a closed-loop oscillating heat pipe with check valves using silver nanofluid as working fluid

Similar documents
The top heat mode of closed loop oscillating heat pipe with check valves at the top heat mode (THMCLOHP/CV): a thermodynamic study

Heat Transfer Correlations for Small Closed End Heat Pipe with Special Vapor Chamber

Numerical Simulation on Flow and Heat Transfer in Oscillating Heat Pipes

NUMERICAL SIMULATION ON FLOW AND HEAT TRANSFER IN OSCILLATING HEAT PIPES

Effect of Nanofluid Concentration on the Performance of Circular Heat Pipe

USING MULTI-WALL CARBON NANOTUBE (MWCNT) BASED NANOFLUID IN THE HEAT PIPE TO GET BETTER THERMAL PERFORMANCE *

EXPERIMENTAL INVESTIGATION OF IN SITU PRESSURE MEASUREMENT OF AN OSCILLATING HEAT PIPE

LIQUID FILM THICKNESS OF OSCILLATING FLOW IN A MICRO TUBE

Comparison of Heat Transfer rate of closed loop micro pulsating heat pipes having different number of turns

Effect of particle volume concentration on thermo physical properties of Silicon Carbide Water based Nanofluid

Comparative study on heat transfer characteristics of nanofluidic thermosyphon and grooved heat pipe

Heat Transfer Enhancement in Fe3O4-water Nanofluid through a Finned Tube Counter Flow Heat Exchanger

Performance Analysis of Pulsating Heat Pipes Using Various Fluids

IHTC DRAFT MEASUREMENT OF LIQUID FILM THICKNESS IN MICRO TUBE ANNULAR FLOW

GRAVITY EFFECT ON THE DISTRIBUTION OF REFRIGERANT FLOW IN A MULTI-CIRCUITED CONDENSER

Mathematical Modelling for Refrigerant Flow in Diabatic Capillary Tube

International Journal of Advancements in Research & Technology, Volume 3, Issue 11, November ISSN

SEM-2017(03HI MECHANICAL ENGINEERING. Paper II. Please read each of the following instructions carefully before attempting questions.

Measurement of temperature-dependent viscosity and thermal conductivity of alumina and titania thermal oil nanofluids

Boiling Heat Transfer and Pressure Drop of R1234ze(E) inside a Small-Diameter 2.5 mm Microfin Tube

Minhhung Doan, Thanhtrung Dang

Uncertainty Analysis of Flat Plate Oscillating Heat Pipe with different Working Fluids

A Study On The Heat Transfer of Nanofluids in Pipes

FLOW BOILING HEAT-TRANSFER IN PLATE MICRO- CHANNEL HEAT SINK

HEAT TRANSFER CAPABILITY OF A THERMOSYPHON HEAT TRANSPORT DEVICE WITH EXPERIMENTAL AND CFD STUDIES

Analysis of Frictional Pressure Drop based on Flow Regimes of Oil-water Flow in Pipeline

Oscillating Heat Pipe Performance with Evaporator Section Modifications

Effect of flow velocity on the process of air-steam condensation in a vertical tube condenser

Received 31 December 2015; revised 16 October 2016; accepted 21 November 2016; available online 10 June 2017

Heat Transfer Performance in Double-Pass Flat-Plate Heat Exchangers with External Recycle

Film condensation on horizontal tube with wall suction effects

Vijayawada, AP. Fig Two-Step Mixing Procedure Diagram of Nano- Fluid

Theoretical Design and Analysis of Gravity Assisted Heat Pipes

NUMERICAL INVESTIGATION OF THERMOCAPILLARY INDUCED MOTION OF A LIQUID SLUG IN A CAPILLARY TUBE

THE EXPERIMENTAL STUDY OF THE EFFECT OF ADDING HIGH-MOLECULAR POLYMERS ON HEAT TRANSFER CHARACTERISTICS OF NANOFLUIDS

Numerical Analysis of Fe 3 O 4 Nanofluid Flow in a Double Pipe U-Bend Heat Exchanger

THE EFFECT OF LIQUID FILM EVAPORATION ON FLOW BOILING HEAT TRANSFER IN A MICRO TUBE

EXPERIMENTAL STUDIES OF THERMAL CONDUCTIVITY, VISCOSITY AND STABILITY OF ETHYLENE GLYCOL NANOFLUIDS

Multiphase Flow and Heat Transfer

The Research of Heat Transfer Area for 55/19 Steam Generator

Correlation to predict heat transfer of an oscillating loop heat pipe consisting of three interconnected columns

Steady and Transient Heat Transfer Characteristics of Flat Micro Heatpipe

Heat Transfer Enhancement Using a Rotating Twisted Tape Insert

Chapter 10: Boiling and Condensation 1. Based on lecture by Yoav Peles, Mech. Aero. Nuc. Eng., RPI.

Thermo-Fluid Performance of a Vapor- Chamber Finned Heat Sink

first law of ThermodyNamics

THERMAL CHARACTERISTICS OF GROOVED HEAT PIPE WITH HYBRID NANOFLUIDS

Development of a one-dimensional boiling model: Part I A two-phase flow pattern map for a heavy hydrocarbon feedstock

How to chose cooling fluid in finned tubes heat exchanger

Research Article Heat Transfer of Nanofluid in a Double Pipe Heat Exchanger

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

Comparative Study of Two Phase Closed Thermosyphon with Different Fluids and Fill Volume Ratio

Heat Transfer with Phase Change

Introduction to Heat and Mass Transfer

A VAPOR-PRESSURE-DRIVEN HEAT PIPE FOR SIDEWARD LONG-DISTANCE HEAT TRANSPORT

PUMP SYSTEM ANALYSIS AND SIZING. BY JACQUES CHAURETTE p. eng.

An Experimental Study On Condensation Of R134a In A Multi-Port Extruded Tube

Piping Systems and Flow Analysis (Chapter 3)

Chapter 11: Heat Exchangers. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Measurement of the performances of a transparent closed loop two-phase thermosyphon

Experimental Study on Liquid Film Thickness of Annular Flow in Microchannels

In this project a comparison of heat transfer and

Phone: , For Educational Use. SOFTbank E-Book Center, Tehran. Fundamentals of Heat Transfer. René Reyes Mazzoco

Australian Journal of Basic and Applied Sciences. Numerical Investigation of Flow Boiling in Double-Layer Microchannel Heat Sink

ABSTRACT I. INTRODUCTION II. BACKGROUND OF STUDY

Stratified Flow Condensation of CO 2 in a Tube at Low Temperatures Pei-hua Li 1, a, Joe Deans 2,b and Stuart Norris 3,c

Droplet Evaporation Behavior of Kerosene/Nano Aluminum Fuels at High Pressure Environment

Experimental Study of Energy Efficiency of a Single Microtube

Analysis of Heat Transfer Enhancement in Spiral Plate Heat Exchanger

THEORETICAL AND EXPERIMENTAL INVESTIGATION OF OSCILLATING HEAT PIPES

GENERAL PHYSICS (3) LABORATORY PHYS 203 LAB STUDENT MANUAL

Coolant. Circuits Chip

T718. c Dr. Md. Zahurul Haq (BUET) HX: Energy Balance and LMTD ME 307 (2018) 2/ 21 T793

EXPERIMENTAL ANALYSIS OF R-134a FLOW CONDENSATION IN A SMOOTH TUBE

An insight into thermo-hydrodynamic coupling in closed loop pulsating heat pipes

Principles of Food and Bioprocess Engineering (FS 231) Problems on Heat Transfer

Visualization the Distribution of Air-Water Mixtures Flow in Two Outlet Distributor

Available online at ScienceDirect. Physics Procedia 67 (2015 ) Superfluid helium heat pipe. P.

a. Key Laboratory of Efficient Utilization of Low and Medium Grade Energy, MOE, Tianjin University, Tianjin , China

Heat Transfer Convection

International Journal of Heat and Mass Transfer

INVESTIGATION OF VAPOR GENERATION INTO CAPILLARY STRUCTURES OF MINIATURE LOOP HEAT PIPES

NANOFLUIDS. Abstract INTRODUCTION

FE Fluids Review March 23, 2012 Steve Burian (Civil & Environmental Engineering)

Comparison of the Heat Transfer Efficiency of Nanofluids

THE CHARACTERISTICS OF BRAZED PLATE HEAT EXCHANGERS WITH DIFFERENT CHEVRON ANGLES

Experimental Investigation of plate heat exchanger using Nanofluids

Plant Design LECTURE 8: REBOILER CIRCUIT DESIGN. Daniel R. Lewin Department of Chemical Engineering Technion, Haifa, Israel

Condensation of refrigerant R407C in multiport minichannel section

Experimental investigation on up-flow boiling of R1234yf in aluminum multi-port extruded tubes

EFFECT OF LIQUID REYNOLDS NUMBER ON PRESSURE DROP OF EVAPORATIVE R-290 IN 500µm CIRCULAR TUBE

A Novel Model Considered Mass and Energy Conservation for Both Liquid and Vapor in Adsorption Refrigeration System.

Journal of NUCLEAR SCIENCE and TECHNOLOGY, Vol. 41, No. 7, p (July 2004)

HEAT TRANSFER ENHANCEMENT BY USING NANOFLUID JET IMPINGEMENT

Proceedings of 12th International Heat Pipe Conference, pp , Moscow, Russia, 2002.

How can we use Fundamental Heat Transfer to understand real devices like heat exchangers?

&/26('$1'23(1/22338/6$7,1*+($73,3(6

International Journal of Research in Advent Technology, Vol.6, No.11, November 2018 E-ISSN: Available online at

Heat transfer coefficient of near boiling single phase flow with propane in horizontal circular micro channel

A NUMERICAL APPROACH FOR ESTIMATING THE ENTROPY GENERATION IN FLAT HEAT PIPES

Transcription:

Journal of Mechanical Science and Technology 23 (2009) 1576~1582 Journal of Mechanical Science and Technology www.springerlink.com/content/1738-494x DOI 10.1007/s12206-009-0424-2 Heat transfer rate of a closed-loop oscillating heat pipe with check valves using silver nanofluid as working fluid S. Wannapakhe 1, S. Rittidech 1,*, B. Bubphachot 1 and O. Watanabe 2 1 Faculty of Engineering, Mahasarakham University, Khamriang, Kantarawichai, Mahasarakham, 44150, Thailand 2 Faculty of Engineering Mechanics and Energy, University of Tsukuba, Tsukuba, Ibaraki, 3058573 Japan (Manuscript Received September 1, 2008; Revised January 7, 2009; Accepted March 10, 2009) -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Abstract This research investigated the effect of aspect ratios (evaporator length to inner diameter of capillary tube), inclination angles, and concentrations of silver nanofluid on the heat transfer rate of a closed-loop oscillating heat pipe with check valves (CLOHP/CV). The CLOHP/CV was made from copper tubing with an internal diameter of 2 mm. Two check valves were inserted into the tube. The tube had 40 meandering turns. The length of the evaporator was 50, 100, and 150 mm. The lengths of the evaporator, adiabatic, and condenser section were equal. The concentration of silver nanofluid was 0.25, 0.5, 0.75, and 1 %w/v, and the operating temperature was 40, 50, and, 60 o C. It was found that the heat transfer rate of the CLOHP/CV using silver nanofluid as a working fluid was better than that the heat transfer rate when pure water is used because the silver nanofluid increases the heat flux by more than 10%. Keywords: Nanofluid; Oscillating heat pipe; Check valve; Heat transfer -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 1. Introduction A heat pipe is a type of heat exchanger that is very easy and straightforward to use. Heat pipes used for heat transfer have been improved over time. Over the years, researchers have continuously explored new methods of heat transfer enhancement. The results of employing different cooling liquids proved to be one effective way of improving the system s overall performance. Nanofluid is a new working fluid for heat exchangers which does not pollute because it uses water as a base fluid. Nanofluids are engineered by suspending ultra-fine metallic or nonmetallic nanometer dimension particles in base fluids (water, oil, and ethylene glycol). In 2006, Shung et al. [1] studied the effect of silver nanoparticle size. Using varying concentrations of silver nanofluids in a heat pipe led to an increase in This paper was recommended for publication in revised form by Associate Editor Man Yeong Ha * Corresponding author. Tel.: +66 4 375 4316, Fax.: +66 4 375 4316 E-mail address: s_rittidej@hotmail.com KSME & Springer 2009 the heat pipe wall temperature. In 2007, Yu Hsing Lin et al. [2] studied the effect of silver nanofluid on a pulsating heat pipe s thermal performance using a copper tube with internal diameters of 2.4 and 3 mm. The fill ratio was 60% while the heating power was 85W. The average temperature difference of the evaporator and the condenser was compared with that of pure water, which was less than 7.79 o C. The thermal resistance was less than 0.092 o C/W. It proved that a nanofluid was suitable for application in a heat pipe. A closed-loop oscillating heat pipe with check valves (CLOHP/CV) was improved from the convenience heat pipe. Advantages of the CLOHP/CV include simplicity of construction, as it uses just a single tube, no wick structure, high thermal performance, capability of operation in any position, and operational flexibility. The heat flux of CLOHP/CV was found to be better than those of the closed-loop oscillating heat pipe (CLOHP) and the closed-end oscillating heat pipe (CEOHP) by (Pipatpaiboon et al. [3]). Therefore, CLOHP/CV and silver nanofluid were

S. Wannapakhe et al. / Journal of Mechanical Science and Technology 23 (2009) 1576~1582 1577 selected for use in this study. 2. Experimental setup and procedure 2.1 Nanofluid preparation Nanofluid is produced by metal or metal oxide nanoparticles suspended in base fluids such as oil or water. It involves many methods such as changing the ph value of the suspension, using surfactant activators, and using ultrasonic vibration. The nanoparticles suspended in base fluids are stable for a long time. For this research, nanofluid was prepared by a sonicator for five hours. The sonicator had a bath type, operating frequency, and power source of 43 khz, AC100, and 120V/AC220~240V 50/60 Hz, respectively. Nanoparticles were prepared by SIGMA- ALDRICH, Inc., USA. The silver nanopowder used in this study has a particle size of <100 nm, 99.5% (metals basis). The silver nanoparticles were suspended into DI water with concentrations of 0.25, 0.5, 0.75, and 1 %w/v. Stability was up to 48 hours. Fig. 1 shows silver nanoparticles with DI water before and after using the crest ultrasonic sonicator. 2.2 Experimental Setup An important factor that has to be considered in building a CLOHP/CV is the design of the tube diameter. For this research, the maximum inner diameter of CLOHP/CV can be defined in Eq. (1) [4]. The structure of the check valves in this study (Fig. 2) consists of four sections: ball, case, conical valve seat, and ball stopper. The advantage of a check valve is that it controls the liquid slug flow in one direction. The ball, which is made to control flow direction, is inserted in the middle of all compounds. Fig. 3 shows the CLOHP/CV used in this study. The system was made of a copper capillary tube bent into 40 meandering turns and filled with water or 0.25, 0.5, 0.75, and 1 %w/v silver nanofluid at a filling ratio of 50% of the tube s volume total. It was made up of three sections (evaporator, adiabatic, and condenser section), with two check-valves set up along the CLOHP/CV in a position shown in Fig. 4. The evaporator, adiabatic, and condenser section lengths were 50, 100, and 150 mm, respectively. Fig. 2. Structure of the check-valve. d σ <, (1) ρ g max 2 l where d max is the maximum inner of the capillary tube (m), σ is surface tension of the fluid (N/m), ρ l is density of the fluid (kg/m 3 ), and g is acceleration of gravity (m/s 2 ). Fig. 3. CLOHP/CV. (a) (b) Fig. 1. Silver nanoparticles with DI water; (a) before using the crest ultrasonic sonicator, and (b) after using the crest ultrasonic sonicator. Fig. 4. The position of the check-valves on the oscillating heat pipe.

1578 S. Wannapakhe et al. / Journal of Mechanical Science and Technology 23 (2009) 1576~1582 2.3 Experimental procedure CLOHP/CV was set into a test rig and adjusted to an inclination angle set (0, 20, 40, 60, 80, and 90 degree from horizontal axis) for experimentation as shown in Fig. 5. Fig. 6 shows the experimental procedure of this study. A hot bath (TECHNE TE-10D with ±0.1 C accuracy) and a cold bath (EYELA CA -1111, volume 6.0 liters with an operating, temperature range of -20 C to 30 C and ±2 C accuracy) were filled with water. Afterwards, water in the hot bath was released into the evaporator section and water in the cold bath was released into the condenser section by controlling the flow rate at 0.5 liter/minute. The temperature in the adiabatic section was observed just as the temperature reached the operating temperature set at 40, 50, and 60 o C. The temperatures at every measuring point were then recorded by a data logger (Yokogawa DX200 with ±0.1 C accuracy). The test was repeated with varying parameters such as evaporator length, concentration of silver nanofluid, inclination angle, and operating temperature. Next, the heat transfer and the heat transfer rate of the CLOHP/CV at the condenser section were calculated using Eqs. 2 and 3, respectively. 3. Result and discussion The temperature change of the condenser section s inlet water and outlet water was measured to calculate the heat flux of CLOHP/CV. The heat transfer rate of CLOHP/CV at the condenser section can then be calculated by Eq. (2) as follows: Q = mc (T T ) P 2 1, (2) where m is the mass flow rate of fluid at the condenser part (kg/s), Cp is the specific heat at constant pressure (kg/kj K), and T 1 and T 2 are the temperatures at the inlet condenser part and the outlet condenser part, respectively. In this experiment, the heat flux was calculated using Eq. (3) below: Q q = πdoln C, (3) where Q is the heat transfer rate (W), D O is the outside diameter of the capillary tube (m), L C is the condenser length (m), and N is the number of meandering. Apart from determining heat flux, thermal conductivity of the nanofluid was also determined in order to estimate the increase in thermal conductivity. The thermal conductivity of solid-liquid mixtures was introduced by Wasp (1997) [5]. Therefore, in case of silver nanofluid, using Wasp s equation as Eq. (4) yields the following: keff kp + 2kf 2α(k f k p ) =. (4) k k + 2k α(k k ) f p f f p Fig. 5. Experimental setup. The volume fraction (α) of the particles is defined as V α p = V V f + p. (5) The experimental data of 120 data are also shown in this paper. Fig. 6. Diagram of the experimental procedure. 3.1 The effect of inclination angles on the heat transfer rate of CLOHP/CV In Fig. 7, the effect of inclination angles on the CLOHP/CV with an aspect ratio of 25, a heat transfer

S. Wannapakhe et al. / Journal of Mechanical Science and Technology 23 (2009) 1576~1582 1579 rate at 90 o, and water in all concentrations used as the working fluid was higher than other inclination angles. Furthermore, the heat transfer rate of the CLOHP/CV using silver nanofluid as the working fluid was higher than when water was used. Therefore, the best value of heat transfer rate was 8.88 kw/m 2 (aspect ratio (L e /D i ) of 25 and concentration of 0.5 %w/v at 90 o from the horizontal axis). In Fig. 8, results of the heat transfer rate were similar to the results of an aspect ratio of 25. The best heat transfer rate of an aspect ratio set at 50 was 4.13 kw/m 2 (inclination angle at 90 o and silver nanofluid at 0.5 %w/v as working fluid). In Fig. 9, the best heat transfer rate was 7.69 kw/m 2 (inclination angle of 90 o and silver nanofluid concentration of 0.5 %w/v as the working fluid). As the thermal conductivity of the base fluid increased, the suspension of nanoparticles increased the heat capacity of the fluid. Moreover, the inclination angle of the CLOHP/CV has an effect on the heat transfer rate because of a pressure difference ( P g ) brought about by the hydrostatic head of liquid being positive, negative, or zero. This depended on the fluid s density, acceleration from gravity force, tube length, and inclination angle of the CLOHP/CV to the horizontal axis. The pressure difference may be determined from Eq. (4): Fig. 7. Inclination angle of CLOHP/CV on the heat transfer rate at an aspect ratio of 25. P = ρ gl sinφ, (6) g l where ρ l is the liquid density (kg/m 3 ), g is the acceleration due to gravity (9.81 m/s 2 ), l is the heat pipe length (m), and φ is the angle between the heat pipe and the horizontal axis (φ is positive when the condenser is lower than the evaporator). 3.2 The effect of operating temperatures on the heat flux of CLOHP/CV As described in 3.1, the best inclination angle to heat flux was 90 o. Therefore, in this case, the CLOHP/CV was tested at an inclination angle of 90 o from the horizontal axis. The effects of operating temperatures on the heat flux of CLOHP/CV are shown in Figs. 10, 11, and 12. The heat flux increased when the operating temperature increased, especially when silver nanofluid was used as the working fluid. Moreover, using silver nanofluid yielded a higher heat flux compared to using water as the working fluid. The best heat flux was 13.19 kw/m 2 at an aspect ratio of 25, an operating temperature of 60 o C, and a silver nanofluid concentration of 0.5 %w/v. The Fig. 8. Inclination angle of CLOHP/CV on the heat transfer rate at an aspect ratio of 50. Fig. 9. Inclination angle of CLOHP/CV on the heat transfer rate at an aspect ratio of 75.

1580 S. Wannapakhe et al. / Journal of Mechanical Science and Technology 23 (2009) 1576~1582 Fig. 10. The operating temperature on the heat transfer rate of CLOHP/CV at an aspect ratio of 25. Fig. 11. The operating temperature on the heat transfer rate of CLOHP/CV at an aspect ratio of 50. Fig. 12. The operating temperature on the heat transfer rate of CLOHP/CV at an aspect ratio of 75. thermal conductivity of the base fluid was increased by the silver nanoparticles. The suspension of nanoparticles resulted in an increase of the surface area and the heat capacity of the base fluid. Moreover, the temperature affected the heat flux of the CLOHP/CV because boundary force decreased when the temperature increased. Moreover, the boiling form was changed with increased operating temperature. Meena et al. [6] mentioned the flow pattern; it was separated into four types: annular flow occurring at low temperature, low thermal conductivity, fluid, and high aspect ratio. The heat flux of the slug flow was better than the annular flow, the heat flux of the bubble flow was higher than the slug and annular flow, and the best heat flux was dispersed flow. It occurred at a high temperature and a low aspect ratio. With the same fluid, the flow pattern at the inner tube changed from annular flow to slug, bubble, or dispersed flow when the operating temperature was increased. In this study, water and water mixed with silver nanoparticles were used as the working fluids. The base fluid was the same working fluid as that used by Meena et al. Therefore, when the operating temperature increased, the flow pattern also changed. It can change from annular flow to slug flow or bubble flow. Moreover, the aspect ratio of 25 was the best of all aspect ratios in this study because it was found to be suitable for boiling. This is because the adiabatic length at an aspect ratio of 25 was shorter than that at aspect ratios of 50 and 75. Therefore, the vapor plug transferred heat with ease from the evaporator section to the condenser section because the distance between the evaporator section and the condenser section was small. The result of this study was improved and then compared with the result of Y.H. Lin et al. Yu Hsing Lin et al. [2]. It was found that the heat transfer was in the same direction as shown in Fig. 13. 3.3 The concentration of silver nanofluid on the heat flux of CLOHP/CV The result of this study demonstrated that with each concentration of silver nanofluid, the heat flux was different. Of these, the concentration of 0.5 %w/v was the best of all concentrations for the heat flux at all operating temperatures, all aspect ratios, and all inclination angles. In previous research [7], when the concentration of the nanofluid increased, the heat flux also increased. However, in this study the opposite occurred because a nanofluid was used in the CLOHP/CV. This is because the heat flux of

S. Wannapakhe et al. / Journal of Mechanical Science and Technology 23 (2009) 1576~1582 1581 It can be summarized that the best inclination for using CLOHP/CV was 90 o from the horizontal axis. The operating temperature had an effect on the heat flux of the CLOHP/CV, and the heat flux using silver nanofluids at all concentrations were higher than with water. As a result, the thermal conductivity of the base fluid was increased. The suspension of nanoparticles can increase the heat capacity of the fluid. Nevertheless, the concentration of silver nanofluid can be increased to some point for supporting the heat flux of the CLOHP/CV because the heat flux of CLOHP/CV depended on the limit of working fluid viscosity. In this study, the best concentration of silver nanofluid for use in CLOHP/CV was 0.5 %w/v. Acknowledgment Fig. 13. A comparison of the heat transfer rates of this study and those of Y.H. Lin et al. [7]. CLOHP/CV depended on the limit of the working fluid viscosity. The higher concentration will make the viscosity higher. The higher viscosity makes it difficult to produce bubbles, and the force of the friction causing obstruction of the liquid slug becomes larger. Therefore, the concentration of silver nanofluid can be increased to some point in order to support the heat flux of CLOHP/CV. Between the concentrations of silver nanofluid at 0.25 and 0.75 %w/v, sometimes the heat flux of the silver nanofluid with a concentration of 0.75 %w/v was higher than at a concentration of 0.25 %w/v. This is because the thermal conductivity of the base fluid was influenced by the fluid s heat transfer rather than the effect of viscosity. If the heat flux of silver nanofluid at a concentration of 0.25 %w/v was higher than that at a concentration of 0.75 %w/v, this was because viscosity was influenced by the heat transfer of the fluid rather than being brought about by the effect of thermal conductivity. 4. Conclusion We wish to acknowledge the financial support extended to Sakultala Wannapakhe and Sampan Rittidech of the Faculty of Engineering at Mahasarakham University by the Thailand Research Fund through the Royal Golden Jubilee Ph.D. Program (Grant No. PHD/0084/2549). We would also like to thank Dr. Bangorn Thaewnon-ng and Dr. Utai Sakhee, of the Faculty of Science at Mahasarakham University, both of whom earnestly supported this research. Nomenclature----------------------------------------------------------- C p : Specific heat capacity constant pressure (J/ kg. C) D : Diameter of the capillary tube (m) g : Acceleration due to gravity (9.81 m/s 2 ) l : Heat pipe length (m) L : Length (m) m : Mass per unit time (kg/s) N : Number of meandering Q : Heat transfer rate (W) q : Heat flux (kw/m 2 ) T : Temperature ( o C) T 1 : Inlet temperature at condenser section ( o C) T 2 : Outlet temperature at condenser section ( o C) V : Volume (m 3 ) Greek symbols φ : The angle between the heat pipe and the horizontal ( o ) ρ l : Liquid density (kg/m 3 ) α : Volume fraction Subscripts ad : Adiabatic section c : Condenser section e : Evaporator section eff : Effective f : Fluid I : Inner

1582 S. Wannapakhe et al. / Journal of Mechanical Science and Technology 23 (2009) 1576~1582 o p : Out side : Particle is currently a Ph.D. student in Energy Technology at Mahasarakham University, Thailand. References [1] W. K. Sung, C. W. Wei, H. T. Sheng and Y. Y. Shih, Experimental investigation of silver nano-fluid on heat pipe thermal performance, Applied Thermal Engineering, 26 (2006) 2377-2382. [2] H. L. Yu, W. K. Shung and L. C. Hui, Effect of silver nano-fluid on pulsating heat pipe thermal performance, Applied Thermal Engineering, 28 (2007). [3] N. Pipatpaiboon, S. Rittidech, P. Sukna and T. Suddee, Effect of Inclinations Angles and number of Check valves on Heat Transfer Characteristics of a Closed-Looped Oscillating Heat Pipe with Check Valves, Proc. of the first international seminar on heat pipes and heat-recovery systems, Malasia (2004) 83-86. [4] S. Maezawa, KY. Gi., A. Minamisawa and H. Akachi H, Thermal Performance of Capillary Tube Thermosyphon, Proc. of the ninth international heat-pipe conference, USA (1996) 791-795. [5] F. J. Wasp, Solid-Liquid Flow Slurry Pipeline Transportation, Trans. Tech. Pub., Berlin, (1977). [6] P. Meena, A study of internal flow phenomena of a closed-loop oscillating heat pipe with check valves (CLOHP/CV), Special study for study of doctor of philosophy in energy technology, Mahasarakham University, Thailand, (2005). [4] N. Pipatpaiboon, S. Rittidech, P. Sukna, and T. Suddee, Effect of Inclinations Angles and number of Check valves on Heat Transfer Characteristics of a Closed-Looped Oscillating Heat Pipe with Check Valves, Proc. of the first international seminar on heat pipes and heatrecovery systems, Malasia (2004) 83-86. [7] X. Yimin and L. Qiang, Heat transfer enhancement of nanofluids, International J. Heat and Fluid Flow, 21 (2000) 58-64. Sampan Rittidech received his Ph.D. degree in Mechanical Engineering from Chiang Mai University, Thailand, in 2002. Dr. Sampan Rittidech is currently an Associate Professor at the Faculty of Engineering at Mahasarakham University in Thailand. Dr. Sampan s research interests include heat transfer, heat pipe, and heat exchanger. Bopit Bubphachot received his Ph.D. degree in Engineering Mechanics and Energy from University of Tsukuba, Japan, in 2008. Dr. Bopit Bubphachot is currently an Lecturer at the Faculty of Engineering at Mahasarakham University in Thailand. Dr. Bopit s research interests include Metal Forming (Fine Blanking Process), FEM Simulation in Metal Forming Process and Fatigue and Creep- Fatigue strength for Perforated Plate. Osamu Watanabe received his Ph.D. degree in Engineering from University of Tokyo, Japan, in 1981. Dr. Osamu Watanabe is currently a Professor at Graduate School of Systems and Information Engineering at University of Tsukuba, Japan. Dr. Osamu s research interests include inelastic behavior, material strength in nuclear or thermal plants, code and standard for plant technology. Sakultala Wannapakhe received her B.Eng. degree in Mechanical Engineering (Manufacturing) from Mahasarakham University, Thailand, in 2005. She then received her M. Eng. degree in Mechanical Engineering from Mahasarakham University, Thailand, in 2007. Sakultala Wannapakhe