Constraints on Low-Mass WIMPs from PICASSO. Carsten B. Krauss University of Alberta for the PICASSO Collaboration IDM Chicago, July

Similar documents
PoS(idm2008)010. The PICASSO Dark Matter Search Project. A. Davour for the PICASSO collaboration Queen s University

The Picasso Experiment Plans and Results Carsten Krauss Queen s University

Spin dependent limits on WIMP-proton scattering cross-section from PICASSO. Sujeewa Kumaratunga for the PICASSO collaboration

Backgrounds in PICO. Eric Vázquez Jáuregui SNOLAB. AARM Meeting Fermilab; Batavia IL, USA; March 19, 2014

Dark Matter Search With The PICASSO Experiment

COUPP: Bubble Chambers for Dark Matter Detection

Bubble Chambers for Direct Dark Matter Searches in COUPP

? Simulation. of PICASSO detectors. Marie-Hélène Genest - Université de Montréal

Miguel Ardid Universitat Politècnica de València SUSY 2013

Toward a next-generation dark matter search with the PICO-40L bubble chamber. Scott Fallows TAUP2017 Laurentian University 24 July 2017

Dark Ma'er Search Results from PICO- 60 and PICO- 2L

Rare Event Searches and the Underground

Deep Underground Labs and the Search for Dark Matter

Outline. Dark Matter Physics at SNOLAB: And Future Prospects. Overview of SNOLAB DarkMatter Program. Status of Current Experiments

COUPP. Carbon and Fluorine Recoil Thresholds. Alan Robinson July 26, 2012 IDM 2012, Chicago, IL

COUPP500: a 500kg Bubble Chamber for Dark Matter Detection

Improved Spin Dependent Limits from the PICASSO Dark Matter Search Experiment

Measurement of 39 Ar in Underground Argon for Dark Matter Experiments

XENON100. Marc Schumann. Physik Institut, Universität Zürich. IDM 2010, Montpellier, July 26 th,

arxiv: v1 [astro-ph.im] 6 Dec 2010

Dark Matter Detection and the XENON Experiment. 1 Abstract. 2 Introduction

Distinguishing Dark Matter Candidates from Direct Detection Experiments

Technical Specifications and Requirements on Direct detection for Dark Matter Searches

Direct Detection in the next five years: Experimental challenges and Phonon Mediated Detectors

arxiv: v2 [physics.ins-det] 23 Sep 2008

Direct Search for Dark Matter

Simulations, backgrounds, and uncertainties in PICO-2L. Alan Robinson May 20, 2015 AARM, Rapid City South Dakota

Search for Inelastic Dark Matter with the CDMS experiment. Sebastian Arrenberg Universität Zürich Doktorierendenseminar 2010 Zürich,

Status of the ANAIS experiment at Canfranc

arxiv: v2 [hep-ex] 28 Mar 2012

Status of Dark Matter Detection Experiments

DarkSide new results and prospects

Search for Low Energy Events with CUORE-0 and CUORE

Latest Results on Direct Detection of Dark Matter WIMPs - CDMS & SuperCDMS

SIGN: A Pressurized Noble Gas Approach to WIMP Detection

Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

SuperCDMS SNOLAB: A G2 Dark Matter Search. Ben Loer, Fermilab Center for Particle Astrophysics On behalf of the SuperCDMS Collaboration

arxiv: v2 [physics.ins-det] 28 Jul 2010

SuperCDMS: Recent Results for low-mass WIMPS

arxiv:astro-ph/ v1 24 Jun 2004

DARK MATTER SEARCH AT BOULBY MINE

DARWIN: dark matter WIMP search with noble liquids

The EDELWEISS DM search Phase II to Phase III

Search for low-mass WIMPs with Spherical Detectors : NEWS-LSM and NEWS-SNO

A New and Improved Spin-Dependent Dark Matter Exclusion Limit Using the PICASSO Experiment

WIMP Dark Matter Search with XENON and DARWIN

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

PHY326/426:Lecture 11

Enectalí Figueroa-Feliciano

Results from 730 kg days of the CRESST-II Dark Matter Search

A survey of recent dark matter direct detection results

The Search for Dark Matter with the XENON Experiment

Latest results of EDELWEISS II

Kiseki Nakamura (Kyoto university)

The XENON1T experiment

Collaborazione DAMA & INR-Kiev. XCVIII Congresso SIF Napoli, 18 Settembre F. Cappella

Direkte Suche nach Dark Matter

Search for Dark Matter with Liquid Argon and Pulse Shape Discrimination

Neutron Calibration System for the MiniCLEAN Experiment. Lu Feng for the MiniCLEAN collaboration APS April Meeting May 2, 2011

Luca Grandi.

1. Motivation & Detector concept 2. Performance 3. Confirmation experiments 4. Summary

Whither WIMP Dark Matter Search? Pijushpani Bhattacharjee AstroParticle Physics & Cosmology Division Saha Institute of Nuclear Physics Kolkata

The XENON Project. M. Selvi The XENON project

The XENON100 Dark Matter Experiment at LNGS: Status and Sensitivity

arxiv: v2 [hep-ex] 23 Mar 2017

The relevance of XENON10 constraints in this low-mass region has been questioned [15] C.E. Aalseth et al. arxiv: v1

Recent results from PandaX- II and status of PandaX-4T

The COSINUS project. development of new NaI- based detectors for dark ma6er search. STATUS report Karoline Schäffner

Measurements of liquid xenon s response to low-energy particle interactions

The 46g BGO bolometer

TWO-PHASE DETECTORS USING THE NOBLE LIQUID XENON. Henrique Araújo Imperial College London

Esperimenti bolometrici al Gran Sasso: CUORE e CRESST

XMASS: a large single-phase liquid-xenon detector

Shedding Light on Dark Matter from Deep Underground with XENON. Kaixuan Ni (Columbia)

Energy calibration of the threshold of Medipix for ATLAS

Direct Search for Dark Matter

Background and sensitivity predictions for XENON1T

Looking for WIMPs A Review

Dark Matter Search Results from the Silicon Detectors of the Cryogenic Dark Matter Search Experiment

Status of DM Direct Detection. Ranny Budnik Weizmann Institute of Science

Bubble Chambers for Dark Matter Detection

Direction-Sensitive Dark Matter Search --NEWAGE--

PHY326/426 Dark Matter and the Universe. Dr. Vitaly Kudryavtsev F9b, Tel.:

Sensitivity of sodium iodide cryogenic scintillation-phonon detectors to WIMP signals

LUX: A Large Underground Xenon detector. WIMP Search. Mani Tripathi, INPAC Meeting. Berkeley, May 5, 2007

THE ACTIVE PERSONNEL DOSIMETER - APFEL ENTERPRISES SUPERHEATED DROP DETECTOR*

C. Galbiati Princeton

The Neutron/WIMP Acceptance In XENON100

The next generation dark matter hunter: XENON1T status and perspective

Backgrounds and Sensitivity Expectations for XENON100

Laboratori Nazionali del GranSasso Alfredo G. Cocco Istituto Nazionale di Fisica Nucleare Sezione di Napoli

arxiv:astro-ph/ v1 15 Feb 2005

CDMS-II to SuperCDMS

arxiv: v1 [astro-ph.im] 28 Sep 2010

Light Dark Matter and XENON100. For the XENON100 Collaboration Rafael F. Lang Columbia University

Investigation of pulse shapes and time constants for NaI scintillation pulses produced by low energy electrons from beta decay

Background Characterization and Rejection in the LZ Detector. David Malling Brown University IDM 2012 July 25, 2012

arxiv: v1 [physics.ins-det] 1 Nov 2011

Background optimization for a new spherical gas detector for very light WIMP detection

Prospects for WIMP Dark Matter Direct Searches with XENON1T and DARWIN

Transcription:

Constraints on Low-Mass WIMPs from PICASSO Carsten B. Krauss University of Alberta for the PICASSO Collaboration IDM Chicago, July 25 2012

Spin-Dependent or Spin-Independent Interaction xxx ^> c* 4 9 9 4 4 Axial-vector, Spin-dependent Scalar, spin independent The neutralino is a superposition of Higgsino, Zino and photino, depending on the model. A spin-carrying, Majorana type neutralino would interact by Z exchange and squark interaction

Spin or no Spin In order to identify what model of physics is realized, both SI and SD cross sections should be measured. Barger, V., Keung, W.-Y., & Shaughnessy, G. (2008). Spin dependence of dark matter scattering. Physical Review D, 78(5), 056007

PICASSO Project in Canada to search for Supersymmetric Objects. The experiment is located at SNOLAB in Sudbury, Ontario. Collaboration has members from Canada, the US, the Czech Republic, and India.

Superheated Droplet & Alpha Track Freon droplets suspended in gel matrix. Each droplet is like a mini-bubble chamber. Nucleations are triggered along the charged particle track and initiate a phase transition.

Superheated Droplet & Alpha Track Alpha track Freon droplets suspended in gel matrix. Each droplet is like a mini-bubble chamber. Nucleations are triggered along the charged particle track and initiate a phase transition.

Superheated Droplet & Alpha Track Nucleation cores Freon droplets suspended in gel matrix. Each droplet is like a mini-bubble chamber. Nucleations are triggered along the charged particle track and initiate a phase transition.

Superheated Droplet & Alpha Track Freon droplets suspended in gel matrix. Each droplet is like a mini-bubble chamber. Nucleations are triggered along the charged particle track and initiate a phase transition.

Superheated Droplets and Nuclear Recoils Recoil track is much shorter. Typically only a single nucleation will occur. Much larger de/dx will still initiate phase transition and cause bubble to explode.

Superheated Droplets and Nuclear Recoils 19 F Recoil Recoil track is much shorter. Typically only a single nucleation will occur. Much larger de/dx will still initiate phase transition and cause bubble to explode.

Superheated Droplets and Nuclear Recoils Nucleation core Recoil track is much shorter. Typically only a single nucleation will occur. Much larger de/dx will still initiate phase transition and cause bubble to explode.

Superheated Droplets and Nuclear Recoils Recoil track is much shorter. Typically only a single nucleation will occur. Much larger de/dx will still initiate phase transition and cause bubble to explode.

Detector Contains gel matrix to keep superheated droplets suspended. No longer uses CsCl to match density of droplets to gel. We have increased purity and reduced background in every generation of detector.

Purification Continued efforts to improve purification have resulted in lower internal background levels in the gel matrix.

Detector Response Threshold detector, with different response to different types of radiation: Alphas have the lowest threshold, MIPs the highest. A 50GeV WIMP would have a response as shown

Detector Response Alpha Sources: 226 Ra spike 146 kev recoil 241 Am spike 66 kev bragg peak Threshold detector, with different response to different types of radiation: Alphas have the lowest threshold, MIPs the highest. A 50GeV WIMP would have a response as shown

Detector Response Am/Be Neutron Source Alpha Sources: 226 Ra spike 146 kev recoil 241 Am spike 66 kev bragg peak Threshold detector, with different response to different types of radiation: Alphas have the lowest threshold, MIPs the highest. A 50GeV WIMP would have a response as shown

Detector Response Am/Be Neutron Source Alpha Sources: 226 Ra spike 146 kev recoil 241 Am spike 66 kev bragg peak 22 Na Gammas Threshold detector, with different response to different types of radiation: Alphas have the lowest threshold, MIPs the highest. A 50GeV WIMP would have a response as shown

Detector Response Am/Be Neutron Source Alpha Sources: 226 Ra spike 146 kev recoil 241 Am spike 66 kev bragg peak 50GeV WIMP 22 Na Gammas Threshold detector, with different response to different types of radiation: Alphas have the lowest threshold, MIPs the highest. A 50GeV WIMP would have a response as shown

Calibrated Energy Threshold Alpha Sources: 226 Ra spike 146 kev recoil 241 Am spike 66 kev bragg peak We have access to a Tandem accelerator that produces monoenergetic neutrons. Our threshold is now calibrated down to 0.8 kev!

Calibrated Energy Threshold Alpha Sources: 226 Ra spike 146 kev recoil 241 Am spike 66 kev bragg peak We have access to a Tandem accelerator that produces monoenergetic neutrons. Our threshold is now calibrated down to 0.8 kev!

Detector Calibration Detector response to mono-energetic neutrons with decreasing energies down to 4.8 kev. The neutrons are from 51 V(p,n) 51 Cr and 7 Li(p,n) 7 Be reactions. S Archambault et al 2011 New J. Phys. 13 043006

Acoustic Discrimination We discovered that the acoustic signal of the bubble nucleation contains information about the type of particle interaction. The signal amplitude is larger for alpha interactions. New Journal of Physics 10 (2008) 103017

Acoustic Discrimination We discovered that the acoustic signal of the bubble nucleation contains information about the type of particle interaction. The signal amplitude is larger for alpha interactions. New Journal of Physics 10 (2008) 103017

Progress since 2009 Moved the experiment to larger space within SNOLAB. Upgraded DAQ to double the bandwidth. This improves background rejection. Several new properties of the existing data are now exploited in the 2012 analysis.

Neutron Background The new system has 60 cm of water shield around the detectors, the old one only had 30cm. The neutrons shielding efficiency is larger than 99.6% compared to 98% in the old setup. We do not expect to be able to pick up any neutron events in the exposure of 115 kgd (in the old setup).

Event Selection New variable RVAR, quantifying the rise time behaviour allows to efficiently discriminate acoustic PVAR The old PVAR, a measure of the acoustic power of the background up to 48 C (1.7 kev threshold). event is also used.

2012 Data Data set of 115kg days of exposure. Background subtracted data from all 10 detectors as function of threshold energy. WIMP with 7 GeV mass and 1.2x10-4 pb shown.

Results: Spin Dependent Archambault, et al., Physics Letters B, 711(2), 153 161. Best limit of σsd = 0.032 pb (90% C.L.) for WIMP masses around 20 GeV. (Width of the 2012 curve is from varying the resolution parameter a from 2.5 to 7.5)

Results: Spin-Independent Archambault, et al., Physics Letters B, 711(2), 153 161. Due to the light target nucleus PICASSO is competitive at the low end of the mass spectrum, 7 GeV: σsi = 1.41 10 4 pb (90% C.L.)

Future The PICASSO will not pursue droplet detectors past the current phase. The droplet detector has allowed us to study interactions in superheated C4F10 in detail. Goal for background less large detector using C4F10.

Summary & Outlook PICASSO has analysed the complete data set of the original SNOLAB setup. Since then the experiment has moved, the data acquisition has been upgraded and the neutron shield has been enhanced. Many new analysis tools and features were developed. PICASSO is currently exchanging all detectors by new, low background saltless detectors. The new detectors show exceptional rate behaviour in the current data taking. With new DAQ and improvements in the analysis we expect to reach a sensitivity of at least one order of magnitude below the current limits. These upgrades will also allow us to make full use of the acoustic discrimination. PICASSO is developing a large scale detector.