OVERVIEW Overview: The KPS series staircase swirl diffusers belong to the underchair diffuser category; ideal for places where the best comfort levels are desired both in temperature and acoustics. Cinemas, theatres and conference halls are some examples. Technical characteristics: The KPS series staircase swirl diffusers are realized in the models: -QQ squared diffuser, squared finned surface; -QC squared diffuser, circular finned surface; -CC circular diffuser, circular finned surface. Installation : With subframe -QQ-P -QC-P -CC-P With spigot and equalizer -QC-C -CC-C -QQ Finishing : Epoxy powder coating RAL 9 color Direction of the throw The spigor with equalizer ensures a horizontal air throw. -QC -CC U1 Diffusion-vers_17_.xls U1-11
OVERALL DIMENSIONS -QQ -QC -CC -QQ-P -QC-P -CC-P Fixing with spigot and equalizer -QC-C -CC-C U1 Diffusion-vers_17_.xls U1-12
INSTALLATIONS Mounting at the stair Angled throw Mounting at the floor Angled throw Mounting at the stair Fixing with spigot and equalizer Predominantly horizontal throw U1 Diffusion-vers_17_.xls U1-13
PERFORMANCES -QQ-P -QQP Stair Throw,7 9 m³/h,6 8 m³/h, 7 m³/h,4 m³/h 4 m³/h,,2,,,3,4,,6,7,8,9 1 1,1 Squared diffuser, squared finned surface Aeraulic data measured in isothermal conditions in accordance with international standard: ISO 219 1984: Air distribution and air diffusion - Laboratory. Aerodynamic testing and rating of air terminal devices.,,4 -QQP Floor Throw 9 m³/h 8 m³/h Acoustic data measured in reverberation room in accordance with international standard: ISO 3741 1999: Acoustic - determination of sound power levels of noise sources using sound pressure - Precision methods for reverberation rooms,,2 7 m³/h m³/h 4 m³/h ISO 13 1997: Acoustic - determination of sound power levels of noise from air-terminal devices ; air terminal units; dampers and valves by measurement in a reverberation room.,,,3,4,,6,7,8,9 1 1,1 3 -QQP Pressure drop The data in the diagrams does not consider the attenuation due to the installation environment. This attenuation is usually between 6 and dba and is determined by the size and shape of the environment and the characteristics of the furnishings. 2 Δp (Pa) 2 4 6 7 8 9 4 4 -QQP Sound power Lw (dba) 3 2 2 4 6 7 8 9 U1 Diffusion-vers_17_.xls U1-14
PERFORMANCES -CC-P -QC-P,7 8 m³/h,6 6 m³/h, m³/h,4 4 m³/h 3 m³/h,,2,,,3,4,,6,7,8,9 1 1,1, 8 m³/h,4 6 m³/h, m³/h 4 m³/h,2 3 m³/h,,,3,4,,6,7,8,9 1 1,1 3 CCP-QCP Stair Throw CCP-QCP Floor Throw CCP-QCP Pressure drop Circular diffuser, circular finned surface Squared diffuser, circular finned surface Aeraulic data measured in isothermal conditions in accordance with international standard: ISO 219 1984: Air distribution and air diffusion - Laboratory. Aerodynamic testing and rating of air terminal devices. Acoustic data measured in reverberation room in accordance with international standard: ISO 3741 1999: Acoustic - determination of sound power levels of noise sources using sound pressure - Precision methods for reverberation rooms ISO 13 1997: Acoustic - determination of sound power levels of noise from air-terminal devices ; air terminal units; dampers and valves by measurement in a reverberation room. The data in the diagrams does not consider the attenuation due to the installation environment. This attenuation is usually between 6 and dba and is determined by the size and shape of the environment and the characteristics of the furnishings. 2 Δp (Pa) 2 4 6 7 8 9 Lw (dba) CCP-QCP Sound power 4 4 3 2 2 4 6 7 8 9 U1 Diffusion-vers_17_.xls U1-
PERFORMANCES -CC-C -QC-S, 9 m³/h,4 8 m³/h 6 m³/h, m³/h 38 m³/h,2,,,3,4,,6,7,8,9 1 1,1 Δp (Pa) Lw (dba) -CCC-QCC Stair Throw -CCC-QCC Pressure drop 4 4 3 2 2 4 6 7 8 9 -CCC-QCC Sound power 4 4 3 2 2 4 6 7 8 9 Circular diffuser, circular finned surface Squared diffuser, circular finned surface Fixing with spigot and equalizer With this mounting installation at the floor is not recommended Aeraulic data measured in isothermal conditions in accordance with international standard: ISO 219 1984: Air distribution and air diffusion - Laboratory. Aerodynamic testing and rating of air terminal devices. Acoustic data measured in reverberation room in accordance with international standard: ISO 3741 1999: Acoustic - determination of sound power levels of noise sources using sound pressure - Precision methods for reverberation rooms ISO 13 1997: Acoustic - determination of sound power levels of noise from air-terminal devices ; air terminal units; dampers and valves by measurement in a reverberation room. The data in the diagrams does not consider the attenuation due to the installation environment. This attenuation is usually between 6 and dba and is determined by the size and shape of the environment and the characteristics of the furnishings. U1 Diffusion-vers_17_.xls U1-16
HOW TO ORDER Staircase swirl diffuser QQ squared diffuser, squared finned surface QC squared diffuser, circular finned surface CC circular diffuser, circular finned surface P C fixing with subframe fixing with spigot and equalizer (*) Size (**) QQ P 18 (*) available for and -QC-CC not avaiable for -QQ (**) actual production only size 18 U1 Diffusion-vers_17_.xls U1-17
U1 Diffusion-vers_17_.xls U1-18