Combustion Ion Chromatography. Fast and reliable determination of halogens and sulfur using pyrohydrolysis

Similar documents
Combustion Ion Chromatography. Fast and reliable determination of halogens and sulfur

Combustion Ion Chromatography. Fast and reliable determination of halogens and sulfur

Air Monitoring. Semi-continuous determination of ambient air quality

Analysis of various clays with Metrohm Combustion IC

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise.

883 Basic IC plus. The smallest Metrohm ion chromatograph

Suppression in anion chromatography. More sensitive analysis of anions and organic acids

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

861 Advanced Compact IC

Ion chromatography. Ion chromatography

DETERMINATION OF TOTAL HALOGEN CONTENT IN HALOGEN-FREE FLUXES BY INDUCTIVELY COUPLED PLASMA AND SOME LIMITATIONS OF ION CHROMATOGRAPHY

Metrohm Inline Sample Preparation. Making your ion chromatography more efficient

Metrohm Inline Sample Preparation. Ion chromatography analyses could not be easier

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

Determination of chlorine, bromine, and sulfur in polyethylene materials using combustion IC with a carbonate/bicarbonate eluent

Cyanide and sulfide analysis using amperometric detection and Metrosep A Supp /4.0

ION CHROMATOGRAPHY SYSTEM S 150

Intelligent Ion Chromatography. 850 Professional IC 872 Extension Module 858 Professional Sample Processor

Mobile coulometer for water determination anywhere you want

novaa 800 D Atomic Absorption Spectrometer

Automation in ion chromatography. Save time and money through automated sample preparation and analysis

Automation in ion chromatography. Save time and money through automated sample preparation and analysis

Determination of Adsorbable Organic Halogen in Wastewater

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Burning Through the Confusion: See How Combustion IC Provides Superior Halide Analysis

Application Note S/SL

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Basic Digestion Principles

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Determination of Chloride, Fluoride, Bromide, Nitrate, Sulphate and Phosphate in Water Sample...

OXITEST Oxidation Test Reactor

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

Theory of Ion Chromatography

HPLC Praktikum Skript

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

costech instruments ECS 4010 Elemental Combustion System CHNS-O

110 Lowell Rd Hudson, NH USA Tel:

2Fe 2 O 3 +3H 2 S FeS+FeS x +S+3H 2 O

Analysis of domestic sludge using the Agilent 4200 MP-AES

Petrochemical. Transformer Oil Gas Analysis - TOGA

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Sulfur speciation in mining leachates by ion exchange with direct UV detection, using a perchlorate mobile phase.

Ion Analysis of Hydraulic Fluids in Fracking Process

Hydra-C Application Note: 1076

Product Descriptions and Offerings

Chromatography. Gas Chromatography

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Mira Metrohm Instant Raman Analyzer. Always ready to measure

Chlorinated Compounds in Hydrocarbon Streams Using a Halogen Specific Detector (XSD)

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Atomic Absorption Spectrometer ZEEnit P series

TYPES OF CHEMICAL REACTIONS

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

The art of elemental analysis

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

Maintenance with OQ. ZEEnit 700. Operational Qualification OQ within the scope of a maintenance for the. Atomic Absorption Spectrometer

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Dionex IonPac AS28-Fast-4µm column

S8 TIGER Series 2 for ASTM D 6443

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

FEATURE ARTICLE. The CS-100 Series High-precision Chemical Solution Monitor in the Semiconductor Cleaning Process. Takaaki Yada.

Reprinted from February Hydrocarbon

Method Transfer between HPLC and UHPLC Instruments Equipment-related challenges and solutions

Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Method for Nitrite determination on Low-Range Samples

Chapter 31 Gas Chromatography. Carrier Gas System

Fine Particles: Why We Care

Elemental Analysis: CHNS/O characterization of polymers and plastics

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Automatic determination of the bromine number and the bromine index in petroleum products

Accurate and Precise Sulfur Analysis using the Thermo Scientific FlashSmart Elemental Analyzer

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

White Paper. Overview: NDIR Definition:

ERALY SERVOCOULOMETRE MIPO5: DETERMINATION OF CHLORINE AND BROMINE

columns IonPac AS17-C Anion Exchange Column

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Making Improvements to Today s Natural Gas Analysis Systems

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

2035 Process Analyzer. Customized online monitoring of industrial processes and wastewater

Agilent G2350A Atomic Emission Detector (AED)

Mole Conversions Worksheet

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

Kjeltec 2300 Analyzer Unit

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

Thermal Analysis Premium

Inline sample preparation for the determination of anions in sodium hydroxide

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

Headspace Technology for GC and GC/MS: Features, benefits & applications

0620 CHEMISTRY. Mark schemes should be read in conjunction with the question paper and the Principal Examiner Report for Teachers.

ISEmax CAM40/CAS40. Technical Information

Transcription:

Combustion Ion Chromatography Fast and reliable determination of halogens and sulfur using pyrohydrolysis

Combustion digestion and ion chromatography combined in one system 02 Combustion Ion Chromatography (CIC) extends the range of ion chromatography to all types of combustible samples. The focus here is primarily on the simul taneous de ter mination of the various halogens and sulfur in wi dely differing matrices. The Metrohm CIC System, including sample preparation, is completely automated. CIC is superior to offline digestion methods with regard to sample throughput on the one hand and precision and correctness of the results on the other. With CIC, unlike with alternative methods, the concentrations of the different halogens can each be de termined separately. The principle In CIC the samples are first digested under an argon at mosphere in the oven unit and then burnt with oxygen and water (Pyrohydrolysis). In the 920 Absorber Module, the resulting gaseous compounds are passed into an absorption solution, which is then transferred inline to a Metrohm ion chromatography system, where it is analyzed. Schematic representation of a complete Combustion IC system Configuration with an 930 Compact IC Flex Oven/SeS/PP/Deg, a 920 Absorber Module and a Combustion Module from Analytik Jena equipped with solid autosampler

The advantages of CIC at a glance Extended range of application of IC for all kinds of combustible samples (solid, liquid, gaseous) Simultaneous determination of sulfur and halogens Quantification of the concentration for each halogen Ideal for checking the latest analytical standards with regard to halogen-free products (RoHS, WEEE...) High sample throughput, precision, and accuracy MagIC Net ion chromatography software for control and data management all information in one sample table or report Flame sensor ensures optimum combustion time with an universal method Compliance with FDA and GLP standards Calibration with just one standard thanks to Metrohm intelligent Partial Loop Injection Technique (MiPT) Fully automated sample preparation for solid and liquid samples with just one modular sample changer 03

04 Applications CIC is ideal for routine analysis in a variety of fields, as neither details about the nature of the sample matrix need to be known nor complicated method development is necessary. Not only is CIC recommended for quality control of raw materials, intermediates and finished products, but the method is also suitable for straigthforward and exact monitoring of compliance with the relevant laws, standards and regulatory requirements in the environmental field (e.g. DIN EN 228, IEC 60502 1, RoHS, WEEE,...). Examples of areas and products where analyses are possible with CIC: environmentally relevant substances (oil, plastic waste, glass, activated carbon,...) electronic components (printed circuit boards, resin, cables, insulation,...) fuels (gasoline, kerosene, crude oil, heating oil, coal, butane, propane, natural gas, catalysts,...) plastics (polymers such as polyethylene, polypropylene,...) coloring agents (pigments, paints,...) pharmaceutical products (raw substances, intermediates, finished products,...) foods (oils, spices, flavorings and fragrances,...) Conductivity [µs/cm] 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 chloride bromide sulfate Conductivity [µs/cm] 180 160 140 120 100 80 60 40 20 1.6 0.8 chloride 0.0 0 2 4 6 8 10 12 14 Time [min] chloride sulfate 0.0 0 2 4 6 8 10 12 14 16 18 Time [min] 20 0 0 2 4 6 8 10 12 14 16 18 20 Time [min] Determination of halogens and sulfur in certifi ed polyethylene pellets ERM EC681k: chloride: 102.4%, bromide 95.4%, sulfur 100.3%. Injection volume 20 µl Determination of halogens and sulfur in coal reference material NIST 2682b: chloride: 103.4%, sulfur 96.8%. Injection volume 100 µl Conditions (both analyses): Metrosep A Supp 5 150/4.0; eluent: 3.2 mmol/l Na 2 CO 3, 1.0 mmol/l NaHCO 3, 0.7 ml/min; column temperature 30 C; oven temperature 1050 C; absorption solution: 100 mg/l H 2 O 2 Metrohm CIC complies with international norms and standards like for example... ASTM D7359-14 Standard Test Method for Total Fluo rine, Chlorine and Sul fur in Aromatic Hydro carbons and Their Mixtures by Oxidative Pyrohydrolytic Combustion followed by Ion Chromatography Detection (Combustion Ion Chroma to graphy CIC) UOP991-13 Chloride, Fluoride, and Bromide in Liquid Or ganics by Com bustion Ion Chromato graphy (CIC) ASTM D5987-96 Standard Test Method for Total Fluorine in Coal and Coke by Pyrohydrolytic Ex traction and Ion Selective Electrode or Ion Chromatograph Methods ASTM D7994-17 Standard Test Method for Total Fluorine, Chlorine, and Sulfur in Liquid Petroleum Gas (LPG) by Oxidative Pyrohydrolytic Combustion Followed by Ion Chromatography Detection (Combustion Ion Chromatography CIC)

05 A flame sensor measures the intensity of light in the Combustion Module and controls the combustion digestion automatically. Combustion digestion controlled automatically Metrohm s CIC consists of a Combustion Module from Analytik Jena and an absorption and IC part from Metrohm. In the Combustion Module the sample digestion can be controlled automatically. The principle is simple. An optical fiber transfers the light emitted during combustion from the pyrolysis oven to an optical sensor. The optical sensor measures the intensity of the light and controls the feed rate of the sample boat into the oven in proportion to it. Hence the duration of the combustion is optimized so that, firstly, combustion is always com plete (no soot formation), and, secondly, there is no need for waiting times as a safety buffer. Thanks to the automated control of sample digestion, method development for combustion is not needed. Different samples as well as different sample quantities can be subjected to one and the same universal «method». If norms have to be followed which define combustion for a specific time at a specific temperature, the sample inlet into the oven can also be programmed manually. CIC automation The MMS 5000 autosampler ensures fully automatic introduction of solid and liquid samples. With the appropriate kit for liquid or solid samples, respectively, this multi-matrix sampler can be converted in minutes with out much effort. The combustion system is unaffected and can therefore be brought back into operation within a few minutes. CIC automation. Liquid or solid samples the MMS 5000 autosampler can work with both.

Reliable operation under high pressure: LPG/GSS Gas Module and LPG Module 06 The LPG/GSS Gas Module makes it possible to analyze both liquefied gases (LPG) and gaseous samples (GSS) such as natural gas using Combustion IC. The LPG Module on the other hand allows the analysis of liquefied gases, which however, may be subjected to much higher pressures. The Dosing volume for all types of samples can be selected freely, something which even allows calibration of a wide concentration range without the need for an additional calibration gas standard. Moreover the separate flow paths for LPG and GSS in the LPG/ GSS Gas Module eliminate any risk of contamination. MagIC Net controls the Gas Modules fully automatically. A special dosing valve that uses Peltier cooling is used for dosing liquefied gases, which prevents the sample from being released prematurely. Following the sampling process, the liquefied gas is vaporized in a heated chamber. This enables even components that are less easily volatilized to be brought into a gaseous state. The sample is fully transferred to the combustion system, a process that is also supported by a permanent flow of argon rinsing gas. This prevents memory effects. 2.136.0720 LPG/GSS Gas Module for analyzing gases in liquefied and gaseous states 2.136.0740 LPG Module for the analysis of LPG

07 Key parameters for gas analysis using Combustion IC LPG/GSS Gas Module LPG Module Sample cylinder pressure Max. 18 bar (260 psi) Max. 250 bar (3625 psi) Max. 31 bar (450 psi) Pressure at sample valve Determined by sample cylinder 0.7 1.7 bar, typically at 1 bar Determined by sample cylinder Sample volume 1 250 µl in 1 µl steps 1 65 ml in 250 µl steps 1 250 µl in 1 µl steps Temperature of decompression chamber 85 C 85 C

CIC at a glance 08 Straightforward operation Once the sample table has been created, the Combustion IC system operates entirely automatically. All parameters are controlled by MagIC Net software. The system is automatically switched off after a determination series, which saves costs in cases where for example expensive gases are being used. Highly flexible The MMS 5000 sample changer makes the system highly flexible. The sample changer can be retrofitted to handle liquid samples instead of solid ones within two minutes meaning that just one sample changer is required. Moreover, there is no need to readjust the gas line when changing bet ween different types of sample, saving valuable time. Straightforward calibration Thanks to the Metrohm intelligent Partial Loop Injection Technique (MiPT), calibration can be performed ra pidly, reliably, and above all automatically, using a single multi-ion standard. This saves time and is less prone to error.

Reliable CIC is superior to offline digestion methods, not only with respect to sample throughput, but also in terms of precision and trueness of the results. Check standards for calibration and reference materials for the samples also increase the reliability of CIC. Flame sensor technology Whether solid or liquid samples are analyzed, or the amount of sample varies, the flame sensor optimizes the combustion process. This ensures fast, soot-free combustion. 09 No internal standard required MagIC Net documents all liquids that are dosed to the absorption solution. As a result, there is no need for an internal standard in the absorption solution. This prevents any undesirable dilution effects and also any interference between the internal standard and the analytes in the chromatogram.

Perfect liquid handling the 920 Absorber Module 10 In the Metrohm CIC System the Combustion Mo dule and ion chromatograph are linked together by the 920 Ab sorber Module. The 920 Absorber Module ensures that the gaseous compounds of the analytes are brought into solution. The professional liquid handling also includes the input of water for combustion, matrix elimination of the hydrogen peroxide (oxidizing agent), and rinsing procedures. Moreover, a single multi-ion standard may be used for an automated calibration of the system by means of the Metrohm intelligent Partial Loop Injection Tech nique (MiPT). Because MiPT allows flexible injection vo lumes (4 200 µl), a large concentration range can be cove red. The following items are available for the entire liquid handling: a 10-port valve, a 6-port injection valve and two paten ted Metrohm 800 Dosino Dosing Units. The 920 Absorber Module can also be used as a semionline sampler for direct absorption of gas compounds (NH 3, HNO 2, HNO 3, HCl, SO 2 ) from the air. In this way, for example, volatile organic acids (hydrochloric acid, sulfuric acid) can be monitored in process flue gases or in the am bient air at workplaces. 930 Compact IC Flex 920 Absorber Module Combustion Module

Straighforward control with MagIC Net software The complete CIC system is controlled by MagIC Net, the proven software for ion chromatography. MagIC Net offers great flexibility with regard to configuration, layout and method programming. Several monitoring and control func tions are available to the user. MagIC Net meets all FDA and GLP requirements and is also available in numerous languages. A modern data management system and a powerful report generator round off the package. MagIC Net guarantees easy, robust, and reliable hand ling of the system. The user is able at all times to keep an overview of all the liquid quantities that are introduced into the absorption solution. Consequently, it is possible to work without an internal standard or other tools.

Ordering information Metrohm markets the complete system, including installation, service and training all from the same supplier. Instruments Combustion IC packages 2.930.9010 Metrohm Combustion IC PP. The package includes: 2.930.2560 Compact IC Flex Oven/SeS/PP/Deg 2.850.9010 IC Conductivity Detector 2.920.0010 Absorber Module 2.136.0700 Combustion Module (Oven and ABD) 6.2832.000 MSM Rotor A 6.2842.020 Adapter for Vario for MSM 6.6059.321 MagIC Net 3.2 Compact 6.1006.340 Metrosep A PCC 2 HC/4.0 2.930.9020 Metrohm Combustion IC DR. The package includes: 2.930.2460 Compact IC Flex Oven/SeS/Deg 2.850.9010 IC Conductivity Detector 2.920.0010 Absorber Module 2.136.0700 Combustion Module (Oven and ABD) 6.2832.000 MSM Rotor A 6.2842.020 Adapter for Vario for MSM 6.6059.321 MaglC Net 3.2 Compact 6.1006.340 Metrosep A PCC 2 HC/4.0 2.800.0020 800 Dosino 6.3032.120 Dosing Unit 2 ml 2.136.0700 Combustion Module (Oven and ABD) 2.136.0710 Auto Boat Drive (ABD) 2.136.0720 LPG/GSS Module (including coupling to ABD) 2.136.0730 Combustion Module (Oven and LPG/GSS, including direct coupling 6.7304.030 to oven) 2.136.0740 LPG Module (including coupling to ABD) 2.136.0750 Combustion Oven 6.7304.030 Direct coupling of LPG/GSS Module to oven Subject to modifications Layout by Ecknauer+Schoch ASW, printed in Switzerland by Metrohm AG, CH-9100 Herisau 8.000.5248EN 2017-12 Sample changers 2.136.0800 Autosampler MMS 5000 (sample rack not included) 6.7302.000 MMS 5000 Kit for solid samples 6.7303.000 MMS 5000 Kit for liquid samples Columns 6.01032.420 Metrosep A Supp 17-150/4.0 6.01032.500 Metrosep A Supp 17 Guard/4.0 www.metrohm.com