ScienceDirect. Gnielinski Method in Calculating the Heat Transfer Coefficient for Metallic Solar Tower Absorber

Similar documents
Available online at ScienceDirect. Energy Procedia 69 (2015 )

Available online at ScienceDirect. The Malaysian International Tribology Conference 2013, MITC2013

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

ScienceDirect. Simulating Friction Power Losses In Automotive Journal Bearings. H. Allmaier a, D.E. Sander a, F.M. Reich, a, *

Comparative study of Different Geometry of Ribs for roughness on absorber plate of Solar Air Heater -A Review

International Journal of Advanced Engineering Technology E-ISSN

Theoretical prediction of performance of Single and Double pass solar air heaters with artificial roughened absorber plates

A Computational Fluid Dynamics Investigation of Solar Air Heater Duct Provided with Inclined Circular Ribs as Artificial Roughness

Fluid Flow and Heat Transfer Characteristics in Helical Tubes Cooperating with Spiral Corrugation

EFFECT OF STAGGERED RIB LENGTH ON PERFORMANCE OF SOLAR AIR HEATER USING V-RIB WITH SYMMETRICAL GAP AND STAGGERED RIB

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 06, 2015 ISSN (online):

Effect of tube pitch on heat transfer in shell-and-tube heat exchangers new simulation software

New Regenerator Design For Cryocoolers

Available online at ScienceDirect. Procedia Engineering 90 (2014 )

Available online at ScienceDirect. Procedia Engineering 157 (2016 ) 44 49

Thermo-Fluid Performance of a Vapor- Chamber Finned Heat Sink

NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF A V-RIB WITH GAP ROUGHENED SOLAR AIR HEATER

Available online at ScienceDirect. Procedia Engineering 90 (2014 )

In order to optimize the shell and coil heat exchanger design using the model presented in Chapter

Available online at ScienceDirect. Energy Procedia 79 (2015 )

Heat transfer coefficient of near boiling single phase flow with propane in horizontal circular micro channel

Computational Fluid Dynamics Based Analysis of Angled Rib Roughened Solar Air Heater Duct

Modeling and simulation of fixed bed regenerators for a multi-tower decoupled advanced solar combined cycle

EFFECT OF DIFFERENT PARAMETERS ON THE PERFORMANCE OF RIB ROUGHNESS SOLAR DUCT

Available online at ScienceDirect. Procedia Engineering 106 (2015 ) Dynamics and Vibroacoustics of Machines (DVM2014)

A Numerical Study of Forced Convection Heat Transfer for Staggered Tube Banks in Cross-Flow

Available online at ScienceDirect. 68th Conference of the Italian Thermal Machines Engineering Association, ATI2013

Laminar Forced Convection and Heat Transfer Characteristics in a Square Channel Equipped with V-Wavy Surface

Oscillating Flow Characteristics of a Regenerator under Low Temperature Conditions

Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters

SSRG International Journal of Mechanical Engineering ( SSRG IJME ) Volume 2 Issue 5 May 2015

Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition

The Fluid Flow in the T-Junction. The Comparison of the Numerical Modeling and Piv Measurement

MINIMIZATION OF ENTROPY GENERATION AND PRESSURE DROP FOR HYBRID WIRE MESHREGENERATIVE HEAT EXCHANGER

Using sand and other small grained materials as heat storage medium in a packed bed HTTESS

Circle one: School of Mechanical Engineering Purdue University ME315 Heat and Mass Transfer. Exam #2. April 3, 2014

ScienceDirect. Unit cell model of woven fabric textile composite for multiscale analysis. Anurag Dixit a *,Harlal Singh Mali b, R.K.

Available online at ScienceDirect. Procedia Engineering 157 (2016 )

Estimation of Heat Transfer in Internally Micro Finned Tube

INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 5, ISSUE 09, SEPTEMBER 2016 ISSN

ScienceDirect Abstract

LAMINAR FORCED CONVECTION HEAT TRANSFER IN HELICAL COILED TUBE HEAT EXCHANGERS

Studies on flow through and around a porous permeable sphere: II. Heat Transfer

Parametric Effect on Performance Enhancement of Offset Finned Absorber Solar Air Heater

International Communications in Heat and Mass Transfer

Overall Heat Transfer Coefficient

Forced Convection Heat Transfer Enhancement by Porous Pin Fins in Rectangular Channels

Correlations for Double Flow Double Pass SAH with Smooth Absorber Plate

ScienceDirect. Optimization of Tribological Performance of hbn/al 2 O 3 Nanoparticles as Engine Oil Additives

Available online at ScienceDirect. Energy Procedia 79 (2015 )

International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May ISSN

Heat and Mass Transfer Unit-1 Conduction

CFD Analysis on Flow Through Plate Fin Heat Exchangers with Perforations

PERFORMANCE SCREENING OF A LOUVERED FIN AND VORTEX GENERATOR COMBINATION

Effect of roughness shape on heat transfer and flow friction characteristics of solar air heater with roughened absorber plate

W-Discrete Rib for Enhancing the Thermal Performance of Solar Air Heater

Available online at ScienceDirect. Procedia Engineering 90 (2014 )

SHELL-AND-TUBE TEST PROBLEMS

Effect of External Recycle on the Performance in Parallel-Flow Rectangular Heat-Exchangers

Analysis of Heat Transfer in Pipe with Twisted Tape Inserts

Numerical Simulation of H 2 O/LiBr Falling Film Absorption Process

Heat Transfer F12-ENG Lab #4 Forced convection School of Engineering, UC Merced.

DESIGN OF A SHELL AND TUBE HEAT EXCHANGER

Numerical Investigation on Turbulent Forced Convection in Heating Channel Inserted with Discrete V-Shaped Baffles

Department of Mechanical Engineering, VTU, Basveshwar Engineering college, Bagalkot, Karnataka, India

HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF COMPOUND TURBULATORS IN RECTANGULAR DUCTS OF SOLAR AIR HEATER

INSTRUCTOR: PM DR MAZLAN ABDUL WAHID

HEAT TRANSFER CAPABILITY OF A THERMOSYPHON HEAT TRANSPORT DEVICE WITH EXPERIMENTAL AND CFD STUDIES

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Heat Transfer Performance in Double-Pass Flat-Plate Heat Exchangers with External Recycle

Designing Steps for a Heat Exchanger ABSTRACT

Chapter 5 MATHEMATICAL MODELING OF THE EVACATED SOLAR COLLECTOR. 5.1 Thermal Model of Solar Collector System

Tutorial 1. Where Nu=(hl/k); Reynolds number Re=(Vlρ/µ) and Prandtl number Pr=(µCp/k)

Performance evaluation of heat transfer enhancement for internal flow based on exergy analysis. S.A. Abdel-Moneim and R.K. Ali*

Thermo-Hydraulic Performance of a Roughened Square Duct Having Inclined Ribs with a Gap on Two Opposite Walls

Investigation of Heat Transfer on Smooth and Enhanced Tube in Heat Exchanger

8.1 Technically Feasible Design of a Heat Exchanger

Numerical and Experimental Investigation of Heat Transfer Using Discrete Ribs

NUMERICAL SIMULATION OF THE AIR FLOW AROUND THE ARRAYS OF SOLAR COLLECTORS

A concrete heat accumulator for use in solar heating systems a mathematical model and experimental verification

Available online at ScienceDirect. Energy Procedia 83 (2015 ) Václav Dvo ák a *, Tomáš Vít a

CFD-Based Correlation Development for Air Side Performance of Wavy Fin Tube Heat Exchangers using Small Diameter Tubes

Optimization of Peripheral Finned-Tube Evaporators Using Entropy Generation Minimization

Available online at ScienceDirect. Procedia Engineering 105 (2015 )

Design of an innovative internal structure for surface solar air heater s

Convective Heat Transfer and Thermal Performance in a Circular Tube Heat Exchanger Inserted with U-Shaped Baffle

UNSTEADY MIXED CONVECTION IN A POROUS MEDIA FILLED LID-DRIVEN CAVITY HEATED BY A SEMI-CIRCULAR HEATERS

Thermo Hydraulic Performance of Solar Air Heater by Using Double Inclined Discrete Rib Roughened Absorber Plate

Influence of Tube Arrangement on the Thermal Performance of Indirect Water Bath Heaters

EFFECT OF OPERATING PARAMETERS ON THE PERFORMANCE OF WIRE SCREEN MATRIX PACKED SOLAR AIR HEATER

Chapter 3 NATURAL CONVECTION

Experimental Heat transfer study of Turbulent Square duct flow through V type turbulators

Performance evaluations of two pass solar air heater using 60⁰ inclinedvshaped ribs on absorber plate

LEAKLESS COOLING SYSTEM V.2 PRESSURE DROP CALCULATIONS AND ASSUMPTIONS

CONCENTRIC EXCHANGER TEST PROBLEMS

arxiv: v1 [physics.app-ph] 25 Mar 2018

International Journal of Heat and Mass Transfer

Effect of V-Shape Twisted Jaw Turbulators on Thermal Performance of Tube heat exchanger: An Experimental Study

GRAVITY EFFECT ON THE DISTRIBUTION OF REFRIGERANT FLOW IN A MULTI-CIRCUITED CONDENSER

Transcription:

Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 68 ( 2013 ) 293 298 The Malaysian International Tribology Conference 2013, MITC2013 Gnielinski Method in Calculating the Heat Transfer Coefficient for Metallic Solar Tower Absorber Z.M. Zulfattah a, *, S.A. Rafeq a, Z.M. Shukri a, J. Ridhwan a, M.H.M. Hanafi a, I. Norain a, Z.H. Nazri a, M.I.N. Shakinah a, A.M. Najib b a Faculty of Mechanical Engineering, Universiti Teknikal Malaysia Melaka, 76100 Durian Tunggal, Melaka, Malaysia b Faculty of Manufacturing Engineering, Universiti Teknikal Malaysia Melaka, 76100 Durian Tunggal, Melaka, Malaysia Abstract This work is done to calculate the heat transfer coefficient of metallic wire mesh to air in an open volumetric thermal absorber. It is aimed to replace the actual ceramic with metallic which latter has better thermal properties in order to increase the efficiency of the concentrating solar power plant. The calculation of the heat transfer coefficient from porous wire structure to the air has been conducted to pursue the purpose. The structure that has been chosen is a set of metallic wires with aligned and shifted configurations. The variations of wire diameter together with various porosities from 0.10 to 0.50 have been calculated to obtain the best configuration for the absorber. The flow characteristic within the mesh structure in terms of Reynolds number and its relationship with the heat transfer coefficient has been obtained. The condition on mass flow rate of heat transfer medium and other aspects which influence the heat transfer are also discussed. 2013 The Authors. Published by by Elsevier Ltd. Ltd. Open access under CC BY-NC-ND license. Selection and peer-review under under responsibility of The of Malaysian The Malaysian Tribology Tribology Society (MYTRIBOS), Society (MYTRIBOS), Department of Department Mechanical of Engineering, Mechanical Universiti Engineering, Malaya, Universiti 50603 Kuala Malaya, Lumpur, 50603 Malaysia Kuala Lumpur, Malaysia. Keywords: Porous metallic absorber; ceramic absorber; porosity; heat transfer coefficient; concentrating solar power Nomenclature m 0 in out m w A Mass flow rate of air [kg/s] Air inlet temperature [ C] Air outlet temperature [ C] Mid temperature [ C] Front absorber temperature [ C] Tail absorber temperature [ C] * Muhammad Zulfattah Zakaria. Tel.: +6-06-234-6796 ; fax: +6-06-234-6884. E-mail address: zulfattah@utem.edu.my 1877-7058 2013 The Authors. Published by Elsevier Ltd. Open access under CC BY-NC-ND license. Selection and peer-review under responsibility of The Malaysian Tribology Society (MYTRIBOS), Department of Mechanical Engineering, Universiti Malaya, 50603 Kuala Lumpur, Malaysia doi: 10.1016/j.proeng.2013.12.182

294 Z.M. Zulfattah et al. / Procedia Engineering 68 ( 2013 ) 293 298 w Flow velocity in the matrix [m/s] Dimensionless character Re xx Reynolds number Greek symbols Heat transfer coefficient [W/m²K] Fraction of hollow space Latin alphabets da Wire diameter [m] s1 Wire pitch [m] L Length of absorber cup [m] w Width of absorber cup [m] d Depth of absorber cup [m] a Ratio s1/da z Wire/row s2 Distance between rows [m] b Ratio s2/da S Stream cross-sectional area in front of absorber [m²] l Length of wire facing stream [m] P Porosity n Number of layers of metal mesh above one another P t Transverse pitch [m] r h Hydraulic radius / effective length across wire matrix [m] A Heat transfer area [m²] a v Surface area density [1/m] Mass of wire mesh [kg] m mesh 1. Introduction Concentrating Solar Tower (CST) is an advanced solar energy collecting system used to harness solar thermal energy. Solar energy is reflected by a field of heliostat and the concentrated sun ray which may reach to a factor of 600 to 1000 hits the collector or receiver located at the top of the tower [1]. This dense energy heats up the receiver rapidly and thus the most suitable material for the receiver or absorber is ceramic-based. Ceramic is a low thermal conductivity material which hinders higher power plant thermal efficiency. Action has been taken to replace the ceramic to a metallic material which has better heat transfer capability. This new metal-based absorber will be deployed at the circumference of the gigantic absorber frame where operating temperature is the lowest and suitable for metal to survive. The idea is to use wire mesh packed in the absorber cup to maximize the surface area but at an optimal porosity to avoid unnecessary load on blower unit [2-3]. Sintered porous structure which behaves like a micro mesh has been successfully used in a low temperature cryogenic application [4] while Kempers et. al. [5] applied the wire screen mesh for heat exchanger. As wire mesh is widely used in heat transfer application this research has been carefully conducted to examine whether it is also suitable for the absorber structure in CST application. The porous wire screen has been chosen as a candidate for the absorber of the CST. The work is started with measuring the size of the absorber cup, absorber structure and other parameters as shown in Table 1:

Z.M. Zulfattah et al. / Procedia Engineering 68 ( 2013 ) 293 298 295 Table 1. Absorber cup and absorber dimension (source: Solar Institute Juelich, SIJ) Dimension of cup and absorber structure Length, L [m] 0.14 Width, w [m] 0.14 Depth, d [m] 0.03 Surface area, A [m 2 ] 0.0196 Volume, V [m 3 ] 0.000588 Total absorber surface area, A_f(tot) [m 2 ] 22 Air intake, m(tot) [kg/s] 12 2. Selection of wire mesh Calculation is started with two possible wire configurations as stated by Gnielinski in the GG section which are aligned and shifted configurations [6]. Porosity for both configurations can be calculated using Eq. (1) [7]: 2 2 * n * da 1 da P 1 2* 1* s d 2 1 (1) s where n is number of layer of screens, s1 is transverse pitch of screens, da is the wire diameter and d is the depth of matrix bed. 2.1. Aligned and shifted configurations The calculation started by calculating the fraction of hollow space, (Greek: Psi) and it is dependent on the value of b which is defined as ratio of distance between layers over wire diameter, s2/da. for b 1 1 /(4a) (2) 1 2 for b 1 1 /(4ab) (3) The arrangement of tubes is then divided into two groups. One is aligned and the other is shifted. The distance between tubes in a row, s1 and the distance between rows of layers, s2 are constants and defined as: and a s1 / da (4) b s2 / da (5)

296 Z.M. Zulfattah et al. / Procedia Engineering 68 ( 2013 ) 293 298 Fig. 1. Proportionally aligned and shifted configuration of bundle of tubes. Once the parameters are programmed correctly in the software the values of s1, s2 and da are systematically manipulated and simulated using actual mass flow rate and operating temperature to get the best structure for the absorber. Shifted configuration will be calculated further as this configuration will be the most relevant configuration during production. The small wire diameter used in the application also will eventually bend creating shifted configuration when exposed to cyclic thermal loads. 2.2. Presetting the shifted configuration The operation temperature and also the set of wire mesh of the absorber are set primarily to follow the values given by Prasad et. al. [2] in order to examine the formula. After confirming that the formulas are giving the correct values the parameter of the wire mesh is then changed to the desired value for the CST absorber. The best heat transfer occurs in the least porous structure. Therefore, calculations started at fraction of hollow space of only 0.1 which means 90 percent of the cup volume is empty. Relative mass flow rate G0 of 0.5455 kg/m.s 2 as well as other parameters listed on the left of the table below are the actual air parameters during operation. The corresponding air properties are listed on the right (Table 2). Table 2. Operating condition and the corresponding air properties G0 0.5455 rel. mass flow (kg/m².s) v 6.45E-05 by m (m²/s) m 0.01069 mass flow (kg/s) 0.04996 by m W/m.K) in 20 inlet air temp. ( C) 0.517 by m (kg/m³) out 780 outlet air temp. ( C) Cp 1069 by m (J/kg.K) m 400 average air temp. ( C) Pr 0.7137 by m w 800 average absorber temp ( C) PrW 0.7342 by w

Z.M. Zulfattah et al. / Procedia Engineering 68 ( 2013 ) 293 298 297 2.3. Other setting Flow characteristics like Reynolds number, Nusselt number and also Prandtl number have been inserted into the program to calculate and simulate the real condition. 3. Results and discussion (a) (b) Fig. 2. Results using six layers of wire mesh with porosity from 0.1 to 0.5 for (a) wire diameter versus heat transfer coefficient and (b) wire diameter versus Reynolds number with corresponding. Fig 2(a) shows that the increasing amount of wire inside the absorber cup leads to a less porous structure which reduces the heat transfer ability. Increasing the layer leads to a higher which is good for the absorber cup. The best of 1111 W/m 2.K has been recorded for 1mm wire diameter with 24 mesh layers and equals to 0.1, see Fig 3. Reynolds number is recorded increasing with the diameter of the wire mesh used. Bigger wire reduces the porosity and thus intensifies the air-to-wall friction creating turbulence (Fig 2(b)). This friction increases the pressure inside the absorber and reducing the air flow rate through the cup. This situation will put unnecessary burden to the pump, create hotspot on the absorber surface and further eliminate a smooth heat transfer from the mesh to the air. (a) (b) Fig. 3. Results using 24 layers of wire mesh with porosity from 0.1 to 0.5 for (a) wire diameter versus heat transfer coefficient and (b) wire diameter versus Reynolds number with corresponding.

298 Z.M. Zulfattah et al. / Procedia Engineering 68 ( 2013 ) 293 298 4. Conclusion There is a small possibility that the wire mesh will be placed unevenly during production but this is not entertained in this task as the deviation is neglected at the early stage. The calculations to obtain the relationship of wire mesh candidates with Prandtl number, volumetric heat transfer and also effect of cyclic load on the elongation of the wire itself must be conducted. As we can see the best heat transfer coefficient comes with the smallest wire diameter and also the least porous structure. Small wire tends to bend more easily under load compares to the bigger wire. Bending of wire will eventually clog the entrance and destroy the absorber. The application itself which involves cyclic thermal loads and thermal shock will just accelerate the process. Therefore more calculations and experiments are necessary in order to choose the best material, wire size and coordination which can withstand the harsh working condition. The wise choice will make the structure to run at the optimum performance and simultaneously keep the maintenance at the longest interval. Acknowledgements Authors gratefully acknowledge the financial support for this project under the Short-Term Grant PJP/2012/FKM(59A) S1066 from Universiti Teknikal Malaysia Melaka (UTeM). References [1]F. and F. T. Hans Mueller Steinhagen, Concentrating solar power - A review of technology, Stuttgart, Germany. [2]S. B. Prasad, J. S. Saini, and K. M. Singh, Investigation of heat transfer and friction characteristics of packed bed solar air heater using wire mesh as packing material, Solar Energy, vol. 83, no. 5, pp. 773 783, May 2009. [3]C.-D. Ho, C.-S. Lin, Y.-C. Chuang, and C.-C. Chao, Performance improvement of wire mesh packed double-pass solar air heaters with external recycle, Renewable Energy, vol. 57, pp. 479 489, Sep. 2013. [4]C. Shuangtao, H. Yu, Z. Hongli, and X. Lan, A numerical model of thermal analysis for woven wire screen matrix heat exchanger, Cryogenics, vol. 49, no. 9, pp. 482 489, Sep. 2009. [5]R. Kempers, A. J. Robinson, D. Ewing, and C. Y. Ching, Characterization of evaporator and condenser thermal resistances of a screen mesh wicked heat pipe, International Journal of Heat and Mass Transfer, vol. 51, no. 25 26, pp. 6039 6046, Dec. 2008. [6]Verein Deutscher Ingenieure, VDI-Waermeatlas, 10th ed. Springer, 2006. [7]Chang W.S., Porosity and effective thermal conductivity of wire screen, ASME, Journal of Heat Transfer, no. 112, pp. 5 9, 1990.