Electrical Parameter. Measurement and Test Report for. MaxGreen LED Ltd.

Similar documents
LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W

IES LM TEST REPORT For Shenzhen sunper opto co., ltd

TEST REPORT. Test Method : See the attached sheets.

TEST REPORT. Page 1 of 11

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

IES LM MEASUREMENT AND TEST REPORT For

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IESLM-79-08TESTREPORT For KINGLUMI CO., LTD

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A

Test report of IES LM Approved Method: Electrical and Photometric

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

TEST REPORT IES LM For Signlite Opto-electronics Co.,Ltd.

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager

Sound Absorption Test Intertek. kraft paper softwall + softblock modular system. m o l o d e s i g n, l t d

IES LM MEASUREMENT AND TEST REPORT For. Eiko Limited W. 84th Street,Shawnee, KS, USA. Test Model: LEDP-13WPAR30/NFL/830-DIM

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

IES LM TEST REPORT For EIKO GLOBAL, LLC

IES LM MEASUREMENT AND TEST REPORT For

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

LM Test Report. for. Forest Lighting Corporate. LED Tube. Model: FL-T8U BN

Cat# LED Linear High Bay 100W

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA. EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

ASTM C STEADY-STATE HEAT FLUX MEASUREMENTS AND THERMAL TRANSMISSION PROPERTIES BY MEANS OF THE HEAT FLOW METER APPARATUS

MOLEKULE INC. TEST REPORT

Photometric Test Report

The Fundamentals of Moisture Calibration

TEST REPORT For Company:

For. LED Package. : Sep. 17, Date of Test. LED Light Source. Review by: Engineer:

Order No. G Date: September 8, 2010 REPORT NO CRT-001 TEST OF SMF/PAPI SYSTEM RENDERED TO

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50

TEST REPORT IEC Photobiological safety of lamps and lamp systems

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Photometric Test Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LED Lumen Maintenance and Life Test System (LEDLM-80PL) Brochure. Global Office of Lisun Electronics Inc.

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL

Intertek Environmental VOC Emissions

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL

Photometric Test Report. Keystone Technologies

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Photometric Test Report. Keystone Technologies

Test Report. Report Number: L16079 Date: Oct 12, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Certificate of Calibration Sound Level Calibrator

Morris Products 53 Carey Road, Queensbury, NY 12804

SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

CERTIFICATE OF CALIBRATION

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE SPJ Lighting 2107 Chino Ave. South El Monte, CA.

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Transcription:

~ Electrical Parameter Measurement and Test Report for MaxGreen LED Ltd. 1208-10, 12fF, Wang Cheong Enterprise Centre, 65-69 Chai Wan Kok Street, Tsuen Wan Dec 07,2012 Product Name: I Flood Light Model No: I MG-XFL-150W Test Engineer: I David Zhang Report No.: I BTR66.181.12.199.01-2 Sample Received Date: IDec 05, 2012 Test Performed Date: Dec 06, 2012 Reviewed By: Prepared By: Steven Hs BEST Test Service Shenzhen Co., Ltd. 1st Floor. 1st Building, Weitai Industrial Park, Yingrenshi, Shiyan, Baoan, Shenzhen, China TEL: +86-755-28236006 FAX: +86-755-23467087-811 Email: certification@bestcert.cn ~!~~~ Efficient Lighting Initiative Note: The test report only allows to be revised within the retention period unless further standard or the requirement was noticed. This report is for the exclusive use of BEST's Client and is provided pursuant to the agreement between BEST and its Client. BEST's responsibility and Liability are limited to the tenms and conditions of the agreement. BEST assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the BEST name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by BEST. The observations and test results in this report are relevant only to the sample tested. This report by itself does not cover that the material, product. of service is or has ever been under a BEST certification program. National Voluntary Laboratory Accreditation Program (NVLAP) has accredited this laboratory under IS017025: 2005 for specific laboratory activities as listed in the NVLAP directory of accredited laboratories. The results shown in this report were determined by this laboratory in accordance with its terms of accreditation.

MaxGreen LED Ltd. 1 - GENERAL INFORMATION Test Date Test performed Date: Dec 06, 2012 Testing agency BEST Test Service Shenzhen Co., Ltd. The Energy Efficiency Lab used by BEST to collect energy efficiency measurement data is located in 1st Floor, 1st Building, Weitai Industrial Park, Yingrenshi, Shiyan, Baoan, Shenzhen, China. BEST Test Service Shenzhen Co., Ltd is a National Institute of Standards and Technology (NIST) accredited laboratory, under the National Voluntary Laboratory Accredited Program (Lab Code 200770-0). BEST Test Service Shenzhen Co., Ltd is also an ELI accredited lab for lighting products (ELI Certificate No. ELI-L04-2010) and UL accredited lab for lighting products Adds:1st Floor, 1st Building, Weitai Industrial Park, Yingrenshi, Shiyan, Baoan, Shenzhen, China TEL: +86-755-28236006 FAX: +86-755-23467087-811 Email: certification@bestcert.cn Manufacturer's name and designation of SSL product under test Manufacture Name: MaxGreen LED Ltd. Manufacture Address: Unit 1201, 12/F, Bonham Commercial Centre, 44-46 Bonham Strand West, Sheung Wan Applicant Name: MaxGreen LED Ltd. Applicant Address: Unit 1201, 12/F, Bonham Commercial Centre, 44-46 Bonham Strand West, Sheung Wan Brands:MaxGreenLED Product Name: Flood Light Product SKU: MG-XFL-150W Measurement quantities measured Measured quantity: 1pc Date of Receiving Sample:Dec 05, 2012 Rated electrical values (clarify AC (frequency) or DC) Nominal Operation Voltage : AC 277V/60Hz Nominal Power : 150W Number of hours operated prior to measurement 0 hours Total operating time of the product for measurements including stabilization 4.0 Hours Ambient temperature 25 Report No.BTR66.181.12.199.01-2 Page 2 of 6 Electrical Parameter Test Report

MaxGreen LED Ltd. Orientation (burning position) of SSL product during test Base Up Stabilization time 3.0 Hours Equipment used Device Manufacture Model No Serial No Cal. Date Cal Due Date 5 1/2 Digital Dual Display Multimeter AC Power Source Agilent U3402A MY51310049 Oct 18, 2012 Oct 17, 2013 California Instrument 1501L L03572 N/A N/A Digital Power Meter YOKOGAWA WT210 91K310009 Oct 18, 2012 Oct 17, 2013 Second Meter TIANFU PC 396 N/A Oct 18, 2012 Oct 17, 2013 Report No.BTR66.181.12.199.01-2 Page 3 of 6 Electrical Parameter Test Report

MaxGreen LED Ltd. 2 Test Data Product Name: Flood Light Environment: Temp25.2; Humi: 47% Note: Sample No. ITHD Power Efficiency L1 13.3% 11.56 Report No.BTR66.181.12.199.01-2 Page 4 of 6 Electrical Parameter Test Report

The Test Report of PF9811 Digital Power Meter Page 1 of 2 Voltage RMS 277.0(V) Current RMS 0.586(A) Power 148.91(W) Power Factor 0.917 Freq. 60.00(Hz) Voltage Resolution: 393.18 V/div Crest Value: 393.2 V Current Resolution: 0.440 A/div Crest Value: 0.881 A 1 K 50 Voltage Spectrum UTHD: 0.4%(IEC) UH3: 0.1% UH5: 0.1% UH7: 0.1% UH9: 0.1% 1 K 50 Current Spectrum ITHD: 14.1%(IEC) IH3: 9.3% IH5: 7.1% IH7: 5.2% IH9: 3.5% Manufacturer:MAX GREEN Product type:mg-xfl-150w Temperature:25deg Verifier: Remark: Serial Num.: Humidity:65% Inspector:

The Test Report of PF9811 Digital Power Meter Page 2 of 2 Urms: 277.0 (V) Ucf : 1.42 Uthd: 0.4%(IEC) Arms: 0.586(A) Acf : 1.50 Ithd: 14.1%(IEC) Voltage Harmonic Current Harmonic Num. Relative Absolute Relative Absolute ma/w 1 100.0% 277.0 100.0% 0.58 3.90 2 0.0% 0.1 0.0% 0.00 0.00 3 0.1% 0.4 9.3% 0.05 0.36 4 0.0% 0.1 0.1% 0.00 0.00 5 0.1% 0.3 7.1% 0.04 0.27 6 0.0% 0.0 0.1% 0.00 0.00 7 0.1% 0.3 5.2% 0.03 0.20 8 0.0% 0.1 0.0% 0.00 0.00 9 0.1% 0.2 3.5% 0.02 0.13 10 0.0% 0.0 0.1% 0.00 0.00 11 0.0% 0.1 2.1% 0.01 0.08 12 0.0% 0.1 0.0% 0.00 0.00 13 0.0% 0.1 1.4% 0.01 0.05 14 0.0% 0.0 0.0% 0.00 0.00 15 0.1% 0.1 1.3% 0.01 0.05 16 0.0% 0.0 0.0% 0.00 0.00 17 0.0% 0.1 1.5% 0.01 0.06 18 0.0% 0.1 0.0% 0.00 0.00 19 0.1% 0.1 1.5% 0.01 0.06 20 0.0% 0.2 0.1% 0.00 0.01 21 0.1% 0.4 1.5% 0.01 0.05 22 0.0% 0.1 0.1% 0.00 0.00 23 0.0% 0.1 1.1% 0.01 0.05 24 0.0% 0.1 0.0% 0.00 0.00 25 0.0% 0.1 0.9% 0.01 0.04 26 0.0% 0.1 0.1% 0.00 0.00 27 0.1% 0.1 0.9% 0.01 0.04 28 0.0% 0.0 0.1% 0.00 0.00 29 0.0% 0.2 1.1% 0.01 0.04 30 0.0% 0.0 0.0% 0.00 0.00 31 0.1% 0.1 1.3% 0.01 0.05 32 0.1% 0.1 0.1% 0.00 0.00 33 0.1% 0.1 1.0% 0.01 0.04 34 0.1% 0.1 0.2% 0.00 0.00 35 0.1% 0.1 0.7% 0.00 0.03 36 0.0% 0.0 0.1% 0.00 0.00 37 0.1% 0.2 0.6% 0.00 0.03 38 0.0% 0.1 0.0% 0.00 0.00 39 0.1% 0.1 0.9% 0.01 0.03 40 0.0% 0.1 0.0% 0.00 0.00 41 0.1% 0.2 1.1% 0.01 0.04 42 0.0% 0.0 0.1% 0.00 0.00 43 0.1% 0.1 0.6% 0.00 0.02 44 0.0% 0.1 0.1% 0.00 0.00 45 0.0% 0.1 0.5% 0.00 0.02 46 0.0% 0.0 0.1% 0.00 0.00 47 0.0% 0.1 0.5% 0.00 0.02 48 0.0% 0.1 0.1% 0.00 0.00 49 0.0% 0.1 0.9% 0.01 0.03 50 0.0% 0.0 0.1% 0.00 0.00 Manufacturer:MAX GREEN Product type:mg-xfl-150w Temperature:25deg Verifier: Remark: Serial Num.: Humidity:65% Inspector: