ION CHROMATOGRAPHY SYSTEM S 150

Similar documents
Chemistry Instrumental Analysis Lecture 31. Chem 4631

ChromTech HPLC System

Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system

Dionex IonPac AS28-Fast-4µm column

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Suppression in anion chromatography. More sensitive analysis of anions and organic acids

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise.

861 Advanced Compact IC

Determination of trace anions in concentrated hydrofluoric acid

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

columns IonPac AS17-C Anion Exchange Column

columns IonPac AS22 Anion-Exchange Column

Thermo Scientific. Anion-Exchange Column

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

ION CHROMATOGRAPHY IC-3000 SERIES EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

HPLC Columns. HILICpak VT-50 2D MANUAL. Shodex HPLC Columns Europe, Middle East, Africa, Russia

anion-exchange column

columns IonPac AS18 Anion-Exchange Columns

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Expanded capabilities in ammonium and amine detection

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Ion chromatography. Ion chromatography

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

Biochemistry. Biochemical Techniques HPLC

Method Transfer between HPLC and UHPLC Instruments Equipment-related challenges and solutions

How do you explain HPLC? 2 AZURA Educational System for tomorrow s HPLC professionals

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Chromatography. Gas Chromatography

Cation Exchange HPLC Columns

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Chemistry 311: Instrumental Analysis Topic 4: Basic Chromatography. Chemistry 311: Instrumental Analysis Topic 4: Basic Chromatography

Cyanide and sulfide analysis using amperometric detection and Metrosep A Supp /4.0

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

HPLC. GRATE Chromatography Lab Course. Dr. Johannes Ranke. September 2003

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Fine Particles: Why We Care

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

RESOLUTION OENO 33/2004 DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION

Prominence for Ion Analysis

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

883 Basic IC plus. The smallest Metrohm ion chromatograph

ChromTech options for PAL systems

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers.

IC5000 Ion Chromatography System

HPLC Praktikum Skript

Theory of Ion Chromatography

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

Inline sample preparation for the determination of anions in sodium hydroxide

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

Setting the Standard for Advanced GPC/SEC Systems

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Thermo Scientific Dionex eluent suppressors for ion chromatography

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

IonPac Trace Cation Concentrator

Gas Chromatography (Chapter 2 and 3 in The essence of chromatography)

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Determination of Volatile Substances Proof of Food Adulteration

Air Monitoring. Semi-continuous determination of ambient air quality

Rapid Post-Blast Inorganic Explosive Analysis by Suppressed Ion Chromatography

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

Chapter content. Reference

637. Thiamethoxam. HPLC method

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Determination of Chloride, Fluoride, Bromide, Nitrate, Sulphate and Phosphate in Water Sample...

ProPac WCX-10 Columns

TP Analytical Chemistry II 7 th, December 2012

High-Performance Continuous Flow Chemistry Systems. Robust Accurate Flexible Safe

columns IonPac SCS 1 Silica Cation Separator

Anion Analysis of Ophthalmic Irrigation Solutions with the Shimadzu Prominence IC System Craig Young, PhD, Sr. Tech Support Specialist

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Instrumental Chemical Analysis

Figure 1. Structures for Vitamin B2 and Vitamin B1.

The Determination of Trace Anions in Concentrated Phosphoric Acid

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Coflore Agitated Cell Reactor

Deionized Water. Latest technology, highest quality, environmentally friendly. Water Technologies

ISEmax CAM40/CAS40. Technical Information

Determination of Trace Anions in Concentrated Hydrofluoric Acid

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

The determination of trace anions in concentrated phosphoric acid

Determination of trace anions in concentrated glycolic acid

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

Successfully Scaling and Transferring HPLC and UPLC Methods

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA

for IonPac AG11-HC IonPac AS11-HC

Transcription:

ION CHROMATOGRAPHY SYSTEM S 150 WATER ANALYSIS ENVIRONMENTAL ANALYSIS ANION & CATION ANALYSIS

ION CHROMATOGRAPHY IIon Chromatography is an analytical separation technique based on ionic interactions. Dissolved in a mobile phase, analyte ions (e.g. Chloride, Nitrate) compete with eluent ions (e.g. CO 3 2- / HCO 3- ) to be adsorbed on the charged surface of the stationary phase. Depending on the analytes electrical charge this technique is classified in cation and anion exchange. Extended Water Application (Anions) Sea Water (Anions) Rain Water (Anions) 2

IC Applications The field of application for Ion Chromatography is versatile. This technique found its way into routine and research applications: Parameters Anions Cations Organic acids Transition metals Amines Typical Applications Drinking water Tap water Sea water Waste water Rain water Ultra-trace determinition in electronic and power plants Quality control and analysis of impurities Elemental analysis (Wickbold & Schoeninger) Pharmaceuticals Urine analysis Urine (Anions) Water analysis for water treament plants Cooling water control for power plants Ground water analysis for quality control 3

ION CHROMATOGRAPHY SYSTEM S 150 Automatic IC System S 151 A The Automatic Ion Chromatograph S 151 A is a modular system which can be customized to any application needs. S 1130 Pump System The Sykam S 1130 HPLC Pump System is a very flexible and powerful HPLC solvent delivery system. The possible configurations include an Isocratic or Quaternary Gradient Pump. S 5300 Sample Injector The Sykam S 5300 Sample Injector System is a reliableand accurate HPLC autosampler with excellent reproducibility and linearity properties. Variable vial racks and adaptors for microtiter plates as well as a multitude of options make this system highly adaptable and suitable for any analytical application. 4

Manual IC System S 151 M The Manual Ion Chromatograph S 151 M is a low-cost modular system for low sample throughput. It can be upgarded to an automatic system at any time. Integrated Auto-Suppressor Optional Switching Valve Pressure Safety-Valve Pressure Sensor Integrated Column Oven Suppressor Membrane Pump Regeneration Valve 5

SYKAM AUTO-SUPPRESSOR The Sykam Auto-Suppressor is a robust chemical suppression system to increase the sensitivity of the anion analysis by reducing the background conductivity of the eluent. Trouble-Free Operation The Sykam Auto-Suppressor s membrane is protected by a Pressure Safety Valve, which opens when the pressure of the eluent flow is becoming to high. No annoying and expensive exchange of the membrane is needed! The membrane pump is maintenance free in its operation and the proper function is monitored by a built-in pressure sensor. The closed suppression circuit provides continuous operation over a long time without the need of regeneration solutions. The capacity of the Ion Exchange Buffer Chamber can be increased with an ENDURANCE upgrade. When the chamber s capacity is reached it can be easily regenerated without effort and need not be replaced. Maintenance-Free Membrane Pump Suppressor Pressure Sensor Pressure Safety Valve Regeneration Valve Suppression Chamber Ion Exchange Buffer Chamber optional: Ion Exchange ENDURANCE Upgrade 6

Working Principle Conductivity detection of anions in Ion Chromatography requires reduction of background conductivity to increase the detection sensitivity. The eluent buffer (e.g. Na 2 CO 3 / NaHCO 3 ) used to perform anion chromatography disturbs the Analyte measurement (e.g. Chloride, Nitrate, Sulfate). The Sykam Auto-Suppressor substitutes counter cations of the eluent (e.g. Na + ) with hydrogen ions. This transfers the eluent anion (e.g. CO 3 2- ) in a low conductive form and reduces the background conductivity. from Column to Flowcell The Analyte anions will not be interfered by this process. Their hydrogen forms (e.g. hydrochloric acid) are still dissociated. The Sykam Auto-Suppressor combines: an Ion exchange buffer chamber, filled with a durable and customer regenerative cation exchanger a transfer solution to transport hydrogen cations to the mobile phase and buffer cations to the resin and a membrane capillary that allows the transfer of hydrogen- and eluent cations 7

TECHNICAL SPECIFICATIONS S 150 Ion Chromatography Module Wetted Materials: PEEK, PPS, PTFE, Stainless Steel 1 Temperature Range: +30 C to +100 C 2 Temperature Accuracy: < 0.1 C Switching Valve: Measuring Range: Flowcell Volume: 0.76 µl Dimensions: (W x H x D) Power Supply: 1 Flowcell only 2 Temperature range at 20 C ambient S 1130 Pump System Wetted Materials: Flow Rate: Flow Accuracy: Flow Precision: Pressure Range: Pressure Pulsation: Compressibility Compensation: Vacuum Degassing: Dimensions: (W x H x D) Power Supply: optional: any S 6000 Series Valve 20 ns/cm up to 20,000 µs/cm 396 x 165 x 478 mm 100-250 ~V (47-63 Hz) PEEK, Teflon AF, PVDF, Ceramics, Sapphire Programmable Analytical: 0.001-10.000 ml/min ± 1.0 % 1.000 ml / min ± 0.1 % RSD 1.000 ml/min 0 40 MPa (0 6000 PSI) typical < 0.1 MPa or < 1.0 % user-adjustable for different solvents optional: < 20% dissolved gases remaining in water @ 1.000 ml/min 396 x 165 x 478 mm 100-250 ~V (47-63 Hz) S 5300 Sample Injector System Wetted Materials: PEEK, PPS, PVDF Sample Capacity: 120 (1.5 ml), 192 (microtiter plates) Injection Volume: Programmable 0.1-999.9 µl Sample Heating/Cooling: optional: +4 to +60 C Injection Precision: < 0.5 % Variable Volume Injection (10 µl; typically ~0.25 %) Linearity: Correlation Factor > 0.999 (10 µl injection volume, 500 µl Syringe) Carry Over: Dimensions: (W x H x D) Power Supply: < 0.05 % with wash program 396 x 275 x 478 mm 100-250 ~V (47-63 Hz) S 1130 Quaternary Gradient Pump System Wetted Materials: Flow Rate: Flow Accuracy: Flow Precision: Pressure Range: Pressure Pulsation: Compressibility Compensation: Vacuum Degassing: Gradient Range: Gradient Accuracy: < 0.50 % Gradient Mixing: PEEK, Teflon AF, PVDF, Ceramics, Sapphire Programmable Analytical: 0.001-10.000 ml/min ± 1.0 % 1.000 ml / min ± 0.1 % RSD 1.000 ml/min 0 40 MPa (0 6000 PSI) typical < 0.1 MPa or < 1.0 % user-adjustable for different solvents optional: < 20% dissolved gases remaining in water @ 1.000 ml/min 0.0 100.0 %, 4 channels Active Mixer Volume: adjustable: 100 500 µl Dimensions: (W x H x D) Power Supply: 396 x 165 x 478 mm 100-250 ~V (47-63 Hz) 8

ORDER INFORMATION Ion Chromatography System S 150 Catalog No Description Catalog No Description S003695 Manual IC System S 151-M - S 150 Ion Chromatography Module - with integrated Auto-Suppressor - S 1130 Isocratic Pump, PEEK, analytical - with integrated Vacuum Degasser - S 6120 Needle Injection Valve, 100 µl Sample Loop - Reagent Organizer S 600 w. 1x 1000ml Bottle S004161 Automatic IC System S 151-AG - S 150 Ion Chromatography Module - with integrated Auto-Suppressor - S 1130 Quaternary Gradient Pump, PEEK, analytical - with integrated 4-Channel Vacuum Degasser - S 5300 Sample Injector System, PEEK - S 600 Reagent Organizer w. 4x 1000ml Bottles Catalog No Description S004162 Manual IC System S 151-G - S 150 Ion Chromatography Module System Options: Catalog No Description - with integrated Auto-Suppressor - S 1130 Quaternary Gradient Pump, PEEK, analytical - with integrated 4-Channel Vacuum Degasser - S 6120 Needle Injection Valve, 100 µl Sample Loop - S 600 Reagent Organizer w. 4x 1000ml Bottles S003582 S003583 S003585 S003846 Auto-Suppressor Module Auto-Suppressor ENDURANCE update S 150 Detector Dual Channel update S 600 Reagent Organizer with Gas Regulator, 4x 1000 ml Bottles Catalog No Description Separation Columns* S004070 Automatic IC System S 151-A - S 150 Ion Chromatography Module - with integrated Auto-Suppressor - S 1130 Isocratic Pump, PEEK, analytical Catalog No S003586 S004193 Description Anion Separation Column ION-A01 (2.6 x 150 mm) Cation Separation Column ION-C01 (4.6 x 125 mm) - with integrated Vacuum Degasser - S 5300 Sample Injector System, PEEK * other columns are availabe on request - S 600 Reagent Organizer w. 1x 1000ml Bottle 9

SYKAM PRODUCTS S 500 Series HPLC Systems S 600 Series HPLC Systems S 433 Amino Acid Analyzer S 6000 Valve Series Sykam OEM Modules S 6800 LP Valve Series 10

NOTES: 11

Sykam GmbH Systeme & Komponenten analytischer Meßtechnik Gewerbering 15 86922 Eresing Germany Tel.: ++49 (8193) 93 82-0 FAX: ++49 (8193) 93 82-20 EMail: info@sykam.com Web: http://www.sykam.com