Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Similar documents
Exploring Mixed-Mode Chromatography: Column Chemistry, Properties, and Applications

A Platform Method for Pharmaceutical Counterion Analysis by HPLC

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

HILIC Method Development in a Few Simple Steps

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Monitoring Protein PEGylation with Ion Exchange Chromatography

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

of mass spectrometry

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

MetWorks Metabolite Identification Software

Metoprolol and Select Impurities Analysis Using a Hydrophilic Interaction Chromatography Method with Combined UV and Charged Aerosol Detection

Pharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Semi-Targeted Screening of Pharmaceutically- Related Contaminants in the Thames Tideway using LC-HRMS

Thermo Scientific. Anion-Exchange Column

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Charged Aerosol Detection and Evaporative Light Scattering Detection Fundamental Differences Affecting Analytical Performance

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

IN QUALITATIVE ANALYSIS,

Introduction to Fourier Transform Infrared Spectroscopy

Utility of the Charge Detector in Ion Chromatography Applications

Quantitation of Surfactants in Samples by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

Fast, Effective XPS Point Analysis of Metal Components

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Introduction to Fourier Transform Infrared Spectroscopy

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Quantitation and Characterization of Copper and Nickel Plating Bath Additives by Liquid Chromatography

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Enhancement of Linearity and Response in Charged Aerosol Detection

Analytical Methods to Qualify and Quantify PEG and PEGylated Biopharmaceuticals

New Developments in Surfactant Analysis Using HPLC

Direct Analysis using Paper-Spray Mass Spectrometry: Method Development for the Rapid Screening of Drugs of Abuse for Forensic Toxicology

Key Words Q Exactive Focus, Orbitrap, veterinary drugs, small molecule HRAM quantitation, small molecule HRAM screening, UHPLC, vdia

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

High-Field Orbitrap Creating new possibilities

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Quantitation and Characterization of Copper Plating Bath Additives by Liquid Chromatography with Charged Aerosol Detection

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

[ Care and Use Manual ]

Analysis - HPLC A.136. Primesep 5 µm columns B.136

for XPS surface analysis

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Advances in Sample Preparation for Accelerated Solvent Extraction

Expanded capabilities in ammonium and amine detection

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

Thermo Scientific HyperSep Dispersive SPE Products. Efficient sample preparation and clean-up using the QuEChERS Method

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Thermo Scientific Acclaim. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Simultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by HPLC Using a Mixed-Mode Weak Anion-Exchange Column

Key Words Nanoparticles, spicp-ms, ICP-MS, Qtegra ISDS Software, AF4-ICP-MS

Direct Analysis of Surfactants using HPLC with Charged Aerosol Detection

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Validation of GC-MS/MS for Detection and Confirmation of Low-Level Dioxins

Improving Intact Antibody Characterization by Orbitrap Mass Spectrometry

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Transcription:

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications Xiaodong Liu and Christopher Pohl; Thermo Fisher Scientific, Sunnyvale, CA

Overview Review mixed-mode column technology Demonstration of challenging applications using mixed-mode chromatography Introduction Although reversed-phase columns (e.g. C18) are most commonly used in broad range of applications, they often fail to retain highly hydrophilic molecules (e.g. counterions), and offer limited selectivities. Mixed-mode chromatography provides a viable solution to these challenges by combining both reversed phase and ion-exchange retention mechanisms. One major advantage of this approach is that column selectivity can easily be modified for optimal selectivity by adjusting mobile phase ionic strength, ph and/or organic solvent concentration. As a result, not only is the selectivity of a mixedmode column complementary to that of reversed-phase columns, but it also allows for the development of multiple complementary selectivities on the same column under different appropriate conditions. Mixed-mode chromatography is well-suited to retaining ionic analytes, whether hydrophobic (e.g. Naproxen) or hydrophilic (e.g. Na+ and Cl- ions), and requires no ion-pairing agents in the method, significantly improving the MS compatibility. Most importantly, mixed-mode chromatography column chemistry can be customized to a desired selectivity during stationary phase design. This presentation will give an overview on the latest mixed-mode chromatography technology, describe unique chromatographic properties of mixed-mode columns, and discuss analytical challenges that have been addressed by mixed-mode chromatography approach. Examples include determinate on of pharmaceutical counterions, simultaneous separation of anionic, cationic, nonoionic and amphoteric surfactants, high resolution and fast LC-MS analysis of paraquat and diquat, and analysis of glycans from proteins and human IgG. Mixed-Mode Chromatography Definition Hydrophobic (or hydrophilic) interaction + ion-exchange interaction Benefits Adjustable selectivity for optimal separation Simplified mobile phase (no need for ion-pairing reagents) Simultaneous separation of different types of analytes Types Anion-exchange/reversed-phase (AEX/RP) Cation-exchange/reversed-phase (CEX/RP) Anion-exchange/cation-exchange/reversed-phase (AEX/CEX/RP) AEX/HILIC CEX/HILIC AEX/CEX/HILIC FIGURE 1. Reversed-Phase/Ion-Exchange Bimodal Phases. 2 Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

FIGURE 2. Reversed-Phase/Anion-Exchange/Cation-Exchange Trimodal Phases. Key Applications Pharmaceutical Counterion Analysis by Acclaim Trinity P1 & Acclaim Trinity P2 Salt formation is important in drug development to improve biopharmaceutical and physicochemical properties of the drug. Approximately 50% of all drugs are formulated as salt forms. Assays for API and counterions are usually analyzed separately using different methods, different separation columns, and different instruments. Thermo Scientific Acclaim Trinity P1 and P2 columns are designed for the simultaneous separation of pharmaceuticals and their counterions. These columns are based on nanopolymer silica hybrid (NSH) technology, a unique morphology which provides exceptional resolution of both anions and cations within the same analysis and in a reasonable amount of time. The Acclaim Trinity P1 column is designed for monovalent counterion separation and the Acclaim Trinity P2 is designed for mono- and multivalent counterion separations. FIGURE 3. Separation of Monovalent Counterions. Thermo Scientifi c Poster Note PITTCON PN21137-EN 0215S 3

FIGURE 4. Ion (anions & cations) Screening. Surfactant Analysis by Acclaim Surfactant Plus Surfactants are widely used in consumer products, agricultural, pharmaceutical, biopharmaceuticals and chemical markets, in products as diverse as pesticides, detergent powders, petroleum products, cosmetics, and pharmaceuticals. Their separation and identification can be challenging due both to the diversity of surfactants and complexity of the sample matrix. Although many HPLC columns are available and have been used for the analysis of surfactant formulations, none of these columns are capable of separating anionic, nonionic, cationic and amphoteric surfactants in a single analysis. The Thermo Scientific Acclaim Surfactant Plus columns are designed for separating a wide variety of surfactants, including anionic, cationic, nonionic, and amphoteric surfactants. FIGURE 5. Separation of Cationic, Nonionic, Amphoteric & Anionic Surfactants. 4 Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Diquat and Paraquat Analysis by Acclaim Trinity Q1 Paraquat (1,1 -dimethyl-4,4 -bipyridylium dichloride, C 12 H 14 N 2 Cl 2 ) and Diquat (1,1 - ethylene-2,2 -bipyridilium dibromide, C 12 H 12 N 2 Br 2 ) are non-selective and nonsystematic contact herbicides widely used in agriculture to control broadleaf and grassy weeds. However they are toxic and either compound can have serious effects as they can alter reduction-oxidation activities in biological systems. The separation of these highly charged dual quaternary amines is challenging because of their ionic nature. The Acclaim Trinity Q1 is designed for fast separation of Paraquat and Diquat with both UV and MS detections. The benefits include excellent resolution, good peak shape, high throughput, MS compatibility (no need for on-pairing reagent) and ease of use. FIGURE 6. LC-MS-MS: Paraquat and Diquat at 10 ppb. Glycan Analysis by GlycanPac AXH and GlycanPac AXR Glycans are oligosaccharides and polysaccharides found on proteins and cell surfaces. They play fundamental roles in cellular function by creating a fingerprint tag for the protein they are bound to. Glycans are often key biomarkers for disease states such as cancer. The structures of glycans are highly complex because of the branching of the chains and post-translational modifications. Various HPLC separation modes have been used for glycan analysis, such as hydrophilic interaction (HILIC), ion-exchange (IEX) and reversed-phase (RP) chromatography. Because glycans are highly hydrophilic and polar substances, they are commonly separated on an amide HILIC column which separates glycans mainly by hydrogen bonding, resulting in size and composition-based separation. However, one limitation of this approach is that glycan identification and quantitation become highly challenging because glycans of different charge states are intermingled in the separation envelope. The Thermo Scientific GlycanPac AXR-1 and GlycanPac AXH-1 columns are high-performance, silica-based HPLC columns designed for high-resolution glycan separations. They provide industry-leading resolution with unique selectivities for biologically important glycans, either labeled or native, using fluorescence and/or mass spectrometry (MS) detection. Both columns separate glycans by charge and size. Additionally the GlycanPac AXR-1 columns are superior for separating glycan isomers. The GlycanPac AXH-1 columns are also used for fast, accurate, and simple quantification of glycans by charge. Thermo Scientifi c Poster Note PITTCON PN21137-EN 0215S 5

FIGURE 7. 2-AB N-Glycan from Bovine Fetuin (GlycanPac vs. Amide HILIC). Conclusion Mixed-mode columns offer advantages over other separation columns through Excellent performance: selectivity, resolution and retention Flexibility in method development Reduced cost Mixed-mode column technology provide versatile platform to a variety of application-specific columns There is a family of Thermo Scientific mixed-mode columns that facilitate instrument pull-through Acknowledgements (if necessary) We would like to thank Dr. Mark Tracy, Mr. Yoginder Singh, Dr. Udayanath Aich and Mr. Andrey Korolev for their contributions. www.thermoscientific.com/chromatography 2015 Thermo Fisher Scientifi c Inc. All rights reserved. ISO is a trademark of the International Standards Organization. All other trademarks are the property of Thermo Fisher Scientifi c and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientifi c products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifi cations, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Thermo Fisher Scientifi c, Sunnyvale, CA USA is ISO 9001 Certifi ed. Africa +43 1 333 50 34 0 Australia +61 3 9757 4300 Austria +43 810 282 206 Belgium +32 53 73 42 41 Brazil +55 11 3731 5140 Canada +1 800 530 8447 China 800 810 5118 (free call domestic) 400 650 5118 PN21137-EN 0215S Denmark +45 70 23 62 60 Europe-Other +43 1 333 50 34 0 Finland +358 9 3291 0200 France +33 1 60 92 48 00 Germany +49 6103 408 1014 India +91 22 6742 9494 Italy +39 02 950 591 Japan +81 6 6885 1213 Korea +82 2 3420 8600 Latin America +1 561 688 8700 Middle East +43 1 333 50 34 0 Netherlands +31 76 579 55 55 New Zealand +64 9 980 6700 Norway +46 8 556 468 00 Russia/CIS +43 1 333 50 34 0 Singapore +65 6289 1190 Sweden +46 8 556 468 00 Switzerland +41 61 716 77 00 Taiwan +886 2 8751 6655 UK/Ireland +44 1442 233555 USA +1 800 532 4752