A Professional Manufacturer UV / VIS Spectrophotometer EMCLAB Instruments GmbH
EMCLAB Instruments GmbH Bismarckstrasse 120 47057 Duisburg Germany Phone: +49 203 3064042 Fax: +49 203 3064044 E-mail: info@emc-lab.de Web: www.emc-lab.de Contact: Mrs. Anke Rehmann, Managing Director 2 E-Mail: info@emc-lab.de www.emc-lab.de
EMCLAB Spectrophotometer Selection guide Model Optical System Wavelength Range Bandwidth EMC-11D-V Single Beam 325-1000 nm 4 nm EMC-11-UV Single Beam 200-1000 nm 4 nm EMC-16PC-V Single Beam 320-1100 nm 4 nm EMC-16PC-UV Single Beam 190-1100 nm 4 nm EMC-18PC-UV Single Beam 190-1100 nm 2 nm EMC-31PC-UV Single Beam 190-1100 nm 2 nm EMC-32PCS-UV Single Beam Scanning function 190-1100 nm 0.5/1/2/4/5 nm EMC-61PC-UV Double Beam 190-1100 nm 1.8 nm EMC-61PCS-UV Double Beam Scanning function 190-1100 nm 0.5/1/2/4/5 nm EMC-NANO-UV Single Beam 0.2 ~ 2.0 µl 190-1100 nm 4 nm PC means with PC control software Standard central beam height: 15 mm Basic software included in: Professional software optional for: Analyst software included in: EMC-11D-V, EMC-11-UV, EMC-1x series EMC-3 series, EMC-6 series, EMC-NANO-UV EMCLAB Spectrophotometers are tested with DAkkS (German body of accreditation) certified UV/VIS Reference Materials NIST traceable: Photometric Accuracy Wavelength Accuracy Spectral Resolution Stray Light All EMCLAB Spectrophotometers are supplied with a EMCLAB Works Calibration Certificate. TRACEABLE E-Mail: info@emc-lab.de www.emc-lab.de 3
Visible Spectrophotometer EMC-11D-V EMC-11D-V is the only model of manually setting wavelength. High quality components ensure excellent performance. It is ideal suited for high schools and colleges for general analysis and experiments. Features: Large LCD screen (128*64) Auto Zero and Blank Parallel port for printer Large sample compartment for different holders Inclusive PC Basic software based on Windows Following functions: I. Quantitative II. Kinetics III. Photometry High quality silicon photodiode detector Model Wavelength Range Spectral Bandwidth Optical System Wavelength Accuracy Wavelength Repeatability Photometric Accuracy Photometric Range Stray Light Stability Display Photometric Mode Detector Standard Cell Holder Sample Compartment Light Source Output Power Requirement Dimensions (LxWxH) Weight EMC-11D-V 325-1000 nm 4 nm Single Beam, grating 1200 lines/mm ±2 nm 1 nm ±0.5 % T or ±0.003A@1A 0-200 % T, -0.3-3A, 0-1999 Conc 0.3 % T ±0.004A/h @500 nm 128*64 LCD T, A, C, F Silicon Photodiode 4-position 10 mm cell changer Standard 10 mm path length cuvette Tungsten lamp USB Port & Parallel Port (Printer) AC 85V~265V 50/60 Hz 440 x 340 x 200 mm 8 kg 4 E-Mail: info@emc-lab.de www.emc-lab.de
UV / VIS Spectrophotometer EMC-11-UV EMC-11-UV spectrophotometer is the ideal instrument for education and QC laboratories. On a large LCD screen you can get a standard curve. It is ideal suited for high schools colleges universities and enterprises for general quantitative analysis and experiments. Features: Large LCD screen (128*64) Self-check system Display of total 50 groups of data, 3 groups per screen. Display of standard curve and the curve equation Save the test results. Total groups of data and 200 standard curves can be saved Data can be restored after a sudden power cut Auto setting wavelength Tungsten lamp & Deuterium lamp can be turned on/off individually Large sample compartment for different holders Inclusive PC Basic software based on Windows Following functions: I. Quantitative II. Kinetics III. Photometry IQ / OQ ready Model Wavelength Range Spectral Bandwidth Optical System Wavelength Accuracy Wavelength Repeatability Photometric Accuracy Photometric Range Stray Light Stability Detector Standard Cell Holder Sample Compartment Light Source Output Power Requirement Dimensions (LxWxH) Weight EMC-11UV 200-1000 nm 4 nm Single Beam, grating 1200 lines/mm ±2 nm 1 nm ±0.5 % T or ±0.003A@1A 0-200 % T, -0.3-3A, 0-9999 Conc. 0.2 % T ±0.002A/h @500 nm Silicon Photodiode 4-position 10 mm cell changer Standard 10 mm path length cuvette Tungsten & Deuterium lamp USB Port & Parallel Port (Printer) AC 110/220V 50/60 Hz 480 x 360 x 220 mm 14 kg E-Mail: info@emc-lab.de www.emc-lab.de 5
UV / VIS Spectrophotometer EMC-16/18 series EMC-16/18 series are user-friendly instruments and secure perfect measurement results. The EMC-16/18 series offers the individual all-rounder for routine and special analysis. Its stray light is only 0.05%T. The on-board software makes the instruments flexible and comprehensive. The software offers functions: Quantitative Test, Kinetics, Photometry and System Utilities. Features: Large LCD screen (128*64) Self-check system Save the test results. 200 groups of data and 200 standard curves Data can be restored after a sudden power cut Auto setting wavelength Tungsten lamp & Deuterium lamp can be turned on/off individually Large sample compartment for different holders The optional Professional PC software based on Windows provides more functions: I. Quantitative II. Kinetics III. Wavelength Scan IV. Multi Wavelength V. DNA/Protein IQ / OQ ready Model EMC-16PC-V EMC-16PC-UV EMC-18PC-UV Wavelength Range 320-1100 nm 190-1100 nm Spectral Bandwidth 4 nm 2 nm Optical System Single Beam, grating 1200 lines/mm Wavelength Accuracy ±0.5 nm Wavelength Repeatability 0.3 nm Photometric Accuracy ±0.5 % T or ±0.003A@1A Photometric Range 0-200 % T, -0.3-3A, 0-9999 Conc. Stray Light 0.05 % T@360 nm 0.05 % T@260, 360 nm Stability ±0.002A/h @500 nm Detector Silicon Photodiode Display Graphic LCD (128+64 dots) Keyboard 22 Membrane keypad Standard Cell Holder 4-position 10 mm cell changer Sample Compartment Standard 10 mm path length cuvette Light Source Tungsten lamp Tungsten & Deuterium lamp Output USB Port & Parallel Port (Printer) Power Requirement AC 110/220V 50/60 Hz Dimensions (LxWxH) 490 x 370 x 220 mm Weight 12 kg 14 kg 6 E-Mail: info@emc-lab.de www.emc-lab.de
UV / VIS Spectrophotometer EMC-16/18 series On-board Software Main Menu Basic Mode Quantitative Kinetics Utility Basic Mode For measurements of Absorbance Transmittance or Concentration Display and save 200 groups of data 5 groups per screen Quantitative 2.1 Standard Curve A standard curve can be established with up to 9 standard samples. The curve and its equation will be displayed on the screen simultaneously. Save total 200 curves 2.2 Coefficient Method If the coefficient k*a + b in the formula C=k*a + b is known, you can input them directly. Then measure your unknown samples. Kinetics For time course scanning or reaction rate calculation. Absorbance vs time graphs will be shown on the display in real time. Process of up to 1000 data. System Utilities Lamp management Time & data Dark current Calibrate wavelength Default system Other system functions E-Mail: info@emc-lab.de www.emc-lab.de 7
UV / VIS Spectrophotometer EMC-3 series The EMC-3 series are advanced single beam spectrophotometers. They are user-friendly and secure perfect measurement results in the range of 190 to 1100 nm. They are ideal suited for routine and special applications in chemical, pharmaceutical, biochemical and clinical laboratories. The on-board software makes the instruments flexible and comprehensive. The software offers functions: Quantitative Test, Kinetics, Wavelength scan, Multi-Wavelength scan, Photometry and DNA/Protein analysis. The included Analyst PC software based on Microsoft Windows makes the instruments versatile and suitable in all areas of applications. Features: Large LCD screen (320*240) Self-check system Fixed or variable slits (Bandwidth) Keypad with alpha-numeric entry for file names and units Tungsten lamp & Deuterium lamp can be turned on/off individually Status of the lamps are monitored Memory 32K Data can be saved by USB memory stick Online software upgrading via internet helps to keep it updated Inclusive Analyst PC software based on Windows which provides more functions for complete control of the spectrophotometer: I. Quantitative II. Kinetics III. Wavelength Scan IV. Multi Wavelength V. DNA/Protein VI. Photometric VII. System Utility IQ / OQ ready Model EMC-31PC-UV EMC-32PCS-UV Wavelength Range 190-1100 nm Spectral Bandwidth 2 nm 0.5/1/2/4/5 nm Optical System Single Beam, grating 1200 lines/mm Wavelength Accuracy ±0.5 nm ±0.3 nm Wavelength Repeatability 0.3 nm 0.2 nm Scan Speed Hi, MED, LOW, MAX. 3000 nm/min Photometric Accuracy ±0.5 % T or ±0.005A@1A Photometric Range 0-200 % T, -0.3-3A, 0-9999Conc. Stray Light 0.05 % T@220, 340 nm Stability ±0.002A/h @500 nm Detector Silicon Photodiode Display 5 inches LCD (320*240 dots) Baseline Flatness ±0.002A (200-1000 nm) Standard Cell Holder 4-position 10 mm cell changer Sample Compartment Standard 10 mm path length cuvette Light Source Tungsten & Deuterium lamp (Pre-aligned) USB type A port for USB memory device (Right side) Output USB type B port for optional computer connectivity (Back) Parallel port for printer Power Requirement AC 110/220V 50/60 Hz Dimensions (LxWxH) 490 x 370 x 220 mm 589 x 428 x 240 mm Weight 14 kg 20 kg 8 E-Mail: info@emc-lab.de www.emc-lab.de
UV / VIS Spectrophotometer EMC-6 series The EMC-6 series are advanced double beam spectrophotometers. The two detectors measure sample and reference respectively and simultaneous for optimizing measurement accuracy. They are user-friendly and secure perfect measurement results in the range of 190 to 1100 nm. They are ideal suited for routine and special applications in chemical, pharmaceutical, biochemical and clinical laboratories. The on-board software makes the instruments flexible and comprehensive. The software offers functions: Quantitative Test, Kinetics, Wavelength scan, Multi-Wavelength scan, Photometry and DNA/Protein analysis. The included Analyst PC software based on Microsoft Windows makes the instruments versatile suitable in all areas of applications. Features: Large LCD screen (320*240) Self-Check system Fixed or variable slits (Bandwidth) Keypad with alpha-numeric entry for file names and units Tungsten lamp & Deuterium lamp can be turned on/off individually Status of the lamps are monitored Memory 32K Data can be saved by USB memory stick Online software upgrading via internet helps to keep it updated Inclusive Analyst PC software based on Windows which provides more functions for complete control of the spectrophotometer: I. Quantitative II. Kinetics III. Wavelength Scan IV. Multi Wavelength V. DNA/Protein VI. Photometric VII. System Utility IQ / OQ ready Model EMC-61PC-UV EMC-61PCS-UV Wavelength Range 190-1100 nm Spectral Bandwidth 1.8 nm 0.5/1/2/4/5 nm Optical System Double Beam, grating 1200 lines/mm Wavelength Accuracy ±0.3 nm Wavelength Repeatability 0.2 nm Scan Speed Hi, MED, LOW, MAX. 3000 nm/min Photometric Accuracy ±0.5 % T or ±0.005A@1A Photometric Range 0-200 % T, -0.3-3A Stray Light 0.05 % T@220, 340 nm Stability ±0.001A/h @500 nm Detector Silicon Photodiode Display 5 inches LCD (320*240 dots) Baseline Flatness ±0.001A Standard Cell Holder Standard 10 mm single cell holder (2 pcs.) Sample Compartment Standard 10 mm path length cuvette Light Source Tungsten & Deuterium lamp (Pre-aligned) USB type A port for USB memory device (Right side) Output USB type B port for optional computer connectivity (Back) Parallel port for printer Power Requirement AC 110/220V 50/60 Hz Dimensions (LxWxH) 589 x 428 x 240 mm Weight 22 kg E-Mail: info@emc-lab.de www.emc-lab.de 9
NANO Spectrophotometer EMC-NANO-UV EMC-NANO-UV the new model for fast, easy, accurate and economic measuring of minimum volumes of 0.2 µl to 2 µl with high quality components ensures excellent performance. It is used in DNA, RNA, PCR, protein analyzing within the range from UV to VIS range. Features: Compact instrument with on-board software as well as Analyst PC software Multifunctional EMC-cell holder for Nano volume and standard cuvette optical path length 10 mm Large LCD screen (320*240) 0.2-2.0 µl sample volume for DNA, RNA, PCR, protein One step one movement drop close turn and measure Wavelength range from 190-1100 nm Tungsten lamp & Deuterium lamp can be turned on/off individually Data can be saved by USB memory stick IQ / OQ ready The instrument comes standard with Windows based Analyst PC software High quality silicon photodiode detector ensures high accuracy and precision The special multifunctional cell holder for Nano volume and standard cuvette optical path length 10 mm: Simple-to-use Multifunctional EMC-cell holder 2 in 1 Horizontal light path high precision, no loss of energy Model Wavelength Range Spectral Bandwidth Optical System Wavelength Accuracy Wavelength Repeatability Photometric Accuracy Photometric Range Stray Light Stability Detector Multifunctional Cell Holder Scan Speed Light Source Output Power Requirement Dimensions (LxWxH) Weight EMC-NANO-UV 190-1100 nm 4 nm Single Beam, grating 1200 lines/mm ±0.5 nm 0.3 nm ±0.5 % T or ±0.004A@1A 0-200 % T, -0.3-3A, 0-9999 Conc. 0.05 % T@220, 340 nm ±0.0008A/h @500 nm Silicon Photodiode 0.2-2.0 µl volume & Standard cuvette 10 mm path length Hi, MED, LOW MAX: 3000nm/min Tungsten & Deuterium lamp USB type A port for USB memory device (Right side) USB type B port for optional computer connectivity (Back) Parallel port for printer AC 110/220V 50/60 Hz 490 x 370 x 220 mm 14 kg Recommended Pipette Article No. Volume (µl) Increment (µl) R/A% (CV%) Tip EMC-5720005 0.1-2.5 0.05 4.0 (2.0) 1 10 E-Mail: info@emc-lab.de www.emc-lab.de
UV / VIS Spectrophotometer EMC-3, EMC-6 & NANO On-board Software All methods are included as built-in standard; this eliminates the need of software. Online software update via internet. The on-board software includes functions such as: Photometry, Quantitative, Kinetics, Wavelength Scan, Multi-wavelength Test and System Utilities Standard Curve Up to 10 standard solutions may be used to establish calibration equation curve. There is a choice of four methods for fitting curve through the calibration points: linear fit, Linear fit through zero, square fit and cubic fit. Wavelength Scan The wavelength scan intervals are 0.1, 0.2, 0.5, 1, 2, 5 nm and High, Medium and Low scan speeds are available. Scan speeds vary from 100 to 3000 nm/min. Wavelengths are scanned for high to low so that the instrument stand-by at high wavelength. This minimizes the degradation of UV sensitive samples. Precise control of filter and lamp changes means that their effects are not seen on the final scan. Post-run manipulation includes re-scaling axes, curve tracking and peak picking. Kinetics This mode may be used for scanning time course or reacting rate calculations. Abs. VS time graphs is displayed on the screen in real time. Wait time and measurement time up to 12 hours may be entered with time intervals of 0.5, 1, 2.5, 10, 30 seconds and 1 min. Post-run manipulation includes re-scaling, curve tracking and selection of the part of the curve required for the rate calculation. Rate is calculated using a linear regression algorithm before multiplying by the entered factor. Multi-Wavelength Up to 10 wavelengths may be entered, allowing the measurement of multiple wavelengths on a series of samples. DNA/Protein Test Concentration and DNA purity are calculated by absorbance ratios 260 nm/280 nm or 260 nm/230 nm with optional subtracted absorbance at 320 nm DNA concentration = 62.9*A 260-36.0*A 280 or 49.1*A 260-3.48*A 230 Protein concentration = 1552*A 260-757.3*A 280 or 183*A 260-75.8*A 230 Other wavelengths and factors may be entered. E-Mail: info@emc-lab.de www.emc-lab.de 11
Spectrophotometer Software Professional Software for EMC-16/18 series Professional application software is based Microsoft Windows, the instrument can be controlled by PC software through built-in USB communication port, which makes the UV/VIS series with more functions and easy to control. Quantitative Use up to 20 standards to establish standard curve. Three methods for fitting a curve: 1. Linear fit 2. Linear through zero 3. Square fit Kinetics The Kinetics mode may be used for scanning time course or reacting rate calculations. Abs. VS time graphs is displayed. Wavelength Scan Automatically records peaks and valleys. The quantity of the curves stored is unlimited. Post-run manipulation and processing includes 1. Re-scaling axes, curve 2. Smoothing, combination, zooming, overlap 3. 1 st to 4 th derivative Multi-wavelength Test You can set up to 20 wavelengths to measure a sample DNA/Protein Test Optional two formulas: DNA concentration = 62.9*A 260-36.0*A 280 or 49.1*A 260-75.8*A 230 You can also enter other wavelengths and factors to calculate. 12 E-Mail: info@emc-lab.de www.emc-lab.de
Spectrophotometer Software Analyst Software for EMC-3 series, EMC-6 series & EMC-NANO The PC application Analyst software takes the features of the stand-alone version plus more powerful data processing, expanded data collecting, and storage capability. It comes standard with EMC-3 and EMC-6 series and EMC-NANO-UV. The PC application software offers: 1. Photometric Mode 2. Quantitative Test (Standard curve) 3. Wavelength Scan 4. Kinetics 5. DNA/Protein 6. Multi-Wavelength 7. System Utility Quantitative Test Use up to 20 standards to establish standard curve. Four methods for fitting a curve: 1. Linear fit 2. Linear through zero 3. Square fit 4. Cubic fit Wavelength Scan Automatically records peaks and valleys. The quantity of channels is unlimited. You can simultaneously store as many as desired. Post-run manipulation and processing includes: 1. Re-scaling axes, curve 2. Smoothing, combination, zooming, overlap 3. 1 st to 4 th derivative Kinetics (Abs. VS time) The Kinetics mode may be used for scanning time course or reacting rate calculations. Abs. VS time graphs are displayed on the screen in real time. Wait time, measurement time and time intervals may be entered. Post-run manipulation includes re-scaling, curve tracking and selection of the part of the curve required for the rate calculation. Rate is calculated using a linear regression algorithm before multiplying by the entered factor. E-Mail: info@emc-lab.de www.emc-lab.de 13
Spectrophotometer Software DNA/Protein Test Concentration and DNA purity are quickly and easily calculated. Absorbance ratios 260 nm/280 nm with optional subtracted absorbance at 320 nm DNA concentration = 62.9*A 260-36.0*A 280 Protein concentration = 1552*A 260-757.3*A 280 Other wavelengths and factors may be entered. Multi-wavelength Up to 20 wavelengths can be selected and multiple samples can be measured. (auto cell changer is required to run multiple samples automatically) 14 E-Mail: info@emc-lab.de www.emc-lab.de
Spectrophotometer Cuvettes Cuvettes glass and quartz glass Standard Art. No. Premium Art. No. Cuvette Optical path length (mm) Volume (µl) Outside dim (H x W x D mm) Macro cuvettes: EMC-S0001 EMC-100OS Cuvette square glass 10 3500 45 x 12,5 x 12,5 EMC-S0002 EMC-105OS Cuvette square glass 50 17500 45 x 12,5 x 52,5 EMC-S0003 EMC-100QS Cuvette square quartz glass 10 3500 45 x 12,5 x 12,5 EMC-S0004 EMC-105QS Cuvette square quartz glass 50 17500 45 x 12,5 x 52,5 Semi-Micro cuvettes: - EMC-108OS Cuvette glass 10 1000 45 x 12,5 x 12,5 Cuvette glass EMC-S0005 - (black side walls and base) 10 1000 45 x 12,5 x 12,5 - EMC-108QS Cuvette quartz glass 10 1000 45 x 12,5 x 12,5 Cuvette quartz glass EMC-S0011 EMC-108QSB (black side walls and base) 10 1000 45 x 12,5 x 12,5 Micro cuvettes: EMC-S0007 EMC-104OSB Cuvette glass (black side walls and base) 10 700 45 x 12,5 x 12,5 - EMC-104QS Cuvette quartz glass 10 700 45 x 12,5 x 12,5 Cuvette quartz glass EMC-S0013 EMC-104QSB (black side walls and base) 10 700 45 x 12,5 x 12,5 - EMC-108QSM Cuvette quartz glass 10 500 45 x 12,5 x 12,5 - EMC-108QSMB Cuvette quartz glass (black side walls and base) 10 500 45 x 12,5 x 12,5 EMC-S0006 - Cuvette glass (black side walls and base) 10 350 45 x 12,5 x 12,5 EMC-S0012 - Cuvette quartz glass (black side walls and base) 10 350 45 x 12,5 x 12,5 - EMC-108QSM15 Cuvette quartz glass averture 5 x 2 mm 10 100 45 x 12,5 x 12,5 Flow-through cuvettes: EMC-S0009 - Cuvette glass 10 480 45 x 12,5 x 12,5 - EMC-175OS Cuvette glass 10 750 45 x 12,5 x 12,5 EMC-S0010 - Cuvette quartz glass 10 480 45 x 12,5 x 12,5 - EMC-175QS Cuvette quartz glass 10 750 45 x 12,5 x 12,5 Standard optical glass: 340 2500 nm Premium special optical glass: 320 2500 nm Standard quartz glass: 190 2500 nm Premium quartz glass: 200 2500 nm E-Mail: info@emc-lab.de www.emc-lab.de 15
Spectrophotometer Disposable Cuvettes Disposable Cuvettes UV/VIS New plastic coupled with modern methods of production allow photometric measurement well into the UV range. Ultra-precision molds with several cavities one per cuvette are used for producing EMC-disposable cuvettes under controlled room conditions. Thus, in any one injection molding run several cuvettes are produced simultaneously. In order to prevent deviations in extinction coefficient values from occurring in any one run due to increased stray light, the cuvettes are automatically sorted according to their numbered cavities of origin. Each package contains only cuvettes that have been produced in any one cavity. The corresponding cavity number is noted on each package. Thus, even for extensive analyses, the same cuvettes can be used. Very low variation of extinction values Excellent optical transmission range Cavity-sorted production Optical path length 10 mm Outside dim 45 x 12,5 x 12,5 mm Cuvettes supplied in practical styrofoam racks Stoppers supplied in a plastic bag Art. No. Cuvette Volume (ml) Packaging (pcs.) Wavelength (nm) Macro cuvettes: EMC-S0028 PS (glass-clear Polystyrene) 4,0 10 x 100 340 900 EMC-S0030 UV 4,0 1 x 100 220 900 EMC-S0031 Solvent resistant against polar solvents 4,0 1 x 100 220 900 EMC-S0032 PMMA (Polymethylmethacrylate) 4,0 10 x 100 300 900 Semi-Micro cuvettes: EMC-S0029 PS (glass-clear Polystyrene) 1,6 10 x 100 340 900 EMC-S0033 UV 1,6 1 x 100 220 900 EMC-S0034 Solvent resistant against polar solvents 1,6 1 x 100 220 900 EMC-S0035 PMMA (Polymethylmethacrylate) 1,6 10 x 100 300 900 Stoppers: EMC-S0036 PP (Polypropylene) 1 x 1000 16 E-Mail: info@emc-lab.de www.emc-lab.de
Spectrophotometer Reference Materials UV/VIS certified Reference Materials EMC-SET-667UV EMC-SET-666 TRACEABLE The UV/VIS certified reference materials enable the user to check quickly and easily its measurements results with the quality standard of the spectrophotometer. The measurements results are internationally comparable. The reference materials are DAkkS (German body of accreditation) certified traceable to primary references of NIST (National Institute of Standards and Technology) and in accordance with the most important Pharmacopoeias (EP, DAB; USP). UV/VIS certified reference materials for testing: Wavelength accuracy Photometric accuracy Stray light Spectral resolution Art. No. Filters Wavelength (nm) Set liquid filter for testing acc. to European Pharmacopeias: EMC-SET-667UV Potassium chloride in pure water Pure water reference filter) Toluene in n-hexane n-hexane (reference filter) 60 mg Potassium dichromate in HClO 4 (0.75 Abs.) 600 mg Potassium dichromate in HClO 4 (1.0 Abs.) Perchlorid acid HClO 4 (reference filter) Holmium Oxide in perchloric acid A*: 235; 257; 313; 350; 430 W*: 241; 287; 361; 536; 640 S*: 200 (cut-off) R*: Scan 265-270 Set glass filter wavelength accuracy and photometric accuracy: EMC-SET-666 EMC-SET-666-01 EMC-SET-666-02 Holmium Oxide glass filter Neutral density glass filter 0.25 Abs. Neutral density glass filter 0.5 Abs. Neutral density glass filter 1.0 Abs. Empty filter mount, aluminium frame Didymium glass filter Neutral density glass filter 0.5 Abs. Neutral density glass filter 1.0 Abs. Holmium Oxide glass filter Neutral density glass filter 0.5 Abs. Neutral density glass filter 1.0 Abs. A*: 440; 465; 546.1; 590; 635 W*: 279; 361; 453; 536; 638 A*: 270; 280; 297; 320; 340; 440; 465; 546.1; 590; 635 W*: 329; 472; 512; 681; 875 A*: 440; 465; 546.1; 590; 635 W*: 279; 361; 453; 536; 638 *A= Wavelength for absorbance, W= Wavelength for wavelength accuracy, S= Wavelength for stray light, R= Wavelength for spectral resolution E-Mail: info@emc-lab.de www.emc-lab.de 17
Spectrophotometer Reference Materials UV/VIS Reference Materials with EMCLAB Works Calibration Certificate EMC-SET-100 EMC-SET-101 The EMC-glass filters for testing the wavelength accuracy and photometric accuracy enable the user to check quickly and easily its measurement results with the quality standards of the spectrophotometer. All EMC-glass filters are supplied with EMCLAB Works Calibration Certificate. UV/VIS reference materials for testing: Wavelength accuracy Photometric accuracy Art. No. Filters Wavelength (nm) Set glass filter for testing the wavelength accuracy and photometric accuracy: EMC-SET-100 Holmium Oxide glass filter F 10 Neutral density glass filter F 20, 30 % T, Abs. 0.5 Neutral density glass filter F 30, 20 % T, Abs. 0.7 Neutral density glass filter F 40, 10 % T, Abs. 1.0 Blank filter EMC-SET-101 Didymium glass filter F 70 Neutral density glass filter F 20, 30 % T, Abs. 0.5 Neutral density glass filter F 30, 20 % T, Abs. 0.7 Neutral density glass filter F 40, 10 % T, Abs. 1.0 Blank filter A*: 440; 465; 546.1; 590; 635 W*: 279; 361; 453; 536; 638 A*: 270; 280; 297; 320; 340; 440; 465; 546.1; 590; 635 W*: 329; 472; 512; 681; 875 Set glass filter for testing the photometric accuracy: EMC-SET-102 Neutral density glass filter F 20, 30 % T, Abs. 0.5 Neutral density glass filter F 30, 20 % T, Abs. 0.7 Neutral density glass filter F 40, 10 % T, Abs. 1.0 Blank filter 440; 465; 546.1; 590; 635 Single glass filter for testing the wavelength accuracy: EMC-SET-103 Holmium Oxide glass filter F 10 279; 361; 453; 536; 638 Single glass filter for testing the wavelength accuracy and photometric accuracy: EMC-SET-104 Didymium glass filter F 70 A*: 270; 280; 297; 320; 340 W*: 329; 472; 512; 681; 875 *A= Wavelength for absorbance, W= Wavelength for wavelength accuracy 18 E-Mail: info@emc-lab.de www.emc-lab.de
Spectrophotometer Accessories Accessories 1 2 3 4 5 6 Art. No. Accessories Item Cell Holder: EMC-00020 4-cell holder square cuvette 10 x 10 mm, standard 1 EMC-00021 EMC-00022 EMC-00023 4-cell holder square cuvette 10 x 50 mm Cell holder for micro cells Single cell holder EMC-20024 Single cell holder, water-jacketed (not for EMC-11D-V & EMC-11-UV) 2 EMC-00025 Peltier Systems: EMC-00026 4-cell holder, water-jacketed (not for EMC-11D-V & EMC-11-UV) Peltier System, Constant-Temperature-System (not for EMC-11D-V & EMC-11-UV) EMC-00027 Sipper System (not for EMC-11D-V & EMC-11-UV) 3 EMC-00028 Peltier /Sipper System, Constant-Temperature System (not for EMC-11D-V & EMC-11-UV) 3 Lamps: EMC-00011 Halogen lamp 6V10W (only for EMC-11D-V) 4 EMC-00012 Halogen lamp 12V20W 4 EMC-00013 Halogen lamp 12V20W (only for EMC-6 series) 4 EMC-00017 Deuterium lamp for UV 5 Cleaner: EMC-S0020 Cleaning concentrate for cells/cuvettes and optical components, 1 L 6 3 E-Mail: info@emc-lab.de www.emc-lab.de 19
Spectrophotometer Calibration Certificate EMCLAB Spectrophotometers are supplied with Works Calibration Certificate for wavelength accuracy. The Reference Materials for this calibration are DAkkS (German body for accreditation) calibrated and NIST traceable from the DAkkS calibration laboratory D-K-18752-01-00. 20 E-Mail: info@emc-lab.de www.emc-lab.de
Index Product Description Page EMC-11D-V VIS Single beam 4 EMC-11-UV UV/VIS Single beam 5 EMC-16PC-V VIS Single beam 6 EMC-16PC-UV UV/VIS Single beam 6 EMC-18PC-UV UV/VIS Single Beam 6 EMC-31PC-UV UV/VIS Single beam 8 EMC-32PC-UV UV/VIS Single beam/scanning 8 EMC-61PC-UV UV/VIS Double beam 9 EMC-61PCS-UV UV/VIS Double beam/scanning 9 EMC-NANO-UV UV/VIS Single beam 10 EMC-Professional PC Software for EMC-16/18 series 12 EMC-Analyst PC Software for EMC-3, EMC-6 series & EMC-NANO 13 EMC-Cuvettes Glass, Quartz, Plastic 10 mm, 50 mm, Standard/Premium 15 EMC-SETS UV/VIS Reference Materials 17 Spectrophotometer Accessories 19 Calibration Certificate 20 Other types on request Technical changes reserved E-Mail: info@emc-lab.de www.emc-lab.de 21
Dealer: EMCLAB Instruments GmbH Bismarckstrasse 120 47057 Duisburg Germany Fon: +49 203 3064042 Fax: +49 203 3064044 E-mail: info@emc-lab.de Web: www.emc-lab.de