Module 3. Establishing Standard Curve (Bradford Assay)

Similar documents
Protein Quantification Kit (Bradford Assay)

Bradford Reagent, 5x

Materials: Micropipettes (2-20 µl range pipette, µl range, µl range), tips, test tubes with color dye, well plates

Protein assay. Absorbance Fluorescence Emission Colorimetric detection BIO/MDT 325. Absorbance

Biofuel Enzyme LAB. Name

Introduction to Spectroscopy: Analysis of Copper Ore

Protein extraction and quantification by Teresa Fan, University of Kentucky BUFFER PREPARATION AND STORAGE

Experiment 11 Beer s Law

BCA Protein Quantitation Kit

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

Protein assay of SpectroArt 200

GENERAL INSTRUCTIONS

Introduction to Spectroscopy: Analysis of Copper Ore

Experiment 11 Beer s Law

Instructor s Advance Preparation

DETERMINATION OF AN EQUILIBRIUM CONSTANT

Human rheumatoid factor (RF) antibody (IgM) ELISA Kit

Spectrophotometry Materials

Human anti-myelin associated glycoprotein antibody (MAG) Ab ELISA Kit

IgG (Chicken) ELISA Kit

Introduction to Spectroscopy: Analysis of Copper Ore

Human hepatitis B virus surface antigen(hbsag) ELISA Kit

QuickZyme Total Protein Assay (to be used with acid hydrolyzates)

Human anti-deoxyribonuclease B, anti-dnase B ELISA Kit

Safety Rules Reminders

Mouse Anti-OVA-IgE ELISA KIT

The ramylase Project by Ellyn Daugherty

Pig Vascular Endothelial Cell Growth Factor A (VEGF-A) ELISA

Human anti-ige receptor antibody ELISA Kit

BIOO FOOD AND FEED SAFETY. Histamine Enzymatic Assay Kit Manual. Catalog #: Reference #:

Testosterone ELISA, EIA

Chemical Reactions: The Copper Cycle

Incubation time too short Incubate samples overnight at 4 C or follow the manufacturer guidelines.

Introduction to Spectroscopy: Analysis of Copper Ore

Biochemistry I Laboratory CHEM 4401 Units, Concentrations, Solutions & Dilutions

Mouse Glutathione S Transferase Alpha 1 (GSTa1)

Micropipetting Basics

Monkey Kidney injury molecule 1,Kim-1 ELISA Kit

High Sensitivity Polyethylene Glycol (PEG) ELISA Kit

Student Manual. Background STUDENT MANUAL BACKGROUND. Enzymes

Protocol for 2D-E. Protein Extraction

Superoxide Dismutase Activity Assay Kit

NAD + /NADH Assay [Colorimetric]

Human von Willebrand Factor cleavingprotease(vwf-cp) ELISA Kit. Catalog No. MBS (96T)

Human Anti-Ovary Antibody (IgG)ELISA Kit

Olympic B3 Summer Science Camp 2015 Lab 0

Human IL-1 beta ELISA Kit

MEASUREMENT: PART II

Human Coagulation Factor X Total Antigen ELISA Kit

Human placenta lactogen (HPL)ELISA Kit. MyBioSource.com. Catalog No. MBS (96T)

Mouse Insulin ELISA KIT S-Type

Protein Carbonyl Content Assay Kit

ADH Activity Assay Kit

Thermal Energy and Temperature Lab. Experiment Question: How can the difference between thermal energy and temperature be experimentally observed?

Canine Erythropoietin,EPO ELISA Kit

Human 25-hydroxy vitamin D3 (25HVD3) ELISA Kit

Skill Building Activity 2 Determining the Concentration of a Species using a Vernier Spectrometer

Golimumab Free Anti-Drug Antibody ELISA

Human Paraneoplastic pemphigus (PNP)antibody ELISA Kit. Catalog No. MBS (96 T)

Standard Operating Procedure

The ramylase Project by Ellyn Daugherty

Introduction to Spectroscopy: Analysis of Copper Ore

CHGA (Human) ELISA Kit

Rat Advanced Glycation End Products(AGEs) ELISA Kit

Activity 2: Determine the Effect of Temperature on the Reaction Rate

Mouse Cholecystokinin (CCK) ELISA Kit

BCA Protein Macro Assay Kit

Buffers for Biological Systems Laboratory Instructor s Manual

Instructions for use. Glycine ELISA BA E-2100

HBeAg and HBeAg Ab ELISA Kit

INTERNATIONAL CHEMISTRY TESTING. 258 Main Street- Suite 311- Milford, MA Tel: Fax:

Bisphenol A ELISA Kit

Bovine FSH(Follicle Stimulating Hormone) ELISA Kit

RayBio Nickel Magnetic Particles

Modified Adams Assay for Phenolics in Wine

Lab Investigation 4 - How could you make more of this dye?

Sheep myeloperoxidase(mpo) ELISA kit

Rat Coagulation Factor V (F5) ELISA

Human Coagulation Factor XII Total Antigen ELISA Kit

Instructions for use. Chromogranin A ELISA TM E-9000

The Determination of an Equilibrium Constant

PREPARATION FOR CHEMISTRY LAB: FLUORIDE IN WATER

DETERMINATION OF K c FOR AN EQUILIBRIUM SYSTEM

Human Mullerian Inhibiting Substance/Anti-Mullerian hormone (MIS/AMH)Elisa Kit

ASCORBIC ACID METHOD FOR PHOSPHORUS DETERMINATION

Anti-Transglutaminase Antibody ELISA

Cortisol (Horse) ELISA Kit

Porcine Immunoglobulin E (IgE)ELISA Kit

Aflatoxin M1 (AFM1) ELISA Kit

Human anti-gliadin antibody (IgA)ELISA Kit

AP Chemistry Laboratory #15: Reaction Rate of Crystal Violet and Sodium Hydroxide. Lab days: Thursday and Friday, February 1-2, 2018

Polyethylene Glycol (PEG), High Sensitive ELISA

Investigating Food Dyes in Sports Beverages. Sample

Rat Coagulation Factor X (F10) ELISA

Introduction to Chemistry Techniques Prelab (Week 1) 2. Determine the number of significant figures in each of the following numbers.

Figure 1. Structures of compounds to be analyzed by IR.

Mouse low density lipoprotein cholesterol (LDL-C) ELISA Kit

Drexel-SDP GK-12 ACTIVITY

Canine brain natriuretic peptide,bnp ELISA Kit

Caspase Substrate Kit (Colorimetric)

Transcription:

Module 3. Establishing Standard Curve (Bradford Assay) 1. Melissa Myoglobin and the Missing Molecules Melissa Myoglobin had a little tube filled with a clear protein solution. To do more research with this protein, she needed to know some of its properties, including concentration. She knew that to determine the concentration, she needed to know two things: the amount of protein and the volume of the solution (for example, moles/l). She used a micropipette to determine the volume but what about the amount? Could she look at the solution under a microscope and count the molecules? No, even with a microscope, she could not see the protein molecules because they are so small. If she cannot count the molecules, how does she determine the amount in the tube? Think back to Module 2: You measured something that was proportional to NADPH concentration: the absorbance of light. This would work well for Melissa except for the fact that unlike NADPH, the protein does not absorb enough light for a practical measurement at typical concentrations. Melissa had to use a reagent that produces a colored compound when in presence of the protein. The absorbance of the solution is proportional to concentration: the more protein molecules in the tube, the more colored compounds are produced, and the higher the absorbance of the solution. Melissa added the Coomassie reagent to the protein sample and measured the absorbance value to be 0.7. What is the concentration? An absorbance value alone tells Melissa very little about the concentration. She needs a standard for comparison. What is a standard? Melissa thought about the time when an alien from a foreign planet visited the classroom. The alien was sad because he did not know how tall he was and all the kids in the class new their heights. The alien was taller than the shortest kid and shorter than the tallest student. The class decided all they needed was a measuring stick but their teacher, Dr. Scatterbrainius, could not find one. So the students decided to create a number of standards that spanned the full range of possible heights. They lined up from the shortest to the tallest and had the alien find the two kids he was the closest in height to. The alien then asked these two for their heights, and voila, the alien knew his own height by comparison. The picture on a roll of ph paper is another example of a standard for comparison; here you observe the color of the paper to determine ph of a solution (see figure). The color of the paper is a proxy for the ph of the solution. Children are often mesmerized by how scientists magically collect data and information. How do they know where and what to look for and where does all that information come from? One step in growing into a scientist happens when you realize how much of data is acquired by comparing. Machines and techniques rely on comparisons, for example, between an unknown and known concentration of a compound. In order to give a number to knowledge, there must often be a scale or a set of standards. In this lab, you can learn to set up a scale for measuring protein concentrations. 2. Purpose of the lab The instructor will provide you with solution of the protein Bovine Serum Albumin (BSA) with a concentration of 2 mg/ml (attention: the concentration units are mass per volume). Your assignment is to design and implement a protocol to establish a standard curve for BSA that shows the relationship between absorbance and protein concentration. You will make solutions with different known BSA concentrations, add each to a colorimetric reagent, and measure the resulting absorbance values. You will make a graph that shows absorbance on the y-axis and protein concentration on the x-axis. This is called a standard curve, a kind of a ruler that tells you what absorbance values to expect for specific protein concentrations. In other words, you will determine the relationship between absorbance and protein concentration. 1

3. Agenda for the Day You must have worked through Math Moment problems before coming to class. Upon entry, each student shows their work to instructor to receive points. Presentation on preparing a standard curve, its limits, and associated challenges. In class, groups review Math Moment Problems to prepare for experimental design. Experimental design: Groups discuss and agree on experimental protocol. Each student writes down a step-bystep protocol for the experiment. Conduct the experiment in groups. Each student individually records data in their personal laboratory notebook. Clean up 4. Background Useful information can be found Chapter 3A under section Buffer dilutions and 3B under section The Bradford Assay in the textbook (Boyer). BioRad Protein Assay Protocol has a sample protocol model your protocol on the standard protocol for microtiter plates that starts on page 6: http://www.bio-rad.com/webroot/web/pdf/lsr/literature/lit33.pdf In the Bradford Assay, a reagent molecule (Coomasie Brilliant Blue) binds to a protein and changes the color of the solution. A spectrophotometer can be used to read the absorbance at the appropriate the wavelength. The absorbance values increase with increasing protein concentrations. 5. Math Moments 1. Dilution calculation, you can use C 1 V 1 = C 2 V 2. How many milliliters of water should be added to 15.0 ml of 0.50 M Tris buffer to make 0.15 M Tris buffer? Hint: The final volume (V 2 ) is the sum of the volume of the water and the volume of the Tris buffer (V 1 ). 2. Fill in the blanks in the linear dilution table shown below. Assume that the stock solution is 2.0 M and you require 20 ml diluted samples of the following final concentrations: 1.66 M, 1.33 M, 1.0 M, 0.66 M, 0.33 M, and 0.00 M. Note the similarities between this table and the dilution table you will need to create for your experimental design. Stock (M) Final concen. (M) Stock (ml) Water (ml) Final volume (ml) 2.0 1.66 20 2.0 1.33 20 2.0 1.0 20 2.0 0.66 20 2.0 0.33 20 2.0 0.00 20 Table for a linear dilution process. Fill in blanks. A dilution is the process of combining specific volumes of a solution of analyte with solvent to make less concentrated solutions of analyte. This is one of the important skills that you need to master during your undergraduate training because it is done again and again as part of biochemical research. 3. Given the protein standard curve in the figure, is the X-axis shown in units of mass or concentration? What mass of protein is present in a sample that has an Absorbance of 0.3 based on the standard curve shown? Absorbance 0.6 0.5 0.4 0.3 0.2 0.1 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 2 microgram protein

4. If 10 µl of protein sample was added to the assay in the question above, what was the concentration of the protein sample in units of µg/µl? Hint: From the standard curve above, you know the mass in µg. You know the volume of the sample used on the assay in ul. By dividing mass by volume (µg/µl), you will be able to determine the concentration. 5. What is the concentration in the question above in units of mg/ml? Hint: This is a unit conversion from µg/µl to mg/ml. 6. In the standard curve above, please convert the values on the x- Mass of protein Concentration Concentration of of protein axis from mass (µg) to concentration (µg/µl) of protein sample. in assay (ug) in protein assay sample (ug/ul)(µg/µl) Note: Concentration of protein sample refers to the sample that was 20 made before adding anything to the wells. The volume of protein 40 used in the assay is 10 µl for each data point. What are the 60 concentrations on the x-axis that correspond to 20 µg, 40 µg, 60 µg, 80 80 µg, and 120 µg (Fill in table)? For this question, you will simply 120 need to divide the amount of protein (mass in µg) by volume in µl. Notice that you can express the standard curve as absorbance vs. protein concentration or absorbance vs. protein amount. 7.a. A student added 200 µl of Coomassie Reagent and 10 µl of protein sample (0.1 mg/ml) into a well in a microtiter plate. As stated above, the concentration of the protein sample in question is 0.1 mg/ml. What is the concentration (mg/ml) of the protein in the well (once mixed with the Coomassie Reagent)? 7.b. What is the amount of protein in well in units of µg? 8. Solve the following equations for x. y = mx + b y = 6. Supplies Provided Ice buckets and ice BSA protein standard at a concentration of 2.0 mg/ml - KEEP IT IN ICE! Buffer Bradford Reagent (already diluted to 1X) Eppendorf tubes Micropipettors and tips (multi-channel pipettors) 96-well microtiter plates Plate shaker UV - VIS microtiter plate spectrophotometer 7. Experimental Design 3

You will design an experiment to determine the relationship between absorbance of Coomassie dye and protein (BSA) concentration. This relationship represents a standard curve. The instructor will give you 100 µl of solution of BSA (protein) that has the concentration 2.0 mg/ml. For your dilutions calculations, this concentration represents the stock concentration (C 1 ). The linear range of the standard microtiter plate assay is 0.05 mg/ml to approximately 0.5 mg/ml (See Biorad Protocol). This means you must prepare solutions that have BSA concentrations in this range in Eppendorf tubes. Note that the Eppendorf tubes hold up to about 1.8 ml of liquid. This means the concentration of the first solution should be 0 mg/ml (this is the negative control) and the concentration of the last solution (least diluted or most concentrated standard) around 0.5 mg/ml. You will add 10 μl of each solution into a well containing 200 µl of Coomassie Reagent as described in the Biorad protocol. Note: the volume of reagent will be large compared to the volume of BSA solution. For this lab, you will need to figure out how to prepare dilutions to make the necessary protein standards. The solvent will be buffer. You can use the equation C 1 V 1 =C 2 V 2 to determine how to make the necessary dilutions. You will need to make some decisions including 1. Total (final) volume (V 2 ) of each dilution; 2. Number of BSA dilutions will you make (how many data points will you have?) (this should be no fewer than five) and; 3. Concentrations of BSA (C 2 ) standards. You must prepare each experiment (well) in triplicate (or you can choose more replication). This means you will repeat the same well a minimum of 3 times. Since you need 10 µl of BSA standard for each well, you need a minimum of 30 µl of each BSA standard. In reality you need more than 30 µl because some solution will be stuck to the tube and the pipette tip etc. It is easier to work with slightly larger volumes because pipetting errors are typically lower for larger volumes. Shown is a template for a 96-well plate that you will use to measure absorbance values. You can fill it in any order but you must know what you have in each well. The wells on such a plate are labeled by a combination of letters and numbers. In the plate shown, the well in the top left corner is well A1 etc. Think about how you will organize your samples in the plate and include this information in your protocol. You do not need to fill all the wells; empty wells will show the absorption value of the plastic and air. The recommended wavelength for Bradford Assay is 595 nm. The plate reader in the lab does not read that specific area but very close, 564 nm. Please, in your lab notebook and procedure, write down this wavelength. 8. Common Mistakes and Some Advice There will be much pipetting. Remember good pipetting technique. Work in an orderly manner, record all your work, and be as accurate as possible. Before using a pipettor, double-check that the volume you are wishing to aspirate is correct (and not tenfold bigger or smaller). Please, handle pipettors gently. When adding the reagent to the wells, do not empty the pipettor to the second stop (that makes lots of bubbles) and do have the tip touch the sidewall of the well. Keep your BSA solutions on ice to prevent denaturation. After the 96-well is ready, place it briefly on the plate shaker. The plate snaps onto the holder in the shaker. Do this gently. The plate should be incubated at least 5 minutes before placing it in the reader. You will measure the absorbance of the samples in the plate using a plate reader. Note: after gently snapping the plate onto the plate holder, do not push the tray in. You will control the plate reader from the computer. The plate will go in automatically and you will break the plate-reader if you manually push the plate in. The mechanism is very delicate. Once you have the absorbance values, take a picture of the computer screen and then type the values in a data sheet in excel. 4

Plot the standard curve on a grid paper or graph with Excel in class to make sure that it is linear and that you do not need to repeat the experiment. Student often are confused by the x-axis in a standard curve. The standard curve sometimes shows absorbance versus amount of substance and other times absorbance versus of concentration of sample. It may be less confusing to work with amounts while doing an assay, especially because dilutions are required. As long as you know the original volume of sample that was used in an assay, determination of amount in the well is easy. Amount of BSA in well = Concentration of BSA solution used for this well (mg/ml)*volume of the BSA solution used in the assay (ml). Another occasional point of confusion is the distinction between BSA concentrations of the standard solutions (the dilutions you make in eppendorf tubes) and the BSA concentrations in the wells of the microtiter plate. You will make a set of solutions (your standards) in Eppendorf tubes. You will then take 10 ul of each solution and mix with 200 ul of Coomassie reagent in a well in a microtiter plate. After you mix 10 ul of BSA solution with the Coomassie reagent, the BSA concentration in the well is lower (by 21-fold) compared to the BSA standard in the eppendorf tube. When preparing your standard curve, if you express your x-axis as a concentration, be clear about whether it is the BSA concentration in the well in the microtiter plate (after combining protein with Coomassie Reagent) or the BSA concentration of the standard solution you prepared in your Eppendorf tube. 9. Vocabulary BSA, standard, incubate, aliquot, reagent (dye), colorimetric spectroscopy, 96-well plate, microtiter plate, Bradford reagent, Coomassie reagent 10. Safety You must wear safety glasses when conducting the experiment. You must never eat or drink in the laboratory. You will need to wait in line to use the plate reader. Please, be patient when waiting for your turn to use the plate shaker and plate reader. Be gentle with the plate reader and plate shaker, these are delicate instruments. Any observed violations of these rules will result in lower final grade and/or removal from the lab. These safety items are solely the responsibility of the student. 11. Clean up For clean-up, return the remaining original solution to the instructor. Discard dilutions in the sink and eppendorf tubes in the regular trash. Do not throw anything in the biohazard waster. Wash 96-well plates and leave them at the sink to dry. Return pipettors in the correct boxes, the last person puts the boxes in the cabinet in the back of the lab. Dry your ice buckets and place them back in the cabinet. Place all other items where you got them from. Make sure they are clean. Leave your bench ready for the next class to start working. 12. Data Sheet (Homework) and Protocol Hand in the protocol you wrote today at the end of the session (one per student). Hand in a 1-page data sheet (one per group) with data and calculations one week after the completion of the Module. Include the names of your group members, date, class, section and instructor name. Provide the data sheet in professional format, include correct units, data labels etc. Do not use excessive significant figures and present your data in tables when possible. Remember to include the following: Table showing your data. Remember units, label each column and row clearly and precisely. Standard Curve. You will need to prepare a standard curve by plotting average blank-corrected 564 nm measurements for each BSA standard vs. its concentration in µg/ml (or you can use amounts). Remember to provide captions for your tables and figures. 5