Transient wall shear stress measurements at a high Reynolds number

Similar documents
Implementing unsteady friction in Pressure Time measurements

THE PRESSURE-TIME MEASUREMENTS PROJECT AT LTU AND NTNU

UNCERTAINTIES FOR PRESSURE-TIME EFFICIENCY MEASUREMENTS

Review for Exam Hyunse Yoon, Ph.D. Assistant Research Scientist IIHR-Hydroscience & Engineering University of Iowa

Review for Exam Hyunse Yoon, Ph.D. Adjunct Assistant Professor Department of Mechanical Engineering, University of Iowa

Review for Exam Hyunse Yoon, Ph.D. Adjunct Assistant Professor Department of Mechanical Engineering, University of Iowa

International Journal of Civil Engineering and Geo-Environment. Investigation of Parameters Affecting Discrete Vapour Cavity Model

FLUID MECHANICS PROF. DR. METİN GÜNER COMPILER

On the Similarity of Pulsating and Accelerating Turbulent Pipe Flows

Comparison of numerical and experimental results of the flow in the U9 Kaplan turbine model

Investigation of Flow Profile in Open Channels using CFD

Basic Fluid Mechanics

Chapter 3 NATURAL CONVECTION

Self-Excited Vibration in Hydraulic Ball Check Valve

Visualization of flow pattern over or around immersed objects in open channel flow.

Chapter 8: Flow in Pipes

Turbulence Laboratory

SECTION 5: CAPACITANCE & INDUCTANCE. ENGR 201 Electrical Fundamentals I

Applied Fluid Mechanics

Applied Fluid Mechanics

Principles of Convection

Head loss coefficient through sharp-edged orifices

Rotordynamic Forces from Dischargeto-Suction Leakage Flows in Centrifugal Pumps : Effects of Geometry*

Modelling of Foam Spread on a Burning Liquid Fuel Surface

Chapter 8: Flow in Pipes

IMPROVED METHOD FOR SIMULATING FRICTIONAL LOSSES IN LAMINAR TRANSIENT LIQUID PIPE FLOW KAMIL URBANOWICZ, ZBIGNIEW ZARZYCKI

The Effect of Endplates on Rectangular Jets of Different Aspect Ratios

Experimental investigation on a high head model Francis turbine during load rejection

IMPROVING THE HEAT TRANSFER CHARACTERISTICS OF THE SPIKY CENTRAL RECEIVER AIR PRE-HEATER (SCRAP) USING HELICALLY SWIRLED FINS

Theoretical and Experimental Studies on Transient Heat Transfer for Forced Convection Flow of Helium Gas over a Horizontal Cylinder

On the transient modelling of impinging jets heat transfer. A practical approach

Liquid or gas flow through pipes or ducts is commonly used in heating and

Hydraulics Prof. Dr. Arup Kumar Sarma Department of Civil Engineering Indian Institute of Technology, Guwahati

Fluid Mechanics Prof. T.I. Eldho Department of Civil Engineering Indian Institute of Technology, Bombay. Lecture - 17 Laminar and Turbulent flows

Comparison of MOC and Lax FDE for simulating transients in Pipe Flows

Experiments on the perturbation of a channel flow by a triangular ripple

Forced Convection: Inside Pipe HANNA ILYANI ZULHAIMI

Turbulence is a ubiquitous phenomenon in environmental fluid mechanics that dramatically affects flow structure and mixing.

STRUCTURAL RESPONSE OF A PIPELINE APPARATUS TO PULSATING FLOW AT RESONANCE AND NON- RESONANCE CONDITIONS

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH

Chemical Engineering 693R

Lesson 6 Review of fundamentals: Fluid flow

Log laws or power laws: The scaling in the overlap region

Parameters affecting water hammer in metal pipelines

Unsteady skin friction experimentation in a large diameter pipe

7. Basics of Turbulent Flow Figure 1.

Fluid Mechanics. du dy

Experiment (4): Flow measurement

Viscous Flow in Ducts

CHAPTER 3 BASIC EQUATIONS IN FLUID MECHANICS NOOR ALIZA AHMAD

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

Physics 3 Summer 1990 Lab 7 - Hydrodynamics

Longitudinal Dispersion Coefficients within Turbulent and Transitional Pipe Flow

An-Najah National University Civil Engineering Department. Fluid Mechanics. Chapter 1. General Introduction

Heat Transfer Investigation in Engine Exhaust-Type Pulsating Flow

Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition

The influence of disc friction losses and labyrinth losses on efficiency of high head Francis turbine

ME3560 Tentative Schedule Spring 2019

FE Fluids Review March 23, 2012 Steve Burian (Civil & Environmental Engineering)

Installation effects on an ultrasonic flow meter with implications for self diagnostics

vector H. If O is the point about which moments are desired, the angular moment about O is given:

Convection. forced convection when the flow is caused by external means, such as by a fan, a pump, or atmospheric winds.

ME3560 Tentative Schedule Fall 2018

BERNOULLI EQUATION. The motion of a fluid is usually extremely complex.

CONVECTIVE HEAT TRANSFER

Tutorial for the heated pipe with constant fluid properties in STAR-CCM+

EXPERIMENT No.1 FLOW MEASUREMENT BY ORIFICEMETER

Flow analysis in centrifugal compressor vaneless diffusers

6. Basic basic equations I ( )

Keywords: Spiral plate heat exchanger, Heat transfer, Nusselt number

UNIT II Real fluids. FMM / KRG / MECH / NPRCET Page 78. Laminar and turbulent flow

INTEGRATION OF CURRENT METER MEASUREMENTS IN GENERAL FLOW CROSS SECTIONS

FLUID MECHANICS PROF. DR. METİN GÜNER COMPILER

Uniform Channel Flow Basic Concepts. Definition of Uniform Flow

WALL PRESSURE FLUCTUATIONS IN A TURBULENT BOUNDARY LAYER AFTER BLOWING OR SUCTION

LIQUID FILM THICKNESS OF OSCILLATING FLOW IN A MICRO TUBE

CFD Analysis for Thermal Behavior of Turbulent Channel Flow of Different Geometry of Bottom Plate

1. Fluid properties and concept of continuum

Fluid Mechanics Prof. S.K. Som Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Basic Fluid Mechanics

Lecture 2 Flow classifications and continuity

Experimental Investigation of a High Head Model Francis Turbine During Steady-State Operation at Off-Design Conditions

The most common methods to identify velocity of flow are pathlines, streaklines and streamlines.

EXPERIMENT II - FRICTION LOSS ALONG PIPE AND LOSSES AT PIPE FITTINGS

ANALYSIS OF HEAT TRANSFER IN TURBULENT FLOW THROUGH THE TUBE WITH UNIFORM HEAT FLUX

Some Aspects of Oscillatory Visco-elastic Flow Through Porous Medium in a Rotating Porous Channel

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Chapter 6 The Impulse-Momentum Principle

Analysis of the Cooling Design in Electrical Transformer

where = rate of change of total energy of the system, = rate of heat added to the system, = rate of work done by the system

centrifugal acceleration, whose magnitude is r cos, is zero at the poles and maximum at the equator. This distribution of the centrifugal acceleration

Figure 3: Problem 7. (a) 0.9 m (b) 1.8 m (c) 2.7 m (d) 3.6 m

ISO 9906 INTERNATIONAL STANDARD. Rotodynamic pumps Hydraulic performance acceptance tests Grades 1 and 2

An overview of the Hydraulics of Water Distribution Networks

Convection. U y. U u(y) T s. T y

Unsteady Volumetric Entropy Generation Rate in Laminar Boundary Layers

Higher-order Turbulence Products of Velocity and Temperature for Adverse Pressure Gradient Boundary Layer Flows

Study on Flow Characteristics of Oil Viscosity Pump for Refrigerant Compressors

COURSE NUMBER: ME 321 Fluid Mechanics I 3 credit hour. Basic Equations in fluid Dynamics

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 05 Issue: 03 Mar p-issn:

Transcription:

Transient wall shear stress measurements at a high Reynolds number L.R. Joel Sundström 1 *, Helene Dahl 2, Magni Fjørtoft Svarstad 2, Torbjørn K. Nielsen 2, Ole G. Dahlhaug 2 and Michel J. Cervantes 1,2 1. Division of Fluid and Experimental Mechanics, Luleå University of Technology, Luleå, Sweden 2. Water Power Laboratory, Department of Energy and Process Engineering, Norwegian University of Science and Technology, Trondheim, Norway * Corresponding author: joel.sundstrom@ltu.se Abstract Wall shear stress measurements utilizing hot-film anemometry in a high Reynolds number laboratory pipe flow (RRRR = 1.7 10 6 ) retarding to a complete rest have been presented. The purpose of the measurements was to investigate the level of unsteadiness in the wall shear stress during a Gibson (hydropower flow rate) measurement. The ensemble-averaged wall shear stress from 44 repetitions has been compared with the results obtained from both the standard, the unsteady transient Gibson method, and a quasi-steady Gibson approach. The results show very small differences between the measured wall shear stress and the estimated values. The small deviations between the standard Gibson method and the measured values are encouraging. For, if transient modeling of the wall shear stress can be avoided, this would be beneficial because any empirical parameter entering a transient formulation must, inevitably, be experimentally calibrated at Reynolds numbers much smaller than those encountered in a typical Gibson measurement, thus introducing uncertainties regarding the extrapolation of such models to high Reynolds numbers. Albeit being a large Reynolds number in the lab scale, RRRR = 1.7 10 6 is still one or two orders of magnitude smaller than that typically encountered in hydropower. Thus, direct transfer of the present result to a full scale measurement cannot be done without further studies. More detailed processing of the present data, as well as studies of five other sets of measurements are underway and will be presented elsewhere. 1. Introduction The pressure-time method, also known as Gibson s method in memorial of the pioneering work by N.R. Gibson [1], is a cost-efficient and commonly utilized method to measure the flow rate in closed conduits. The principle of the method is derived by realizing that the pressure force acting on a decelerating enclosed volume of water is proportional to the rate of change of momentum and the frictional losses. By integrating this force balance, it is straightforward to show that the discharge, Q 0, before the commencement of the transient is given by tt QQ 0 = AA ρρρρ ( Δpp + ξξ)dddd + qq, (1) 0 where AA, ρρ, LL, Δpp, ξξ, qq and tt are the cross-sectional area, the fluid density, the measuring length, the differential pressure, the frictional losses, the discharge after the transient, and the upper integration limit, respectively. The differential pressure is, in many instants, straightforward to measure with high accuracy when performing a pressure-time measurement in a full-scale hydropower plant. The frictional losses do, however, require modeling. In the standard Gibson method described in IEC41 [2], ξξ is calculated by ξξ = CCQQ(tt) 2. (2) C is a constant loss-coefficient, extracted from the pre-transient pressure loss, and Q(t) is the instantaneous value of the time-varying flow rate. Jonsson et al. [3] found a systematic error of the calculated flow rate that was dependent on the initial Reynolds number. When the initial Reynolds number was increased from 0.6 10 6 to 1.7 10 6, the error decreased from positive to 1

negative. Jonsson et al. [4] suggested that the discrepancy originated from an inaccurate formulation of the frictional losses (eq. 2), and to overcome this deficiency, the authors introduced an unsteady Gibson method. In the unsteady formulation, the instantaneous value of ξξ is estimated by calculating the value that would prevail if the flow was in equilibrium, obtained from the steady state friction factor, plus a contribution due to the unsteadiness of the flow, modeled by the time dependent part of the Brunone friction factor ff bb = kkkk UU UU (3) The convective part of the formulation has been neglected. D is the pipe diameter, and U is the instantaneous bulk flow velocity. The coefficient k is determined through an empirical relation (see Jonsson et al. [4], for details on the determination of k and the justification of neglecting convective effects). With the inclusion of unsteady friction, the systematic error was shown to decrease and the calculated flow rate error compared to the standard Gibson approach decreased. In the present paper, selected findings from wall shear stress measurements performed in a laboratory during a Gibson flow rate measurement are presented. The ensemble-averaged wall shear stress, obtained from many repeated runs, was measured using hot-film anemometry. The measured wall shear stress is compared with estimates from the standard, as well as, the unsteady Gibson method. The objective of the work is to assess how the current means of modeling frictional losses in the Gibson method compare with direct wall shear stress measurements. Measurements of differential pressure have been performed as well; however, these results will show up only in the wall shear stress estimations. The effects of varying L and Q 0 have been described elsewhere (Jonsson et al. [3]), and will thus not be reconsidered in here. 2. Experimental apparatus The experiments were performed in a 27 m long straight pipe of internal diameter D=300 mm. Water was supplied to the system from a 9.75 m high, constant-head tank, as shown schematically in figure 1. The flow rate retardation was realized by closing a computer-controlled, hydraulically driven knife gate. The gate closing-time was set to approximately 4 s, and only realizations that were repeatable within ± 0.15 s were kept for ensemble-averaging of the wall shear stress. The Reynolds number, based on the bulk velocity, pipe diameter and fluid viscosity, RRRR = UUUU νν, before the commencement of the retardation was approximately 1.7 10 6. Pressure measurements were performed 37D and 50D away from the inlet, respectively, whereas the wall shear stress was measured at 52D. The hydrodynamic entry length L H can be estimated from the empirical relation LL HH /DD = 1.359RRee 1/4 (Kasar et al. [5]), which takes a value of 49. The pressure and the wall shear stress are known to be flow quantities that develop quicker than, e.g., the turbulent fluctuations of the velocity (see He et al. [6]), and thus, the entry length in the present study is judged to be sufficient for inlet effects to be small. 2.1 Measurement methods Figure 1. Schematic illustration of the experimental set up. 2

For reference, the bulk flow rate was measured using a Krohne optiflux electromagnetic flow meter. Two UNIK 5000 absolute pressure sensors (0-5 bar) separated by a distance of L=4 m were used to measure the differential pressure. Wall shear stress measurements were performed by using three hot-film sensors. The hot-film sensors were mounted evenly around the circumference at one axial location. Calibration of the hot-film sensors were performed in-situ before and after the measurement by varying the Reynolds number between 1.7 10 6 and 0 in 12 steps. The flow rate at each Reynolds number was kept constant for 70 s, but only the data acquired during the last 50 s were used for the hot-film-voltage to wall shear stress calibration curve. At each Reynolds number, an estimate of the wall shear stress was obtained from the friction factor, f, the bulk flow velocity and the fluid density through τ = 1 8 ρfu2. The friction factor was extracted from the empirical relation 1 = 1.901 log f 10(Re f) + 0.432, suggested by Zagarola & Smits [7]. The expression for the friction factor has been derived from measurements over the range 31 10 3 < Re < 35 10 6, and is believed to be the most accurate representation of the friction factor. In the present setup, for RRRR > 6 10 5, the friction factor calculated from the pressure drop was within 2% of the empirical formula. For RRRR < 6 10 5, however, the differential pressure was small and thus difficult to measure with sufficient accuracy. The approach of calibrating the hot-film versus the pressure drop was, therefore, abandoned altogether (although this is more direct) to have a single calibration procedure over the entire range of Reynolds numbers. For RRRR > 2 10 5 the hot-film voltages, E, aptly fitted the estimated wall shear stresses by a logarithmic expression, log 10 (ττ) = AAAA + BB, where A and B are calibration constants. For RRRR < 2 10 5, the standard relation ττ 1/3 = AA EE 2 + BB was used. In addition to flow rate, pressure and wall shear stress, the gate position and the water temperature were recorded. The signals were acquired simultaneously at a sampling rate of 2 khz. The ensemble-averaged wall shear stress presented in the results section is from 44 repeated runs. 3. Results and discussion 3.1 Preliminaries For RRRR < 4.5 10 4, the tendency of the wall shear stress in a linearly decelerating flow to deviate from the quasi-steady value, i.e., the value that would prevail for a steady-state flow at the instantaneous Reynolds number, has been shown to depend on the relative importance of turbulence dynamics and inertia (see Ariyaratne et al. [8]). A quantitative measure of this tendency is derived from the ratio of the turbulence time scale, νν/uu 2 ττ0, to the time scale of the inertia, UU 0 dddd dddd 1, i.e., through a non-dimensional parameter δδ = νν 2 uu ττ0 1 dddd UU 0 dddd. (4) Where uu ττ0 and UU 0 are the friction and the bulk velocities before the commencement of the deceleration, and dddd dddd is the (constant) bulk flow deceleration. For δδ < 10 3, the transient wall shear stress shows negligible deviations from quasi-steady values (RRRR < 4.5 10 4 ). In the present work, the rate of deceleration is not constant, however, a mean δδ can be defined based on the closing time and the initial bulk velocity (which is known from the flow meter). This mean δδ takes a value of 5.7 10 6, and, if the results for low-reynolds-number flows can be directly transferred to high-reynolds-number flows, deviations from the quasi-steady values should be negligible. 3.2 Results The time-developments of the ensemble-averaged mean wall shear stresses measured by the three hot-film sensors are plotted in figure 1a. Data is plotted from the instant that the gate starts to close, but, owing to the fact that the knife gate does not alter the flow rate until it has reached approximately 70% of its initial position, the wall shear stress remain unaltered until t > 1 s. The flow shows no tendency to develop asymmetrically in space, but large fluctuations are observed in the measured signals. The large fluctuations are a result of the high turbulence intensity close to the wall; it has been shown in numerous studies (see Alfredsson et al. [9], e.g.) that ττ rrrrrr 0.4, in ττ steady state. Owing to the circumferential symmetry of the wall shear stress, the mean value of the 3

signals measured from the three sensors is employed for the results presented henceforth (which dampens the fluctuations as shown in figure 1b). To judge whether the transient wall shear stress deviates from the estimated values, the instantaneous bulk velocity is required. The flow meter utilized in the present study is not suitable to extract this information, as the response time is too slow. The bulk velocity has therefore been approximated by the cumulative velocity distribution obtained from the integral in eq. 1. Figure 2c-e displays the wall shear stresses estimated from a typical realization of a Gibson measurement together with the measured values. Initially, when the rate of deceleration is low, the measured and estimated values overlap. With time, the deceleration rate increases, and so does the flow unsteadiness. As a result, small discrepancies between the measured and estimated values are observed, especially for the quasi-steady values, see figure 2 e. However, it should be noted that the exact trend between the measured value and the various estimates differ somewhat between each realization, owing to the spread in closing time among the repetitions (±0.15s). The fact that the measured and estimated values do not differ appreciably is encouraging for the Gibson method. For, the results show that accurate estimates of the wall shear stress can be obtained without advanced modeling of the losses. Furthermore, the turbulence time scales in full scale hydropower are even smaller than those in the present study owing to the high Reynolds numbers. Thus, the effect of the imposed deceleration is expected to be even smaller in an in-site measurement, especially since the deceleration time is usually fairly long (>30s). The short time scale of the turbulence in comparison to the imposed deceleration is in favor of a quasi-steady approach for evaluating the losses (although this approach displays the worst agreement in figure 2). The quasi-steady formulation takes into account the increase in friction factor, as opposed to the standard approach, yet being simple because it incorporates available formulae for the friction factor (see, e.g., the expression of Zagarola and Smits [7]). The good agreement between the measured and the estimated wall shear stresses are from a single case. If this result is a general trend must be investigated in detail by analyzing more data sets. Further measurements, incorporating different closing times, and closing curves, as well as a lower initial Reynolds number have been performed in conjunction to the present measurement. The processing of this data is under way, and is therefore not reported in here. As a final remark, it should be noted that the hot-film measurements are not without errors. Uncertainty estimates presented by Sundstrom et al. [13] and He et al. [6], indicates that the uncertainty of unsteady wall shear stress measurements by hot-film anemometry are of the order of ±10%. 4. Conclusions Wall shear stress measurements using hot-film anemometry have been presented for a transient turbulent pipe flow. An initially steady flow at a Reynolds number of 1.7 10 6 was brought to a complete rest by closing a knife gate over a time-period of 4 s. The ensemble-averaged mean wall shear stress calculated from 44 repeated runs has been compared with estimates obtained from a Gibson flow rate measurement. It has been shown that both the measured wall shear stress and the wall shear stress calculated with either the standard Gibson approach, the recently proposed unsteady Gibson method, and a quasi-steady Gibson method all produce wall shear stress traces that are very similar. Such result is promising because it shows that the standard Gibson method, despite its simplicity, accurately predicts the losses in the evaluation procedure. Avoiding transient modeling of the wall shear stress in the Gibson flow rate evaluation is practical, because the empirical parameters entering such formulations can rarely be tuned at the high Reynolds numbers encountered in typical hydropower measurements. However, the direct applicability of the present results to a full scale measurement should be imposed with caution because the Reynolds number, albeit large in the lab scale, is still one or two orders of magnitude smaller than that encountered in a hydropower plant. Thus, the generality of the results cannot be guaranteed. Further measurements with different closing times, and closing sequences, as well as a different initial Reynolds number have been undertaken in conjunction to the currently presented measurements. The results from these measurements are, however, still under processing and will be presented elsewhere. 4

(a) (b) (c) (d) (e) Figure 2. Time-development of the wall shear stress during gate closure. a) and b), measurements performed at three circumferential positions and the average of these measurements, respectively; c) standard Gibson; d), unsteady Gibson; e) quasi steady. 5

Acknowledgement The research presented was carried out as a part of "Swedish Hydropower Centre - SVC". SVC has been established by the Swedish Energy Agency, Elforsk and Svenska Kraftnät together with Luleå University of Technology, The Royal Institute of Technology, Chalmers University of Technology and Uppsala University. www.svc.nu. References [1] N. R. Gibson. The Gibson method and apparatus for measuring the flow of water in closed conduits. ASME Power Division, 45:343 392, 1923. [2] IEC 41. International standard - field acceptance tests to determine the hydraulic performance of hydraulic turbines, storage pumps and pump-turbines, volume 41. International Electrotechnical Commision, Geneva, Switzerland, 3 rd edition, 1991. [3] P. P. Jonsson, J. Ramdal, and M. J.Cervantes. Experimental investigation of the Gibson method outside standards. In Proceedings of the 24th IAHR Symposium on Hydraulic Machinery and System. Foz do Iguacu, Brazil, 2008. [4] P.P. Jonsson, J. Ramdal, and M.J. Cervantes. Development of the Gibson method Unsteady friction. Flow measurements and instrumentation, Vol 23(1), PP19-25, 2012 [5] S. Kasar, R.K. Shah, and W. Aung. Handbook of Single-Phase Convective Heat Transfer. John Wiley & Sons, 1987. [6] S. He, C. Ariyaratne, and A.E. Vardy. Wall shear stress in accelerating turbulent pipe flow. J. Fluid Mech. 685, 440 460, 2011. [7] M. Zagarola and A.J. Smits. Mean-flow scaling of turbulent pipe flow. J. Fluid Mech. 373, 33 79,1998. [8] C. Ariyarante, S. He, and A.E. Vardy. Wall friction and turbulence dynamics in decelerating pipe flows. J. Hydraul. Res., 48(6), 810 821, 2010. [9] P. H. Alfredsson, A.V. Johansson, J.H. Haritonidis and H. Eckelmann. The fluctuating wall shear stress and the velocity field in the viscous sublayer, Physics of Fluids, (1958-1988) 31, 1026, 1988. [10] S. He and M. Seddighi. Turbulence in transient channel flow. J. Fluid Mech. 715, 60 102, 2013. [11] M. Seddighi, S. He, A.E. Vardy and P. Orlandi. Direct numerical simulation of an accelerating channel flow. Flow Turbulence Combust. 92:473 502, 2014. [12] A. Bergant, A.R. Simpson and J. Vitkovsky. Developments in unsteady pipe flow friction modelling. J. Hydraul. Res., 39(3), 249 257, 2001. [13] L.R. J. Sundstrom, B.G. Mulu and M.J. Cervantes. Wall friction and velocity measurements in a double-frequency pulsating turbulent flow. J. Fluid Mech. 788, 521-548, 2016. 6