Pushing the Limits: Dark Matter Search with SuperCDMS. Wolfgang Rau Queen s University Kingston For the SuperCDMS Collaboration

Similar documents
Scalability of the SuperCDMS experiment

Recent Results from the Cryogenic Dark Matter Search. Bruno Serfass - UC Berkeley on behalf of the CDMS and SuperCDMS collaborations

Constraints on Low-Mass WIMP Signals from CDMS. Steven W. Leman (MIT) 18 March 2011 Rencontres de Moriond EW La Thuile, Valle d Aosta, Italy

CDMS-II to SuperCDMS

Results from CRESST and CDMS

CDMS. Vuk Mandic. 13. July 2010

Identification of the Surface Event Background in the CDMS II Experiment. Sunil Golwala for the CDMS II Collaboration Caltech August 21, 2008

Present Status of the SuperCDMS program

Status of the Cryogenic Dark Matter Search Experiment

WIMP EXCLUSION RESULTS FROM THE CDMS EXPERIMENT

Supporting Online Material for

New Results from the CDMS-II experiment

SuperCDMS SNOLAB: A G2 Dark Matter Search. Ben Loer, Fermilab Center for Particle Astrophysics On behalf of the SuperCDMS Collaboration

Analysis of the low-energy electron-recoil spectrum of the CDMS experiment

The complex vacuum configurations contribute to an extra non-perturbative term in the QCD Lagrangian[1],

arxiv: v3 [physics.ins-det] 4 Oct 2013

Direct Searches for Dark Matter and the CDMS Experiment

First CDMS II Five-Tower Results. Sunil Golwala SLAC Summer Institute 2008 August 7, 2008

Cryogenic Detectors Direct Dark Matter Search. Dark Matter

Search for Axions with the CDMS Experiment

Dark Matter Direct Detection

Direkte Suche nach Dark Matter

CDMS and SuperCDMS. SLAC Summer Institute - CDMS. August 2, 2007 Blas Cabrera Co-Spokesperson CDMS & Spokesperson SuperCDMS

SuperCDMS at SNOLAB. What is CDMS? Technical Progress. Collaboration. Funding. Schedule and Needs. Why is SuperCDMS 25 kg timely?

Limits on spin-dependent WIMP-nucleon interactions from the Cryogenic Dark Matter Search

Searches for Low-Mass WIMPs with CDMS II and SuperCDMS

SuperCDMS: Recent Results for low-mass WIMPS

Technical Specifications and Requirements on Direct detection for Dark Matter Searches

The Cryogenic Dark Matter Search (CDMS) : Status and future. Kipac SLAC April 2009

arxiv:astro-ph/ v1 24 Jun 2004

Dark Matter Search Results from the Silicon Detectors of the Cryogenic Dark Matter Search Experiment

Recent results from the second CDMSlite run and overview of SuperCDMS SNOLAB project

Search for Inelastic Dark Matter with the CDMS experiment. Sebastian Arrenberg Universität Zürich Doktorierendenseminar 2010 Zürich,

arxiv: v1 [astro-ph.co] 4 Oct 2014

Systematics of Low Threshold Modulation Searches in CDMS II

Status of the EDELWEISS Dark Matter search

The CDMS-II Dark Matter Search and SuperCDMS

DUSEL NATIONAL LAB ROLE ESSENTIAL FOR SNOLAB AND DUSEL EXPERIMENTS SLUO

Direct Detection in the next five years: Experimental challenges and Phonon Mediated Detectors

Esperimenti bolometrici al Gran Sasso: CUORE e CRESST

SuperCDMS SNOLAB: Goals, Design, and Status. Sunil Golwala Caltech DM /02/19

The CUTE Facility. Ryan Underwood Queen s University, TRIUMF WNPPC 2019

Overview of Direct Detection Dark Matter Experiments

Looking for WIMPs A Review

Latest Results on Direct Detection of Dark Matter WIMPs - CDMS & SuperCDMS

arxiv: v1 [astro-ph.im] 18 Jan 2012

Dark Matter Searches. Marijke Haffke University of Zürich

Results from 730 kg days of the CRESST-II Dark Matter Search

Edelweiss-II : status and first results A new generation of background-free bolometers for WIMP search

Dark Matter. and TPC Technologies

Search for Low Energy Events with CUORE-0 and CUORE

Constraints on Low-Mass WIMPs from PICASSO. Carsten B. Krauss University of Alberta for the PICASSO Collaboration IDM Chicago, July

The next generation dark matter hunter: XENON1T status and perspective

The Direct Search for Dark Matter

Direct Dark Matter and Axion Detection with CUORE

Monte Carlo Comparisons to a Cryogenic Dark Matter Search Detector with low Transition-Edge-Sensor Transition Temperature

PoS(VERTEX 2009)026. Dark Matter search with Ge detectors. Paul L. Brink 1

=> Ωmatter >> Ωbaryon

Direct Search for Dark Matter

Measurement of 39 Ar in Underground Argon for Dark Matter Experiments

Sensitivity of sodium iodide cryogenic scintillation-phonon detectors to WIMP signals

Latest results of EDELWEISS II

Phonon Quasidiffusion in Cryogenic Dark Matter Search Large Germanium Detectors

The Search for Dark Matter with the XENON Experiment

Light Dark Matter and XENON100. For the XENON100 Collaboration Rafael F. Lang Columbia University

Review of dark matter direct detection experiments

Precision Measurement Of Nuclear Recoil Ionization Yields For Low Mass Wimp Searches

The EDELWEISS DM search Phase II to Phase III

David Reyna Belkis Cabrera-Palmer AAP2010, Japan

Cryodetectors, CRESST and Background

Down-to-earth searches for cosmological dark matter

LUX: A Large Underground Xenon detector. WIMP Search. Mani Tripathi, INPAC Meeting. Berkeley, May 5, 2007

Towards One Tonne WIMP Direct Detectors: Have we got what it takes?

Dark Matter Search With The PICASSO Experiment

Status of Dark Matter Detection Experiments

Direct Search for Dark Matter

The XENON1T experiment

A survey of recent dark matter direct detection results

Dark Matter -- Astrophysical Evidences and Terrestrial Searches

Dark Matter Detection and the XENON Experiment. 1 Abstract. 2 Introduction

Shedding Light on Dark Matter from Deep Underground with XENON. Kaixuan Ni (Columbia)

Status of DM Direct Detection. Ranny Budnik Weizmann Institute of Science

Direct dark matter search using liquid noble gases

DARK MATTER SEARCHES AT CANFRANC: ANAIS AND ROSEBUD: an update INTRODUCTION AND EXPERIMENTAL GOALS SUMMARY OF RECENT ACHIEVEMENTS AND EFFORTS

PoS(idm2008)010. The PICASSO Dark Matter Search Project. A. Davour for the PICASSO collaboration Queen s University

THE CRYOGENIC UNDERGROUND OBSERVATORY FOR RARE EVENTS: STATUS AND PROSPECTS

Direct Search for Dark Matter

Dark Matter search with bolometric detectors. PhD Student: Filippo Orio Dottorato in Fisica XXIII Ciclo Supervisor: prof.

Search for Weakly Interacting Massive Particles with CDMS and XENON

arxiv: v1 [physics.ins-det] 22 Dec 2016

Direct Dark Matter Searches

Background Studies for the XENON100 Experiment. Alexander Kish Physics Institute, University of Zürich Doktorandenseminar August 30, 2010 UZH

Position calibration of cryogenic dark matter detectors

Chapter 12. Dark Matter

Direct Dark Matter and Axion Detection with CUORE

Cryogenic Dark Matter Searches

Dark matter search with the SABRE experiment

COUPP: Bubble Chambers for Dark Matter Detection

Direct dark matter search with XMASS. K. Abe for the XMASS collaboration

DARWIN: dark matter WIMP search with noble liquids

Transcription:

Pushing the Limits: Dark Matter Search with Wolfgang Rau Queen s University Kingston For the Collaboration

Dark Matter Velocity Observed Zwicky Expected (Kepler) Radius Rubin Luminous Matter (< 1 %) Ordinary Matter (~ 4 %) Dark Energy (>70 %) Dark Matter (~23 %) CMB

Dark Matter Here, but not yet observed in nature: Weakly interacting WIMP (Weakly Interacting Massive Particle) Not observed in accelerator experiments: Massive Large scale structure of the Universe: Slowly moving ( cold ) Predicted by SUSY: Neutralino Universal extra dimensions: Kaluza-Klein particles

W. Rau at SNOLAB May 2012 Overview 4 Dark Matter Detection Technology Results Conclusions

W. Rau at SNOLAB May 2012 Dark Matter Detection Landscape and Background 5 Dark Matter Sensitivity (pb) 10-6 10-7 10-8 10-9 10-10 Background free 1 event /kg/d 1 event /t /7d 10 kg y 1 t y 5/t/y 10-42 10-43 10-44 10-45 10-46 Sensitivity (cm 2 ) Results Conclusion 10 10 2 10 3 10 4 10 5 10 6 Exposure (kg d)

W. Rau at SNOLAB May 2012 / Collaboration 6 California Institute of Technology Z. Ahmed, S.R. Golwala, D. Moore, R. Nelson Fermi National Accelerator Laboratory D. A. Bauer, J. Hall, D. Holmgren, L. Hsu, B. Loer, R.B. Thakur Massachusetts Institute of Technology A. J. Anderson, E. Figueroa-Feliciano, S.A. Hertel, S.W. Leman, K.A. Mccarthy NIST K. Irwin Queen s University C.H. Crewdson, P. C.F. Di Stefano, J. Fox, O. Kamaev, C. Martinez, P. Nadeau, K. Page, W. Rau, Y. Ricci, M.-A. Verdier Santa Clara University B. A. Young SLAC/KIPAC M. Asai, A. Borgland, D. Brandt, P.L. Brink,, E. Do Couto E Silva, G.L. Godrey, J. Hasi, M. Kelsey, C. J. Kenney, P. C. Kim, M.E. Monzani, R. Partridge, R. Resch, D. Wright Southern Methodist University J. Cooley, B. Karabuga, H. Qiu, S. Scorza Stanford University B. Cabrera, R. Moffat, M. Pyle, P. Redl, B. Shank, S. Yellin, J. Yen Syracuse University R. Bunker, Y. Chen, M.. Kiveni, R. W. Schnee Texas A&M R. Harris, A. Jastram, K. Koch, R. Mahapatra, J. Sander University of California, Berkeley M. Daal, T. Doughty, N. Mirabolfathi, A. Phipps, B. Sadoulet, B. Serfass, D. Speller, K.M. Sundqvist University of California, Santa Barbara D.O. Caldwell University of Colorado Denver M.E. Huber University of Florida R. Agnese, D. Balakishiyeva, T. Saab, B. Welliver Universidad Autonoma de Madrid D. Credeño, L. Esteban University of Minnesota H. Chagani, J. Beaty, P. Cushman, S. Fallows, M. Fritts, T. Hofer, V. Mandic, R. Radpour, A. Reisetter, A. Villano, J.Zhang University of Zurich S. Arrenberg, T. Bruch, L. Baudis Dark Evidence Matter Results Conclusion

W. Rau at SNOLAB May 2012 Technology Operating Principle 7 Phonon signal Charge signal Thermal bath Electron recoil Thermal coupling + + + + + + + e + - n - - - - - - - Target Phonon sensor Nuclear recoil Phonon signal: measures energy deposition Ionization signal: quenched for nuclear recoils (lower signal efficiency) Allows us to distinguish potential signal from background Ionization energy [kev eeq] Electron recoils from β s and γ s Nuclear recoils from neutrons Dark Evidence Matter Results Conclusion Phonon energy [kev]

W. Rau at SNOLAB May 2012 Cryogenic ionization detectors, Ge (Si) = 7 cm, h = 1 cm, m = 250 g (100 g) Technology Detectors Thermal readout: superconducting phase transition sensor (TES) Transition temperature: 50 100 mk 4 sensors/detector, fast signal (< ms) Charge readout: Al electrode, divided 8 Dark Evidence Matter Results Conclusion

W. Rau at SNOLAB May 2012 Technology Detector Performance 9 Ionization/Recoil energy Ionization/Recoil energy γ-band n-band Recoil energy [kev] γ-band β-band n-band Z -sensitive I onization and P honon detectors surface event rising edge slope nuclear recoil γs βs neutrons Dark Evidence Matter Results Conclusion Recoil energy [kev]

W. Rau at SNOLAB May 2012 The Family 10 1998-2002 I 6 detectors 1 kg Ge (30 kgd ) σ < 3.5e-42 cm SUF, 10 mwe 2 Soudan, 2100 mwe exposures are after all cuts! 2003-2009 2009-2013 SNOLAB, 6000 mwe II 30 detectors ~4 kg Ge (400 kgd) σ < 3.5e-44 cm 2 @ Soudan 15 detectors 10 kg Ge (~2500 kgd) σ < 5e-45 cm 2 @ SNOLAB 80-90 detectors 100 kg Ge (~35000 kgd) σ < 2e-46 cm 2 2014-2017 test facility @ SNOLAB (2011) Dark Evidence Matter Results Conclusion

W. Rau at SNOLAB May 2012 at Soudan Experimental Setup 11 Tower (6 Detectors) Cryostat, Coldbox Shielding Soudan Underground lab (2000 m w.e.) 5 Towers (~ 5 kg Ge ) operated 2006 2008 Dark Evidence Matter Results Conclusion

W. Rau at SNOLAB May 2012 Results Spin independent interaction 12 Dark Matter Data EDELWEISS 2009 XENON100 2009 2010 Dark Evidence Matter Results Conclusion

W. Rau at SNOLAB May 2012 Results Spin independent interaction 13 CRESST 2011 2010 EDELWEISS II 2011 XENON100 100d CRESST 2009 + EDELWEISS Dark Evidence Matter Results Conclusion

W. Rau at SNOLAB May 2012 DAMA/CoGeNT Low Mass WIMPs? 14 Evidence: DAMA: annual oscillation signal CoGeNT: Exponential rate increase at low energy Both have an interpretation as low mass WIMP (< 10 GeV) signal Sun Erde Dark Evidence Matter Results Conclusion

W. Rau at SNOLAB May 2012 DAMA/CoGeNT Low Mass WIMPs? 15 Evidence: DAMA: annual oscillation signal CoGeNT: Exponential rate increase at low energy Both have an interpretation as low mass WIMP (< 10 GeV) signal Data What can we () do? Lower Threshold Background increases BUT: expected WIMP rate shoots up dramatically WIMP Recoil Spectrum Dark Evidence Matter Results Conclusion Low energy extension Standard analysis range

W. Rau at SNOLAB May 2012 Low Threshold Analysis SUF and Soudan 16 Stanford Data Soudan Data Low mass WIMPs deposit little energy Study data below discrimination threshold Significant background: understood, but not subtracted Competitive sensitivity Stanford Underground Facility: early run (2001/02): very low noise, low trigger threshold (sub kev) Soudan: lower background, but slightly higher threshold (2 kev) New method of finding limit for multiple detectors with different background performance (Yellin) Dark Evidence Matter Results Conclusion

W. Rau at SNOLAB May 2012 Results Low mass WIMPs 17 Soudan 10 kev XENON 100 DAMA PICASSO CoGeNT, SUF CoGeNT interpretation by Hooper et al. Recent CoGeNT reanalysis moved region down considerably (now avoids tension with data) Dark Evidence Matter Results Conclusion

W. Rau at SNOLAB May 2012 Annual Modulation Analysis 18 5-11.9 kev nr data CoGeNT Test hypothesis that CoGeNT modulation is caused by nuclear recoils from a setupindependent source (such as dark matter) Need to convert energy scale (CoGeNT measures ionization only; uses phonon signal to determine energy) Dark Evidence Matter Results Conclusion

W. Rau at SNOLAB May 2012 Annual Modulation Analysis 19 Nuclear Recoil Hypothesis inconsistent with data What if it is Electron Recoils? Would need to go to lower energy (work in progress; checking down to 2 kev is conceivable) Dark Evidence Matter Results Conclusion

W. Rau at SNOLAB May 2012 Soudan 20 Electric Basic field configuration calculation +2 V 0 V Phonon sensors on top and Larger mass per module: ~240 g ~600 g bottom Increased thickness improved bulk/surface ratio Dark Evidence Matter Results Conclusion -2 V 0 V Improved sensor design for better event reconstruction / surface event rejection ZIP with interleaved electrodes: izip

W. Rau at SNOLAB May 2012 Soudan 21 New detectors tested underground DAQ adjusted to new requirements Increase total target mass (~10 kg) Detectors cold since November; started collecting dark matter data Improve sensitivity by ~ x5-8 210 Pb source 34,000 betas 0 events leakage Surface events Dark Evidence Matter Results Conclusion Expect limitation from cosmogenic background after 2-3 years of operation

log (Muon flux [m -2 s -1 ]) W. Rau at SNOLAB May 2012 Move to SNOLAB Less Cosmic radiation Cleaner environment Good Lab infrastructure CFI proposal submitted Concurrent proposals in US (DOE, NSF) Shileding [mwe] SNOLAB - Setup Setup at SNOLAB Detector volume holds ~ 150 kg of active target Pb/Cu shielding against external radiation PE shielding against neutrons Neutron detector (monitor internal n flux, veto neutrons interacting in Ge detectors) 22 Dark Evidence Matter Results Conclusion

Motivation Detector Test Facility Underground at SNOLAB Discrimination power required for 100 kg scale (or larger) experiments cannot be tested above ground (accidental neutron interaction rate too high) Detector modules larger than present detectors are desirable but may not be testable above ground (pile-up) Background from contamination of detectors cannot be measured above ground SUF cryostat being upgraded; installation planned in 2012 Ionization yield W. Rau at SNOLAB May 2012 Mostly neutron background Water Cryostat shield 23 Dark Evidence Matter Results Conclusion Recoil energy [kev] Sketch of Underground detector Testing Facility at SNOLAB

W. Rau at SNOLAB May 2012 at SNOLAB 24 Dark Evidence Matter Results Conclusion Ladder Lab Tentative Layout

W. Rau at SNOLAB May 2012 25 Conclusion Strong observational evidence for the existence of dark matter WIMPs are probably the best motivated candidates uses cryogenic semiconductor detector to search for WIMP interactions has provided best sensitivities for most of the past decade and continues to be among the top players So far no evidence for WIMPs has been found Low Threshold Analysis in tension with low-mass WIMP interpretation of DAMA and CoGeNT; no evidence for annual modulation in data at Soudan (~10 kg, izip detectors) being commissioned Will be limited by cosmogenic background after 2-3 years Planning 100-150 kg setup for SNOLAB Underground test facility under construction; commissioning in 2012 Dark Matter Results Conclusion