arxiv: v1 [physics.atom-ph] 24 Dec 2015

Similar documents
RILIS-ionized mercury and tellurium beams at ISOLDE CERN

Answering Questions of Nuclear and Astrophysics with Mass Measurements from ISOLTRAP

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH. Addendum to proposal P242 to the ISOLDE and Neutron Time of Flight Committee

Andree Welker ENSAR2 Town Meeting Groningen

Mass spectrometry of neutron-rich chromium isotopes into the N = 40 island of inversion

LASER SPECTROSCOPIC STUDIES OF NEUTRON-DEFICIENT EUROPIUM AND GADOLINIUM ISOTOPES

Resonant laser ionization of Po at ISOLDE

Recent developments at ISOL-based facilities. Piet Van Duppen KU Leuven, Belgium

CHAPTER VI RIB SOURCES

Trap assisted decay spectroscopy setup at ISOLTRAP

Ultra-Pure 163 Ho Samples for Neutrino Mass Measurements

Novel radioactive ion-beam production techniques Report on new schemes and novel laser-ion-source techniques

Review of ISOL-type Radioactive Beam Facilities

LIST - Development at Mainz for ISOLDE

In-trap decay and trap-assisted decay spectroscopy at ISOLTRAP

CHAPTER VI RIB SOURCES

JRA-4: RESIST RESonance Ionization techniques for SeparaTors. Spokesperson: Iain Moore, JYFL Deputy: Valentin Fedosseev, CERN

Laser spectroscopy studies of neutron-rich nuclei

Discovery of 229 Rn and the Structure of the Heaviest Rn and Ra Isotopes from Penning-Trap Mass Measurements

In-gas cell laser spectroscopy of neutron-deficient silver isotopes

Principle of Resonance Ionization

Results from the collinear laser spectroscopy collaboration at ISOLDE-CERN

Isobar separation and precision mass spectrometry of short-lived nuclides with a multi-reflection time-of-flight analyzer

Investigation of Water Fragments

ECT* Trento The Lead Radius. Precision measurements of nuclear ground state properties for nuclear structure studies. Klaus Blaum

Opportunities with collinear laser spectroscopy at DESIR:

KEK isotope separation system for β-decay spectroscopy of r-process nuclei

Nuclear Masses and their Importance for Nuclear Structure, Astrophysics and Fundamental Physics

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH. Letter of Intent to the ISOLDE and Neutron Time-of-Flight Committee

Why Make Rare Isotopes?

ISCC meeting, February 16, ISCC meeting, February 16, ISOLDE ISOLDE scientific scientific coordinator s s report

Atomic Physics with Stored and Cooled Ions

beta-nmr: from nuclear physics to biology

Early onset of deformation in the neutron-deficient polonium isotopes identified by in-source resonant ionization laser spectroscopy

Addendum to the IS534 Proposal

Report on novel techniques for the production and selection of ECRionized radioactive ions beams

EBSS: Hands-on Activity #8. Operation of an electromagnetic isotope separator (EMIS) Dan Stracener Jon Batchelder

Early onset of deformation in the neutron-deficient polonium isotopes identified by in-source resonant ionization laser spectroscopy

Laser spectroscopy and resonant laser ionization atomic tools to probe the nuclear landscape. Iain Moore University of Jyväskylä, Finland

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH. Proposal to the ISOLDE and Neutron Time-of-Flight Committee

Status of the SHIPTRAP Project: A Capture and Storage Facility for Heavy Radionuclides from SHIP

C. Seiffert a, J.Ballof a,b, for the ISBM working group, Andrei Andreyev c,d, Ch. E. Düllmann b,e,f, Ulli Köester g, A.

Determination of the electron affinity of astatine and polonium by laser photodetachment

Neutral beam plasma heating

Laser Spectroscopy on Bunched Radioactive Ion Beams

The Collinear Resonance Ionization Spectroscopy (CRIS) experimental setup at CERN-ISOLDE

A Multi-beamlet Injector for Heavy Ion Fusion: Experiments and Modeling

FAIR - A Status Report + A Concept for Collinear Spectroscopy at TRIGA Mainz. Wilfried Nörtershäuser GSI Darmstadt & Universität Mainz

Abstract... I. Acknowledgements... III. Table of Content... V. List of Tables... VIII. List of Figures... IX

Project of RIC-80 facility at PNPI for medical isotope production

5-A / 9, WEA, Sat Nagar, Karol Bagh New Delhi Web:

Figure 1: The current target chamber and beam diagnostic station for the NDCX-I beamline will be used during commissioning of NDCX-II in 2012

GSI. Overview of last years activities: technical developments and investigations mass measurements. TRAPSPEC related tasks and issues

Present and Future of Fission at n_tof

Cesium Dynamics and H - Density in the Extended Boundary Layer of Negative Hydrogen Ion Sources for Fusion

The Gamma Factory proposal for CERN

High power molten targets for the production of radioactive ion beams

Ionization Techniques Part IV

Beam Extraction by the Laser Charge Exchange Method Using the 3-MeV LINAC in J-PARC )

Target and Ion Source Development for Better Beams in the ARIEL Era

Status of the EBIT in the ReA3 reaccelerator at NSCL

Volume Production of D - Negative Ions in Low-Pressure D 2 Plasmas - Negative Ion Densities versus Plasma Parameters -

1 AT/P5-05. Institute of Applied Physics, National Academy of Sciences of Ukraine, Sumy, Ukraine

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH. Letter of Intent to the ISOLDE and Neutron Time-of-Flight Committee

The Island of of Inversion from a nuclear moments perspective

Chapter V: Interactions of neutrons with matter

Atomic Physics with Stored and Cooled Ions

Towards TASCA

In-Gas Laser Ionization and Spectroscopy experiments at S 3 -GANIL

4 FEL Physics. Technical Synopsis

Rb, which had been compressed to a density of 1013

Photoelectron Spectroscopy using High Order Harmonic Generation

Production of HCI with an electron beam ion trap

FREE-ELECTRON LASER FACILITY(U) NATIONAL BUREAU OF STANDARDS GAITHERSBURG NO P H DEBENHdAN ET AL UNCLASSIFIED F/G 14/2 NI

Effect of Magnetic Filter in a Volume Production Multicusp Ion Source

Accelerated radioactive beams and the future of nuclear physics. David Jenkins

Laser Spectroscopy of neutron-deficient Sn isotopes

THE SUPER-FRS PROJECT AT GSI

NIST Research on Spectroscopy and Collisional-Radiative Modeling of Highly-Charged Ions of Tungsten

Nuclear Structure Studies along the Z=28 and 82 Closed Proton Shells using Radioactive Ion Beams

RDCH 702 Lecture 8: Accelerators and Isotope Production

CW-Lyman- Source for Laser Cooling of Antihydrogen in a Magnetic Trap

ACCELERATION, DECELERATION AND BUNCHING OF STORED AND COOLED ION BEAMS AT THE TSR, HEIDELBERG

TEST MEASUREMENTS WITH THE REX-ISOLDE LINAC STRUCTURES*

Introduction to REX-ISOLDE concept and overview of (future) European projects

Measurement of shifts in the electron affinities of chlorine isotopes

Theory of Gas Discharge

The rest of topic 11 INTRODUCTION TO ORGANIC SPECTROSCOPY

Precision Mass Measurements of Cd and Their Impact on Stellar Nucleosynthesis via the Rapid Neutron Capture Process

arxiv: v2 [physics.acc-ph] 21 Jun 2017

Laser Dissociation of Protonated PAHs

Beam Diagnostics and Instrumentation JUAS, Archamps Peter Forck Gesellschaft für Schwerionenforschnung (GSI)

Laser Physics OXFORD UNIVERSITY PRESS SIMON HOOKER COLIN WEBB. and. Department of Physics, University of Oxford

Status & Plans for the TRIUMF ISAC Facility

Nuclear Instruments and Methods in Physics Research A

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

ATOMIC AND LASER SPECTROSCOPY

Mass Determination of Rn and Hg isotopes using MASHA

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Cross-section Measurements of Relativistic Deuteron Reactions on Copper by Activation Method

Transcription:

Identification of autoionizing states of atomic chromium for resonance photo-ionization at the ISOLDE-RILIS arxiv:1512.07875v1 [physics.atom-ph] 24 Dec 2015 Abstract T. Day Goodacre* a,b, K. Chrysalidis a,d, D. Fedorov c, V. N. Fedosseev a, B. A. Marsh a, P. Molkanov c, R. E. Rossel a,d,e, S. Rothe a, C. Seiffert a a CERN, CH-1211 Geneva 23, Switzerland b School of Physics and Astronomy, The University of Manchester, Manchester, M13 9PL, United Kingdom c Petersburg Nuclear Physics Institute, 188350 Gatchina, Russia d Institut für Physik, Johannes Gutenberg Universität, D-55099 Mainz, Germany e Faculty of Design, Computer Science and Media, Hochschule RheinMain, Wiesbaden, Germany The resonance ionization laser ion source (RILIS) is the principal ion source of the ISOLDE radioactive beam facility based at CERN. Using the method of insource resonance ionization spectroscopy, an optimal three-step, three-resonance photo-ionization scheme has been developed for chromium. The scheme uses an ionizing transition to one of the 14 newly observed autoionizing states. This work increases the range of ISOLDE-RILIS ionized beams to 32 chemical elements. Details of the spectroscopic studies are described and the new ionization scheme is summarized. A link to the complete version of this document will be added here following publication: Keywords: RILIS, ISOLDE, chromium, autoionizing, laser ionization 1. Introduction 1.1. The ISOLDE-RILIS ISOLDE is an isotope separator on-line (ISOL) type, radioactive ion beam facility connected to the CERN accelerator complex [1]. Radionuclides are produced with a pulsed 1.4 GeV proton beam of up to 2 µa average current that is impacted upon a thick target. Reaction products, created via fragmentation, spallation and fission, are stopped and thermalized within the target material. The thomas.day.goodacre@cern.ch Preprint submitted to arxiv August 15, 2018

target is heated to enable sufficiently volatile elements to diffuse through the target material and then effuse, via a transfer line, to an ion source typically for 1+ ionization. The resonance ionization laser ion source (RILIS) is the principal ion source of the ISOLDE facility, used for 75% of the ISOLDE physics experiments in 2015. The hot cavity RILIS operation at ISOLDE is based on the following three principles: 1. The distribution of the atomic energy levels is unique to a particular element. 2. Electric dipole transitions between electronic states of the atom can be driven by an external photon field, when the photon energy corresponds to the transition energy. 3. Ions in the hot cavity environment (typically a 3 mm internal diameter metal tube heated up to 2400 K) are transversally confined by the cavity walls, which are positively charged as a result of thermally induced electron emission, enhancing ion survival rates. The RILIS targets a progressive series of resonant atomic excitations, using multiple tunable lasers, before a final ionizing step: either a resonant transition to an autoionizing state or non-resonant ionization to the continuum [2]. Ionization via an autoionizing resonance is preferred as the photo-absorption cross-section for resonant transitions can be orders of magnitude higher than for non-resonant ionization, often making saturation of the transition feasible with the typically available laser power [3]. The development of a RILIS scheme for chromium was initiated following interest from the ISOLDE solid state physics group and the ISOLTRAP collaboration for experiments involving neutron deficient and neutron rich isotopes respectively [4, 5]. Previous chromium production at ISOLDE used arc discharge ion sources, most recently a VD5 hot plasma variant of the ISOLDE Versatile Arc Discharge Ion Source (VADIS), coupled to a ZrO 2 or a Y 2 O 3 target [6]. The universal ionization efficiency of the VD5 VADIS limits the achievable beam purity for some isotopes due to isobaric contamination, particularly if a UC X target is used [7]. A viable RILIS scheme therefore enhances the purity of chromium ion beams. In addition to offering the other advantages of element selective ionization with the RILIS, such as the ability to remove the laser ionized chromium component of the ion beam by blocking one of the resonant transitions, enabling measurements to be made both with the lasers blocked and unblocked for signal identification. 2

2. Ionization of chromium atoms in a hot cavity Chromium has a first ionization potential of 6.77 ev [8]. Consequently, with sufficient heating of the sample of stable chromium, a surface ion signal measurable on an ISOLDE Faraday cup (>100 fa) is expected from a tungsten hot cavity ion source heated to 2400 K. 3. Experimental set-up The RILIS scheme development for chromium took place at ISOLDE using the RILIS laser system and a tungsten hot cavity ion source mounted on the general purpose separator (GPS) frontend. The ISOLDE-RILIS is primarily made up of broadly tunable lasers to maximize the spectral range and flexibility of the of the system, with a combination of three dye lasers and three Titanium:Sapphire (Ti:Sa) lasers. An independent 40 W average power, TEM 00, frequency doubled Nd:YVO 4 (532 nm) Lumera Blaze laser, is available for ionization schemes using a non-resonant final ionizing step [9]. The lasers are pulsed at a repetition rate of 10 khz, approximately the frequency required to ensure atoms effusing through the ion source are illuminated by a minimum of one set of laser pulses. The tunable lasers are typically pumped by frequency doubled Nd:YAG (532 nm) lasers; however, the dye lasers can also be pumped with the third harmonic of the Nd:Yag (355 nm) to extend their possible tuning range. Through the use of non-linear optics for 2nd, 3rd and 4th harmonic generation, an unbroken spectral coverage between 210 nm and 950 nm is achieved. The wavelengths of the RILIS lasers are measured using a HighFinesse/Ångstrom WS7 wavelength meter. Two dye lasers, one frequency doubled Ti:Sa laser and the 532 nm Blaze laser, highlighted in the schematic of the RILIS laser system presented in Figure 1, were used during the scheme development of chromium. For RILIS scheme development, capillary mass markers loaded with stable isotopes of the element of interest are connected to the rear of a hot cavity, providing a continuous supply of atoms within the ion source as they are heated and evaporated. As depicted in Figure 1, the RILIS laser beams were directed through the GPS dipole magnet, to converge within the hot cavity ion source. The ion source assembly was maintained at a voltage of 30 kv and a grounded extraction electrode was positioned 60 mm from the exit of the ion source. Ions created in the ion source drifted towards the cavity exit under the influence of a longitudinal voltage drop resulting from the resistive heating of the hot cavity. At the exit of the hot cavity, the ions were extracted by the penetrating field of the extraction 3

Figure 1: Schematic of the RILIS layout and the experimental set-up for the development of a RILIS scheme for chromium electrode and accelerated to form a 30 kev ion beam. The ions passed through the ISOLDE GPS dipole magnet for mass selection before being directed to a Faraday cup for measurement of the ion current. The 357.9 nm light for the first step transition was produced by frequency doubling the output of a Ti:Sa laser and the 697.8 nm light for the second step transition was produced by a dye laser containing Pyridine 1 dye dissolved in ethanol. A second dye laser, containing Rhodamine 6G dye dissolved in ethanol, was used applied as a third excitation step to above the first ionization potential and scanned to search for autoionizing states. The 52 Cr (stable) ion current was measured whilst recording the scanning laser wavelength using the RILIS data acquisition system [10]. Since the purpose of the spectroscopic study was the identification of an optimal RILIS scheme for chromium beam production at ISOLDE, typical RILIS operating conditions were maintained (laser linewidths and power levels were not optimized for spectral resolution). The RILIS laser parameters are described in detail by Fedosseev et al. and Rothe et al. [11, 12]. 4. Results and discussion The procedure used for laser resonance ionization scheme development for the ISOLDE-RILIS was reviewed by Fedosseev et al. [13]. According to Boltzmann s equation, the 3d 5 ( 6 S)4s a 7 S 3 atomic ground state of chromium is 97 % populated at 2400 K. Thus, all of the RILIS schemes considered here 4

originate from the atomic ground state. Extensive atomic line data is available for chromium, including numerous autoionizing states [14, 8, 15]. Following a review of these atomic lines and energy levels, suitable first and second steps for a RILIS scheme were identified, details of the transitions are presented in Table 1. Table 1: The first and second resonant transitions used in the chromium scheme development. Spectroscopic information is taken from NIST database [8] Transition Upper state config., term, J Wavenumber Air wavelength (cm 1 ) (cm 1 ) (nm) 0-27935 3d 4 ( 5 D)4s4p 3 P, y 7 P, 4 27935 357.9 27935-42261 3d 5 ( 6 S)4d, e 7 D, 5 14325 697.8 The upper level of the second transition lies at an energy of 42261 cm-1, 12314 cm 1 ( 812 nm) below the ionization threshold [8]. When considering the suitability of a transition, information concerning the photoabsorption crosssection of the candidate transition was compared to similar data for transitions used in existing RILIS schemes, for which a saturation measurement has been performed. This provides a reliable estimate of the feasibility of saturating a proposed transition with the laser power that is typically available from the RILIS lasers. Where available, an excitation scheme consisting of states with progressively increasing statistical weights is preferred, as this increases the maximum achievable ionization efficiency in the RILIS ionization geometry. Initially a three step, two resonance scheme, with a non-resonant final step at 532 nm was demonstrated ({λ 1 λ 2 λ 3 } = {357.9 nm 697.8 nm 532 nm NR }), verifying the suitability of the transitions found in literature. The non-resonant final step was then replaced with the tunable dye laser containing Rhodamine 6G dye dissolved in ethanol to excite from the 3d 5 ( 6 S)4d e 7 D 5 level at 42261 cm 1 and scan above the ionization potential. 14 new autoionizing states were observed in the scan between 17204 cm 1 and 17854 cm 1. The optimal scheme, corresponding to the highest observed 52 Cr ion current, is presented in Figure 2, along with laser scans of the three resonances. Time constraints limited the investigation of saturation levels to only the Table 2: An autoionizing states of chromium, accessed by a single photon transition from the 3d 5 ( 6 S)4d e 7 D 5 level at 42261 cm 1. Energy Transition Air wavelength (cm 1 ) (cm 1 ) (nm) 59523 17262 579.1 5

Figure 2: The optimal RILIS ionization scheme for chromium and scans of the three resonant transitions. {357.9 nm 697.8 nm 579.1 nmai } scheme. The saturation of the first two resonant transitions was verified and a saturation measurement of the third resonant transition was made by measuring the 52 Cr ion current while varying the third step laser power, the transition was not saturated with an estimated 1.3 W of laser light transmitted to the ion source. A redistribution of the pump laser power for the dye lasers could enable up to 7 W of laser power at 579 nm to be delivered to the ion source, increasing the total efficiency of the scheme. Using the scheme depicted in Figure 2, a laser to surface ionization ratio of 2200:1 was recorded with the hot cavity heated to 2400 K. The ion signal when applying the {357.9 nm 697.8 nm 579.1 nmai } scheme, was a factor of two greater than the ion signal observed when using the {357.9 nm 697.8 nm 532 nmnr } scheme with non-resonant ionization despite an estimated 24 W of 532 nm laser light transmitted to the ion source. Chromium extraction from ISOLDE UCx targets has been verified, using surface ionization, as far in to the neutron rich region as 59 Cr [16]. This demonstrates the possibility of extracting chromium isotopes with half lives of the order of 100 ms. The validity of the new RILIS scheme has been demonstrated on-line at ISOLDE with the measurement of RILIS ionized, radiogenically produced 52 Cr. A factor of 800 enhancement of the ion signal was observed, from an ion beam composed of multiple elements with the line heated to 2400 K. 6

5. Conclusion 14 new autoionizing states of chromium have been observed, during off-line testing at the ISOLDE-RILIS. From this work, an optimal {357.9 nm 697.8 nm 579.1 nm AI } RILIS scheme was identified. The scheme was verified on-line at ISOLDE, using radiogenically produced chromium from a UC X target. As a result, RILIS ionized chromium beams are now available for experiments at ISOLDE. 6. Acknowledgements This project has received funding through the European Unions Seventh Framework Programme for Research and Technological Development under Grant Agreements 262010 (ENSAR), 267194 (COFUND), and 289191 (LA 3 NET). References [1] E. Kugler. The ISOLDE facility. Hyperfine Interactions, 129(1/4):23 42, 2000. [2] V S Letokhov. Laser Photoionization Spectroscopy. ACADEMIC PRESS INC., London, 1 edition, 1987. [3] V.I. Mishin, V.N. Fedoseyev, H.-J. Kluge, V.S. Letokhov, H.L. Ravn, F. Scheerer, Y. Shirakabe, S. Sundell, and O. Tengblad. Chemically selective laser ion-source for the CERN-ISOLDE on-line mass separator facility. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 73(4):550 560, April 1993. [4] K Johnston. Private communication. Technical report, ISOLDE, Geneva, 2015. [5] S. Kreim, D. Beck, K. Blaum, Ch. Bohm, Ch. Borgmann, M. Breitenfeldt, R. B. Cakirli, F. Herfurth, M. Kowalska, Y. Litvinov, D. Lunney, V. Manea, S. Naimi, D. Neidherr, M. Rosenbusch, L. Schweikhard, J. Stanja, T. Stora, F. Wienholtz, Wolf R. N., and K. Zuber. Seeking the Purported Magic Number N = 32 with High-Precision Mass Spectrometry. Technical report, CERN-INTC, Geneva, 2011. 7

[6] T. Stora. Recent developments of target and ion sources to produce ISOL beams. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 317:402 410, December 2013. [7] R. Kirchner. Progress in ion source development for on-line separators. Nuclear Instruments and Methods in Physics Research, 186(1-2):275 293, July 1981. [8] A. Kramida, Yu. Ralchenko, J. Reader, and the NIST ASD Team. NIST Atomic Spectra Database (ver. 5.2), [Online], 2014. [9] B. Marsh, T. Day Goodacre, D. Fink, S. Rothe, M. Seliverstov, N. Imai, M. Sjodin, and R. Rossel. Suitability test of a high beam quality Nd:YVO4 industrial laser for the ISOLDE RILIS installation. Technical report, CERN, Geneva, 2013. [10] R. E. Rossel, V. N. Fedosseev, B. A. Marsh, D. Richter, S. Rothe, and K. D. A. Wendt. Data acquisition, remote control and equipment monitoring for ISOLDE RILIS. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 317:557 560, December 2013. [11] V. N. Fedosseev, L.-E. Berg, D. V. Fedorov, D. Fink, O. J. Launila, R. Losito, B. A. Marsh, R. E. Rossel, S. Rothe, M. D. Seliverstov, A. M. Sjodin, and K. D. A. Wendt. Upgrade of the resonance ionization laser ion source at ISOLDE on-line isotope separation facility: New lasers and new ion beams. Review of Scientific Instruments, 83(2):02A903, 2012. [12] S. Rothe, T. Day Goodacre, V. N. Fedosseev, B. A. Marsh, R. E. Rossel, M. Veinhard, and K. D. A. Wendt. Laser ion beam production at CERN- ISOLDE: new features - more possibilities. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, (Proceedings of The International Conference on Electromagnetic Isotope Separators and Related Topics (EMIS), Grand Rapids, Michigan, USA, May 11-15). [13] V. N. Fedosseev, B. A. Marsh, D. V. Fedorov, U. Köster, and E. Tengborn. Ionization Scheme Development at the ISOLDE RILIS. In Laser 2004, pages 15 27. Springer-Verlag, Berlin/Heidelberg, 2005. 8

[14] P. L. Smith, H. Claas, J. R. Esmond, and R. L. Kurucz. Atomic spectral line database. [15] E. B. Saloman. Energy Levels and Observed Spectral Lines of Neutral and Singly Ionized Chromium, Cr I and Cr II. Journal of Physical and Chemical Reference Data, 41(4):043103, 2012. [16] N. Althubiti, P. Ascher, D. Atanasov, D. Beck, K. Blaum, M. Breitenfeldt, R. B. Cakiril, T. E. Cocolios, S. Eliseev, T. Eronen, S. George, F. Herfurth, A. Herlert, M. Kowalska, S. Kreim, Yu. A. Litvinov, D. Lunney, V. Manea, E. Minaya Ramirez, S. Naimi, D. Neidherr, M. Rosenbusch, A. de Roubin, L. Schweikhard, A. Welker, F. Wienholtz, R. N. Wolf, and K. Zuber. IS532: Mass spectrometry of neutron-rich nuclides into the N = 40 island of inversion. Technical report, CERN-INTC, Geneva, 2015. 9