METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE)

Similar documents
SOUTH AFRICAN NATIONAL STANDARD

METHOD 9200 NITRATE. 1.2 The applicable range of concentration is 0.1 to 2 mg NO -N per liter. 3 of sample.

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

METHOD 9035 SULFATE (COLORIMETRIC, AUTOMATED, CHLORANILATE)

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

METHOD 9012 TOTAL AND AMENABLE CYANIDE (COLORIMETRIC, AUTOMATED UV)

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

INTERNATIONAL STANDARD

METHOD 9012B TOTAL AND AMENABLE CYANIDE (AUTOMATED COLORIMETRIC, WITH OFF-LINE DISTILLATION)

Sodium Chloride - Analytical Standard

LEAD (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 500 C

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

METHOD #: Approved for NPDES and SDWA (Ed. Rev. 1974, 1978) Fluoride, Total (Colorimetric, SPADNS with Bellack Distillation)

Standard Methods for the Examination of Water and Wastewater

METHOD 9034 TITRIMETRIC PROCEDURE FOR ACID-SOLUBLE AND ACID INSOLUBLE SULFIDES

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

National standard of People s Republic of China

Spectrophotometric Determination of Ferrocyanide in Effluents

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

ALLOWAY METHOD OUTLINE

METHOD 9010B TOTAL AND AMENABLE CYANIDE: DISTILLATION

METHOD 9077 TEST METHODS FOR TOTAL CHLORINE IN NEW AND USED PETROLEUM PRODUCTS (FIELD TEST KIT METHODS)

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Scope and application: For wastewater, seawater, drinking water, surface water and process water.

Persulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials

METHOD 7199 DETERMINATION OF HEXAVALENT CHROMIUM IN DRINKING WATER, GROUNDWATER AND INDUSTRIAL WASTEWATER EFFLUENTS BY ION CHROMATOGRAPHY

Chemistry 119: Experiment 6. Sampling and Analysis of a Solid Drain Cleaner

Method to 0.50 mg/l NH 3 N Powder Pillows

Cyanide, colorimetric, pyridine-pyrazolone

METHOD 9076 DETERMINATION OF INORGANIC ANIONS BY ION CHROMATOGRAPHY PRODUCTS BY OXIDATIVE COMBUSTION AND MICROCOULOMETRY

Method to 0.50 mg/l NH 3 N Powder Pillows

Persulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials

Sodium Chloride - Analytical Standard

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

AP Chemistry Unit 2 Test (Chapters 3 and 4)

SOUTH AFRICAN NATIONAL STANDARD. Standard test methods for lead in water

CH2MHILL GILROY/MORGAN HILL LABORATORY LABORATORY STANDARD OPERATING PROCEDURE NO TOTAL KJELDAHL NITROGEN - TKN SM 4500-N org.

RAPID KJELDAHL BENCHNOTES

Standard Methods for the Examination of Water and Wastewater

Nitrogen, Ammonia. Test Preparation. Powder Pillows Method Method 8155 Salicylate Method 1 Powder Pillows

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

Glossary of Common Laboratory Terms

Quaternary Ammonium Compounds

METHOD #: Approved for NPDES (Technical Revision 1980) Cyanide, Total (Titrimetric; Spectrophotometric)

Nitrogen, ammonia, colorimetry, salicylate-hypochlorite, automated-segmented flow

SECTION D.2 AMMONIA NITROGEN

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

METHOD 3510B SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

Mercuric Thiocyanate Method Method to 25.0 mg/l Cl Reagent Solution

Standard Test Methods for Acidity or Alkalinity of Water 1

Standard Methods for the Examination of Water and Wastewater

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

SIDE BY SIDE COMPARISON TABLE FOR HACH METHOD NUMBER COLORIMETRIC DETERMINATION OF CYANIDE

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

DR/4000 PROCEDURE NITRATE. 2. The display will show:

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

LACTIC ACID. The method is applicable to the determination of lactic acid and lactate salts (Note 2) in light or heavy steepwater.

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

EXPERIMENT NINE Part I - The Standardization of Thiosulfate Solutions

Chemical Analysis Instruction Book

METHOD 7B - DETERMINATION OF NITROGEN OXIDE EMISSIONS FROM STATIONARY SOURCES (ULTRAVIOLET SPECTROPHOTOMETRIC METHOD)

Some data and solubility information for Sodium Chlorate

APCH 231 CHEMICAL ANALYSIS PRECIPITATION TITRATIONS

METHOD 3520C CONTINUOUS LIQUID-LIQUID EXTRACTION

Standard Test Method for Aluminum in Water 1

Standard Operating Procedure for GLNPO Specific Conductance: Conductivity Bridge

Chapter Four. Chapter Four. Chemical Reactions in Aqueous Solutions. Electrostatic Forces. Conduction Illustrated

METHOD 9020B TOTAL ORGANIC HALIDES (TOX)

Identification of ions and gases

DR/4000 PROCEDURE SELENIUM. 4. Measure 100 ml of sample into a second 500-mL erlenmeyer flask (label the flask sample ).

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

Graphene oxide was synthesized from graphite using the MH (modified Hummer s method) 30 and

Cadmium Reduction Method (Using Powder Pillows or AccuVac Ampuls)

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Stoichiometry ( ) ( )

Chemistry Determination of Mixed Acids

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

Nitrate plus Nitrite and Nitrite in Seawater by Segmented Flow Analysis (SFA)

Contact Person(s) : Anna Berne APPLICATION

SPECIFICATION & TEST PROCEDURE SODIUM SALICYLATE Technical. Molecular weight : Reference : In-house

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Advanced Subsidiary Level and Advanced Level

Titrimetric Determination of EASTMAN Color Developing Agent, CD-3, in Process ECN-2 Developer with Sulfato Cerate

Application Note #119 Alkalinity and Chloride by Titration

BUREAU OF INDIAN STANDARDS. Draft Indian Standard. SPECIFICATION FOR BASIC CHROMIUM SULPHATE (FOR TANNING) (First revision of IS 6301) ICS:

The table shows the results of some tests carried out on three solutions, A, B and C. Hydrochloric acid is added. Solution

Page 2. Q1.A student investigated food dyes using paper chromatography. This is the method used.

Application Note #97 Alkalinity and Hardness by Potentiometric Titration Using TRIS Buffer

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certifi cate of Education Advanced Subsidiary Level and Advanced Level

ASTM Designation: D Standard Test Method for Determination of Iodine Number of Activated Carbon

NICKEL-63/59 IN WATER

Unit 3 Chemistry - Volumetric Analysis

Transcription:

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE) 1.0 SCOPE AND APPLICATION 1.1 This method is applicable to ground water, drinking, surface, and saline waters, and domestic and industrial wastes. 1.2 The method is suitable for all concentration ranges of chloride content; however, in order to avoid large titration volume, a sample aliquot - containing not more than 10 to 20 mg Cl per 50 ml is used. 1. Automated titration may be used. 2.0 SUMMARY OF METHOD 2.1 An acidified sample is titrated with mercuric nitrate in the presence of mixed diphenylcarbazone-bromophenol blue indicator. The end point of the titration is the formation of the blue-violet mercury diphenylcarbazone complex..0 INTERFERENCES.1 Anions and cations at concentrations normally found in surface waters do not interfere. However, at the higher concentration often found in certain wastes, problems may occur..2 Sulfite interference can be eliminated by oxidizing the 50 ml of sample solution with 0.5-1 ml of H O. 2 2. Bromide and iodide are also titrated with mercuric nitrate in the same manner as chloride..4 Ferric and chromate ions interfere when present in excess of 10 mg/l. 4.0 APPARATUS AND MATERIALS 4.1 Standard laboratory titrimetric equipment, including 1 ml or 5 ml microburet with 0.01 ml gradations. 4.2 Class A volumetric flasks: 1 L and 100 ml. 4. ph Indicator paper. 4.4 Analytical balance: capable of weighing to 0.0001 g. 5.0 REAGENTS CD-ROM 9252A - 1 Revision 1

5.1 Reagent-grade chemicals shall be used in all tests. Unless otherwise indicated, it is intended that all reagents shall conform to the specifications of the Committee on Analytical Reagents of the American Chemical Society, where such specifications are available. Other grades may be used, provided it is first ascertained that the reagent is of sufficiently high purity to permit its use without lessening the accuracy of the determination. 5.2 Reagent water. All references to water in this method refer to reagent water, as defined in Chapter One. 5. Standard sodium chloride solution, 0.025 N: Dissolve 1.461 g + 0.0002 g of sodium chloride (dried at 600EC for 1 hr) in chloride-free water in a 1 liter Class A volumetric flask and dilute to the mark with reagent water. 5.4 Nitric acid (HNO ) solution: Add.0 ml concentrated nitric acid to 997 ml of reagent water (" + 997" solution). 5.5 Sodium hydroxide (NaOH) solution (10 g/l): Dissolve approximately 10 g of NaOH in reagent water and dilute to 1 L with reagent water. 5.6 Hydrogen peroxide (H O ): 0%. 2 2 5.7 Hydroquinone solution (10 g/l): Dissolve 1 g of purified hydroquinone in reagent water in a 100 ml Class A volumetric flask and dilute to the mark. 5.8 Mercuric nitrate titrant (0.141 N): Dissolve 24.2 g Hg(NO ) 2 H2O in 900 ml of reagent water acidified with 5.0 ml concentrated HNO in a 1 liter volumetric flask and dilute to the mark with reagent water. Filter, if necessary. Standardize against standard sodium chloride solution (Step 5.) using the procedures outlined in Sec. 7.0. Adjust to exactly 0.141 N and check. Store in a dark bottle. A 1.00 ml aliquot is equivalent to 5.00 mg of chloride. 5.9 Mercuric nitrate titrant (0.025 N): Dissolve 4.280 g Hg(NO ) 2 H O in 50 ml of reagent water acidified with 0.05 ml of concentrated 2 HNO (sp. gr. 1.42) in a 1 liter volumetric flask and dilute to the mark with reagent water. Filter, if necessary. Standardize against standard sodium chloride solution (Sec. 5.) using the procedures outlined in Sec. 7.0. Adjust to exactly 0.025 N and check. Store in a dark bottle. 5.10 Mercuric nitrate titrant (0.0141 N): Dissolve 2.4200 g Hg(NO ) 2 H2O in 25 ml of reagent water acidified with 0.25 ml of concentrated HNO (sp. gr. 1.42) in a 1 liter Class A volumetric flask and dilute to the mark with reagent water. Filter, if necessary. Standardize against standard sodium chloride solution (Sec. 5.) using the procedures outlined in Sec. 7.0. Adjust to exactly 0.0141 N and check. Store in a dark bottle. A 1 ml aliquot is equivalent to 500 µg of chloride. 5.11 Mixed indicator reagent: Dissolve 0.5 g crystalline diphenylcarbazone and 0.05 g bromophenol blue powder in 75 ml 95% ethanol in a 100 ml Class A volumetric flask and dilute to the mark with 95% ethanol. Store in brown bottle and discard after 6 months. CD-ROM 9252A - 2 Revision 1

5.12 Alphazurine indicator solution: Dissolve 0.005 g of alphazurine blue-green dye in 95% ethanol or isopropanol in 100 ml Class A volumetric flask and dilute to the mark with 95% ethanol or isopropanol. 6.0 SAMPLE COLLECTION, PRESERVATION, AND HANDLING 6.1 All samples must have been collected using a sampling plan that addresses the considerations discussed in Chapter Nine of this manual. 6.2 There are no special requirements for preservation. 7.0 PROCEDURE 7.1 Place 50 ml of sample in a vessel for titration. If the concentration is greater than 20 mg/l chloride, use 0.141 N mercuric nitrate titrant (Sec. 5.8) in Sec. 7.6, or dilute sample with reagent water. If the concentration is less than 2.5 mg/l of chloride, use 0.0141 N mercuric nitrate titrant (Sec. 5.10) in Sec. 7.6. Using a 1 ml or 5 ml microburet, determine an indicator blank on 50 ml chloride-free water using Sec. 7.6. If the concentration is less than 0.1 mg/l of chloride, concentrate an appropriate volume to 50 ml. 7.2 Add 5 to 10 drops of mixed indicator reagent (Sec. 5.11); shake or swirl solution. 7. If a blue-violet or red color appears, add HNO solution (Sec. 5.4) dropwise until the color changes to yellow. Proceed to Sec. 7.5. 7.4 If a yellow or orange color forms immediately on addition of the mixed indicator, add NaOH solution (Sec. 5.5) dropwise until the color changes to blue-violet; then add HNO solution (Sec. 5.4) dropwise until the color changes to yellow. 7.5 Add 1 ml excess HNO solution (Sec. 5.4). 7.6 Titrate with 0.025 N mercuric nitrate titrant (Sec. 5.9) until a blue-violet color persists throughout the solution. If volume of titrant exceeds 10 ml or is less than 1 ml, use the 0.141 N or 0.0141 N mercuric nitrate solutions, respectively. If necessary, take a small sample aliquot. Alphazurine indicator solution (Sec. 5.12) may be added with the indicator to sharpen the end point. This will change color shades. Practice runs should be made. Note: The use of indicator modifications and the presence of heavy metal ions can change solution colors without affecting the accuracy of the determination. For example, solutions containing alphazurine may be bright blue when neutral, grayish purple when basic, blue-green when acidic, and blue-violet at the chloride end point. Solutions containing about 100 mg/l nickel ion and normal mixed indicator are purple when neutral, green when acidic, and gray at the chloride end point. When applying this method to samples that contain colored ions or that require modified indicator, it is recommended that the operator become familiar with the specific color changes involved by experimenting with solutions prepared as standards for comparison of color effects. CD-ROM 9252A - Revision 1

7.6.1 If chromate is present at <100 mg/l and iron is not present, add 5-10 drops of alphazurine indicator solution (Sec. 5.12) and acidify to a ph of (indicating paper). End point will then be an olivepurple color. 7.6.2 If chromate is present at >100 mg/l and iron is not present, add 2 ml of fresh hydroquinone solution (Sec. 5.7). 7.6. If ferric ion is present use a volume containing no more than 2.5 mg of ferric ion or ferric ion plus chromate ion. Add 2 ml fresh hydroquinone solution (Sec. 5.7). 7.6.4 If sulfite ion is present, add 0.5 ml of HO solution (Sec. 2 2 5.6) to a 50 ml sample and mix for 1 min. 7.7 Calculation: mg chloride/liter = (A - B)N x 5,450 ml of sample where: A = ml titrant for sample; B = ml titrant for blank; and N = normality of mercuric nitrate titrant. 8.0 QUALITY CONTROL 8.1 All quality control data should be maintained and available for easy reference or inspection. Refer to Chapter One for specific quality control guidelines. 8.2 Analyze a standard reference material to ensure that correct procedures are being followed and that all standard reagents have been prepared properly. 8. Employ a minimum of one blank per analytical batch or twenty samples, whichever is more frequent, to determine if contamination has occurred. 8.4 Run one matrix spike and matrix duplicate every analytical batch or twenty samples, whichever is more frequent. Matrix spikes and duplicates are brought through the whole sample preparation and analytical process. 9.0 METHOD PERFORMANCE CD-ROM 9252A - 4 Revision 1

9.1 Water samples--a total of 42 analysts in 18 laboratories analyzed synthetic water samples containing exact increments of chloride, with the results shown in Table 1. In a single laboratory, using surface water samples at an - average concentration of 4 mg Cl /L, the standard deviation was +1.0. A synthetic unknown sample containing 241 mg/l chloride, 108 mg/l Ca, 82 mg/l Mg,.1 mg/l K, 19.9 mg/l Na, 1.1 mg/l nitrate N, 0.25 mg/l nitrate N, 259 mg/l sulfate and 42.5 mg/l total alkalinity (contributed by NaHCO ) in reagent water was analyzed in 10 laboratories by the mercurimetric method, with a relative standard deviation of.% and a relative error of 2.9%. 9.2 Oil combustates--these data are based on 4 data points obtained by five laboratories who each analyzed four used crankcase oils and three fuel oil blends with crankcase oil in duplicate. The samples were combusted using Method 5050. A data point represents one duplicate analysis of a sample. One data point was judged to be an outlier and was not included in these results. 9.2.1 Precision and bias. 9.2.1.1 Precision. The precision of the method as determined by the statistical examination of interlaboratory test results is as follows: Repeatability - The difference between successive results obtained by the same operator with the same apparatus under constant operating conditions on identical test material would exceed, in the long run, in the normal and correct operation of the test method, the following values only in 1 case in 20 (see Table 2): Repeatability ' 7.61 x( *where x is the average of two results in µg/g. Reproducibility - The difference between two single and independent results obtained by different operators working in different laboratories on identical test material would exceed, in the long run, the following values only in 1 case in 20: Reproducibility ' 20.02 x( *where x is the average value of two results in µg/g. 9.2.1.2 Bias. The bias of this method varies with concentration, as shown in Table : Bias = Amount found - Amount expected CD-ROM 9252A - 5 Revision 1

10.0 REFERENCES 1. Annual Book of ASTM Standards, Part 1, "Water," Standard D512-67, Method A, p. 270 (1976). 2. Standard Methods for the Examination of Water and Wastewater, 15th ed., (1980).. U.S. Environmental Protection Agency, Methods for Chemical Analysis of Water and Wastes, EPA 600/4-79-020 (198), Method 25.. CD-ROM 9252A - 6 Revision 1

TABLE 1. ANALYSES OF SYNTHETIC WATER SAMPLES FOR CHLORIDE BY MERCURIC NITRATE METHOD Increment as Precision as Accuracy as Chloride Standard Deviation Bias Bias (mg/l) (mg/l) (%) (mg/l) 17 1.54 +2.16 +0.4 18 1.2 +.50 +0.6 91 2.92 +0.11 +0.1 97.16-0.51-0.5 82 11.70-0.61-2. 98 11.80-1.19-4.7 TABLE 2. REPEATABILITY AND REPRODUCIBILITY FOR CHLORINE IN USED OILS BY BOMB OXIDATION AND MERCURIC NITRATE TITRATION Average value, Repeatability, Reproducibility, µg/g µg/g µg/g 500 170 448 1,000 241 6 1,500 295 775 2,000 40 895 2,500 81 1,001,000 417 1,097 CD-ROM 9252A - 7 Revision 1

TABLE. RECOVERY AND BIAS DATA FOR CHLORINE IN USED OILS BY BOMB OXIDATION AND MERCURIC NITRATE TITRATION Amount Amount expected, found, Bias, Percent µg/g µg/g µg/g bias 20 460 140 +44 480 578 9 +20 920 968 48 + 5 1,498 1,664 166 +11 1,527 1,515-12 - 1,029 2,809-220 - 7,045 2,710-25 -11 CD-ROM 9252A - 8 Revision 1

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE) CD-ROM 9252A - 9 Revision 1