Operating instructions Vortex flow meter. SVxxx / / 2015

Similar documents
Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Operating instructions Magnetic-inductive flow meter. SM6x01 SM7x01 SM8x / / 2015

Operating instructions Magnetic-inductive flow meter SM4x00 SM6x00 SM7x00 SM8x00 SM6x01 SM7x01 SM8x01

Operating instructions Magnetic-inductive flow meter SM2001 SM / / 2014

Operating instructions Compressed air meter SD / / 2013

Operating instructions Compressed air meter SD / / 2013

Operating instructions Magnetic-inductive flow sensor SM / / 2010

Operating instructions Pressure sensor PN / / 2007

Operating instructions Volumetric flow sensor SQ / / 2012

Operating instructions Flow rate meter for gases SD / / 2010

Operating instructions Compressed air meter SD / / 2012

Operating instructions Infrared temperature sensor TW20xx TW21xx

Operating Instructions for Digital Manometer. Model: MAN-SD

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.

Sensors for pressure control OsiSense XMLR

Installation guide 862 MIT / MIR

Lamp and Control Panel (Lamp Panel)

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

OPERATING MANUAL. EIB-Kombisensor AS 315 N

Solenoid valves Type EVUL

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

VD1 CLC. Small Valves DIN-range with a higher k v -value

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

Kingspan Smart-Lite Kite Luminaire

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

Field Pro Operation and Installation Manual

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

ABB i-bus KNX Analogue Input AE/A 2.1

PHOENIX CONTACT - 04/2016. Features

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Cooling Water Flow Regulator

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

WeatherHub2 Quick Start Guide

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

16 Input AC Block I/O Module

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

Power Resistor for Mounting onto a Heatsink Thick Film Technology

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

E8EB-N0C2B E8EB-N0B2B

Drive electronics pq12

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Power Resistor for Mounting onto a Heatsink Thick Film Technology

Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil

SPECIFICATION SHEET : FHS2-UNV-36L

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

473 Dew Point Hygrometer

32 Input AC Block I/O Module

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

Power Resistor for Mounting onto a Heatsink Thick Film Technology

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

WS-7211U Wireless 433 MHz Weather Station. Instruction Manual

Power Resistor for Mounting onto a Heatsink Thick Film Technology

VK2 volume flow controller Overview

Power Resistor for Mounting onto a Heatsink Thick Film Technology

POINTS OF CAUTION BEFORE USE...

REPAIR PARTS. DX17VS Outdoor Inverter. This manual is to be used by qualified technicians only.

Power Resistor Thick Film Technology

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

Electromagnetic Flowmeter

CAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE.

Eppendorf Temperature Verification System. Operating manual /0909

Cooler-Bypass Thermostat Valve, Size 10

REPAIR PARTS. GMV9* Variable Speed Furnace

N) manual. Biomaster Operating manual

Power Resistor for Mounting onto a Heatsink Thick Film Technology

SPECIFICATION SHEET : FHS2-UNV-36L

FLOW SENSOR FOR LIQUID MEDIA Serie 210

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D

VOLUMEC. Valve Position Indicator 5

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

PR CYCLONE SECONDARY SHUTOFF

3B SCIENTIFIC PHYSICS

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

REPAIR PARTS. GMS95 Single Stage Upflow Furnace GMS950453BXAB GMS950703BXAB GMS950704CXAB GMS950904CXAB GMS951155DXAB.

LED light engine / OLED LED compact. Module DLE G4 ADV Modules DLE

ISSP User Guide CY3207ISSP. Revision C

Tunable White LED compact

nufacturing Company, L.P San Felipe, Suite 500

POWER PUSHER Snowplow

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

Modular Style Air Combination. Assembled by simply tightening the screws

ED 701 General Industry Pressure Transmitter

Circular Motion and Centripetal Force

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

473-SHX Dew Point Mirror

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

PRODUCT CATALOGUE PREssURE switch

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen

Direct-operated 2/2-way solenoid valves Type EV210B

Transcription:

Operating instructions Vortex flow meter SVxxx0 80229859 / 00 06 / 2015

Contents 1 Safety instructions...3 2 Functions and features...3 3 Function...4 4 Installation...4 5 Electrical connection...6 6 Operating and display elements...7 7 Menu...8 7.1 Main menu...8 7.1.1 Explanation main menu...9 7.2 Extended functions basic settings...10 7.2.1 Explanation basic settings (CFG)... 11 7.3 Extended functions min / max memory display...12 7.3.1 Explanation min/max memory (MEM)...13 7.3.2 Explanation display function (DIS)...13 8 Parameter setting...13 8.1 Parameter setting in general...14 9 Factory setting...14 Technical data, approvals, accessories and further information at www.ifm.com. 2

1 Safety instructions Please read this document prior to set-up of the unit. Ensure that the product is suitable for your application without any restrictions. If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property can occur. Improper or non-intended use may lead to malfunctions of the unit or to unwanted effects in your application. That is why installation, electrical connection, set-up, operation and maintenance of the unit must only be carried out by qualified personnel authorised by the machine operator. In order to guarantee the correct condition of the device for the operating time it is necessary to use the device only for media to which the wetted materials are sufficiently resistant ( Technical data). The responsibility whether the measurement devices are suitable for the respective application lies with the operator. The manufacturer assumes no liability for consequences of misuse by the operator. Improper installation and use of the units result in a loss of the warranty claims. CAUTION For medium temperatures above 50 C (122 F) some parts of the housing can heat up to over 65 C (149 F). Risk of burns. In this case do not touch the unit. Protect the housing against contact with flammable substances and unintentional contact. Do not press the pushbuttons manually; instead use another object (e.g. ballpoint pen). 2 Functions and features The unit monitors water-based fluids (water, deionised water, cooling water). It detects the two process categories volumetric flow and medium temperature. Pressure Equipment Directive (PED): The units comply with the Pressure Equipment Directive and are designed and manufactured for group 2 fluids in accordance with the sound engineering practice. Use of group 1 fluids on request. 3

3 Function The unit detects the volumetric flow quantity based on the Vortex measuring principle. It features an IO-Link interface. The unit displays the current flow and temperature. It generates 2 output signals according to the parameter setting: OUT1/IO-Link: 2 selection options --switching signal for volumetric flow quantity limit value --or frequency signal for volumetric flow quantity OUT2: 4 selection options --switching signal for volumetric flow quantity limit value --or switching signal for temperature limit value --or frequency signal for volumetric flow quantity --or frequency signal for temperature 4 Installation Flow in the direction of the arrow. Observe the installation direction. Make sure that pipe and sensor have the same internal diameter. Avoid deposits, accumulated gas and air in the pipe system. Install the unit so that the measuring pipe is always completely filled with medium. Install in front of or in a rising pipe. Recommended tightening torque: 30 Nm Avoid disturbances on the inlet and outlet side. To do so, provide for the following inlet and outlet pipe lengths: 1 2 F DN = nominal width of the pipe R = radius 4

Disturbance Inlet pipe length (1) Outlet pipe length (2) Non-ideal bend 5 x DN 1 x DN Ideal bend 0.5 x DN R1.8 x DN Multiple bends (2 x 90 ) 15 x DN Reduction of internal pipe diameter 15 x DN 15 x DN Valve or pump 25 x DN Mount the unit in a way that no mechanical forces are exerted on the pipe. To do so, use angle brackets if required. -- For direct installation, fix the unit on the surface using 4 self-tapping screws M4 DIN 7500. Maximum insertion depth in the housing: 5.5 mm. -- For installation using the fixing element: ifm mounting accessories at www.ifm.com. Avoid the following installation positions: -- Directly in front of a falling pipe. -- In a falling pipe. -- At the highest point of the pipe system. -- Directly in front of the spout of the pipe. -- On the suction side of a pump. 5

5 Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Voltage supply according to EN 50178, SELV, PELV. Disconnect power. Connect the unit as follows: 2 1 3 4 BK: black BN: brown BU: blue WH: white 1 2 4 3 BN WH BK BU L+ OUT2 OUT1 L Colours to DIN EN 60947-5-2 Pin 1 L+ Pin 3 L- Pin 4 (OUT1) Pin 2 (OUT2) Switching signal: limit values for volumetric flow Frequency signal for volumetric flow quantity IO-Link Switching signal: limit values for volumetric flow Switching signal: limit values for temperature Frequency signal for volumetric flow quantity Frequency signal for temperature 6

6 Operating and display elements 1 2 3 5 4 1 and 2: switching status LEDs LED 1 = switching status OUT1 (lights when output 1 is switched) LED 2 = switching status OUT2 (lights when output 2 is switched) 3: TFT display Display of current process values (volumetric flow quantity, temperature) Display of the parameters and parameter values 4: Buttons [ ] and [ ] Select parameters Change parameter values (hold button pressed) Change of the process value display in the normal operating mode (Run mode) Locking / unlocking (press buttons simultaneously > 10 seconds) 5: Button [ ] = Enter Change from RUN mode to the main menu Change to setting mode Acknowledgement of the set parameter value 7

7 Menu 7.1 Main menu Process value display (RUN) SP1 rp1 FH1 FL1 FEP1 FrP1 1 SP2 FH2 FSP2 rp2 FL2 FEP2 2 FrP2 EF CFG, MEM, DIS 1: Output functions ou1 ( 7.2.1) 2: Output functions ou2 ( 7.2.1) The parameters are only displayed when selected at ou1 / ou2. 8

7.1.1 Explanation main menu Switching output with hysteresis function SP1 Set point 1 = upper limit value at which OUT1 switches. rp1 Reset point 1 = lower limit value at which OUT1 switches off. SP2 Set point 2 = upper limit value at which OUT2 switches. rp2 Reset point 2 = lower limit value at which OUT2 switches off. Switching output with window function FH1 Set point 1 = upper limit value at which OUT1 switches. FL1 Reset point 1 = lower limit value at which OUT1 switches. FH2 Set point 2 = upper limit value at which OUT2 switches. FL2 Reset point 2 = lower limit value at which OUT2 switches. Frequency output FEP1 Process value end point on OUT1. FrP1 Frequency at process value end point (FEP1) on OUT1. FSP2 Process value start point on OUT2 (only if SEL2 = TEMP). FEP2 Process value end point on OUT2. FrP2 Frequency at process value end point (FEP2) on OUT2. Extended functions EF Opening of the lower menu level. 9

7.2 Extended functions basic settings Main menu RUN res EF - - - - ou1 Hno Hnc Fno Fnc FRQ CFG Info CFG MEM DIS ou2 ds1 dr1 ds2 dr2 Hno Hnc Fno Fnc FRQ 0,0...60 s 0,0...60 s 0,0...60 s 0,0...60 s uni P-n l/min PnP m 3 /h npn dap 0,0...5,0 s FOU1 On OFF OU FOU2 On OFF OU SEL2 FLOW TEMP * For SVx6xx units: gpm / gph The parameters are only displayed when oux = Hno, Hnc, Fno, Fnc. 10

res Info CFG MEM DIS Restoring the factory settings Device information Submenu basic settings Submenu min/max memory Submenu display settings 7.2.1 Explanation basic settings (CFG) ou1 ou2 Hno Hnc Fno Fnc FRQ ds1 dr1 ds2 dr2 uni P-n dap FOU1 FOU2 SEL2 Output function OUT1 Flow: Hno, Hnc, Fno, Fnc, FRQ Output function OUT2 Flow: Hno, Hnc, Fno, Fnc, FRQ Temperature: Hno, Hnc, Fno, Fnc, FRQ Hysteresis function normally open Hysteresis function normally closed Window function normally open Window function normally closed Frequency output Switching delay on OUT1 in seconds Switch-off delay on OUT1 in seconds Switching delay on OUT2 in seconds Switch-off delay on OUT2 in seconds Standard unit of measurement for volumetric flow Output logic: pnp / npn Measured value damping in seconds (only for volumetric flow) Behaviour of output OUT1 in case of an error Behaviour of output OUT2 in case of an error Standard measured variable for evaluation by OUT2: Volumetric flow quantity or medium temperature Only in case of oux = Hno, Hnc, Fno, Fnc 11

7.3 Extended functions min / max memory display Main Menu Lo.F MEM 0,0 l/min res EF Hi.F 0,0 l/min Info Lo.T 0,0 C CFG Hi.T 0,0 C MEM DIS dis.l L1 L2 DIS dis.u d1 d2 d3 dis.r 0 90 180 270 dis.b 25 50 75 100 OFF col.f OFF red GrEn r1ou G1ou r-cf G-cF cfh.f cfl.f 10 l/min 5 l/min col.t OFF red GrEn r2ou G2ou r-cf G-cF cfh.t cfl.t 50 C 0 C * For SVx6xx units: gpm, F The parameters are only displayed when selected r-cf oder G-cF. 12

7.3.1 Explanation min/max memory (MEM) Lo.F Hi.F Lo.T Hi.T Minimum value of the flow measured in the process Maximum value of the flow measured in the process Minimum value of the temperature measured in the process Maximum value of the temperature measured in the process 7.3.2 Explanation display function (DIS) dis.l dis.u dis.r dis.b col.f col.t OFF red GrEn Standard layout of the display(l1: flow or L2: flow and temperature) Update rate of display Display rotation Display brightness Colour configuration volumetric flow Colour configuration temperature No colour change Process value always red, irrespective of the output function Process value always green, irrespective of the output function r1ou / r2ou Process value red in case of switched output OUT1 / OUT2 G1ou / G2ou cfh.f cfl.f cfh.t cfl.t r-cf G-cF Process value green in case of switched output OUT1 / OUT2 Display red if measured value between limit values cfl...cfh, irrespective of the output function Display green if measured value between limit values cfl...cfh, irrespective of the output function Upper limit value for colour change flow Lower limit value for colour change flow Upper limit value for colour change temperature Lower limit value for colour change temperature Only if r-cf or G-cF is selected. 8 Parameter setting Parameters can be set before installation and set-up of the unit or during operation. If you change parameters during operation, this will influence the function of the plant. Ensure that there will be no malfunctions in your plant. 13

The parameters can also be set via the IO-Link interface. 8.1 Parameter setting in general 1. Change from RUN mode to the main menu [ ] 2. Selection of the requested parameter [ ] or [ ] 3. Change to setting mode [ ] 4. Modification of the parameter value [ ] or [ ] > 1 s 5. Acknowledgement of the set parameter value [ ] 6. Return to the RUN mode > 30 seconds (timeout) or press [ ] + [ ] simultaneously until the RUN mode is reached. 9 Factory setting Parameter Factory setting User setting SP1 (FLOW) 20 % * rp1 (FLOW) 18.5 % * FH1 (FLOW) 20 % * FL1 (FLOW) 18.5 % * FEP1 (FLOW) 100 % * FrP1 (FLOW) 100 Hz SP2 (FLOW, TEMP) 40 % * rp2 (FLOW, TEMP) 38.5 % * FH2 (FLOW, TEMP) 40 % * FL2 (FLOW, TEMP) 38.5 % * FSP2 (TEMP) 0 % * FEP2 (FLOW, TEMP) 100 % * FrP2 (FLOW, TEMP) 100 Hz ou1 (FLOW) Hno ou2 (FLOW, TEMP) Hno 14

Parameter Factory setting User setting FOU1 (FLOW) OFF FOU2 (FLOW, TEMP) OFF SEL2 (FLOW, TEMP) FLOW col.f (FLOW) OFF col.t (TEMP) OFF ds1 0 s dr1 0 s ds2 0 s dr2 0 s uni l/min (SVx6xx: gpm) P-n PnP dap 0.6 s dis.l L2 dis.u d2 dis.r 0 dis.b 75 % cfh.f MEW cfl.f MAW cfh.t MEW cfl.t MAW MEW = final value of the measuring range MAW = initial value of the measuring range * The percentage values refer to the final value of the measuring range. More information at www.ifm.com 15