The EPOM shift of cylindrical ionization chambers - a status report Hui Khee Looe 1, Ndimofor Chofor 1, Dietrich Harder 2, Björn Poppe 1

Similar documents
Dosimetry: Electron Beams

The Gaussian line spread functions of single and array-type ionization chambers

Comparison between TG-51 and TRS-398: Electron Contamination Effect on Photon Beam Quality Specification.

CHARACTERISTICS OF DEGRADED ELECTRON BEAMS PRODUCED BY NOVAC7 IORT ACCELERATOR

Efficiencies of Some Spherical Ion Chambers in Continuous and Pulsed Radiation: A Numerical Evaluation

Study of the influence of phantom material and size on the calibration of ionization chambers in terms of absorbed dose to water

STANDARD WATER PHANTOM BACKSCATTER FACTORS FOR MEDIUM ENERGY X-RAYS

8/2/2012 UPDATING TG-51. When will it end? Part 1 - photon addendum. What are these updates? Photons: Electrons: More widespread revision required

Reference Dosimetry for Megavoltage Therapy Beams: Electrons

1 Introduction. A Monte Carlo study

Heuijin Lim, Manwoo Lee, Jungyu Yi, Sang Koo Kang, Me Young Kim, Dong Hyeok Jeong

Updating reference dosimetry a decade after TG-51

Volume 1 No. 4, October 2011 ISSN International Journal of Science and Technology IJST Journal. All rights reserved

ABSORBED DOSE BEAM QUALITY FACTORS FOR CYLINDRICAL ION CHAMBERS: EXPERIMENTAL DETERMINATION AT 6 AND 15 MV PHOTON BEAMS

7. a XV-2 high spatial resolution lm detector (Kodak). Important parameters of these detectors are given in Table1. The ionization chambers and the di

) for Varian TrueBeam high-dose-rate therapy beams

ESTIMATION OF 90 SCATTERING COEFFICIENT IN THE SHIELDING CALCULATION OF DIAGNOSTIC X-RAY EQUIPMENT

Comparison of Primary Doses Obtained in Three 6 MV Photon Beams Using a Small Attenuator

Radiation Dosimetry. Electron interactions with matter. Important processes in radiotherapy. Contents. Alun Beddoe

M [scale units/s] of the system

ABSORBED DOSE TO WATER MEASUREMENTS IN HIGH ENERGY ELECTRON BEAMS USING DIFFERENT PLANE PARALLEL CHAMBERS *

Transport under magnetic fields with the EGSnrc simulation toolkit

High-Energy Photon Beam Therapy Dosimetry with Ionisation Chambers

Progress in calculations of k Q for TG-51

COMPARISON OF ABSORBED DOSE TO AIR CALIBRATION FACTORS FOR A PARALLEL PLATE IONIZATION CHAMBER*

Monte Carlo commissioning of photon beams in medical LINACS using wide-field profiles in a water phantom

Implementation of the IAEA-AAPM Code of Practice for the dosimetry of small static fields used in external beam radiotherapy

Relation Between Kerma and Absorbed Dose in Photon Beams

Manipulation on charged particle beam for RT benefit.

TITLE: Air Kerma Primary Standard: Experimental and Simulation Studies on Cs-137

N. E. Ipe*, K. E. Rosser, C. J. Moretti, J. W. Manning and M. J. Palmer

Determination of contributions of scatter and distance error to the source strength of 192 Ir HDR brachytherapy source

General characteristics of radiation dosimeters

BEAMnrc: a code to simulate radiotherapy external beam sources

Chapter V: Cavity theories

Monte Carlo Simulation concerning Particle Therapy

Chapter 9: Calibration of Photon and Electron Beams

Small Field Dosimetric Measurements with TLD-100, Alanine, and Ionization Chambers

Radiation Physics PHYS /251. Prof. Gocha Khelashvili

An introduction to IAEA TRS-483

Chapiter VII: Ionization chamber

A Measuring System with Recombination Chamber for Photoneutron Dosimetry at Medical Linear Accelerators

FOREWORD In 1987 the IAEA published a Code of Practice entitled Absorbed Dose Determination in Photon and Electron Beams: An International Code of

Clinical Implementation of the IPEM 2003 Code of Practice for Electron Dosimetry

Evaluation of different methods for determining the magnitude of initial recombination in ionization chambers

factors for NE2561 ionization chambers in 3 cm x 3 cm beams of 6 MV and 10 MV photons

Evaluation of backscatter dose from internal lead shielding in clinical electron beams using EGSnrc Monte Carlo simulations

Determination of Ambient Dose Equivalent at INFLPR 7 MeV Linear Accelerator

Determination of absorbed dose to water for 60Co by the scaling theorem. M. Boutillon and A.-M. Perroche (1)

Ionizing Radiation Dosimetry and Medical Physics

Prompt gamma measurements for the verification of dose deposition in proton therapy. Contents. Two Proton Beam Facilities for Therapy and Research

Comparison of the air kerma standards for 137 Cs and 60 Co gamma-ray beams between the IAEA and the NIST. Ronaldo Minniti 1 and Ladislav Czap 2

Design, construction and characterization of a portable irradiator to calibrate installed ambient dose equivalent monitors

Introduction. X-Ray Production and Quality. Fluorescence Yield. Fluorescence X-Rays. Initiating event. Initiating event 3/18/2011

A Study on Effective Source-Skin Distance using Phantom in Electron Beam Therapy

Magnetic removal of electron contamination in radiotherapy x-ray beams

Measurements and comparisons for data of small beams of linear accelerators

Ranges of Electrons for Human Body Substances

A Monte Carlo Study of the Relationship between the Time. Structures of Prompt Gammas and in vivo Radiation Dose in.

Larry A. DeWerd, PhD, FAAPM UW ADCL & Dept. Medical Physics University of Wisconsin

Principles of applied dosimetry - illustrated by ionometry. Lesson FYSKJM4710 Eirik Malinen

Simulation Modeling in Dosimetry

NACP-02 perturbation correction factors for the NPL primary standard of absorbed dose to water in high energy electron beams

DOI /

A Correction Factor for Effects of Scattered X-rays at Calibration of Ionization Chambers in Low Energy X-ray Standard Fields

Bureau International des Poids et Mesures

Geant4 and Fano cavity : where are we?

Spencer-Attix Cavity Theory

ERRATA LIST AND UPDATES TO IAEA TRS-398 (2000) 1

Air Kerma Primary Standard: Experimental and. Simulation Studies on Cs-137. J. Cardoso, L. Santos, C. Oliveira

Estimate of Photonuclear Reaction in a Medical Linear Accelerator Using a Water-Equivalent Phantom

Use of a radioactive check device for redundancy check of ionization chambers

A comparison of methods for monitoring photon beam energy constancy

Composite field dosimetry

Monte Carlo simulation with Geant4 for verification of rotational total skin electron therapy (TSET)

Study of the uncertainty in the determination of the absorbed dose to water during external beam radiotherapy calibration

8/4/2016. Determination of small field output factors, advantages and limitations of Monte Carlo simulations

NPL s progress towards absorbed dose standards for proton beams

Investigation of the standard temperature- pressure correction factor at low x-ray energies

Dosimetric Properties of the Field Sizes of 12MV Photon Beams: A Monte Carlo Study

Comparative Analysis of Nuclear Cross Sections in Monte Carlo Methods for Medical Physics Applications

Update on Calibration Studies of the Canadian High-Energy Neutron Spectrometry System (CHENSS)

PRIMARY STANDARDS of AIR KERMA for 60 CO and X-RAYS & ABSORBED DOSE in PHOTON and ELECTRON BEAMS. Malcolm McEwen

Ionization Chamber. Pocket dosimeter

A Thesis. entitled. Micro Ionization Chamber. Vidheesha Arora. Master of Science Degree in. Biomedical Sciences: Medical Physics

ASSESMENT OF UNCERTAINTIES IN A DAILY-CHECK BEAM ANALYZER. J. Melgar, C. Martín, C. Montes, F. Sáez, E. De Sena, P. Gómez

Evaluation of Correction Factors Applied in Photon Calibration of NIS TE Neutron Ionization Chambers

Outline. Indrin J. Chetty, AAPM 2006 Monte Carlo CE course. Indrin J. Chetty Henry Ford Hospital. David W. O. Rogers Carleton University

Monte Carlo Analyses of X-Ray Absorption, Noise, and Detective Quantum Efficiency Considering Therapeutic X-Ray Spectrum in Portal Imaging Detector

P 81 Investigation of the active volume dimensions of solid-state detectors using the PTB 10 MeV proton microbeam

Referensdosimetri. Crister Ceberg Medical Radiation Physics Lund University Sweden

For the next several lectures, we will be looking at specific photon interactions with matter. In today s lecture, we begin with the photoelectric

Monitor backscatter factors for the Varian 21EX and TrueBeam linear accelerators: measurements and Monte Carlo modelling.

KCDB-Identifiers: EURAMET.RI(I)-K1.2 / EURAMET.RI(I)-K4.2 / EURAMET.RI(I)-K5.1. Pilot laboratory: BEV (AT) Andreas Steurer 1), Wilhelm Tiefenboeck

Neutron Dose near Spent Nuclear Fuel and HAW after the 2007 ICRP Recommendations

Electron beam water calorimetry measurements to obtain beam quality conversion factors

BRACHYTHERAPY SOURCE USING THE EGSNRC MONTE CARLO CODE

Accelerators and radiation spectra

Quality-Assurance Check of Collimator and Phantom- Scatter Factors

Non-radioactive radiation sources. Lesson FYSKJM4710 Eirik Malinen

Transcription:

The EPOM shift of cylindrical ionization chambers - a status report Hui Khee Looe 1, Ndimofor Chofor 1, Dietrich Harder 2, Björn Poppe 1 1 Medical Radiation Physics Group, University of Oldenburg and Pius Hospital Oldenburg, Germany 2 Prof. em., Medical Physics and Biophysics, University of Göttingen, Germany Introduction The shift of the effective point of measurement (EPOM) from the reference point (the symmetry axis) of a cylindrical ionization chamber has been experimentally determined for high-energy X-rays by Johansson et al 1978, Huang et al 2010 and Looe et al 2011. For radiation, experimental EPOM shift determinations have been carried out by Johansson 1978, Swanpalmer and Johansson 2011 and by Legrand et al 2012. A preliminary review of these results will be given here in order to prepare the consideration of this subject in standards and codes of practice, and to clarify the need for additional measurements. The new issues to be dealt with are (1) that the quotient of - z (the upstream EPOM shift) and r (the inner chamber radius), - z/r, is not constant, but depends on r, and (b) that in high-energy X-ray fields the EPOM shift - z is constant over all depths from the buildup region down to and beyond the "reference depth" (10 cm), whereas in a -ray beam the value of - z at the reference depth (5 cm) significantly differs from that in the region of the depth-dose maximum. This has a bearing upon the calibration of ionization chambers in Co-60 gamma-ray fields. Methods and Materials This paper gives a review of published results, so that the experimental methods can be assumed as known to the reader. In our comparison of EPOM shifts between various authors we apply the convention that the EPOM shifts are derived from plots of relative (maximum-normalized) depth dose curves of the same radiation field measured with ionization chambers of different inner radius. In a first step the relative depth dose curves are plotted with z = depth coordinate of the reference point of the chamber. The assumption of equal amplitudes of the depth-dose maxima corresponds to the assumption that the correct calibration of all compared chambers would yield equal absolute maximum values. In a second step the relative depth dose curves are shifted to fit a reference depth curve measured with a whose EPOM is known to lie 1.5 mm below its proximal surface. This EPOM shift of the was experimentally determined for high-energy X-rays by Looe et al 2007, Bruggmoser et al 2007, and Looe et al 2011, but still needs experimental confirmation for radiation. Results A survey of the presently available experimental values of - z for high-energy X-rays and for Co- 60 gamma radiation is given in Tables 1 to 3. The first two tables show that the r dependence of the quotient - z/r, predicted in Monte Carlo calculations by Tessier 2010a, 2010b, has been experimentally observed for high-energy X-rays by Looe et al 2011, for radiation by Swanpalmer and Johansson 2011 and Legrand et al 2012. Whereas all authors determined - z values holding for the build-up branch and the maximum region of the depth dose curve, Legrand et al 2012 also made separate determinations of the - z values for the depth 5 cm in a -ray beam (Table 3). For the larger chamber radii, these - z values were significantly smaller than their values for the build-up branch and the region of the depth-dose maximum. Legrand et al 2012 hereby confirmed the existence of an effect already showing up in the paper by Johansson et al 1978 for radiation, whereas Johansson et al have not observed it for high-energy X-rays. We have again checked this issue by intercomparing the depth dose curves of 6 and 15 MV photon beams of a Siemens Artiste linac, measured in water with a, with a semiflex chamber of inner radius 2.75 mm (PTW 31013) and with a rigid stem chamber of 3.95 mm inner radius (PTW 23331): we again observed that for high-energy X-rays the EPOM shift remains practically the same whatever the depth in water.

Table 1: Experimentally observed EPOM shift values for cylindrical ionization chambers; high-energy X-rays Authors Examined, Johansson cylindrical chamber et al 1978 1) 3.5 mm (J-70) Huang et al 2010 2.75 mm (PTW 31002) 2.75 mm (PTW 31003) 3.05 mm (PTW 30006) Looe et al 2011 1.0 mm (PTW 31006) 2.5 mm (PTW 23332) 2.75 mm (PTW 31013) 3.95 mm (PTW 23331) 1) Measurements in a PMMA phantom Photon beam quality 5 to 42 MV 6 and 15 MV 6 and 15 MV EPOM shift - z in mm 2.3 + 0.1 0.65 + 0.03 1.5 + 0.08 1.5 + 0.08 1.7 + 0.09 0.3 + 0.05 0.9 + 0.1 1.3 + 0.1 2.3 + 0.2 0.30 + 0.05 0.36 + 0.04 0.47 + 0.04 0.58 + 0.05 Table 2: Experimentally observed EPOM shift values for cylindrical ionization chambers; radiation; values for the buildup branch and the dose maximum region Authors Johansson et al 1978 1) Swanpalmer and Johansson 1), 2) 2011 Legrand et al 2012 Examined, cylindrical chamber 3.5 mm (J-70) 1.5 mm (J-30) 2 mm (CC04) 3 mm (CC13) 3.5 mm (J-70) 1.0 mm (PTW 30013.1.911) 2.0 mm (PTW 30013.1.921) 2.75 mm (PTW 31010) 3.05 mm (PTW 30013) 4.0 mm (PTW 30013.1.941) 5.0 mm (PTW 30013.1.951) Photon beam quality EPOM shift - z in mm rays 2.3 + 0.1 0.65 + 0.03 rays 0.62 + 0.1 1.55 + 0.1 2.53 + 0.1 2.73 + 0.1 rays 0.2 + 0.3 1.0 + 0.2 1.6 + 0.3 2.0 + 0.4 2.4 + 0.3 3.6 + 0.2 4.6 + 0.4 0.41 + 0.07 0.78 + 0.05 0.84 + 0.03 0.78 + 0.03 0.2 + 0.3 0.5 + 0.1 0.72 + 0.04 0.8 + 0.1 6.0 mm (PTW 30013.1.961) 1) Measurements in a PMMA phantom 2) The values of - z were obtained by assuming the dose maximum to lie at 4 mm depth in PMMA Table 3: Experimentally observed EPOM shift values for cylindrical ionization chambers; radiation; values for the "reference depth" 5 cm in water Authors Legrand et al 2012 Examined, 1.0 mm (PTW 30013.1.911) 2.0 mm (PTW 30013.1.921) 2.75 mm (PTW 31010) 3.05 mm (PTW 30013) 4.0 mm (PTW 30013.1.941) 5.0 mm (PTW 30013.1.951) 6.0 mm (PTW 30013.1.961) Photon beam EPOM shift quality - z in mm rays 0.9 + 0.3 1.4 + 0.2 1.5 + 0.2 2.0 + 0.4 2.2 + 0.3 3.0 + 0.2 3.5 + 0.4 0.9 + 0.3 0.60 + 0.04 0.6 + 0.07

Fig. 1 Measured values of the EPOM shift, - z, as a function of the inner radius r of the examined ionization chamber (Tables 1 and 2). Data for high-energy X-rays (Johansson, Huang, Looe) are valid for the entire depth dose curves; data for radiation (Johansson, Swanpalmer, Legrand) are valid for the buildup and maximum regions of the depth-dose curves. Interpol. line see eq. (1). Fig. 1 shows an approximately uniform dependence of the EPOM shift of all examined chambers on their inner radius - a linear increase above a threshold value of the radius at about 0.9 mm. The threshold can be explained by the role of the secondary electrons emitted by the central electrode: with increasing relative contribution of these electrons to the total chamber signal the EPOM will tend to approach the symmetry line of the chamber. This interpretation is underpinned by Monte Carlo results obtained with chambers equipped with thick central electrodes (Tessier 2010 a,b). The straight interpolation line drawn in Fig. 1 corresponds to the equation - z = 0.87 (r - 0.9) with z and r in mm (1) and may be used for all inner radii of cylindrical ionization chambers from 1 to 6 mm with an uncertainty of - z by not more than 0.5 mm for high-energy X-rays as well as rays. This empirical rule replaces the previous rule - z = 0.6 r (IAEA TRS 398) or - z = 0.5 r (DIN 6800-2). It is valid for the EPOM shift of the entire depth dose curve (high energy X-rays) and of the buildup and maximum region in the case of rays. For the special case of the depth region around 5 cm in a -ray beam, Legrand et al 2012 approximated their data (Table 3) by a linear relationship which can be rewritten as - z = 0.53 (r + 0.45) with z and r in mm (2) This relationship is close to the hitherto used relationship - z = 0.5 r; but anyway it would be appropriate to accordingly change the correction factor k r (DIN 6800-2). This factor is regularly applied to compensate for the displacement effect when cylindrical ionization chambers, with their axes positioned at a depth of measurement of 5 cm in water, are calibrated in a -ray field. The corrected k r value would then amount to k r = 1 + 0.006 0.53 (r + 0.45) (with r in mm) (3) For the r between 2 and 3 mm, this value exceeds the previous k r value by 0.2 %.

Discussion For high-energy X-rays, experiments have confirmed that the EPOM shift is constant throughout all depths, from the buildup region up to and beyond the region of the reference depth (10 cm). This holds with high precision at 6 MV and still in a very good approximation at 15 MV. The associated value of the EPOM shift is represented by eq. (1). For radiation, the EPOM shift in the buildup branch and in the maximum region of the depth dose curve also corresponds to eq. (1), whereas in the region of the reference depth (5 cm) the EPOM shift corresponds to eq. (2). After a qualitative indication of this effect in Johanssons paper 1978, it was quantified by Legrand et al 2012 and is also described by Legrand et al in this conference. In order to understand this phenomenon it is useful to remember that the displacement effect, underlying the EPOM shift of a cylindrical ionization chamber, is due to the preferred entry of secondary electrons into the upstream surface of the chamber, a geometrical effect which in turn is caused by the preferred forward flight direction of the secondary electrons in the surrounding medium. This preferred orientation of the electron tracks is well-known from bubble chamber pictures and is known to cause the buildup effect. Therefore the chamber signal corresponds to a mean value of the secondary electron fluence weighted by their entry points on the surface of the chamber, which preferently lie on the upstream side. This picture will however change with changing directional distribution of the secondary electrons in the surrounding medium. This distribution is coined by their initial directions due to the Compton effect in the relativistic energy region and by their further transport under the influence of their ranges and multiple scattering. While the mean initial energy of the Compton electrons produced by 6 or 15 MV X-rays is near or beyond 1 MeV, it amounts to less than 0.5 MeV in case of the Co-60 gamma radiation. Furthermore there is a change of the spectrum and directional distribution of the photons with increasing depth, to be characterized by their mean energies in the reference depths of 10 cm for the high-energy X-rays and 5 cm for the rays (see Fig. 2). These mean energies are 1.2 MeV and 2.9 MeV for the 6 and 15 MV X-rays, with an increasing tendency at the larger depths due to a dominating filter effect, whereas the mean energy is only 0.9 MeV for the Co- 60 gamma radiation, with a decreasing tendency at the larger depths due to the dominating effect of the buildup of Compton-scattered photons (Chofor et al 2012). We are in the process of more precisely modeling these spectral influences upon the directional distribution of the secondary electrons. Fig. 2 The depth dependence of the mean photon energy E m = E E (E) de / E (E) de with E (E) = spectral fluence, Monte-Carlo calculated for on-axis points in 15 MV, 6 MV and Co-60 photon beams of SSD 100 cm and surface field size 10 cm 10 cm, as a function of the depth in water (Chofor 2012).

In this paper, Monte Carlo calculations have been considered to give essential qualitative information such as on the r dependence of the quotient - z/r and on the role of the central electrode (Tessier et al 2010a,b), as well as on the depth dependence of the mean photon energy E m (Chofor 2012). The highest possible accuracy of the EPOM data, however, can presently be achieved experimentally, because the experimental data are subject to all possible influences and effects whereas the Monte Carlo calculations can only reflect the effects that have been implemented in their algorithms. Conclusions In conclusion, experiments have shown that the dependence of the EPOM shift of cylindrical ionization chambers upon the chamber radius follows equations (1) and (2) and differs from the previously assumed proportional relationship. The different EPOM-radius relationship for Co-60 gamma rays observed by Legrand et al 2012 near the reference depth of 5 cm has been qualitatively explained by the different directional distribution of the secondary electrons entering the chambers. We recommend to use eq. (1) to allow for the EPOM shift in the measurement of the depth-dose data of high-energy X-rays, but to use eq. (3) to determine factor k r in the context of chamber calibrations in -ray beams. The position of the EPOM of the at 1.5 mm below its proximal surface still needs experimental confirmation for radiation. Acknowledgement Cordial thanks to Carine Legrand and Günther Hartmann for helping with data and discussions. s Bruggmoser G, Saum R and Schmidt F 2007 Wo befindet sich der effektive Messort einer PTW 34001 Roos- Kammer? In: Dreiländertagung "Medizinphysik 2007", Bern, Eds. M. K. Fix, P. Manser, R. Mini. DIN 6800-2 (2008). Procedures of dosimetry with probe type for photon and electron radiation - Part 2: Ionization chamber dosimetry of high energy photon and electron radiation Beuth Verlag, Berlin Chofor N, Harder D and Poppe B 2012 Non-reference condition correction factor k NR of typical radiation applied for the dosimetry of high-energy photon fields in radiotherapy Z. Med. Phys. subm. Huang Y, Willomitzer C, Zakaria G A, Hartmann G H 2010 Experimental determination of the effective point of measurement of cylindrical ionization chambers for high-energy photon and electron beams Physica Medica 26 126-131 International Atomic Energy Agency 2000. Absorbed dose determination in external beam radiotherapy: An international code of practice for dosimetry based on standards of absorbed dose to water Vol. 398 of Technical Report Series IAEA, Vienna. Johansson K A, Mattsson L O, Lindborg L and Svensson H 1978 Absorbed-dose determination with ionization chambers in electron and photon beams having energies between 1 and 50 MeV IAEA Symposium Proceedings, Vienna, IAEA-SM-222/35 (1978), pp. 243 270 Legrand C, Hartmann G H and Karger C P 2012a Experimental determination of the effective point of measurement for cylindrical ionization chambers in 60 Co gamma radiation Phys. Med. Biol. accepted for publication Looe H K, Chofor N, Djouguela A, Harder D and Poppe B 2007 Accurate experimental determination of the effective point of measurement of radiation In: Dreiländertagung "Medizinphysik 2007", Bern, Eds. M. K. Fix, P. Manser, R. Mini. Looe H K, Harder D and Poppe B 2011 Experimental determination of the effective point of measurement for various used in photon and electron beam dosimetry Phys. Med. Biol. 56 4267-4290 Swanpalmer J and Johansson K-A 2011 Experimental investigation of the effect of air cavity size in cylindrical ionization chambers on the measurements in 60 Co radiotherapy beams Phys. Med. Biol. 56 7093-7107 Tessier F and Kawrakow I 2010a Effective point of measurement of thimble ion chambers in megavoltage photon beams Med. Phys. 37 96 107. Tessier F 2010b Accurate dose distributions: The implications of new effective point of measurement values for thimble ionization chambers IDOS, Vienna 2010 a, E2-CN-182, paper No. 147