Series 2 Air Server Automated canister and on-line air/gas analysis

Similar documents
Thermal Desorption Technical Support

TD-100. Automated thermal desorber. Universal TD system for up to 100 RFID-tagged or untagged tubes

CIA Advantage-xr. Cryogen-free automated canister and whole-air sampling system

Series 2. Continuous monitoring of trace chemical vapours

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

TDTS 16 Round-the-clock, on-line and cryogen-free monitoring of hydrocarbons from acetylene to trimethylbenzene in ambient air

Application Note. Application Note 081 Innovative Cryogen-Free Ambient Air Monitoring in Compliance with US EPA Method TO-15. Abstract.

Series 2 UNITY A universal TD platform for tagged and untagged tubes

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Maximizing Sample Throughput In Purge And Trap Analysis

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Headspace Technology for GC and GC/MS: Features, benefits & applications

INNOVATIVE PRODUCTS, SUPERIOR SUPPORT. Presenter: Anne Jurek, Senior Applications Chemist, EST Analytical

Application Note 032

Methanol Extraction of high level soil samples by USEPA Method 8260C

Target Compound Results Summary

EPA TO-17 Volatile Organic Compounds

SUMMARY REPORT OF AIR MONITORING FOR LEED CERTIFICATION PHASE 2 SWANSFIELD ELEMENTARY SCHOOL 5610 CEDAR LANE COLUMBIA, MD PREPARED FOR:

US EPA Method with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260

Validation of USEPA Method Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Validation of USEPA Method Using a Stratum PTC and the New AQUATek 100 Autosampler

Centri. A breakthrough in sample automation and concentration for GC MS

The following report includes the data for the above referenced project for sample(s) received on 5/15/2017 at Air Toxics Ltd.

Roger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1

Determination of Volatile Organic Compounds in Air

US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS

Analysis. Introduction: necessary. presented. Discussion: As part of be carried. consistent and reliable data. (MoRT) to.

Analysis of Low Level Volatile Organic Compounds in Air Anne Jurek

Analysis of Volatile Organic Compounds in Water and Soil by EPA Method 8260 with the Atomx Concentrator/Multimatrix Autosampler

Optimal VOC Method Parameters for the StratUm PTC Purge & Trap Concentrator

A Comparison of Volatile Organic Compound Response When Using Nitrogen as a Purge Gas

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Validation of Volatile Organic Compound by USEPA. Method 8260C. Application Note. Abstract. Introduction. Experimental-Instrument Conditions

AUTONOMOUS, REAL TIME DETECTION OF 58 VOCS IN THE PANAMA CANAL

Performance of a Next Generation Vial Autosampler for the Analysis of VOCs in Water Matrices

Exploring US EPA Method 524 Purge and Trap Variables: Water Vapor Reduction and Minimizing Cycle Time

U.S. EPA VOLATILE ORGANICS METHOD USING PURGE AND TRAP GC/MS

Thermal Desorption Technical Support

Helium conservation in volatile organic compound analysis using U.S. EPA Method 8260C

R.E.A.C.T. Roxbury Environmental Action CoaliTion P.O. Box 244 Ledgewood, N.J Website:

Real Time On-Site Odor and VOC Emission Measurements Using a znose

TO-17 Extending the Hydrocarbon Range above Naphthalene for Soil Vapor and Air Samples Using Automated

Validation of USEPA Method 8260C Using Teledyne Tekmar Atomx, and Perkin-Elmer Clarus 600 GC/MS

STANDARD OPERATING PROCEDURES

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Optimizing. Abstract: is standardd. procedures. altered to

CALA Directory of Laboratories

Electronic Supplementary Material Experimentally Validated Mathematical Model of Analyte Uptake by Permeation Passive Samplers

Vapor Intrusion Sampling Options: Performance Data for Canisters, Badges, and Sorbent Tubes for VOCs

System and JUREK ANNE. Introduction: in an in purge and. trap sampling. Discussion: As part of. consistent and reliable data. (MoRT) to.

Validation of Environmental Water Methods on One System: Considerations for Sample Volume, Purge Parameters and Quality Control Parameters

Analysis of Volatile Organic Compounds in Soil Samples by EPA Method 8260 with The Stratum PTC and SOLATek 72 Multi-Matrix Autosampler

C146-E209. Headspace Samplers. HS-20 Series

Copyright 2009 PerkinElmer LAS and CARO Analytical Services, Inc.

high performance OPTIC 3 and applications a total analytical solution

Analysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the 4100 Autosampler

Ed George and Anaïs Viven Varian, Inc.

Enhanced Preconcentrator for the Analysis of Vapor Phase Volatile Organic Compounds

AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY

Solid Phase Micro Extraction of Flavor Compounds in Beer

A Single Calibration for Waters and Soil Samples Performing EPA Method Anne Jurek Applications Chemist

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

NIST gas standards containing volatile organic compounds in support of ambient air pollution measurements

Analytical Trap Comparison for USEPA Method 8260C

TDTS. Keywords. Introduction. TD Operation; Calibration; Impedance; Discrimination

Meeting NJ Low Level TO-15 Air Testing Method Requirements

Rapid Determination of TO-15 Volatile Organic Compounds (VOCs) in Air

Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Optimizing of Volatile Organic Compound Determination by Static Headspace Sampling

A Single Calibration Method for Water AND Soil Samples Performing EPA Method 8260

Neue Möglichkeiten zur Überwachung der Umgebungsluft mit Thermodesorption und GC/MS

Optimal Conditions for USEPA Method 8260B Analysis using the EST Analytical Sampling system and the Shimadzu GCMS-QP2010s

Application Note 059 Direct Desorption of Car Trim Materials for VOC and SVOC Analysis in Accordance with VDA Method 278

SELECTED ION FLOW TUBE MASS SPECTROMETRY. Interscience Expert Center: VIP Meeting 15 Sept. 2009

Solid Phase Microextraction of Cyanogen Chloride and Other Volatile Organic Compounds in Drinking Water with Fast Analysis by GC-TOFMS

HiSorb sorptive extraction

OREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation ALS Environmental - Simi Valley

Enhanced odour profiling of strawberries using TD GC TOF MS

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

Combustible Gas Catalytic Bead (0-100 %LEL) Part No FM Performance Certified 1,4 FM Performance Certified 1

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

2017 EPA Method Update Rule and EPA Method 624.1

Application News AD Quantitative Determination of Volatile Organic Compounds in Drinking Water by EPA Method with Headspace Trap GC-MS

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Maximizing Production While Minimizing Costs

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE

Fusion UV/Persulfate TOC Analyzer

Optimization of 1,4-Dioxane and Ethanol Detection Using USEPA Method 8260 Application Note

Fast, Quantitative Analysis of Residual Solvents in Cannabis Concentrates

Optimizing Standard Preparation

RS DYNAMICS ECOPROBE 5. Portable IR/PID Gas Analyzer PID. PID and IR Analyzers

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

Low-Level Sulfur Compounds in Beer by Purge and Trap with a Pulsed Flame Photometric Detector (PFPD)

Transcription:

Series 2 Air Server Thermal Desorption Options Automated canister and on-line air/gas analysis

Series 2 Air Server A range of accessories for series 2 UNITY thermal desorbers offering automated canister analysis and on-line air/gas monitoring Thermal desorption technology Thermal desorption (TD) is a highly versatile, sensitive and labour-saving sample preparation technique for the measurement of volatile and semi-volatile organic compounds (VOC and SVOC) in air and materials. It is applicable to GC-compatible organics ranging in volatility from acetylene to n-c 40 and a few inorganic gases; including nitrous oxide, SF 6, CS 2 and H 2 S. Key applications include: Environmental and workplace air monitoring Civil defence and forensic analysis Materials and materials emissions testing Food, flavour and fragrance profiling Many material samples such as drugs, foods, textiles, polymers, paints etc. can be directly thermally desorbed by weighing them into empty TD sample tubes. Innovation and excellence in thermal desorption Since 1997, Markes International has re-engineered analytical thermal desorption for the 21st century. Harnessing unparalleled technical expertise, the company has developed a suite of universal TD systems and unique sampling accessories incorporating key proprietary innovations such as: SecureTD-Q and automated sample recollection using a single TD autosampler 1 RFID tube tagging (TubeTAG ) 2 Diffusion-locking for effective tube sealing and robust automation 3 Innovative low volume valving specifically designed for TD 4 Many of these innovations now set the standard for TD instrumentation worldwide. Alternatively, vapours in gas or air can be concentrated on- or off-line onto sorbent traps/tubes before TD- GC(MS) analysis. 1. Patent# GB 2395785 (Automated re-collection using a single TD autosampler), 2. Patent# US 6,446,515 B2, 3. Patent# GB 2337513 US 6,564656 B1 4. Patent# GB 2336649

Air Server 2 Main Features Adds automated canister and on-line air/gas stream analytical capability to any series 2 (ULTRA-)UNITY thermal desorption (TD) system. Cryogen-free operation and low consumption of gas supplies for lower running costs and higher uptime. Minimum 3 channels for sequencing between sample, zero and standard air/gas streams during unattended on-line monitoring. Up to 8 channel operation available for high throughput analysis of whole-air/gas samples canisters, bags, etc. Quantitative retention of ultra-volatiles such as acetylene from increased sample volumes (up to 1.5 L) combined with peerless high-resolution capillary chromatographic performance (even under splitless conditions) ensure optimum sensitivity. Parts per trillion (ppt) levels are readily detected. Method compliant tube desorption capability included with every system. Can be automated. Thermostatted flow path and internal standard addition options for compliance with standard canister methods. Negligible sample carryover plus versatile sampling flows & flexible splitting options allow analysis of both high and low concentration samples. Small footprint: Especially useful for installation in mobile labs. Versatile water management options for analysis of both dry and humid air/gas samples. Connects to any commercial GC/GCMS and offers enhanced selective purging for compatibility with real-time detectors such as process MS and sensor-arrays. Introducing the series 2 Air Server range Series 2 Air Server modules add to any series 2 (ULTRA-)UNITY system to allow a controlled flow of whole-air or gas to be introduced directly into the electrically-cooled focusing trap of the desorber. The combined systems operate cryogen-free (to minimise running costs/maintenance) and offer optimum analytical performance/sensitivity. With 3- and 8-channel options available, methodcompliant series 2 (ULTRA-)UNITY-Air Server systems are suitable for both automated analysis of canister/bag samples and round-the-clock unattended monitoring of on-line air/gas streams. Air Toxics in ambient air e.g. US EPA Method TO-(14)15 Industrial process control of gas purity and odour Atmospheric research e.g. global background pollution levels, pollution transport and kinetic studies, such as monitoring diurnal changes in urban air pollution or biogenic emission profiles Series 2 (ULTRA-)UNITY-Air Server systems connect to standard GC/GCMS technology and/or real-time process detectors. Key applications include: Continuous monitoring of ozone precursors (C 2 to C 10 hydrocarbons) in ambient air and/or vehicle emissions On- or off-line odour monitoring e.g. measuring reduced sulphur species such as H 2 S, mercaptans and sulphides in canisters, bags or on-line air streams at sub- to low-ppb levels

Overview of Air Server operation Series 2 Air Servers connect to any series 2 UNITY or Series 2 Air Server UNITY 2 GC(MS) ULTRA-UNITY TD system. They contain 3- or 8- inert sample/stream selection valves uniquely configured to eliminate dead volumes and prevent carryover. Each Sample selection valves Cold trap whole air/gas sample (pressurised or at (sub-)atmospheric pressure) is introduced directly into the electrically-cooled, sorbent-packed, focusing trap of the UNITY 2 thermal desorber for a user-specified Optional split sampling time. Conventional sorbent sampling tubes Sampling Desorption are not used in this process. flow flow The sampling flow is regulated by an electronic mass flow controller (MFC) and optional pump located downstream of the trap to eliminate risk of contamination. Focusing trap sorbent and trapping temperatures are selected for quantitative retention of the compounds of interest and for selective purging of potential interferences such as CO 2 and water. No liquid cryogen is required and only inert, non-emitting components come into contact with the sample. All sampling parameters are monitored by system software as an integral part of the analytical method. At the end of sample introduction, the flow path is purged with carrier gas to prevent carryover and eliminate oxygen from the focusing trap. The trap then heats rapidly in a reverse stream of carrier gas to inject/transfer retained compounds into the measurement system and trigger the analysis. This transfer/injection may be performed splitless for maximum sensitivity. (See UNITY 2 brochure for more details.) Schematic of Air Server 3 operation Once the focusing trap has desorbed, it cools and reequilibrates at the trapping temperature. Focusing of the next air/gas sample in the sequence may begin while analysis of the previous sample is ongoing to optimise throughput. Series 2 Air Server range The series 2 Air Server range includes products for 3- and 8-channel sequencing. The table below highlights the differences between the products: Note: Air Server 3 and 8 modules are integrated with UNITY 2 prior to shipment or during field installation to minimize bench space in confined locations such as mobile labs or remote monitoring stations. The CIA 8 is a separate module. Air Server 3 Air Server 8 Canister Interface Accessory (CIA 8) Number of channels 3 8 8 Thermostatted flow path Internal standard addition

Up to 8-channels for optimum throughput Intuitive user interface Series 2 (ULTRA-)UNITY-Air Server control is intuitive and integrated with the UNITY 2 TD software to provide one comprehensive and easy to understand user interface (UI). The UI offers a specific mode for on-line/canister operation (see figure opposite) and, once selected, users are prompted to enter the relevant sampling parameters such as sampling time, flow rate and purge times. Sequence building Automated sequences for on-line monitoring and/or automated canister/bag analysis are easily constructed via the sequence builder. Samples may be assigned individual desorption methods. Each sample is classified as sample, calibrant or blank and all sequences may be stored and recalled for future reference or repeat use. Graphical sequence viewer The sequence viewer presents a clear graphical display of current sequence status. Sequence reporting Information associated with each analysis, such as the time, date and any deviations, are all recorded in the sequence reporter. Any sample sequence failure triggers the GC(MS) system to start a blank run to keep the analyser in step with the autosampler. Control method screen (top) of user interface. Complete user interface screen (bottom)

Round-the-clock, cryogen-free monitoring On-line operation On-line monitoring systems typically comprise a series 2 UNITY with integrated 3- or 8-channel Air Server module. The combined system is programmed to repeatedly introduce air/gas from the sample stream(s) and to automatically sequence calibration gas and zero air/gas at user-defined frequencies, typically once every 24 hours. Sequences may be recycled indefinitely to minimise system programming. Continuous monitoring of ozone precursors (C 2 C 10 hydrocarbons) in urban air, as required by both European and US regulations 1,2, is a key application for series 2 UNITY-Air Server 3 (or 8) systems. 1. Council Directive 96/62/EC: On ambient air quality assessment and management, and the daughter directive - 2002/3/EC relating to ozone in ambient air 2. 1990 US Clean Air Act Ammendment Key advantages of Markes series 2 UNITY-Air Server systems for ozone precursor monitoring include: Unattended operation for extended periods: Cryogen-free operation and low consumption of gases simplify installation in mobile labs and offers extended periods of unattended operation in remote field monitoring stations. Markes cryogen-free series 2 UNITY-Air Server systems consume only 40 ml/min dry gas/air when configured without a Nafion dryer and less than 200 ml/min when a dryer is configured. This is between 3 and 10 times less than other cryogenfree ozone precursor monitoring systems and allows extended operation without cylinder replacement Sensitivity: Quantitative retention of ultravolatiles such as acetylene from up to 1.5 L air sample volumes combined with efficient splitless desorption at low (<2 ml/min) flows ensures best possible detection limits (typically 1-50 ppt levels) Compound Det limti (ppb) 450 ml sample Column %RSD (n=12) R t 450 ml sample % RSD (n=12) peak area 450 ml sample Ethane 0.026 Al PLOT 0.07 0.3 Butane 0.010 Al PLOT 0.01 0.4 Hexane 0.019 DB1 0.01 0.5 Octane 0.017 DB1 0.01 1.0 Data courtesy of Ecole des Mines de Douai, France Splitless desorption of 56-compound US EPA mix of ozone precursors using series 2 UNITY-Air Server 3 with dual column/dual FID GC with Dean s switch

Acetylene Peak Area Data courtesy of Ecole des Mines de Douai, France y = 0.2953x + 5.2249 R 2 = 0.9999 Timed start Series 2 UNITY-Air Server systems allow the start of a monitoring sequence to be programmed for a specific date and time (e.g. noon on Monday May 1st) and for the period between each sampling cycle to be fixed. The sampling cycle used for ozone precursor monitoring for example, is typically 1 hour. In this case air is usually sampled into the UNITY 2 focusing trap for 40 minutes of every hour starting on the hour. Sample Volume (ml) Cryogen-free trapping of ultra-volatile compounds including acetylene (ethyne) from up to 1.5 L of air Reliably excellent chromatographic performance: Great resolution, stable retention times and repeatable concentration data minimise measurement uncertainty and simplify data interpretation/validation Small footprint: The Series 2 UNITY with integrated 3- or 8-channel Air Server is only 22 cm (9-inches) wide On-line odour monitoring - Another key application for series 2 UNITY with integrated Air Server 3 option H 2 S CH 3 SH 20 ppb DMDS Compound Minimum Detection Limit (ppb) %RSD (n=10, 20ppb) DMS Hydrogen sulphide (H 2 S) 0.15 4.1 Methyl mercaptan (CH 3 SH) 0.15 1.8 Dimethyl sulphide (C 2 H 6 S) 0.15 0.8 H 2 S CH 3 SH DMS DMDS 10 ppb Dimethyl disulphide (C 2 H 6 S 2 ) Data courtesy of ITC, South Korea 0.10 0.8 Field-proven, robust on-line monitoring of H 2 S and other reduced sulphur compounds down to sub-ppb levels in ambient air

Automated off-line analysis of canister/bag samples Key issues associated with automated canister analysis include throughput, running costs, sensitivity, water management and method compliance. A typical Markes Air Server system configuration in this case would be the series 2 (ULTRA)-UNITY with an 8-channel Canister Interface Accessory (CIA 8). This system features a thermostatted sample flow path and internal standard (IS) addition to the focusing trap. It is fully compliant with relevant standard methods such as US EPA Method TO-15. Air toxics analyzers Key advantages of Markes series 2 (ULTRA-)UNITY-Air Server technology for air toxics monitoring and for canister air analysis generally include: Productivity: Markes systems offer 8-channels for automated operation over an extended period. Confirmatory repeat analysis of each canister may be included in the automation sequence Cost reduction. Cryogen-free operation minimises: Capital costs (no liquid nitrogen dewar required) CIA 8 Stream selection Samples Internal standard addition Optional split Internal standard UNITY Sampling flow GCMS Desorption flow Running costs (cryo-cooled systems require fresh supplies of liquid coolant as often as every 2 or 3 days) Manpower (changing/refilling of liquid coolant dewars takes time and effort) Downtime (replenishing liquid cryogen often interrupts an automated sequence) Analytical excellence: Super-efficient trap desorption and reliably excellent chromatographic performance, even under splitless conditions and without on-column focusing (see Series 2 UNITY brochure), optimise sensitivity and simplify identification of target air toxic analytes even in complex backgrounds. Schematic of series 2 UNITY - CIA 8 operation Versatile sample splitting options offer compatibility with vapour concentrations ranging from ppt to ppm Versatile water management: Markes systems offer selective purging of water, sophisticated sample splitting and the option of in-line dryers for effective water management under any air monitoring conditions. Cryogen-free operation saves thousands of dollars a month...

Canisters, bags and sorbent tubes TO-15 standard chromatogram (1 ppb in 1 L) (main) and real air sample (insert) 1 Dichlorodifluoromethane 2 1,2 Dichlorotetrafluoroethane 3 Methyl chloride 4 1,3 Butadiene 5 Methyl bromide 6 Trichlorotrifluoroethane (Freon 113) 7 Isopropyl alcohol 8 Carbon disulfide 9 Methylene chloride 10 Tert-butyl methyl ether 11 1,1-Dichloroethane 12 Ethyl acetate, methyl ethyl ketone 13 Tetrahydrofuran 14 Cyclohexane 15 Benzene 16 n-heptane 17 Trichloroethylene 18 1,2 Dichloropropane 19 Bromodichloromethane 20 Trans-1,3-dichloropropene 21 Methyl isobutyl ketone 22 Toluene 23 Cis-1,3-Dichloropropene 24 Tetrachloroethylene 25 Methyl n-butyl ketone 26 Dibromochloromethane 27 1,2 Dibromoethane 28 Chlorobenzene 29 Ethylbenzene 30 Xylene 31 Styrene 32 Tribromomethane 33 1,1,2,2-Tetrachloroethane 34 1,2,4-Trimethylbenzene 35 1,3,5-Trimethylbenzene 36 1,2-Dichlorobenzene 37 1,3-Dichlorobenzene 38 Chloromethylbenzene (alpha) 39 1,4 Dichlorobenzene 40 1,2,4 Trichlorobenzene 41 Hexachloro-1,3-butadiene 2-Methyl butane Isopropyl alcohol DCM Hexane Methyl cyclopentane 2,4-Dimethyl pentane Cyclohexane Benzene 1-Methyloxy-2-propanol 0.1 ppb level Toluene 30 31 34 35 36 38 39 37 40 41 29 33 6 16 21 22 24 25 28 1 2 4 7 8 9 10 11 12 13 14 15 17 18 19 20 23 26 27 32 3 5 Time (mins)

ppm...ppb...ppt Versatility The application range of series 2 Air Server technology Series 2 (ULTRA-)UNITY Air Server systems offer quantitative and cryogen-free retention, even of ultravolatile species such as freons and C 2 hydrocarbons, together with complete recovery across the air toxics boiling range. Labile, odorous analytes, such as H 2 S and mercaptans may also be measured at sub-ppb concentrations. Markes systems are compatible with the highest boiling compounds that can be recovered from canisters or ambient temperature air/gas streams. New improved stream selection valves and an inert flow path eliminate sample carryover even when monitoring over a wide concentration range (ppt to ppm). This allows ambient air samples to be calibrated with small volumes of relatively concentrated standard gas. It also allows automated sequencing of samples varying widely in concentration without fear of contamination. Compatibility with samples over a wide concentration range is further enhanced by sophisticated, electronically-controlled sample splitting during trap desorption (and during tube desorption, if applicable). On-line monitoring, canisters/bags and tube desorption Whether they are used for on-line monitoring or offline canister/bag analysis, all systems incorporating series 2 Air Server technology, offer complementary tube desorption. Every series 2 Air Server is connected to a Markes (ULTRA-)UNITY 2 system. The UNITY 2 TD platform offers method-compliant desorption of single tubes and the addition of a series 2 ULTRA allows automatic analysis of up to 100 sorbent tubes. Series 2 (ULTRA-) UNITY systems are described in detail in the associated brochures and their performance is not compromised in any way by the addition of an Air Server module. In summary, key advantages of series 2 (ULTRA-)UNITY systems for tube desorption include: Application versatility. Series 2 (ULTRA-)UNITY systems are compatible with every TD application on one analytical platform; ultra-volatiles (e.g. C 2 hydrocarbons), semi-volatiles (up to n-c 40 ) and reactive compounds. Samples for tube desorption either comprise sorbent tubes used to collect organic vapours or material samples (solid or liquid) weighed directly into empty TD sample tubes for direct desorption. Splitless, single or double split options allow analysis of samples ranging in concentration from ppt to percent without overloading the analytical system Toluene Subsequent blank run 30 ml of air from bubbles in the ice core collected in canisters. Analysis by TD-GC- MS in NCI mode. Unit ppt detection limits Contaminated air sample Negligible carryover with series 2 UNITY-Air Server Detection of trace level analytes aids atmospheric research

Real time monitoring - real time detection Method compliance. Markes tube desorption technology complies with all key standard methods; US EPA Method TO-17 (ambient and indoor air), EN ISO 16017 (workplace, ambient and indoor air), ISO 16000 (materials emission testing), NIOSH 2549 (workplace indoor air), etc. Important features for method compliance include effective tube sealing during automation, stringent (ambient-temperature/no-flow) leak testing, cryogen-free cooling and the option of IS addition Repeat analysis. Markes proprietary SecureTD-Q facility is supplied as standard with every series 2 (ULTRA-)UNITY system. It offers quantitative re-collection of any split flow (during tube or trap desorption) facilitating repeat analysis and simplifying method/data validation. SecureTD-Q overcomes the one-shot limitation of other thermal desorbers High throughput. 100-tube capacity and overlap mode (the ability to begin desorption of a subsequent sample while analysis of a previous sample is ongoing) optimise productivity/revenue generation Measurement system The majority of TD systems incorporating Markes series 2 Air Server technology are connected to standard or portable GC(MS) systems. However, it is also possible to configure the TD system with real-time detector technology, either in parallel with the GC(MS) or as an alternative to GC(MS). Most environmental monitoring applications require the resolution of capillary GC(MS) because of the diversity and variability of organic vapour profiles which can occur in most atmospheres. However, for some industrial process applications or for monitoring well characterized atmospheres (where the various failure modes are known) it can be advantageous to combine the on-line TD system with simpler real-time detection technologies; process MS, sensor arrays, infra-red, etc. Trademarks SecureTD-Q and TubeTAG are trademarks of Markes International Ltd. Compatibility with RFID tagged tubes (TubeTAG) for enhanced tube/sample traceability NO post-sampling purge Ethanol represents >99% of total peak area Residual ethanol WITH post-sampling purge Ethanol represents <30% of total peak area Aroma profiling of whisky vapours with e- nose showing differentiation of whiskey types Purging of water and ethanol from whisky headspace vapours allows selective concentration of olfactory compounds. Analysis with GCMS & e-nose

Markes International Ltd. Gwaun Elai Medi Science Campus Llantrisant RCT CF72 8XL United Kingdom T: +44 (0)1443 230935 F: +44 (0)1443 231531 E: enquiries@markes.com W: www.markes.com